356 resultados para THERMAL PERFORMANCE


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A range of influences, both technical and organisational, has encouraged the wide spread adoption of Enterprise Systems (ES). Nevertheless, there is a growing consensus that Enterprise Systems have in many cases failed to provide expected benefits. The increasing role of, and dependency on ES (and IT in general), and the ‘uncertainty’ of these large investments, have created a strong need to monitor and measure ES performance. This paper reports on a research project aimed at deriving an ‘Enterprise Systems benefits measurement instrument’. The research seeks to identify how Enterprise Systems benefits can be usefully measured, with a ‘balance’ between qualitative and quantitative factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spaces without northerly orientations have an impact on the ‘energy behaviour’ of a building. This paper outlines possible energy savings and better performance achieved by different zenithal solar passive strategies (skylights, roof monitors and clerestory roof windows) and element arrangements across the roof in zones of cold to temperate climates typical of the central and central-southern Argentina. Analyses were undertaken considering daylighting, thermal and ventilation performances of the different strategies. The results indicate that heating,ventilation and lighting loads in spaces without an equator-facing facade can be significantly reduced by implementing solar passive strategies. In the thermal aspect, the solar saving fraction reached for the different strategies were averaged 43.16% for clerestories, 41.4% for roof monitors and 38.86% for skylights for a glass area of 9% to the floor area. The results also indicate average illuminance levels above 500 lux for the different clerestory and monitor arrangements, uniformity ratios of 0.66–0.82 for the most distributed arrangements and day-lighting factors between 11.78 and 20.30% for clear sky conditions, depending on the strategy. In addition, minimum air changes rates of 4 were reached for the most extreme conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

I am suspicious of tools without a purpose - tools that are not developed in response to a clearly defined problem. Of course tools without a purpose can still be useful. However the development of first generation CAD was seriously impeded because the solution came before the problem. We are in danger of repeating this mistake if we do not clarify the nature of the problem that we are trying to solve with the next generation of tools. Back in the 1980s I used to add a postscript slide at the end of CAD conference presentations and the applause would invariably turn to concern. The slide simple asked: can anyone remember what it was about design that needed aiding before we had computer aided design?