312 resultados para Environmental monitoring - Australia


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Positive and negative small ions, aerosol ion and number concentration and dc electric fields were monitored at an overhead high-voltage power line site. We show that the emission of corona ions was not spatially uniform along the lines and occurred from discrete components such as a particular set of spacers. Maximum ion concentrations and atmospheric dc electric fields were observed at a point 20 m downwind of the lines. It was estimated that less than 7% of the total number of aerosol particles was charged. The electrical parameters decreased steadily with further downwind distance but remained significantly higher than background.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A 4-cylinder Ford 2701C test engine was used in this study to explore the impact of ethanol fumigation on gaseous and particle emission concentrations. The fumigation technique delivered vaporised ethanol into the intake manifold of the engine, using an injector, a pump and pressure regulator, a heat exchanger for vaporising ethanol and a separate fuel tank and lines. Gaseous (Nitric oxide (NO), Carbon monoxide (CO) and hydrocarbons (HC)) and particulate emissions (particle mass (PM2.5) and particle number) testing was conducted at intermediate speed (1700 rpm) using 4 load settings with ethanol substitution percentages ranging from 10-40 % (by energy). With ethanol fumigation, NO and PM2.5 emissions were reduced, whereas CO and HC emissions increased considerably and particle number emissions increased at most test settings. It was found that ethanol fumigation reduced the excess air factor for the engine and this led to increased emissions of CO and HC, but decreased emissions of NO. PM2.5 emissions were reduced with ethanol fumigation, as ethanol has a very low “sooting” tendency. This is due to the higher hydrogen-to-carbon ratio of this fuel, and also because ethanol does not contain aromatics, both of which are known soot precursors. The use of a diesel oxidation catalyst (as an after-treatment device) is recommended to achieve a reduction in the four pollutants that are currently regulated for compression ignition engines. The increase in particle number emissions with ethanol fumigation was due to the formation of volatile (organic) particles; consequently, using a diesel oxidation catalyst will also assist in reducing particle number emissions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Visual sea-floor mapping is a rapidly growing application for Autonomous Underwater Vehicles (AUVs). AUVs are well-suited to the task as they remove humans from a potentially dangerous environment, can reach depths human divers cannot, and are capable of long-term operation in adverse conditions. The output of sea-floor maps generated by AUVs has a number of applications in scientific monitoring: from classifying coral in high biological value sites to surveying sea sponges to evaluate marine environment health.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Particulate matter (PM) emissions involve a complex mixture of solid and liquid particles suspended in a gas, where it is noted that PM emissions from diesel engines are a major contributor to the ambient air pollution problem. Whilst epidemiological studies have shown a link between increased ambient PM emissions and respiratory morbidity and mortality, studies of this design are not able to identify the PM constituents responsible for driving adverse respiratory health effects. This review explores in detail the physico-chemical properties of diesel particulate matter (DPM), and identifies the constituents of this pollution source that are responsible for the development of respiratory disease. In particular, this review shows that the DPM surface area and adsorbed organic compounds play a significant role in manifesting chemical and cellular processes that if sustained can lead to the development of adverse respiratory health effects. The mechanisms of injury involved included: inflammation, innate and acquired immunity, and oxidative stress. Understanding the mechanisms of lung injury from DPM will enhance efforts to protect at-risk individuals from the harmful respiratory effects of air pollutants.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Atmospheric nanoparticles are one of those pollutants currently unregulated through ambient air quality standards. The aim of this chapter is to assess the environmental and health impacts of atmospheric nanoparticles in European environments. The chapter begins with the conventional information on the origin of atmospheric nanoparticles, followed by their physical and chemical characteristics. A brief overview of recently published review articles on this topic is then presented to guide those readers interested in exploring any specific aspect of nanoparticles in greater detail. A further section reports a summary of recently published studies on atmospheric nanoparticles in European cities. This covers a total of about 45 sampling locations in 30 different cities within 15 European countries for quantifying levels of roadside and urban background particle number concentrations (PNCs). Average PNCs at roadside and urban background sites were found to be 3.82±3.25 ×104 cm–3 and 1.63±0.82 ×104 cm–3, respectively, giving a roadside to background PNC ratio of ~2.4. Engineered nanoparticles are one of the key emerging categories of airborne nanoparticles, especially for the indoor environments. Their ambient concentrations may increase in future due to widespread use of nanotechnology integrated products. Evaluation of their sources and probable impacts on air quality and human health are briefly discussed in the following section. Respiratory deposition doses received by the public exposed to roadside PNCs in numerous European locations are then estimated. These were found to be in the 1.17–7.56 1010 h–1 range over the studied roadside European locations. The following section discusses the potential framework for airborne nanoparticle regulations in Europe and, in addition, the existing control measures to limit nanoparticle emissions at source. The chapter finally concludes with a synthesis of the topic areas covered and highlights important areas for further work.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Recent research has described the restructuring of particles upon exposure to organic vapours; however, as yet hypotheses able to explain this phenomenon are limited. In this study, a range of experiments were performed to explore different hypotheses related to carbonaceous particle restructuring upon exposure to organic and water vapours, such as: the effect of surface tension, the role of organics in flocculating primary particles, as well as the ability of vapours to “wet” the particle surface. The change in mobility diameter (dm) was investigated for a range carbonaceous particle types (diesel exhaust, petrol exhaust, cigarette smoke, candle smoke, particles generated in a heptane/toluene flame, and wood smoke particles) exposed to different organic (heptane, ethanol, and dimethyl sulfoxide/water (1:1 vol%) mixture) and water vapours. Particles were first size-selected and then bubbled through an impinger (bubbler) containing either an organic solvent or water, where particles trapped inside rising bubbles were exposed to saturated vapours of the solvent in the impinger. The size distribution of particles was simultaneously measured upstream and downstream from the impinger. A size-dependent reduction in dm was observed when bubbling diesel exhaust, particles generated in a heptane/toluene flame, and candle smoke particles through heptane, ethanol and a dimethyl sulfoxide/water (1:1 vol %) mixture. In addition, the size distributions of particles bubbled through an impinger were broader. Moreover, an increase of the geometric standard deviation (σ) of the size distributions of particles bubbled through an impinger was also found to be size-dependent. Size-dependent reduction in dm and an increase of σ indicate that particles undergo restructuring to a more compact form, which was confirmed by TEM analysis. However, bubbling of these particles through water did not result in a size-dependent reduction in dm, nor in an increase of σ. Cigarette smoke, petrol exhaust, and wood smoke particles did not result in any substantial change in dm, or σ, when bubbled through organic solvents or water. Therefore, size-dependent reduction in the dm upon bubbling through organic solvents was observed only for particles that had a fractal-like structure, whilst particles that were liquid or were assumed to be spherical did not exhibit any reduction in dm. Compaction of fractal-like particles was attributed to the ability of condensing vapours to efficiently wet the particles. Our results also show that the presence of an organic layer on the surface of fractal-like particles, or the surface tension of the condensed liquid do not influence the extent of compaction.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Time-activity patterns and the airborne pollutant concentrations encountered by children each day are an important determinant of individual exposure to airborne particles. This is demonstrated in this work by using hand-held devices to measure the real-time individual exposure of more than 100 children aged 8-11 years to particle number concentrations and average particle diameter, as well as alveolar and tracheobronchial deposited surface area concentration. A GPS-logger and activity diaries were also used to give explanation to the measurement results. Children were divided in three sample groups: two groups comprised of urban schools (school time from 8:30 am to 1:30 pm) with lunch and dinner at home, and the third group of a rural school with only dinner at home. The mean individual exposure to particle number concentration was found to differ between the three groups, ranging from 6.2×104 part. cm-3 for children attending one urban school to 1.6×104 part. cm-3 for the rural school. The corresponding daily alveolar deposited surface area dose varied from about 1.7×103 mm2 for urban schools to 6.0×102 mm2 for the rural school. For all of the children monitored, the lowest particle number concentrations are found during sleeping time and the highest were found during eating time. With regard to alveolar deposited surface area dose, a child's home was the major contributor (about 70%), with school contributing about 17% for urban schools and 27% for the rural school. An important contribution arises from the cooking/eating time spent at home, which accounted for approximately 20% of overall exposure, corresponding to more than 200 mm2. These activities represent the highest dose received per time unit, with very high values also encountered by children with a fireplace at home, as well as those that spend considerable time stuck in traffic jams.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Quantifying spatial and/or temporal trends in environmental modelling data requires that measurements be taken at multiple sites. The number of sites and duration of measurement at each site must be balanced against costs of equipment and availability of trained staff. The split panel design comprises short measurement campaigns at multiple locations and continuous monitoring at reference sites [2]. Here we present a modelling approach for a spatio-temporal model of ultrafine particle number concentration (PNC) recorded according to a split panel design. The model describes the temporal trends and background levels at each site. The data were measured as part of the “Ultrafine Particles from Transport Emissions and Child Health” (UPTECH) project which aims to link air quality measurements, child health outcomes and a questionnaire on the child’s history and demographics. The UPTECH project involves measuring aerosol and particle counts and local meteorology at each of 25 primary schools for two weeks and at three long term monitoring stations, and health outcomes for a cohort of students at each school [3].

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Recent findings concerning exhaled aerosol size distributions and the regions in the respiratory tract in which they are generated could have significant implications for human to human spread of lower respiratory tract-specific infections. Even in healthy people, measurable quantities of aerosol are routinely generated from the Lower Respiratory Tract (LRT) during breathing(1-3). We have found that there at least three modes in the exhaled aerosol size distribution of healthy adults(4) (see Figure 1). These modes each have a characteristic size and arise from different parts of the respiratory tract. The respiratory bronchioles produce aerosol during breathing, the larynx during speech and the oral cavity also during speech. The model of the resulting droplet size distribution is therefore called the Bronchial Laryngeal Oral (B.L.O.) tri-modal model of expired aerosol.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Potential adverse effects on children health may result from school exposure to airborne particles. To address this issue, measurements in terms of particle number concentration, particle size distribution and black carbon (BC) concentrations were performed in three school buildings in Cassino (Italy) and its suburbs, outside and inside of the classrooms during normal occupancy and use. Additional time resolved information was gathered on ventilation condition, classroom activity, and traffic count data around the schools were obtained using a video camera. Across the three investigated school buildings, the outdoor and indoor particle number concentration monitored down to 4 nm and up to 3 m ranged from 2.8×104 part cm-3 to 4.7×104 part cm-3 and from 2.0×104 part cm-3 to 3.5×104 part cm-3, respectively. The total particle concentrations were usually higher outdoors than indoors, because no indoor sources were detected. I/O measured was less than 1 (varying in a relatively narrow range from 0.63 to 0.74), however one school exhibited indoor concentrations higher than outdoor during the morning rush hours. Particle size distribution at the outdoor site showed high particle concentrations in different size ranges, varying during the day; in relation to the starting and finishing of school time two modes were found. BC concentrations were 5 times higher at the urban school compared with the suburban and suburban-to-urban differences were larger than the relative differences of ultrafine particle concentrations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Airborne particulate matter pollution is of concern for a number of reasons and has been widely recognised as an important risk factor to human health. A number of toxicological and epidemiological studies reported negative health effects on both respiratory and cardiovascular system. Despite the availability of a huge body of research, the underlying toxicological mechanisms by which particles induce adverse health effects are not yet entirely understood. The production of reactive oxygen species (ROS) has been shown to induce oxidative stress, which is proposed as a mechanism for many of the adverse health outcomes associated with exposure to particulate matter (PM). Therefore, it is crucial to introduce a technique that will allow rapid and routine screenings of the oxidative potential of PM.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Vehicle emissions have been linked to detrimental health effects with children thought to be more susceptible (See e.g., Ryan et al 2005). In an urban environment a major source of organic aerosols (OA) are vehicle emissions. The ambient concentration of OA is dynamic in nature and the use of an aerosol mass spectrometer can achieve the necessary temporal resolution to capture the daily variation of OA (Jimenez et al 2009). Currently there is a limited understanding of effects of long term exposure to traffic emissions on children’s health. In the present study, we used an aerosol mass spectrometer to monitor OA and determine children’s potential exposure at school to traffic emissions.In this paper, we present the preliminary results of this investigation. The study is a part of a larger project aimed at gaining a holistic picture of the exposure of children to traffic related pollutants, known as UPTECH (www.ilaqh.qut.edu.au/Misc/ UPTECH%20Home.htm).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Eepidemiological studies have linked exposure to ultrafine particles (UFPs, <100 nm) to a variety of adverse health effects. To understand the mechanisms behind these effects, it is essential to measure aerosol deposition in the human respiratory tract. Electrical charge is a very important property as it may increase the particle deposition in human respiratory tract (Melanderi et al., 1983). However, the effect of charge on UFP deposition has seldom been investigated. The aim of this study is to investigate the effect of charge on UFP deposition in human lung, by conducting a pilot study using a tube-based experimental system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Traffic emissions are considered as a major source of pollutants, particularly ultrafine particles, in the urban environment. There is an increased concern about airborne particles not only because of their environmental effects but also due to their potential adverse health effects on humans. There have been a number of studies related to the number concentration and size distribution of these particles but studies on the chemical composition of aerosols, especially in the school environment, are very limited. Mejia et. al (2011) reviewed studies on the exposure to and impact of air pollutants on school children and found that there were only a handful of studies on this topic. Therefore, the main focus of this research is on an analysis of the chemical composition of airborne particles, as well as source apportionment and the quantification of ambient concentrations of organic pollutants in the vicinity of schools, as a part of “Ultrafine Particles from Traffic Emissions on Children’s Health” (UPTECH) project. The aim of the present study was to find out the concentrations of different Volatile Organic Compounds (VOCs) in both outdoor and indoor locations from six different schools in Brisbane.