591 resultados para Ameskar Valley, High Atlas Mountains
Resumo:
This paper reports on statements from Professional Development participants who were asked to comment on NAPLAN. The participants were involved in a project designed by the YuMi Deadly Centre (YDC) for implementation into 25 Queensland School to enhance the teaching and learning of mathematics to Aboriginal and Torres Strait Islander students and low SES students. Using an action research framework and a survey questionnaire, the preliminary data obtained from participating principals is mixed, with statements indicating that NAPLAN is a high priority for some schools while others indicated that it does not “tell” the whole story of student learning.
Resumo:
The design and implementation of a high-power (2 MW peak) vector control drive is described. The inverter switching frequency is low, resulting in high-harmonic-content current waveforms. A block diagram of the physical system is given, and each component is described in some detail. The problem of commanded slip noise sensitivity, inherent in high-power vector control drives, is discussed, and a solution is proposed. Results are given which demonstrate the successful functioning of the system
Resumo:
Improving efficiency and flexibility in pulsed power supply technologies are the most substantial concerns of pulsed power systems specifically for plasma generation. Recently, the improvement of pulsed power supply becomes of greater concern due to extension of pulsed power applications to environmental and industrial areas. A current source based topology is proposed in this paper which gives the possibility of power flow control. The main contribution in this configuration is utilization of low-medium voltage semiconductor switches for high voltage generation. A number of switch-diode-capacitor units are designated at the output of topology to exchange the current source energy into voltage form and generate a pulsed power with sufficient voltage magnitude and stress. Simulations have been carried out in Matlab/SIMULINK platform to verify the capability of this topology in performing desired duties. Being efficient and flexible are the main advantages of this topology.
Resumo:
This paper presents a high voltage pulsed power system based on low voltage switch-capacitor units connected to a current source for several applications such as plasma systems. A modified positive buck-boost converter topology is used to utilize the current source concept and a series of low voltage switch-capacitor units is connected to the current source in order to provide high voltage with high voltage stress (dv/dt) as demanded by loads. This pulsed power converter is flexible in terms of energy control, in that the stored energy in the current source can be adjusted by changing the current magnitude to significantly improve the efficiency of various systems with different requirements. Output voltage magnitude and stress (dv/dt) can be controlled by a proper selection of components and control algorithm to turn on and off switching devices.
Resumo:
The objective of this study was to evaluate the feasibility and potential of a hybrid scaffold system in large- and high-load-bearing osteochondral defects repair. The implants were made of medical-grade PCL (mPCL) for the bone compartment whereas fibrin glue was used for the cartilage part. Both matrices were seeded with allogenic bone marrow-derived mesenchymal cells (BMSC) and implanted in the defect (4 mm diameter×5 mm depth) on medial femoral condyle of adult New Zealand White rabbits. Empty scaffolds were used at the control side. Cell survival was tracked via fluorescent labeling. The regeneration process was evaluated by several techniques at 3 and 6 months post-implantation. Mature trabecular bone regularly formed in the mPCL scaffold at both 3 and 6 months post-operation. Micro-Computed Tomography showed progression of mineralization from the host–tissue interface towards the inner region of the grafts. At 3 months time point, the specimens showed good cartilage repair. In contrast, the majority of 6 months specimens revealed poor remodeling and fissured integration with host cartilage while other samples could maintain good cartilage appearance. In vivo viability of the transplanted cells was demonstrated for the duration of 5 weeks. The results demonstrated that mPCL scaffold is a potential matrix for osteochondral bone regeneration and that fibrin glue does not inherit the physical properties to allow for cartilage regeneration in a large and high-load-bearing defect site. Keywords: Osteochondral tissue engineering; Scaffold; Bone marrow-derived precursor cells; Fibrin glue
Resumo:
Background: Childhood undernutrition and mortality are high in Nepal, and therefore interventions on infant and young child feeding practices deserve high priority. Objective. To estimate infant and young child feeding indicators and the determinants of selected feeding practices. Methods: The sample consisted of 1,906 children aged 0 to 23 months from the Demographic and Health Survey 2006. Selected indicators were examined against a set of variables using univariate and multivariate analyses. Results. Breastfeeding was initiated within the first hour after birth in 35.4% of children, 99.5% were ever breastfed, 98.1% were currently breastfed, and 3.5% were bottle-fed. The rate of exclusive breastfeeding among infants under 6 months of age was 53.1%, and the rate of timely complementary feeding among those 6 to 9 months of age was 74.7%. Mothers who made antenatal clinic visits were at a higher risk for no exclusive breastfeeding than those who made no visits. Mothers who lived in the mountains were more likely to initiate breastfeeding within 1 hour after birth and to introduce complementary feeding at 6 to 9 months of age, but less likely to exclusively breastfeed. Cesarean deliveries were associated with delay in timely initiation of breastfeeding. Higher rates of complementary feeding at 6 to 9 months were also associated with mothers with better education and those above 35 years of age. Risk factors for bottle-feeding included living in urban areas and births attended by trained health personnel. Conclusions: Most breastfeeding indicators in Nepal are below the expected levels to achieve a substantial reduction in child mortality. Breastfeeding promotion strategies should specifically target mothers who have more contact with the health care delivery system, while programs targeting the entire community should be continued.
Resumo:
BLAST Atlas is a visual analysis system for comparative genomics that supports genome-wide gene characterisation, functional assignment and function-based browsing of one or more chromosomes. Inspired by applications such as the WorldWide Telescope, Bing Maps 3D and Google Earth, BLAST Atlas uses novel three-dimensional gene and function views that provide a highly interactive and intuitive way for scientists to navigate, query and compare gene annotations. The system can be used for gene identification and functional assignment or as a function-based multiple genome comparison tool which complements existing position based comparison and alignment viewers.
Resumo:
There are several noninvasive techniques for assessing the kinetics of tear film, but no comparative studies have been conducted to evaluate their efficacies. Our aim is to test and compare techniques based on high-speed videokeratoscopy (HSV), dynamic wavefront sensing (DWS), and lateral shearing interferometry (LSI). Algorithms are developed to estimate the tear film build-up time TBLD, and the average tear film surface quality in the stable phase of the interblink interval TFSQAv. Moderate but significant correlations are found between TBLD measured with LSI and DWS based on vertical coma (Pearson's r2=0.34, p<0.01) and higher order rms (r2=0.31, p<0.01), as well as between TFSQAv measured with LSI and HSV (r2=0.35, p<0.01), and between LSI and DWS based on the rms fit error (r2=0.40, p<0.01). No significant correlation is found between HSV and DWS. All three techniques estimate tear film build-up time to be below 2.5 sec, and they achieve a remarkably close median value of 0.7 sec. HSV appears to be the most precise method for measuring tear film surface quality. LSI appears to be the most sensitive method for analyzing tear film build-up.