208 resultados para utility grid operations


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recent growth of the coal seam gas industry has increased pressure on regional communities. Debate surrounding the industry is intense and a social licence to operate has yet to be granted to the industry in its entirety. This article presents an analysis of social issues surrounding the coal seam gas industry, making comparisons between two case studies: the Ranger and Jabiluka mines and the Yandicoogina mine. It presents the results of a desktop study, focussed on three topics: community identity; procedural justice and distributive justice, which provides a means for comparison and draws attention to central concerns. It is found that: power imbalances; changing community identities; potentially inequitable distributions of long term benefits and the process to distribute those benefits and negative perceptions of the industry as a whole serve to undermine the provision of a social licence to operate by communities and has the potential to impose significant negative impacts on companies within the industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Additional converters that are used to interface energy storage devices incur power losses as well as increased system cost and complexity. The need for additional converters can be eliminated if the grid side inverter can itself be effectively used as the interface for energy storage. This paper therefore proposes a technique whereby the grid side inverter can also be used as an interface to connect a supercapacitor energy storage for wind energy conversion systems. The proposed grid side inverter is formed by cascading a 3-level inverter and a 2-level inverter through a coupling transformer. The three-level inverter is the main inverter and it is powered by the rectified output of the wind turbine coupled AC generator while the 2-level auxiliary inverter is connected to the super capacitor bank that is used to compensate short term power fluctuations. Novel modulation and control techniques are proposed to address the problems associated with non-integer and dynamically-changing dc-link voltage ratio, which is caused by the random nature of wind. Simulation results are presented to verify the efficacy of the proposed system in suppressing short term wind power fluctuations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a novel concept of Energy Storage System (ESS) interfacing with the grid side inverter in wind energy conversion systems. The inverter system used here is formed by cascading a 2-level inverter and a three level inverter through a coupling transformer. The constituent inverters are named as the “main inverter” and the “auxiliary inverter” respectively. The main inverter is connected with the rectified output of the wind generator while the auxiliary inverter is attached to a Battery Energy Storage System (BESS). The BESS ensures constant power dispatch to the grid irrespective of change in wind condition. Furthermore, this unique combination of BESS and inverter eliminates the need of additional dc-dc converters. Novel modulation and control techniques are proposed to address the problem of non-integer, dynamically-changing dc-link voltage ratio, which is due to random wind changes. Strategies used to handle auxiliary inverter dc-link voltage imbalances and controllers used to charge batteries at different rates are explained in detail. Simulation results are presented to verify the efficacy of the proposed modulation and control techniques in suppressing random wind power fluctuations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper explores the possibility of connecting two Wind Turbine Generators (WTG) to the grid using a single three level inverter. In the proposed system the rectified output of one WTG is connected across the upper dc-link capacitor of a standard diode clamped three level inverter. Similarly the rectified output of the other WTG is connected across the lower capacitor. This particular combination has several advantages such as, direct connection to the grid, reduced parts count, improved reliability and high power capacity. However, the major problem in the proposed system is the imminent imbalance of dc-link voltages. Under such conditions conventional modulation methods fail to produce desired voltage and current waveforms. A detailed analysis on this issue and a novel space vector modulation method, as the solution, are proposed in this paper. To track the Maximum power point of each WTG a power sharing algorithm is proposed. Simulation results are presented to attest the efficacy of the proposed system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper explores a new breed of energy storage system interfacing for grid connected photovoltaic (PV) systems. The proposed system uses the popular dual inverter topology in which one inverter is supplied by a PV cell array and the other by a Battery Energy Storage System (BESS). The resulting conversion structure is controlled in a way that both demand matching and maximum power point tracking of the PV cell array are performed simultaneously. This dual inverter topology can produces 2, 3, 4 and 5 level inverter voltage waveforms at the dc-link voltage ratios of 0:1, 1:1, 2:1 and 3:2 respectively. Since the output voltage of the PV cell array and the battery are uncorrelated and dynamically change, the resulting dc-link voltage ratio can take non-integer values as well. These noninteger dc-link voltage ratios produce unevenly distributed space vectors. Therefore, the main issue with the proposed system is the generation of undistorted current even in the presence of unevenly distributed and dynamically changing space vectors. A modified space vector modulation method is proposed in this paper to address this issue and its efficacy is proved by simulation results. The ability of the proposed system to act as an active power source is also verified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poor mine water management can lead to corporate, environmental and social risks. These risks become more pronounced as mining operations move into areas of water scarcity and/or increase climatic variability while also managing increased demand, lower ore grades and increased strip ratios. Therefore, it is vital that mine sites better understand these risks in order to implement management practices to address them. Systems models provide an effective approach to understand complex networks, particularly across multiple scales. Previous work has represented mine water interactions using systems model on a mine site scale. Here, we expand on that work by present an integrated tool that uses a systems modeling approach to represent mine water interactions on a site and regional scale and then analyses the risks associated with events stemming from those interactions. A case study is presented to represent three indicative corporate, environmental and social risks associated with a mine site that exists in a water scarce region. The tool is generic and flexible, and can be used in many scenarios to provide significant potential utility to the mining industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Z-source inverter based grid-interface for a variable-speed wind turbine connected to a permanent magnet synchronous generator is proposed. A control system is designed to harvest maximum wind energy under varied wind conditions with the use of the permanent magnet synchronous generator, diode-rectifier and Z-source inverter. Control systems for speed regulation of the generator and for DC- and AC- sides of the Z-source inverter are investigated using computer simulations and laboratory experiments. Simulation and experimental results verify the efficacy of the proposed approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lower airway inflammation is generally classified as eosinophilic or neutrophilic. In conditions where eosinophilic inflammation predominates such as asthma in children, corticosteroids are usually beneficial. Traditionally, lower airway eosinophilia is measured using cellular count (through bronchoalveolar lavage or induced sputum). Both methods have limited applicability in children. When instruments to measure fractional exhaled nitric oxide (FeNO) became available, it presented an attractive option as it provided a non-invasive method of measuring eosinophilic inflammation suitable for children and adult. Not surprisingly, proposals have been made that FeNO measurement can be clinically used in many scenarios including monitoring the response to anti-inflammatory medications, to verify the adherence to treatment, and to predict upcoming asthma exacerbations. This thesis addresses the utility of FeNO levels in various scenarios, specifically in relation to asthma control and cough, a contentious aspect of the diagnosis of asthma. The thesis consists of a series of systematic reviews (related to the main question) and original studies in children. The over-arching aim of the thesis is to determine if FeNO is a clinically useful tool in the management of asthma and common asthma symptoms. The specific aims of the thesis were, to: 1. Determine if children with asthma have more severe acute respiratory symptoms at presentation with an asthma exacerbation and at days 7, 10 and 14 using validated scales. We also examined if children with asthma were more likely to have a persistent cough on day 14 than children with protracted bronchitis and/or controls. 2. Evaluate the efficacy of tailoring asthma interventions based on sputum analysis in comparison to clinical symptoms (with or without spirometry/peak flow) for asthma related outcomes in children and adults. 3. Evaluate the efficacy of tailoring asthma interventions based on exhaled nitric oxide in comparison to clinical symptoms (with or without spirometry/peak flow) for asthma related outcomes in children and adults. 4. Determine if adjustment of asthma medications based on FeNO levels (compared to management based on clinical symptoms) reduces severe exacerbations in children with asthma. 5. Examine the relationship between FeNO and exercise induced broncho-constriction and cough in children The aims above are addressed in respective chapters and all but one has been published/submitted. A synopsis of the findings are: In study-1 (Aim 1), we found that children with protracted bronchitis had the most severe acute respiratory infection symptoms and higher percentage of respiratory morbidity at day 14 in comparison to children with asthma and healthy controls. The systematic review of study-2 (Aim 2) included 246 randomised adult participants (no children) with 221 completing the trials. In the meta-analysis, a significant reduction in number of participants who had one or more asthma exacerbations occurred when treatment was based on sputum eosinophils in comparison to clinical symptoms. In the systematic review of study-3 (Aim 3), we found no significant difference between the intervention group (treatment adjusted based on FeNO) and control group (treatment adjusted based on clinical symptoms) for the primary outcome of asthma exacerbations or for the other outcomes (clinical symptoms, FeNO level and spirometry). In post-hoc analysis, a significant reduction in mean final daily dose ICS per adult was found in the group where treatment was based on FeNO in comparison to clinical symptoms. In contrast, in the paediatric studies, there was a significant increase in ICS dose in the FeNO strategy arm. Thus, controversy remains of the benefit or otherwise of utilising exhaled nitric oxide (FeNO) in routine clinical practice. FeNO levels are dependent on atopy and none of the 7 published trials have considered atopic status in FeNO levels when medications were adjusted. In study-4 (Aim 4), 64 children with asthma were recruited. Their asthma medications were adjusted according to either FeNO levels or usual clinical care utilising a management hierarchy taking into account atopy. It was concluded that tailoring of asthma medications in accordance to FeNO levels (compared to usual management), taking into account atopy status, reduced the number of children with severe exacerbations. However, a FeNO-based strategy resulted in higher daily ICS doses and had no benefit on asthma control. In study-5 (Aim 5), 33 children with cough and 17 controls were recruited. They were randomised to undertake an exercise challenge on day 1, or dry powder mannitol challenge on day 1 (with alternative challenge being done on day 2). In addition, a 24 hour cough meter, skin prick test, capsaicin cough sensitivity test and cough diary were undertaken. The change in cough frequency post exercise was significantly increased in the children with cough. FeNO decreases post exercise regardless of whether EIB is present or not. Limitations in the studies were addressed in the respective chapters. In summary, the studies from this thesis have provided new information on: • The severity of respiratory symptoms was increased in the early phase of the asthma exacerbation but not in the later recovery phase when compared with controls. • The utility of FeNO in the management of children with asthma. • The relationship of FeNO, cough and EIB in children. • Systematic reviews on the efficacy of tailoring asthma interventions based on eosinophilic inflammatory markers (sputum analysis and FeNO) in comparison to clinical symptoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spatial data are now prevalent in a wide range of fields including environmental and health science. This has led to the development of a range of approaches for analysing patterns in these data. In this paper, we compare several Bayesian hierarchical models for analysing point-based data based on the discretization of the study region, resulting in grid-based spatial data. The approaches considered include two parametric models and a semiparametric model. We highlight the methodology and computation for each approach. Two simulation studies are undertaken to compare the performance of these models for various structures of simulated point-based data which resemble environmental data. A case study of a real dataset is also conducted to demonstrate a practical application of the modelling approaches. Goodness-of-fit statistics are computed to compare estimates of the intensity functions. The deviance information criterion is also considered as an alternative model evaluation criterion. The results suggest that the adaptive Gaussian Markov random field model performs well for highly sparse point-based data where there are large variations or clustering across the space; whereas the discretized log Gaussian Cox process produces good fit in dense and clustered point-based data. One should generally consider the nature and structure of the point-based data in order to choose the appropriate method in modelling a discretized spatial point-based data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Emergency sheltering is a temporary source of safety and support for people affected by disasters. People access emergency sheltering just prior to or soon after a disaster; therefore they are often scared, stressed, and/or experiencing loss/grief. The gathering of people in shelters also increases several environmental health risks. Therefore ensuring emergency shelters contain adequate facilities (permanent or temporary) and are well managed is essential in providing immediate support to disaster-affected communities and providing a level of assurance that the agencies involved are capable of supporting them through the recovery process. This paper will be presented by representatives of Australian Red Cross and Environmental Health Australia (Queensland), which both have an interest in emergency sheltering in Queensland. The paper will cover the development, content and application of the ‘Preferred Sheltering Practices for Emergency Sheltering in Australia’ and the roles of various organisations in relation to emergency sheltering. The importance of or- ganisational collaboration will also be discussed, with a focus on the experience of the two organisations fol- lowing the 2011 floods in Queensland and how they are collaborating to improve future operations in evacu- ation centres, which are a common form of emergency sheltering in Queensland. The organisations are con- tinuing to work together with the ultimate goal of improving services to disaster-affected communities and supporting such communities to start the recovery process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis introduces advanced Demand Response algorithms for residential appliances to provide benefits for both utility and customers. The algorithms are engaged in scheduling appliances appropriately in a critical peak day to alleviate network peak, adverse voltage conditions and wholesale price spikes also reducing the cost of residential energy consumption. Initially, a demand response technique via customer reward is proposed, where the utility controls appliances to achieve network improvement. Then, an improved real-time pricing scheme is introduced and customers are supported by energy management schedulers to actively participate in it. Finally, the demand response algorithm is improved to provide frequency regulation services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of offshore oil and gas fields require the placement of different equipment on the sea floor. This is done by deploying the equipment from vessels operating in dynamic positioning on the surface. The deployment operation has different phases, and in higher sea states, it may require wave-load synchronization, when the load is going through the splash zone, and heave compensation when the load is close to the sea floor. In this paper, we analyse the performance of a particular type of hardware operating in a heave compensation mode. We derive a comprehensive model, analyse limits of performance and evaluate a control strategy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Housing affordability and sustainable development are not polarised ideologies as both are necessary with increasing urbanisation. We must bridge the gap between current median house pricing and target affordable house pricing whilst pursuing sustainability. This paper examines the potential of initial construction cost and ongoing utilities and transport cost reduction through the integration of sustainable housing design and transit oriented development principles in a Commuter Energy and Building Utilities System (CEBUS). It also introduces current research on the development of a Dynamic Simulation Model for CEBUS applications in the Australian property development and construction industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A framework supporting the systematic development of safety cases for Unmanned Aircraft System (UAS) operations in a broad range of civil and commercial applications is presented. The case study application is the use of UAS for disaster response. In those States where regulations do not preclude UAS operations altogether, approvals for UAS operations can be granted on a case-by-case basis contingent on the provision of a safety case acceptable to the relevant National Airworthiness Authority (NAA). A safety case for UAS operations must show how the risks associated with the hazards have been managed to an acceptable level. The foundational components necessary for structuring and assessing these safety cases have not yet been proposed. Barrier-bow-tie models are used in this paper to structure the safety case for the two primary hazards of 1) a ground impact, and 2) a Mid-Air Collision (MAC). The models establish the set of Risk Control Variables (RCVs) available to reduce the risk. For the ground-impact risk model, seven RCVs are identified which in combination govern the probability of an accident. Similarly, ten RCVs are identified within the MAC model. The effectiveness of the RCVs and how they can implemented in terms of processes, policies, devices, practices, or other actions for each of the case-study applications are discussed. The framework presented can provide for the more systematic and consistent regulation of UAS through a "safety target" approach.