174 resultados para Ambulatory surgical procedures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Individuals with limb amputation fitted with conventional socket-suspended prostheses often experience socket related discomfort leading to a significant decrease in quality of life. Most of these concerns can be overcome by surgical techniques enabling bone-anchored prostheses. In this case, the prosthesis is attached directly to the residual skeleton through a percutaneous implant (e.g., screw type fixation, press-fit implant).[46, 48, 51, 52, 77, 78] The aim of this study is to present the current advances in these surgical techniques worldwide with a strong focus on the current challenges. Methods The current advances will be extracted from a systematic literature review including approximately 40 articles. The outcomes measured will include the estimation of the population worldwide as well as the complications (e.g., infection, loosening, fractures, and breakage) and the benefits (e.g., functional outcomes, health-related quality of life).[5-19, 51-53, 55, 57, 58, 62, 73, 79] Results The population of individuals fitted with a bone-anchored prosthesis is approximately 550 worldwide. Publications focusing on infection are sparse. However, the rate of superficial infection is estimated at 20%. Deep infection occurs rarely. Loosening and peri-prosthetic fractures are fairly uncommon. Breakage of implant parts occurs regularly mainly due to fall. All studies reported a significant improvement in functional level and overall quality of life. Conclusions Several commercial implants are in developments in Europe and US. The number of procedures is consistently growing worldwide. This technique might be primary way to fit a prosthesis to young and active amputees by 2025.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sustainable urban development, a major issue at global scale, will become more relevant according to population growth predictions in developed and developing countries. Societal and international recognition of sustainability concerns led to the development of specific tools and procedures, known as sustainability assessments/appraisals (SA). Their effectiveness however, considering that global quality life indicators have worsened since their introduction, has promoted a re-thinking of SA instruments. More precisely, Strategic Environmental Assessment (SEA), – a tool introduced in the European context to evaluate policies, plans, and programmes (PPPs), – is being reconsidered because of several features that seem to limit its effectiveness. Over time, SEA has evolved in response to external and internal factors dealing with technical, procedural, planning and governance systems thus involving a shift of paradigm from EIA-based SEAs (first generation protocols) towards more integrated approaches (second generation ones). Changes affecting SEA are formalised through legislation in each Member State, to guide institutions at regional and local level. Defining SEA effectiveness is quite difficult. Its’ capacity-building process appears quite far from its conclusion, even if any definitive version can be conceptualized. In this paper, we consider some European nations with different planning systems and SA traditions. After the identification of some analytical criteria, a multi-dimensional cluster analysis is developed on some case studies, to outline current weaknesses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Catheter ablation procedures for atrial fibrillation (AF) may frequently require long fluoroscopic times. We sought to undertake a review of radiation safety practice in our Cardiac Electrophysiology Laboratory and implement changes to minimize fluoroscopic doses. We also sought to compare the results with radiation doses for percutaneous coronary intervention (PCI) cases performed in our hospital. Methods: Fluoroscopic times and doses for AF ablation procedures performed by a single operator on a Philips Integris H3000 image-intensifier were analysed for 11-month period. Results were compared with all PCI procedures performed over a similar period by multiple operators on a Philips Integris Allura FD system. Comprehensive review of radiation practice in the Electrophysiology laboratory identified the potential to reduce pulse frame rates and doses, and to narrow the field of interest without impacting the performance of the procedure. These changes were implemented and results analysed after a further 11 months. Results: In the pre-intervention period 50 AF catheter ablations had a mean fluoroscopic time of 86.4 min and mean fluoroscopic dose 68.4 Gy/cm2. Post-intervention 75 procedures had a mean fluorosocopic time of 68.9 min (p < 0.0001) and mean dose of 14.3 Gy/cm2 (p < 0.0001) 128 PCI procedures had a mean combined fluoroscopic and image acquisition time of 10.0 min and mean total dose 38.8 Gy/cm2. Conclusions: Catheter ablation procedures for AF may require lengthy use of fluoroscopy but simple modifications to radiation practice can result in marked reductions in radiation dose that compare favourably with PCI case doses

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim Scoliosis is a common co-morbidity in Rett syndrome and spinal fusion may be recommended if severe. We investigated the impact of spinal fusion on survival and risk of severe lower respiratory tract infection in Rett syndrome. Method Data were ascertained from hospital medical records, the Australian Rett Syndrome Database, a longitudinal and population-based registry, and from the Australian Institute of Health and Welfare National Death Index database. Cox regression and generalized estimating equation models were used to estimate the effects of spinal surgery on survival and severe respiratory infection respectively in 140 females who developed severe scoliosis (Cobb angle ≥45°) before adulthood. Results After adjusting for mutation type and age of scoliosis onset, the rate of death was lower in the surgery group (hazard ratio [HR] 0.30, 95% confidence interval [CI] 0.12–0.74; p=0.009) compared to those without surgery. Rate of death was particularly reduced for those with early onset scoliosis (HR 0.17, 95% CI 0.06–0.52; p=0.002). There was some evidence to suggest that spinal fusion was associated with a reduction in risk of severe respiratory infection among those with early onset scoliosis (risk ratio 0.41, 95% CI 0.16–1.03; p=0.06). Interpretation With appropriate cautions, spinal fusion confers an advantage to life expectancy in Rett syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Physical therapy for youth with cerebral palsy (CP) who are ambulatory includes interventions to increase functional mobility and participation in physical activity (PA). Thus, reliable and valid measures are needed to document PA in youth with CP. OBJECTIVE The purpose of this study was to evaluate the inter-instrument reliability and concurrent validity of 3 accelerometer-based motion sensors with indirect calorimetry as the criterion for measuring PA intensity in youth with CP. METHODS Fifty-seven youth with CP (mean age=12.5 years, SD=3.3; 51% female; 49.1% with spastic hemiplegia) participated. Inclusion criteria were: aged 6 to 20 years, ambulatory, Gross Motor Function Classification System (GMFCS) levels I through III, able to follow directions, and able to complete the full PA protocol. Protocol activities included standardized activity trials with increasing PA intensity (resting, writing, household chores, active video games, and walking at 3 self-selected speeds), as measured by weight-relative oxygen uptake (in mL/kg/min). During each trial, participants wore bilateral accelerometers on the upper arms, waist/hip, and ankle and a portable indirect calorimeter. Intraclass coefficient correlations (ICCs) were calculated to evaluate inter-instrument reliability (left-to-right accelerometer placement). Spearman correlations were used to examine concurrent validity between accelerometer output (activity and step counts) and indirect calorimetry. Friedman analyses of variance with post hoc pair-wise analyses were conducted to examine the validity of accelerometers to discriminate PA intensity across activity trials. RESULTS All accelerometers exhibited excellent inter-instrument reliability (ICC=.94-.99) and good concurrent validity (rho=.70-.85). All accelerometers discriminated PA intensity across most activity trials. LIMITATIONS This PA protocol consisted of controlled activity trials. CONCLUSIONS Accelerometers provide valid and reliable measures of PA intensity among youth with CP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accepted Article Abstract Background: Liver diseases in Australia are estimated to affect 6 million people with a societal cost of $51 billion annually. Information about utilization of specialist hepatology care is critical in informing policy makers about the requirements for delivery of hepatology-related health care. Aims: This study examined etiology and severity of liver disease seen in a tertiary hospital hepatology clinic, as well as resource utilisation patterns. Methods: A longitudinal cohort study included consecutive patients booked in hepatology outpatient clinics during a 3 month period. Subsequent outpatient appointments for these patients over the following 12 months were then recorded. Results: During the initial 3 month period 1471 appointments were scheduled with a hepatologist, 1136 of which were attended. 21% of patients were “new cases”. Hepatitis B (HBV) was the most common disease etiology for new cases (37%). Advanced disease at presentation varied between etiology, with HBV (5%), Hepatitis C (HCV) (31%), non-alcoholic fatty liver disease (NAFLD) (46%) and alcoholic liver disease (ALD) (72%). Most patients (83%) attended multiple hepatology appointments, and a range of referrals patterns for procedures, investigations and other specialty assessments were observed. Conclusions: There is a high prevalence of HBV in new case referrals. Patients with HCV, NAFLD and ALD have a high prevalence of advanced liver disease at referral, requiring ongoing surveillance for development of decompensated liver disease and liver cancer. These findings that describe patterns of health service utilisation among patients with liver disease provide useful information for planning sustainable health service provision for this clinical population

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This paper reviews the apparatus used for deformation of bone fracture fixation plates during orthopaedic surgeries including surgical irons, pliers and bending press tools. This paper extends the review to various machineries in non-medical industries and adopts their suitability to clinics-related applications and also covers the evolution of orthopaedic bone plates. This review confirms that none of the studied machineries can be implemented for the deformation of bone fracture fixation plates during orthopaedic surgeries. In addition, this paper also presents the novel apparatus that are designed from scratch for this specific purpose. Several conceptual designs have been proposed and evaluated recently. It has been found that Computer Numerical Control (CNC) systems are not the golden solution to this problem and one needs to attempt to design the robotic arm system. A new design of robotic arm that can be used for facilitating orthopaedic surgeries is being completed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim and objectives To identify the prevalence that temperature reduced by more than 1°C from pre to post-procedure in a sample of non-anaesthetised patients undergoing procedures in a cardiac catheterisation laboratory. Background Advances in medical technology are minimising the invasiveness of diagnostic tests and treatments for disease, which is correspondingly increasing the number of medical procedures performed without sedation or anaesthesia. Procedural areas in which medical procedures are performed without anaesthesia are typically kept at a cool temperature for staff comfort. As such, there is a need to inform nursing practices in regard to the thermal management of non-anaesthetised patients undergoing procedures in surgical or procedural environments. Design Single-site observational study Methods Patients were included if they had undergone an elective procedure without sedation or anaesthesia in a cardiac catheterisation laboratory. Ambient room temperature was maintained between 18°C and 20°C. Passive warming with heated cotton blankets was applied. Nurses measured body temperature and thermal comfort before and after 342 procedures. Results Mean change in temperature was -0.08°C (Standard deviation 0.43). The reduction in temperature was more than 1°C after 11 procedures (3.2%). One patient whose temperature had reduced more than 1°C after their procedure reported thermal discomfort. A total of 12 patients were observed to be shivering post-procedure (3.6%). No demographic or clinical characteristics were associated with reduction in temperature of more than 1°C from pre to post-procedure. Conclusions Significant reduction in body temperature was rare in our sample of non-anaesthetised patients. Relevance to clinical practice Similar results would likely be found in other procedural contexts during procedures conducted in settings with comparable room temperatures where passive warming can also be applied with limited skin exposure.