468 resultados para energy gain
Resumo:
The most suitable temperature range for domestic purposes is about 200C to 260C .Besides, both cold and hot water appear to be essential frequently for industrial purposes. In summer bringing down the water temperature at a comfortable range causes significant energy consumption. This project aims at saving energy to control water temperature by making water tank insulated .Therefore applying better insulation system which would reduce the disparity between the desired temperature and the actual temperature and hence saving energy significantly. Following the investigation, this project used cotton jacket to insulate the tank and the tank was placed under a paddy straw shade with a view to attaining the maximum energy saving. Finally, it has been found that reduction in energy consumption is to be about 50-60% which is quite satisfactory. Since comfortable temperature range varies from person to person this project thus combines insulating effect with automatic water heater.
Resumo:
The conversion of tamarind seeds into pyrolytic oil by fixed bed fire-tube heating reactor has been taken into consideration in this study. The major components of the system were fixed bed fire-tube heating reactor, liquid condenser and collectors. The raw and crushed tamarind seed in particle form was pyrolized in an electrically heated 10 cm diameter and 27 cm high fixed bed reactor. The products are oil, char and gases. The parameters varied were reactor bed temperature, running time, gas flow rate and feed particle size. The parameters were found to influence the product yields significantly. The maximum liquid yield was 45 wt% at 4000C for a feed size of 1.07cm3 at a gas flow rate of 6 liter/min with a running time of 30 minute. The pyrolysis oil was obtained at these optimum process conditions were analyzed for physical and chemical properties to be used as an alternative fuel.
Resumo:
Road safety barriers are used to minimise the severity of road accidents and protect lives and property. There are several types of barrier in use today. This paper reports the initial phase of research carried out to study the impact response of portable water-filled barrier (PWFB) which has the potential to absorb impact energy and hence provide crash mitigation under low to moderate speeds. Current research on the impact and energy absorption capacity of water-filled road safety barriers is limited due to the complexity of fluid-structure interaction under dynamic impact. In this paper, a novel fluid-structure interaction method is developed based on the combination of Smooth Particle Hydrodynamics (SPH) and Finite Element Method (FEM). The sloshing phenomenon of water inside a PWFB is investigated to explore the energy absorption capacity of water under dynamic impact. It was found that water plays an important role in energy absorption. The coupling analysis developed in this paper will provide a platform to further the research in optimising the behaviour of the PWFB. The effect of the amount of water on its energy absorption capacity is investigated and the results have practical applications in the design of PWFBs.
Resumo:
Improving energy efficiency has become increasingly important in data centers in recent years to reduce the rapidly growing tremendous amounts of electricity consumption. The power dissipation of the physical servers is the root cause of power usage of other systems, such as cooling systems. Many efforts have been made to make data centers more energy efficient. One of them is to minimize the total power consumption of these servers in a data center through virtual machine consolidation, which is implemented by virtual machine placement. The placement problem is often modeled as a bin packing problem. Due to the NP-hard nature of the problem, heuristic solutions such as First Fit and Best Fit algorithms have been often used and have generally good results. However, their performance leaves room for further improvement. In this paper we propose a Simulated Annealing based algorithm, which aims at further improvement from any feasible placement. This is the first published attempt of using SA to solve the VM placement problem to optimize the power consumption. Experimental results show that this SA algorithm can generate better results, saving up to 25 percentage more energy than First Fit Decreasing in an acceptable time frame.
Resumo:
Server consolidation using virtualization technology has become an important technology to improve the energy efficiency of data centers. Virtual machine placement is the key in the server consolidation. In the past few years, many approaches to the virtual machine placement have been proposed. However, existing virtual machine placement approaches to the virtual machine placement problem consider the energy consumption by physical machines in a data center only, but do not consider the energy consumption in communication network in the data center. However, the energy consumption in the communication network in a data center is not trivial, and therefore should be considered in the virtual machine placement in order to make the data center more energy-efficient. In this paper, we propose a genetic algorithm for a new virtual machine placement problem that considers the energy consumption in both the servers and the communication network in the data center. Experimental results show that the genetic algorithm performs well when tackling test problems of different kinds, and scales up well when the problem size increases.
Resumo:
Exploiting wind-energy is one possible way to extend flight duration for Unmanned Arial Vehicles. Wind-energy can also be used to minimise energy consumption for a planned path. In this paper, we consider uncertain time-varying wind fields and plan a path through them. A Gaussian distribution is used to determine uncertainty in the Time-varying wind fields. We use Markov Decision Process to plan a path based upon the uncertainty of Gaussian distribution. Simulation results that compare the direct line of flight between start and target point and our planned path for energy consumption and time of travel are presented. The result is a robust path using the most visited cell while sampling the Gaussian distribution of the wind field in each cell.
Resumo:
Australia is rich in renewable energy resources such as wind, solar and geothermal. Geographical diversity of these renewable resources combined with developing climate change policies poses a great challenge for the long term interconnection planning. Intermittency of wind and solar potentially driving the development of new transmission lines bring additional complexity to power system operations and planning. This paper provides an overview of generation and transmission planning studies in Australia to meet 20% renewable energy target by 2020. Appraisal of the effectiveness of dispersed energy storage, non schedulable peaking plants, wide area controls and demand management techniques to aid the penetration of renewables is presented in this paper
Resumo:
The available wind power is stochastic and requires appropriate tools in the OPF model for economic and reliable power system operation. This paper exhibit the OPF formulation with factors involved in the intermittency of wind power. Weibull distribution is adopted to find the stochastic wind speed and power distribution. The reserve requirement is evaluated based on the wind distribution and risk of under/over estimation of the wind power. In addition, the Wind Energy Conversion System (WECS) is represented by Doubly Fed Induction Generator (DFIG) based wind farms. The reactive power capability for DFIG based wind farm is also analyzed. The study is performed on IEEE-30 bus system with wind farm located at different buses and with different wind profiles. Also the reactive power capacity to be installed in the wind farm to maintain a satisfactory voltage profile under the various wind flow scenario is demonstrated.
Resumo:
A new decision-making tool that will assist designers in the selection of appropriate daylighting solutions for buildings in tropical locations has been previously proposed by the authors. Through an evaluation matrix that prioritizes the parameters that best respond to the needs of tropical climates (e.g. reducing solar gain and protection from glare) the tool determines the most appropriate devices for specific climate and building inputs. The tool is effective in demonstrating the broad benefits and limitations of the different daylight strategies for buildings in the tropics. However for thorough analysis and calibration of the tool, validation is necessary. This paper presents a first step in the validation process. RADIANCE simulations were conducted to compare simulation performance with the performance predicted by the tool. To this end, an office building case study in subtropical Brisbane, Australia, and five different daylighting devices including openings, light guiding systems and light transport systems were simulated. Illuminance, light uniformity, daylight penetration and glare analysis were assessed for each device. The results indicate the tool can appropriately rank and recommend daylighting strategies based on specific building inputs for tropical and subtropical regions, making it a useful resource for designers.
Resumo:
Overconsumption is commonly implicated in the aetiology of obesity; however there is a lack of consensus on a definition and the most appropriate methodology for assessing it. The aim of this communication is to highlight the need for theoretical consensus on the assessment of overconsumption, which may lead to improved methodological standards in obesity research. In laboratory studies, overconsumption is most frequently inferred from the comparison of food intake within or between individuals against a single control. Measurement often relies on a single eating episode with limited consideration of preceding or subsequent intake. An alternative approach is to consider food intake in the context of energy requirements, within an energy balance framework. One such marker of chronic overconsumption is body weight. There is a need for agreement on the definition and measurement of overconsumption, so that its role in weight gain and obesity can be more precisely delineated.
Resumo:
Background & Aims: Inadequate feeding assistance and mealtime interruptions during hospitalisation may contribute to malnutrition and poor nutritional intake in older people. This study aimed to implement and compare three interventions designed to specifically address mealtime barriers and improve energy intakes of medical inpatients aged ≥65 years. Methods: Pre-post study compared three mealtime assistance interventions: PM: Protected Mealtimes with multidisciplinary education; AIN: additional assistant-in-nursing (AIN) with dedicated meal role; PM+AIN: combined intervention. Dietary intake of 254 patients (pre: n=115, post: n=141; mean age 80±8) was visually estimated on a single day in the first week of hospitalisation and compared with estimated energy requirements. Assistance activities were observed and recorded. Results: Mealtime assistance levels significantly increased in all interventions (p<0.01). Post-intervention participants were more likely to achieve adequate energy intake (OR=3.4, p=0.01), with no difference noted between interventions (p=0.29). Patients with cognitive impairment or feeding dependency appeared to gain substantial benefit from mealtime assistance interventions. Conclusions: Protected Mealtimes and additional AIN assistance (implemented alone or in combination) may produce modest improvements in nutritional intake. Targeted feeding assistance for certain patient groups holds promise; however, alternative strategies are required to address the complex problem of malnutrition in this population.
Resumo:
Background: While weight gain during pregnancy is regarded as important, there has not been a prospective study of measured weight gain in pregnancy in Australia. This study aimed to prospectively evaluate pregnancy-related weight gain against the Institute of Medicine (IOM) recommendations in women receiving antenatal care in a setting where ongoing weight monitoring is not part of routine clinical practice, to describe women's knowledge of weight gain recommendations and to describe the health professional advice received relating to gestational weight gain (GWG). Methods: Pregnant women were recruited ≤20 weeks of gestation (n = 664) from a tertiary obstetric hospital between August 2010 to July 2011 for this prospective observational study. Outcome measures were weight gain from pre-pregnancy to 36 weeks of gestation, weight gain knowledge and health professional advice received. Results: Thirty-six percent of women gained weight according to guidelines. Twenty-six percent gained inadequate weight, and 38% gained excess weight. Fifty-six percent of overweight women gained weight in excess of the IOM guidelines compared with 30% of those who started with a healthy weight (P < 0.001). At 16 weeks, 47% of participants were unsure of the weight gain recommendations for them. Sixty-two percent of women reported that the health professionals caring for them during this pregnancy ‘never’ or ‘rarely’ offered advice about how much weight to gain. Conclusions: The prevalence of inappropriate gestational weight gain in this study was high. The majority of women do not know their recommended weight gain. The advice women received from health professionals relating to healthy weight gain in pregnancy could be improved.
Resumo:
Aim: Maternal obesity is associated with increased risk of adverse outcomes for mothers and offspring. Strategies to better manage maternal obesity are urgently needed; however, there is little evidence to assist the development of nutrition interventions during antenatal care. The present study aimed to assess maternal weight gain and dietary intakes of overweight and obese women participating in an exercise trial. Results will assist the development of interventions for the management of maternal overweight and obesity. Methods: Fifty overweight and obese pregnant women receiving antenatal care were recruited and provided dietary and weight data at baseline (12 weeks), 28 weeks, 36 weeks gestation and 6 weeks post-partum. Data collected were compared with current nutritional and weight gain recommendations. Associations used Pearson's correlation coefficient, and ANOVA assessed dietary changes over time, P < 0.05. Results: Mean prepregnancy body mass index was 34.4 ± 6.6 kg/m2. Gestational weight gain was 10.6 ± 6 kg with a wide range (−4.1 to 23.0 kg). 52% of women gained excessive weight (>11.5 kg for overweight and >9 kg for obese women). Gestational weight gain correlated with post-partum weight retention (P < 0.001). Dietary intakes did not change significantly during pregnancy. No women achieved dietary fat or dietary iron recommendations, only 11% achieved adequate dietary folate, and 38% achieved adequate dietary calcium. Very few women achieved recommended food group servings for pregnancy, with 83% consuming excess servings of non-core foods. Conclusion: Results provide evidence that early intervention and personalised support for obese pregnant women may help achieve individualised goals for maternal weight gain and dietary adequacy, but this needs to be tested in a clinical setting.
Resumo:
This paper presents an analytical model to study the effect of stiffening ribs on vibration transmission between two rectangular plates coupled at right angle. Interesting wave attenuation patterns were observed by placing the stiffening rib either on the source or on the receiving plate. The result can be used to improve the understanding of vibration and for vibration control of more complex structures such as transformer tanks and machine covers.