235 resultados para Wavefront testing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effluent from sewage treatment plants has been associated with a range of pollutant effects. Depending on the influent composition and treatment processes the effluent may contain a myriad of different chemicals which makes monitoring very complex. In this study we aimed to monitor relatively polar organic pollutant mixtures using a combination of passive sampling techniques and a set of biochemistry based assays covering acute bacterial toxicity (Microtox™), phytotoxicity (Max-I-PAM assay) and genotoxicity (umuC assay). The study showed that all of the assays were able to detect effects in the samples and allowed a comparison of the two plants as well as a comparison between the two sampling periods. Distinct improvements in water quality were observed in one of the plants as result of an upgrade to a UV disinfection system, which improved from 24× sample enrichment required to induce a 50% response in the Microtox™ assay to 84×, from 30× sample enrichment to induce a 50% reduction in photosynthetic yield to 125×, and the genotoxicity observed in the first sampling period was eliminated. Thus we propose that biochemical assay techniques in combination with time integrated passive sampling can substantially contribute to the monitoring of polar organic toxicants in STP effluents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose Two diodes which do not require correction factors for small field relative output measurements are designed and validated using experimental methodology. This was achieved by adding an air layer above the active volume of the diode detectors, which canceled out the increase in response of the diodes in small fields relative to standard field sizes. Methods Due to the increased density of silicon and other components within a diode, additional electrons are created. In very small fields, a very small air gap acts as an effective filter of electrons with a high angle of incidence. The aim was to design a diode that balanced these perturbations to give a response similar to a water-only geometry. Three thicknesses of air were placed at the proximal end of a PTW 60017 electron diode (PTWe) using an adjustable “air cap”. A set of output ratios (ORfclin Det ) for square field sizes of side length down to 5 mm was measured using each air thickness and compared to ORfclin Det measured using an IBA stereotactic field diode (SFD). k fclin, f msr Qclin,Qmsr was transferred from the SFD to the PTWe diode and plotted as a function of air gap thickness for each field size. This enabled the optimal air gap thickness to be obtained by observing which thickness of air was required such that k fclin, f msr Qclin,Qmsr was equal to 1.00 at all field sizes. A similar procedure was used to find the optimal air thickness required to make a modified Sun Nuclear EDGE detector (EDGEe) which s “correction-free” in small field relative dosimetry. In addition, the feasibility of experimentally transferring k fclin, f msr Qclin,Qmsr values from the SFD to unknown diodes was tested by comparing the experimentally transferred k fclin, f msr Qclin,Qmsr values for unmodified PTWe and EDGEe diodes to Monte Carlo simulated values. Results 1.0 mm of air was required to make the PTWe diode correction-free. This modified diode (PTWeair) produced output factors equivalent to those in water at all field sizes (5–50 mm). The optimal air thickness required for the EDGEe diode was found to be 0.6 mm. The modified diode (EDGEeair) produced output factors equivalent to those in water, except at field sizes of 8 and 10 mm where it measured approximately 2% greater than the relative dose to water. The experimentally calculated k fclin, f msr Qclin,Qmsr for both the PTWe and the EDGEe diodes (without air) matched Monte Carlo simulated results, thus proving that it is feasible to transfer k fclin, f msr Qclin,Qmsr from one commercially available detector to another using experimental methods and the recommended experimental setup. Conclusions It is possible to create a diode which does not require corrections for small field output factor measurements. This has been performed and verified experimentally. The ability of a detector to be “correction-free” depends strongly on its design and composition. A nonwater-equivalent detector can only be “correction-free” if competing perturbations of the beam cancel out at all field sizes. This should not be confused with true water equivalency of a detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel burn wound hydrogel dressing has been previously developed which is composed of 2-acrylamido-2-methylpropane sulfonic acid sodium salt with silver nanoparticles (silver AMPS). This study compared the cytotoxicity of this dressing to the commercially available silver products; Acticoat™, PolyMem Silver® and Flamazine™ cream. Human keratinocytes (HaCaT and primary HEK) and normal human fibroblasts (NHF) were exposed to dressings incubated on Nunc™ polycarbonate inserts for 24, 48 and 72h. Four different cytotoxicity assays were performed including; Trypan Blue cell count, MTT, Celltiter-Blue™ and Toluidine Blue surface area assays. The results were expressed as relative cell viability compared to an untreated control. The cytotoxic effects of Acticoat™ and Flamazine™ cream were dependent on exposure time and cell type. After 24h exposure, Acticoat™ and Flamazine™ cream were toxic to all tested cell lines. Surprisingly, HaCaTs treated with Acticoat™ and Flamazine™ had an improved ability to survive at 48 and 72h while HEKs and NHFs had no improvement in survival with any treatment. The novel silver hydrogel and PolyMem Silver® showed low cytotoxicity to all tested cell lines at every time interval and these results support the possibility of using the novel silver hydrogel as a burn wound dressing. Researchers who rely on HaCaT cells as an accurate keratinocyte model should be aware that they can respond differently to primary skin cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Exercise and adequate self-management capacity may be important strategies in the management of venous leg ulcers. However, it remains unclear if exercise improves the healing rates of venous leg ulcers and if a self-management exercise program based on self-efficacy theory is well adhered to. Method/Design: This is a randomised controlled in adults with venous leg ulcers to determine the effectiveness of a self-efficacy based exercise intervention. Participants with venous leg ulcers are recruited from 3 clinical sites in Australia. After collection of baseline data, participants are randomised to either an intervention group or control group. The control group receive usual care, as recommended by evidence based guidelines. The intervention group receive an individualised program of calf muscle exercises and walking. The twelve week exercise program integrates multiple elements, including up to six telephone delivered behavioural coaching and goal setting sessions, supported by written materials, a pedometer and two follow-up booster calls if required. Participants are encouraged to seek social support among their friends, self-monitor their weekly steps and lower limb exercises. The control group are supported by a generic information sheet that the intervention group also receive encouraging lower limb exercises, a pedometer for self-management and phone calls at the same time points as the intervention group. The primary outcome is the healing rates of venous leg ulcers which are assessed at fortnightly clinic appointments. Secondary outcomes, assessed at baseline and 12 weeks: functional ability (range of ankle motion and Tinetti gait and balance score), quality of life and self-management scores. Discussion: This study seeks to address a significant gap in current wound management practice by providing evidence for the effectiveness of a home-based exercise program for adults with venous leg ulcers. Theory-driven, evidence-based strategies that can improve an individual’s exercise self-efficacy and self-management capacity could have a significant impact in improving the management of people with venous leg ulcers. Information gained from this study will provide much needed information on management of this chronic disease to promote health and independence in this population. Trial registration: Australian New Zealand Clinical Trials Registry ACTRN12612000475842 Trial status: Current follow up

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fire resistance rating of light gauge steel frame (LSF) wall systems is obtained from fire tests based on the standard fire time-temperature curve. However, fire severity has increased in modern buildings due to higher fuel loads as a result of modern furniture and light weight constructions that make use of thermoplastics materials, synthetic foams and fabrics. Some of these materials are high in calorific values and increase both the spread of fire growth and heat release rate, thus increasing the fire severity beyond that of the standard fire curve. Further, the standard fire curve does not include a decay phase that is present in natural fires. Despite the increasing usage of LSF walls, their behaviour in real building fires is not fully understood. This paper presents the details of a research study aimed at developing realistic design fire curves for use in the fire tests of LSF walls. It includes a review of the characteristics of building fires, previously developed fire time-temperature curves, computer models and available parametric equations. The paper highlights that real building fire time-temperature curves depend on the fuel load representing the combustible building contents, ventilation openings and thermal properties of wall lining materials, and provides suitable values of many required parameters including fuel loads in residential buildings. Finally, realistic design fire time-temperature curves simulating the fire conditions in modern residential buildings are proposed for the testing of LSF walls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis reports on a multiple case study of the actions of three Queensland secondary schools in the context of Year 9 NAPLAN numeracy testing, focusing on their administrative practices, curriculum, pedagogy and assessment. It was established that schools have found it both challenging and costly to operate in an environment of educational reform generally, and NAPLAN testing in particular. The lack of a common understanding of numeracy and the substantial demands of implementing the Australian Curriculum have impacted on schools' ability to prepare students appropriately for NAPLAN numeracy tests. It was concluded that there is scope for schools to improve their approaches to NAPLAN numeracy testing in a way that maximises learning as well as test outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Research into youth caregiving in families where a parent experiences a significant medical condition has been hampered by a lack of contextually sensitive measures of the nature and breadth of young caregiving experiences. This study examined the factor structure and measurement invariance of such a measure called the Young Carer of Parents Inventory (YCOPI; Pakenham et al., 2006) using confirmatory factor analysis across 3 groups of youth. The YCOPI has 2 parts: YCOPI-A with 5 factors assessing caregiving experiences that are applicable to all caregiving contexts; YCOPI-B with 4 factors that tap dimensions related to youth caregiving in the context of parent illness. Design Two samples (ages 9–20 years) were recruited: a community sample of 2,429 youth from which 2 groups were derived (“healthy” family [HF], n = 1760; parental illness [PI], n = 446), and a sample of 130 youth of a parent with multiple sclerosis). Results With some modification, the YCOPI-A demonstrated a replicable factor structure across 3 groups, and exhibited only partial measurement invariance across the HF and PI groups. The impact of assuming full measurement invariance on latent mean differences appeared small, supporting use of the measure in research and applied settings when estimated using latent factors and controlling for measurement invariance. PI youth reported significantly higher scores than did HF youth on all YCOPI-A subscales. The YCOPI-B requires some modifications, and further development work is recommended. Conclusion The factor structure that emerged and the addition of new items constitutes the YCOPI-Revised. Findings support the use of the YCOPI-Revised in research and applied settings.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study assessed the prevalence of and factors associated with HIV testing among male street laborers. In a cross-sectional survey, social mapping was done to recruit and interview 450 men aged 18–59 years in Hanoi. Although many of these men engaged in multiple risk behaviors for HIV, only 19.8 percent had been tested for HIV. A modified theoretical model provided better fit than the conventional Information–Motivation–Behavioral Skills model, as it explained much more variance in HIV testing. This model included three Information–Motivation–Behavioral components and four additional factors, namely, the origin of residence, sexual orientation, the number of sexual partners, and the status of condom use.