295 resultados para Radiotherapy, Image-Guided
Resumo:
The presence of air and bone interfaces makes the dose distribution for head and neck cancer treatments difficult to accurately predict. This study compared planning system dose calculations using the collapsed-cone convolution algorithm with EGSnrcMonte Carlo simulation results obtained using the Monte Carlo DICOMToolKit software, for one oropharynx, two paranasal sinus and three nodal treatment plans. The difference between median doses obtained from the treatment planning and Monte Carlo calculations was found to be greatest in two bilateral treatments: 4.8%for a retropharyngeal node irradiation and 6.7% for an ethmoid paranasal sinus treatment. These deviations in median dose were smaller for two unilateral treatments: 0.8% for an infraclavicular node irradiation and 2.8% for a cervical node treatment. Examination of isodose distributions indicated that the largest deviations between Monte Carlo simulation and collapsed-cone convolution calculations were seen in the bilateral treatments, where the increase in calculated dose beyond air cavities was most significant.
Resumo:
The ubiquity of multimodality in hypermedia environments is undeniable. Bezemer and Kress (2008) have argued that writing has been displaced by image as the central mode for representation. Given the current technical affordances of digital technology and user-friendly interfaces that enable the ease of multimodal design, the conspicuous absence of images in certain domains of cyberspace is deserving of critical analysis. In this presentation, I examine the politics of discourses implicit within hypertextual spaces, drawing textual examples from a higher education website. I critically examine the role of writing and other modes of production used in what Fairclough (1993) refers to as discourses of marketisation in higher education, tracing four pervasive discourses of teaching and learning in the current economy: i) materialization, ii) personalization, iii) technologisation, and iv) commodification (Fairclough, 1999). Each of these arguments is supported by the critical analysis of multimodal texts. The first is a podcast highlighting the new architectonic features of a university learning space. The second is a podcast and transcript of a university Open Day interview with prospective students. The third is a time-lapse video showing the construction of a new science and engineering precinct. These three multimodal texts contrast a final web-based text that exhibits a predominance of writing and the powerful absence or silencing of the image. I connect the weightiness of words and the function of monomodality in the commodification of discourses, and its resistance to the multimodal affordances of web-based technologies, and how this is used to establish particular sets of subject positions and ideologies through which readers are constrained to occupy. Applying principles of critical language study by theorists that include Fairclough, Kress, Lemke, and others whose semiotic analysis of texts focuses on the connections between language, power, and ideology, I demonstrate how the denial of image and the privileging of written words in the multimodality of cyberspace is an ideological effect to accentuate the dominance of the institution.
Resumo:
Teleradiology allows medical images to be transmitted over electronic networks for clinical interpretation, and for improved healthcare access, delivery and standards. Although, such remote transmission of the images is raising various new and complex legal and ethical issues, including image retention and fraud, privacy, malpractice liability, etc., considerations of the security measures used in teleradiology remain unchanged. Addressing this problem naturally warrants investigations on the security measures for their relative functional limitations and for the scope of considering them further. In this paper, starting with various security and privacy standards, the security requirements of medical images as well as expected threats in teleradiology are reviewed. This will make it possible to determine the limitations of the conventional measures used against the expected threats. Further, we thoroughly study the utilization of digital watermarking for teleradiology. Following the key attributes and roles of various watermarking parameters, justification for watermarking over conventional security measures is made in terms of their various objectives, properties, and requirements. We also outline the main objectives of medical image watermarking for teleradiology, and provide recommendations on suitable watermarking techniques and their characterization. Finally, concluding remarks and directions for future research are presented.
Resumo:
Purpose Arbitrary numbers of corneal confocal microscopy images have been used for analysis of corneal subbasal nerve parameters under the implicit assumption that these are a representative sample of the central corneal nerve plexus. The purpose of this study is to present a technique for quantifying the number of random central corneal images required to achieve an acceptable level of accuracy in the measurement of corneal nerve fiber length and branch density. Methods Every possible combination of 2 to 16 images (where 16 was deemed the true mean) of the central corneal subbasal nerve plexus, not overlapping by more than 20%, were assessed for nerve fiber length and branch density in 20 subjects with type 2 diabetes and varying degrees of functional nerve deficit. Mean ratios were calculated to allow comparisons between and within subjects. Results In assessing nerve branch density, eight randomly chosen images not overlapping by more than 20% produced an average that was within 30% of the true mean 95% of the time. A similar sampling strategy of five images was 13% within the true mean 80% of the time for corneal nerve fiber length. Conclusions The “sample combination analysis” presented here can be used to determine the sample size required for a desired level of accuracy of quantification of corneal subbasal nerve parameters. This technique may have applications in other biological sampling studies.
Resumo:
In 2010, the State Library of Queensland (SLQ) donated their out-of-copyright Queensland images to Wikimedia Commons. One direct effect of publishing the collections at Wikimedia Commons is the ability of general audiences to participate and help the library in processing the images in the collection. This paper will discuss a project that explored user participation in the categorisation of the State Library of Queensland digital image collections. The outcomes of this project can be used to gain a better understanding of user participation that lead to improving access to library digital collections. Two techniques for data collection were used: documents analysis and interview. Document analysis was performed on the Wikimedia Commons monthly reports. Meanwhile, interview was used as the main data collection technique in this research. The data collected from document analysis was used to help the researchers to devise appropriate questions for interviews. The interviews were undertaken with participants who were divided into two groups: SLQ staff members and Wikimedians (users who participate in Wikimedia). The two sets of data collected from participants were analysed independently and compared. This method was useful for the researchers to understand the differences between the experiences of categorisation from both the librarians’ and the users’ perspectives. This paper will provide a discussion on the preliminary findings that have emerged from each group participant. This research provides preliminary information about the extent of user participation in the categorisation of SLQ collections in Wikimedia Commons that can be used by SLQ and other interested libraries in describing their digital content by their categorisations to improve user access to the collection in the future.
Rotorcraft collision avoidance using spherical image-based visual servoing and single point features
Resumo:
This paper presents a reactive collision avoidance method for small unmanned rotorcraft using spherical image-based visual servoing. Only a single point feature is used to guide the aircraft in a safe spiral like trajectory around the target, whilst a spherical camera model ensures the target always remains visible. A decision strategy to stop the avoidance control is derived based on the properties of spiral like motion, and the effect of accurate range measurements on the control scheme is discussed. We show that using a poor range estimate does not significantly degrade the collision avoidance performance, thus relaxing the need for accurate range measurements. We present simulated and experimental results using a small quad rotor to validate the approach.
Resumo:
Treatment plans for conformal radiotherapy are based on an initial CT scan. The aim is to deliver the prescribed dose to the tumour, while minimising exposure to nearby organs. Recent advances make it possible to also obtain a Cone-Beam CT (CBCT) scan, once the patient has been positioned for treatment. A statistical model will be developed to compare these CBCT scans with the initial CT scan. Changes in the size, shape and position of the tumour and organs will be detected and quantified. Some progress has already been made in segmentation of prostate CBCT scans [1],[2],[3]. However, none of the existing approaches have taken full advantage of the prior information that is available. The planning CT scan is expertly annotated with contours of the tumour and nearby sensitive objects. This data is specific to the individual patient and can be viewed as a snapshot of spatial information at a point in time. There is an abundance of studies in the radiotherapy literature that describe the amount of variation in the relevant organs between treatments. The findings from these studies can form a basis for estimating the degree of uncertainty. All of this information can be incorporated as an informative prior into a Bayesian statistical model. This model will be developed using scans of CT phantoms, which are objects with known geometry. Thus, the accuracy of the model can be evaluated objectively. This will also enable comparison between alternative models.
Resumo:
Cloud computing allows for vast computational resources to be leveraged quickly and easily in bursts as and when required. Here we describe a technique that allows for Monte Carlo radiotherapy dose calculations to be performed using GEANT4 and executed in the cloud, with relative simulation cost and completion time evaluated as a function of machine count. As expected, simulation completion time decreases as 1=n for n parallel machines, and relative simulation cost is found to be optimal where n is a factor of the total simulation time in hours. Using the technique, we demonstrate the potential usefulness of cloud computing as a solution for rapid Monte Carlo simulation for radiotherapy dose calculation without the need for dedicated local computer hardware as a proof of principal. Funding source Cancer Australia (Department of Health and Ageing) Research Grant 614217
Resumo:
Purpose: To determine whether uniform guidelines and training in the stabilization and formation of thermoplastic shells can improve the reproducibility of set-up for Head and Neck cancer patients. Methods and materials: Image based measurements of the planning and treatment positions for 35 head and neck cancer patients undergoing radical radiotherapy were analysed to provide a baseline of the reproducibility of thermoplastic immobilization. Radiation therapists (RT) were surveyed to establish a perception of their confidence in thermoplastic procedures. An evidence based staff training program was created and implemented. Set-up reproduction and staff perception were reviewed to measure the impact of the training program. Results: The mean (SD) 3D vectors of anatomical displacement, measured on the patient images, improved from 4.64 (2.03) for the baseline group compared to 3.02 (1.65) following training (p < 0.01). The proportion of 3D displacements of patient data exceeding 5 mm 3D vector was decreased from 37.1% to 5.7% (p < 0.001) and the 3 mm vector from 85.7% to 42.9% (p < 0.001). The post-training survey scores demonstrated improved confidence in reproducibility of set-up for head and neck patients. Conclusion: The Thermoplastic Shells Training Program has been found to improve the treatment reproducibility for head and neck radiation therapy patients. Uniform guidelines have increased RT confidence in thermoplastic procedures.
Resumo:
There is a growing interest in the use of megavoltage cone-beam computed tomography (MV CBCT) data for radiotherapy treatment planning. To calculate accurate dose distributions, knowledge of the electron density (ED) of the tissues being irradiated is required. In the case of MV CBCT, it is necessary to determine a calibration-relating CT number to ED, utilizing the photon beam produced for MV CBCT. A number of different parameters can affect this calibration. This study was undertaken on the Siemens MV CBCT system, MVision, to evaluate the effect of the following parameters on the reconstructed CT pixel value to ED calibration: the number of monitor units (MUs) used (5, 8, 15 and 60 MUs), the image reconstruction filter (head and neck, and pelvis), reconstruction matrix size (256 by 256 and 512 by 512), and the addition of extra solid water surrounding the ED phantom. A Gammex electron density CT phantom containing EDs from 0.292 to 1.707 was imaged under each of these conditions. The linear relationship between MV CBCT pixel value and ED was demonstrated for all MU settings and over the range of EDs. Changes in MU number did not dramatically alter the MV CBCT ED calibration. The use of different reconstruction filters was found to affect the MV CBCT ED calibration, as was the addition of solid water surrounding the phantom. Dose distributions from treatment plans calculated with simulated image data from a 15 MU head and neck reconstruction filter MV CBCT image and a MV CBCT ED calibration curve from the image data parameters and a 15 MU pelvis reconstruction filter showed small and clinically insignificant differences. Thus, the use of a single MV CBCT ED calibration curve is unlikely to result in any clinical differences. However, to ensure minimal uncertainties in dose reporting, MV CBCT ED calibration measurements could be carried out using parameter-specific calibration measurements.
Resumo:
Typical flow fields in a stormwater gross pollutant trap (GPT) with blocked retaining screens were experimentally captured and visualised. Particle image velocimetry (PIV) software was used to capture the flow field data by tracking neutrally buoyant particles with a high speed camera. A technique was developed to apply the Image Based Flow Visualization (IBFV) algorithm to the experimental raw dataset generated by the PIV software. The dataset consisted of scattered 2D point velocity vectors and the IBFV visualisation facilitates flow feature characterisation within the GPT. The flow features played a pivotal role in understanding gross pollutant capture and retention within the GPT. It was found that the IBFV animations revealed otherwise unnoticed flow features and experimental artefacts. For example, a circular tracer marker in the IBFV program visually highlighted streamlines to investigate specific areas and identify the flow features within the GPT.
Resumo:
Introduction: Clinical investigation has revealed a subgroup of head and neck cancers that are virally mediated. The relationship between nasopharyngeal cancer and Epstein Barr Virus (EBV) has long been established and more recently, the association between oropharyngeal cancer and Human Papillomavirus (HPV) has been revealed1,2 These cancers often present with nodal involvement and generally respond well to radiation treatment, evidenced by tumour regression1. This results in the need for treatment plan adaptation or re-planning in a subset of patients. Adaptive techniques allow the target region of the radiotherapy treatment plan to be altered in accordance with treatment-induced changes to ensure that under or over dosing does not occur3. It also assists in limiting potential overdosing of surrounding critical normal tissues4. We sought to identify a high-risk group based on nodal size to be evaluated in a future prospective adaptive radiotherapy trial. Method: Between 2005-2010, 121 patients with virally mediated, node positive nasopharyngeal (EBV positive) or oropharyngeal (HPV positive) cancers, receiving curative intent radiotherapy treatment were reviewed. Patients were analysed based on maximum size of the dominant node at diagnosis with a view to grouping them in varying risk categories to determine the need of re-planning. The frequency and timing of the re-planning scans were also evaluated. Results: Sixteen nasopharyngeal and 105 oropharyngeal tumours were reviewed. Twenty-five (21%) patients underwent a re-planning CT at a median of 22 (range, 0-29) fractions with 1 patient requiring re-planning prior to the commencement of treatment. Based on the analysis, patients were subsequently placed into risk categories; ≤35mm (Group 1), 36-45mm (Group 2), ≥46mm (Group 3). Re-planning CT’s were performed in Group 1- 8/68 (11.8%), Group 2- 4/28 (14.3%), Group 3- 13/25 (52%). Conclusion: In this series, patients with virally mediated head and neck cancer and nodal size > 46mm appear to be a high-risk group for the need of re-planning during a course of curative radiotherapy. This finding will now be tested in a prospective adaptive radiotherapy study. ‘Real World’ Implications: This research identifies predictive factors for those patients with virally mediated head and neck cancer that will benefit most from treatment adaptation. This will assist in minimising the side effects experienced by these patients thereby improving their quality of life after treatment.
Resumo:
Purpose: Virally mediated head and neck cancers (VMHNC) often present with nodal involvement, and are generally considered radioresponsive, resulting in the need for a re-planning CT during radiotherapy (RT) in a subset of patients. We sought to identify a high-risk group based on nodal size to be evaluated in a future prospective adaptive RT trial. Methodology: Between 2005-2010, 121 patients with virally-mediated, node positive nasopharyngeal (EBV positive) or oropharyngeal (HPV positive) cancers, receiving curative intent RT were reviewed. Patients were analysed based on maximum size of the dominant node with a view to grouping them in varying risk categories for the need of re-planning. The frequency and timing of the re-planning scans were also evaluated. Results: Sixteen nasopharyngeal and 105 oropharyngeal tumours were reviewed. Twenty-five (21%) patients underwent a re-planning CT at a median of 22 (range, 0-29) fractions with 1 patient requiring re-planning prior to the commencement of treatment. Based on the analysis, patients were subsequently placed into 3 groups; ≤35mm (Group 1), 36-45mm (Group 2), ≥46mm (Group 3). Re-planning CT’s were performed in Group 1- 8/68 (11.8%), Group 2- 4/28 (14.3%), Group 3- 13/25 (52%). Sample size did not allow statistical analysis to detect a significant difference or exclusion of a lack of difference between the 3 groups. Conclusion: In this series, patients with VMHNC and nodal size > 46mm appear to be a high-risk group for the need of re-planning during a course of definitive radiotherapy. This finding will now be tested in a prospective adaptive RT study.