356 resultados para Weak State
Resumo:
In November 1999, the Queensland Health (QH) Transition to Practice Nurse Education Program - Intensive Care (TPNEP-IC) was initiated in QH Intensive Care Units (ICUs) across Queensland. This 12-month, state-wide, workplace based education program has set minimum standards for intensive care nursing education and therefore minimum standards for intensive care nursing practice in QH. In the 12 years of operation, 824 nurses have completed TPNEP-IC, 761 achieving academic credit status and 453 utilising this academic credit status to undertake postgraduate study in critical/intensive care nursing at three Queensland universities. These outcomes were achieved through the appointment of nurse educators within ICUs who, through a united and strong commitment to this state-wide approach formed collaborative professional networks, which resulted in the development, implementation and maintenance of the program. Furthermore, these networks enabled a framework of support for discussion and dissemination of evidence based practice, to endorse quality processes for TPNEP-IC and to nurture leadership potential among educators. Challenges to overcome included obtaining adequate resources to support all aspects of the program, gaining local management and administrative support, and embedding TPNEP-IC within ICU culture. The 12 years of operation of the program have demonstrated its long term sustainability. The program is being launched through a new blended learning approach utilising e-learning strategies. To capitalise on the current success, a strong commitment by all stakeholders will be required to ensure the ongoing sustainability of the program.
Resumo:
This paper is concerned with certain of the characteristics of local social services, and their role in a restructuring Australian welfare state. I am particularly concerned with the distinctive gender characteristics of these organisations, because in comparison with most other organisations they have a feminised quality. This partly mirrors women's traditional role of undertaking the major part of the caring labour of society. However, simultaneously work in these organisation deviates from more traditional patterns where employed women occupy subordinate positions. In many community organisations, women occupy leadership roles. The analysis here is concerned with the apparently paradoxical nature of these organisations in their capacity to entrench traditional gender roles and to challenge these by allowing women to fill management positions. It is also concerned to examine whether changes that have been occurring in the community services sector over the last two decades are likely to enhance women's general position in the society, or diminish the power exercised by women. The paper draws in a preliminary way on a study of local services in the Hunter Region of NSW undertaken in the latter half of 1992. These preliminary findings are set against the broader picture of developments in the contemporary welfare state.
Resumo:
1. Like the Commonwealth Tax regime, state taxation legislation has now ballooned in size from the good old days when life and tax were relatively simple issues. 2. This case study of Queensland state taxation will examine the following taxes affecting churches and charities in this state: (a) Stamp Duty (b) Land Tax; and (c) Local Authority Rates 3. Each type of tax will be considered in turn. A brief legislative history of the statutory instruments governing these taxes will be given with a closer examination of the present schemes. Relevant judicial pronouncements will be considered and some open discussion of real life examples. 4. It is submitted that the regular donors to our worthy charities and the dedicated weekly churchgoers would have absolutely no idea: (a) that indirectly the value of their donations and weekly offerings are increasingly being eroded by the imposts of Government not only in terms of the amounts of those imposts but the enormous administrative burden of coping with the legislation; (b) of the complexity of the taxation legislation affecting their churches and charities; or (c) that their churches and charities are even paying taxes.
Resumo:
Non-state insurgent actors are too weak to compel powerful adversaries to their will, so they use violence to coerce. A principal objective is to grow and sustain violent resistance to the point that it either militarily challenges the state, or more commonly, generates unacceptable political costs. To survive, insurgents must shift popular support away from the state and to grow they must secure it. State actor policies and actions perceived as illegitimate and oppressive by the insurgent constituency can generate these shifts. A promising insurgent strategy is to attack states in ways that lead angry publics and leaders to discount the historically established risks and take flawed but popular decisions to use repressive measures. Such decisions may be enabled by a visceral belief in the power of coercion and selective use of examples of where robust measures have indeed suppressed resistance. To avoid such counterproductive behaviours the cases of apparent 'successful repression' must be understood. This thesis tests whether robust state action is correlated with reduced support for insurgents, analyses the causal mechanisms of such shifts and examines whether such reduction is because of compulsion or coercion? The approach is founded on prior research by the RAND Corporation which analysed the 30 insurgencies most recently resolved worldwide to determine factors of counterinsurgent success. This new study first re-analyses their data at a finer resolution with new queries that investigate the relationship between repression and insurgent active support. Having determined that, in general, repression does not correlate with decreased insurgent support, this study then analyses two cases in which the data suggests repression seems likely to be reducing insurgent support: the PKK in Turkey and the insurgency against the Vietnamese-sponsored regime after their ousting of the Khmer Rouge. It applies 'structured-focused' case analysis with questions partly built from the insurgency model of Leites and Wolf, who are associated with the advocacy of US robust means in Vietnam. This is thus a test of 'most difficult' cases using a 'least likely' test model. Nevertheless, the findings refute the deterrence argument of 'iron fist' advocates. Robust approaches may physically prevent effective support of insurgents but they do not coercively deter people from being willing to actively support the insurgency.
Resumo:
Efficient management of domestic wastewater is a primary requirement for human well being. Failure to adequately address issues of wastewater collection, treatment and disposal can lead to adverse public health and environmental impacts. The increasing spread of urbanisation has led to the conversion of previously rural land into urban developments and the more intensive development of semi urban areas. However the provision of reticulated sewerage facilities has not kept pace with this expansion in urbanisation. This has resulted in a growing dependency on onsite sewage treatment. Though considered only as a temporary measure in the past, these systems are now considered as the most cost effective option and have become a permanent feature in some urban areas. This report is the first of a series of reports to be produced and is the outcome of a research project initiated by the Brisbane City Council. The primary objective of the research undertaken was to relate the treatment performance of onsite sewage treatment systems with soil conditions at site, with the emphasis being on septic tanks. This report consists of a ‘state of the art’ review of research undertaken in the arena of onsite sewage treatment. The evaluation of research brings together significant work undertaken locally and overseas. It focuses mainly on septic tanks in keeping with the primary objectives of the project. This report has acted as the springboard for the later field investigations and analysis undertaken as part of the project. Septic tanks still continue to be used widely due to their simplicity and low cost. Generally the treatment performance of septic tanks can be highly variable due to numerous factors, but a properly designed, operated and maintained septic tank can produce effluent of satisfactory quality. The reduction of hydraulic surges from washing machines and dishwashers, regular removal of accumulated septage and the elimination of harmful chemicals are some of the practices that can improve system performance considerably. The relative advantages of multi chamber over single chamber septic tanks is an issue that needs to be resolved in view of the conflicting research outcomes. In recent years, aerobic wastewater treatment systems (AWTS) have been gaining in popularity. This can be mainly attributed to the desire to avoid subsurface effluent disposal, which is the main cause of septic tank failure. The use of aerobic processes for treatment of wastewater and the disinfection of effluent prior to disposal is capable of producing effluent of a quality suitable for surface disposal. However the field performance of these has been disappointing. A significant number of these systems do not perform to stipulated standards and quality can be highly variable. This is primarily due to houseowner neglect or ignorance of correct operational and maintenance procedures. The other problems include greater susceptibility to shock loadings and sludge bulking. As identified in literature a number of design features can also contribute to this wide variation in quality. The other treatment processes in common use are the various types of filter systems. These include intermittent and recirculating sand filters. These systems too have their inherent advantages and disadvantages. Furthermore as in the case of aerobic systems, their performance is very much dependent on individual houseowner operation and maintenance practices. In recent years the use of biofilters has attracted research interest and particularly the use of peat. High removal rates of various wastewater pollutants have been reported in research literature. Despite these satisfactory results, leachate from peat has been reported in various studies. This is an issue that needs further investigations and as such biofilters can still be considered to be in the experimental stage. The use of other filter media such as absorbent plastic and bark has also been reported in literature. The safe and hygienic disposal of treated effluent is a matter of concern in the case of onsite sewage treatment. Subsurface disposal is the most common and the only option in the case of septic tank treatment. Soil is an excellent treatment medium if suitable conditions are present. The processes of sorption, filtration and oxidation can remove the various wastewater pollutants. The subsurface characteristics of the disposal area are among the most important parameters governing process performance. Therefore it is important that the soil and topographic conditions are taken into consideration in the design of the soil absorption system. Seepage trenches and beds are the common systems in use. Seepage pits or chambers can be used where subsurface conditions warrant, whilst above grade mounds have been recommended for a variety of difficult site conditions. All these systems have their inherent advantages and disadvantages and the preferable soil absorption system should be selected based on site characteristics. The use of gravel as in-fill for beds and trenches is open to question. It does not contribute to effluent treatment and has been shown to reduce the effective infiltrative surface area. This is due to physical obstruction and the migration of fines entrained in the gravel, into the soil matrix. The surface application of effluent is coming into increasing use with the advent of aerobic treatment systems. This has the advantage that treatment is undertaken on the upper soil horizons, which is chemically and biologically the most effective in effluent renovation. Numerous research studies have demonstrated the feasibility of this practice. However the overriding criteria is the quality of the effluent. It has to be of exceptionally good quality in order to ensure that there are no resulting public health impacts due to aerosol drift. This essentially is the main issue of concern, due to the unreliability of the effluent quality from aerobic systems. Secondly, it has also been found that most householders do not take adequate care in the operation of spray irrigation systems or in the maintenance of the irrigation area. Under these circumstances surface disposal of effluent should be approached with caution and would require appropriate householder education and stringent compliance requirements. However despite all this, the efficiency with which the process is undertaken will ultimately rest with the individual householder and this is where most concern rests. Greywater too should require similar considerations. Surface irrigation of greywater is currently being permitted in a number of local authority jurisdictions in Queensland. Considering the fact that greywater constitutes the largest fraction of the total wastewater generated in a household, it could be considered to be a potential resource. Unfortunately in most circumstances the only pretreatment that is required to be undertaken prior to reuse is the removal of oil and grease. This is an issue of concern as greywater can considered to be a weak to medium sewage as it contains primary pollutants such as BOD material and nutrients and may also include microbial contamination. Therefore its use for surface irrigation can pose a potential health risk. This is further compounded by the fact that most householders are unaware of the potential adverse impacts of indiscriminate greywater reuse. As in the case of blackwater effluent reuse, there have been suggestions that greywater should also be subjected to stringent guidelines. Under these circumstances the surface application of any wastewater requires careful consideration. The other option available for the disposal effluent is the use of evaporation systems. The use of evapotranspiration systems has been covered in this report. Research has shown that these systems are susceptible to a number of factors and in particular to climatic conditions. As such their applicability is location specific. Also the design of systems based solely on evapotranspiration is questionable. In order to ensure more reliability, the systems should be designed to include soil absorption. The successful use of these systems for intermittent usage has been noted in literature. Taking into consideration the issues discussed above, subsurface disposal of effluent is the safest under most conditions. This is provided the facility has been designed to accommodate site conditions. The main problem associated with subsurface disposal is the formation of a clogging mat on the infiltrative surfaces. Due to the formation of the clogging mat, the capacity of the soil to handle effluent is no longer governed by the soil’s hydraulic conductivity as measured by the percolation test, but rather by the infiltration rate through the clogged zone. The characteristics of the clogging mat have been shown to be influenced by various soil and effluent characteristics. Secondly, the mechanisms of clogging mat formation have been found to be influenced by various physical, chemical and biological processes. Biological clogging is the most common process taking place and occurs due to bacterial growth or its by-products reducing the soil pore diameters. Biological clogging is generally associated with anaerobic conditions. The formation of the clogging mat provides significant benefits. It acts as an efficient filter for the removal of microorganisms. Also as the clogging mat increases the hydraulic impedance to flow, unsaturated flow conditions will occur below the mat. This permits greater contact between effluent and soil particles thereby enhancing the purification process. This is particularly important in the case of highly permeable soils. However the adverse impacts of the clogging mat formation cannot be ignored as they can lead to significant reduction in the infiltration rate. This in fact is the most common cause of soil absorption systems failure. As the formation of the clogging mat is inevitable, it is important to ensure that it does not impede effluent infiltration beyond tolerable limits. Various strategies have been investigated to either control clogging mat formation or to remediate its severity. Intermittent dosing of effluent is one such strategy that has attracted considerable attention. Research conclusions with regard to short duration time intervals are contradictory. It has been claimed that the intermittent rest periods would result in the aerobic decomposition of the clogging mat leading to a subsequent increase in the infiltration rate. Contrary to this, it has also been claimed that short duration rest periods are insufficient to completely decompose the clogging mat, and the intermediate by-products that form as a result of aerobic processes would in fact lead to even more severe clogging. It has been further recommended that the rest periods should be much longer and should be in the range of about six months. This entails the provision of a second and alternating seepage bed. The other concepts that have been investigated are the design of the bed to meet the equilibrium infiltration rate that would eventuate after clogging mat formation; improved geometry such as the use of seepage trenches instead of beds; serial instead of parallel effluent distribution and low pressure dosing of effluent. The use of physical measures such as oxidation with hydrogen peroxide and replacement of the infiltration surface have been shown to be only of short-term benefit. Another issue of importance is the degree of pretreatment that should be provided to the effluent prior to subsurface application and the influence exerted by pollutant loadings on the clogging mat formation. Laboratory studies have shown that the total mass loadings of BOD and suspended solids are important factors in the formation of the clogging mat. It has also been found that the nature of the suspended solids is also an important factor. The finer particles from extended aeration systems when compared to those from septic tanks will penetrate deeper into the soil and hence will ultimately cause a more dense clogging mat. However the importance of improved pretreatment in clogging mat formation may need to be qualified in view of other research studies. It has also shown that effluent quality may be a factor in the case of highly permeable soils but this may not be the case with fine structured soils. The ultimate test of onsite sewage treatment system efficiency rests with the final disposal of effluent. The implication of system failure as evidenced from the surface ponding of effluent or the seepage of contaminants into the groundwater can be very serious as it can lead to environmental and public health impacts. Significant microbial contamination of surface and groundwater has been attributed to septic tank effluent. There are a number of documented instances of septic tank related waterborne disease outbreaks affecting large numbers of people. In a recent incident, the local authority was found liable for an outbreak of viral hepatitis A and not the individual septic tank owners as no action had been taken to remedy septic tank failure. This illustrates the responsibility placed on local authorities in terms of ensuring the proper operation of onsite sewage treatment systems. Even a properly functioning soil absorption system is only capable of removing phosphorus and microorganisms. The nitrogen remaining after plant uptake will not be retained in the soil column, but will instead gradually seep into the groundwater as nitrate. Conditions for nitrogen removal by denitrification are not generally present in a soil absorption bed. Dilution by groundwater is the only treatment available for reducing the nitrogen concentration to specified levels. Therefore based on subsurface conditions, this essentially entails a maximum allowable concentration of septic tanks in a given area. Unfortunately nitrogen is not the only wastewater pollutant of concern. Relatively long survival times and travel distances have been noted for microorganisms originating from soil absorption systems. This is likely to happen if saturated conditions persist under the soil absorption bed or due to surface runoff of effluent as a result of system failure. Soils have a finite capacity for the removal of phosphorus. Once this capacity is exceeded, phosphorus too will seep into the groundwater. The relatively high mobility of phosphorus in sandy soils have been noted in the literature. These issues have serious implications in the design and siting of soil absorption systems. It is not only important to ensure that the system design is based on subsurface conditions but also the density of these systems in given areas is a critical issue. This essentially involves the adoption of a land capability approach to determine the limitations of an individual site for onsite sewage disposal. The most limiting factor at a particular site would determine the overall capability classification for that site which would also dictate the type of effluent disposal method to be adopted.
Resumo:
In 2010, the State Library of Queensland (SLQ) donated their out-of-copyright Queensland images to Wikimedia Commons. One direct effect of publishing the collections at Wikimedia Commons is the ability of general audiences to participate and help the library in processing the images in the collection. This paper will discuss a project that explored user participation in the categorisation of the State Library of Queensland digital image collections. The outcomes of this project can be used to gain a better understanding of user participation that lead to improving access to library digital collections. Two techniques for data collection were used: documents analysis and interview. Document analysis was performed on the Wikimedia Commons monthly reports. Meanwhile, interview was used as the main data collection technique in this research. The data collected from document analysis was used to help the researchers to devise appropriate questions for interviews. The interviews were undertaken with participants who were divided into two groups: SLQ staff members and Wikimedians (users who participate in Wikimedia). The two sets of data collected from participants were analysed independently and compared. This method was useful for the researchers to understand the differences between the experiences of categorisation from both the librarians’ and the users’ perspectives. This paper will provide a discussion on the preliminary findings that have emerged from each group participant. This research provides preliminary information about the extent of user participation in the categorisation of SLQ collections in Wikimedia Commons that can be used by SLQ and other interested libraries in describing their digital content by their categorisations to improve user access to the collection in the future.
Resumo:
Trivium is a keystream generator for a binary additive synchronous stream cipher. It was selected in the final portfolio for the Profile 2 category of the eSTREAM project. The keystream generator is constructed using bit- based shift registers. In this paper we present an alternate representation of Trivium using word-based shift registers, with a word size of three bits. This representation is useful for determining cycles of internal state values. Under this representation it is clear that the state space can be partitioned into subspaces and that over some of these subspaces the state update function is effectively linear. The role of the initialization process is critical in ensuring the states used for generating keystream are updated nonlinearly at some point, as the state update function alone does not provide this.
Resumo:
This paper presents a maintenance optimisation method for a multi-state series-parallel system considering economic dependence and state-dependent inspection intervals. The objective function considered in the paper is the average revenue per unit time calculated based on the semi-regenerative theory and the universal generating function (UGF). A new algorithm using the stochastic ordering is also developed in this paper to reduce the search space of maintenance strategies and to enhance the efficiency of optimisation algorithms. A numerical simulation is presented in the study to evaluate the efficiency of the proposed maintenance strategy and optimisation algorithms. The simulation result reveals that maintenance strategies with opportunistic maintenance and state-dependent inspection intervals are more cost-effective when the influence of economic dependence and inspection cost is significant. The study further demonstrates that the optimisation algorithm proposed in this paper has higher computational efficiency than the commonly employed heuristic algorithms.
Resumo:
BACKGROUND/OBJECTIVES: This paper reports on the evaluation of the Smart Choices healthy food and drink supply strategy for Queensland schools (Smart Choices) implementation across the whole school environment in state government primary and secondary schools in Queensland, Australia. SUBJECTS/METHODS: Three concurrent surveys using different methods for each group of stakeholders that targeted all 1275 school Principals, all 1258 Parent and Citizens’ Associations (P&Cs) and a random sample of 526 tuckshop convenors throughout Queensland. Nine hundred and seventy-three Principals, 598 P&Cs and 513 tuckshop convenors participated with response rates of 78%, 48% and 98%, respectively. RESULTS: Nearly all Principals (97%), P&Cs (99%) and tuckshop convenors (97%) reported that their school tuckshop had implemented Smart Choices. The majority of Principals and P&Cs reported implementation, respectively, in: school breakfast programs (98 and 92%); vending machine stock (94 and 83%); vending machine advertising (85 and 84%); school events (87 and 88%); school sporting events (81 and 80%); sponsorship and advertising (93 and 84%); fundraising events (80 and 84%); and sporting clubs (73 and 75%). Implementation in curriculum activities, classroom rewards and class parties was reported, respectively, by 97%, 86% and 75% of Principals. Respondents also reported very high levels of understanding of Smart Choices and engagement of the school community. CONCLUSIONS: The results demonstrated that food supply interventions to promote nutrition across all domains of the school environment can be implemented successfully.
Resumo:
The Sudbury Basin is a non-cylindrical fold basin occupying the central portion of the Sudbury Impact Structure. The impact structure lends itself excellently to explore the structural evolution of continental crust containing a circular region of long-term weakness. In a series of scaled analogue experiments various model crustal configurations were shortened horizontally at a constant rate. In mechanically weakened crust, model basins formed that mimic several first-order structural characteristics of the Sudbury Basin: (1) asymmetric, non-cylindrical folding of the Basin, (2) structures indicating concentric shortening around lateral basin termini and (3) the presence of a zone of strain concentration near the hinge zones of model basins. Geometrically and kinematically this zone corresponds to the South Range Shear Zone of the Sudbury Basin. According to our experiments, this shear zone is a direct mechanical consequence of basin formation, rather than the result of thrusting following folding. Overall, the models highlight the structurally anomalous character of the Sudbury Basin within the Paleoproterozoic Eastern Penokean Orogen. In particular, our models suggest that the Basin formed by pure shear thickening of crust, whereas transpressive deformation prevailed elsewhere in the orogen. The model basin is deformed by thickening and non-cylindrical synformal buckling, while conjugate transpressive shear zones propagated away from its lateral tips. This is consistent with pure shear deformation of a weak circular inclusion in a strong matrix. The models suggest that the Sudbury Basin formed as a consequence of long-term weakening of the upper crust by meteorite impact.
Resumo:
This chapter reviews aspects of the challenge of reviewing and reforming Indonesian practice within state asset management law and policy specifically related to public housing, public buildings, parklands, and vacant land. A critical issue in beginning this review is how Indonesia currently conceptualizes the notion of asset governance and how this meaning is embodied in recent changes in law and policy and importantly in options for future change. This chapter discusses the potential complexities uniquely Indonesian characteristics such as decentralisation and regional autonomy regime, political history, and bureaucratic culture.
Resumo:
This paper proposes a new approach for state estimation of angles and frequencies of equivalent areas in large power systems with synchronized phasor measurement units. Defining coherent generators and their correspondent areas, generators are aggregated and system reduction is performed in each area of inter-connected power systems. The structure of the reduced system is obtained based on the characteristics of the reduced linear model and measurement data to form the non-linear model of the reduced system. Then a Kalman estimator is designed for the reduced system to provide an equivalent dynamic system state estimation using the synchronized phasor measurement data. The method is simulated on two test systems to evaluate the feasibility of the proposed method.