224 resultados para Contact Forms
Resumo:
Purpose To examine the influence of short-term miniscleral contact lens wear on corneal shape, thickness and anterior surface aberrations. Methods Scheimpflug imaging was captured before, immediately following and 3 hours after a short period (3 hours) of miniscleral contact lens wear for 10 young (mean 27 ± 5 years), healthy participants. Natural diurnal variations were considered by measuring baseline diurnal changes obtained on a separate control day without contact lens wear. Results Small but significant anterior corneal flattening was observed immediately following lens removal (overall mean 0.02 ± 0.03 mm, p < 0.001) which returned to baseline levels three hours after lens removal. During the three hour recovery period significant corneal thinning (-13.4 ± 10.5 μm) and posterior surface flattening (0.03 ± 0.02 mm) were also observed (both p < 0.01). The magnitude of posterior corneal flattening during recovery correlated with the amount of corneal thinning (r = 0.69, p = 0.03). Central corneal clearance (maximum tear reservoir depth) was not associated with corneal swelling following lens removal (r = -0.24, p > 0.05). An increase in lower-order corneal astigmatism Z(2,2) was also observed following lens wear (mean -0.144 ± 0.075 μm, p = 0.02). Conclusions Flattening of the anterior corneal surface was observed immediately following lens wear, while ‘rebound’ thinning and flattening of the posterior surface was evident following the recovery period. Modern miniscleral contact lenses that vault the cornea may slightly influence corneal shape and power but do not induce clinically significant corneal oedema during short-term wear.
Resumo:
In this research Agency Theory and Stewardship Theory are used to analyse the relative performance of different forms of privitisation of water infrastructure and in doing so enriches understanding of previously underdeveloped aspects of both theories. The prior Agency Theory literature had established assumptions about the behaviour of principals and agents in contracts and these were found not to be correct in the context of contracts between modern government and private organisations. Agency theory was extended to include steward-like behaviour of an agent and Stewardship Theory was developed by the identification of factors within the contractual relationship which promote the sense of responsibility to the principal. The alliance, joint venture and Build Own Operate Transfer (BOOT) forms of privatisation were found to achieve stewardship of the infrastructure.
Resumo:
Whether the first daily disposable soft contact lens to enter the market in 1994 was the Premier lens (Award Technology, Scotland, UK; subsequently purchased by Bausch & Lomb, Rochester New York, USA) or the 1-Day Acuvue lens (Johnson and Johnson Vision Care, Jacksonville, Florida, USA) has long been a matter of bitter dispute1 but whatever the answer, this year marks the 20th anniversary of the launch of this modality of lens wear...
Resumo:
Donald Ezekiel (known to all as ‘Don’) was born in Singapore on September 12, 1936, to a German mother and Iraqi father. His parents were Jewish refugees, who met in Batavia,1 married and alternately lived in Batavia and Singapore. The family established their primary residence in Singapore after Don’s older brother Eric (later to become a haematologist) was born in 1934. The Ezekiel family was forced to flee in 1941 when the Japanese bombed Singapore and were fortunate to obtain passage on a hospital ship to Perth. They returned to Singapore after the war but left again on their own accord in 1951 due to race riots. The Ezekiels sold up everything in Singapore and decided to settle in Perth...
Resumo:
We sought to determine the impact of optometric practice setting on contact lens prescribing by analysing annual survey data of lens fits collected between 2009 and 2013 from independent and national group practices throughout the United Kingdom. Compared to national group practices, independent practices fit contact lenses to older patients and more females. Independent practices also undertake a lower proportion of soft lens fits overall (and thus a higher proportion of rigid lens fits), soft toric lens fits and daily disposable lens fits. There is a higher proportion of soft extended wear and multifocal lens fits in independent practices. We conclude that contact lens fitting behaviour is influenced by optometric practice setting.
Resumo:
The intermediate leaf-nosed bat (Hipposideros larvatus) is a medium-sized bat distributed throughout the Indo-Malay region. In north-east India, bats identified as H. larvatus captured at a single cave emitted echolocation calls with a bimodal distribution of peak frequencies, around either 85 kHz or 98 kHz. Individuals echolocating at 85 kHz had larger ears and longer forearms than those echolocating at 98 kHz, although no differences were detected in either wing morphology or diet, suggesting limited resource partitioning. A comparison of mitochondrial control region haplotypes of the two phonic types with individuals sampled from across the Indo-Malay range supports the hypothesis that, in India, two cryptic species are present. The Indian 98-kHz phonic bats formed a monophyletic clade with bats from all other regional populations sampled, to the exclusion of the Indian 85-kHz bats. In India, the two forms showed 12–13% sequence divergence and we propose that the name Hipposideros khasiana for bats of the 85-kHz phonic type. Bats of the 98-kHz phonic type formed a monophyletic group with bats from Myanmar, and corresponded to Hipposideros grandis, which is suggested to be a species distinct from Hipposideros larvatus. Differences in echolocation call frequency among populations did not reflect phylogenetic relationships, indicating that call frequency is a poor indicator of evolutionary history. Instead, divergence in call frequency probably occurs in allopatry, possibly augmented by character displacement on secondary contact to facilitate intraspecific communication.
Resumo:
Objective: This study investigated the influence of injury cause, contact-sport participation, and prior knowledge of mild traumatic brain injury (mTBI) on injury beliefs and chronic symptom expectations of mTBI. Method: A total of 185 non-contact-sport players (non-CSPs) and 59 contact-sport players (CSPs) with no history of mTBI were randomly allocated to one of two conditions in which they read either a vignette depicting a sport-related mTBI (mTBIsport) or a motor-vehicle-accident-related mTBI (mTBIMVA). The vignettes were otherwise standardized to convey the same injury parameters (e.g., duration of loss of consciousness). After reading a vignette, participants reported their injury beliefs (i.e., perceptions of injury undesirability, chronicity, and consequences) and their expectations of chronic postconcussion syndrome (PCS) and posttraumatic stress disorder (PTSD) symptoms. Results: Non-CSPs held significantly more negative beliefs and expected greater PTSD symptomatology and greater PCS affective symptomatology from an mTBIMVA vignette thann mTBIsport vignette, but this difference was not found for CSPs. Unlike CSPs, non-CSPs who personally knew someone who had sustained an mTBI expected significantly less PCS symptomatology than those who did not. Despite these different results for non-CSPs and CSPs, overall, contact-sport participation did not significantly affect injury beliefs and symptom expectations from an mTBIsport. Conclusions: Expectations of persistent problems after an mTBI are influenced by factors such as injury cause even when injury parameters are held constant. Personal knowledge of mTBI, but not contact sport participation, may account for some variability in mTBI beliefs and expectations. These factors require consideration when assessing mTBI outcome.
Resumo:
A new imaging methodology is described to visualise the post lens tear film (PLTF) during contact lens wear. A rotating-Scheimpflug camera in combination with sodium fluorescein allows evaluation of the PLTF for different contact lens modalities, including mini-scleral, rigid gas permeable (RGP) and soft contact lenses. This imaging technique provides an extension of the instrument’s current functionality. The potential advantages and limitations of the technique are discussed.
Resumo:
This research investigated the potential of folk opera as a tool for HIV and AIDS education in Papua New Guinea. It began with an investigation on the indigenous performativities and theatricalities of Papua New Guineans, conducting an audit of eight selected performance traditions in Papua New Guinea. These traditions were analysed, and five cultural forms and twenty performance elements were drawn out for further exploration. These elements were fused and combined with theatre techniques from western theatre traditions, through a script development process involving Australians, Papua New Guineans and international collaborators. The resulting folk opera, entitled Kumul, demonstrates what Murphy (2010) has termed story force, picture force, and feeling force, in the service of a story designed to educate Papua New Guinean audiences about HIV and the need to adopt safer sexual practices. Kumul is the story of a young man faced with decisions on whether or not to engage in risky sexual behaviours. Kumul's narrative is carefully framed within selected Papua New Guinean beliefs drawn from the audit to deliver HIV and AIDS messages using symbolic and metaphoric communication techniques without offending people. The folk opera Kumul was trialled in two communities in Papua New Guinea: a village community and an urban settlement area. Kumul is recognisable to Papua New Guinean audiences because it reflects their lifestyle and a worldview, which connects them to their beliefs and spirituality, and the larger cosmological order. Feedback from audience members indicated that the performance facilitated HIV and AIDS communication, increased people's awareness of HIV and AIDS, and encouraged behaviour change. Tellingly, in one performance venue, forty people queued for Voluntary Testing and Counseling immediately after the performance. Twenty of these people were tested on that night and the other twenty were tested the following day. Many of the volunteers were young men – a demographic historically difficult to engage in HIV testing. This encouraging result indicates that the Kumul folk opera form of applied theatre could be useful for facilitating communication and education regarding sexual health and safer sexual behaviours in Papua New Guinea. Feedback from participants, audience members and other research stakeholders suggests that the form might also be adapted to address other social and development issues, particularly in the areas of health and social justice.