614 resultados para Mechanical property improvement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Actuators with deliberately added compliant elements in the transmission system are often described as improving the safety of the actuator at the detriment of the performance. We show that our variant of the Series Elastic Actuator topology, the Velocity Sourced Series Elastic Actuator, has well defined performance characteristics that make for improvements in safety and performance over conventional high impedance actuators. The improvement in performance was principally achieved by having tight velocity control of the DC motor that acts as the mechanical power source for the actuator. Results for performance are given for point to point transition times, while results for safety are based on empirical assessment of the Head Injury Criterion during collisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ecological networks are often represented as utopian webs of green meandering through cities, across states, through regions and even across a country (Erickson, 2006, p.28; Fabos, 2004, p.326; Walmsley, 2006). While this may be an inspiring goal for some in developed countries, the reality may be somewhat different in developing countries. China, in its shift to urbanisation and suburbanisation, is also being persuaded to adjust its planning schemes according to these aspirational representations of green spaces (Yu et al, 2006, p.237; Zhang and Wang, 2006, p.455). The failure of other countries to achieve regional goals of natural and cultural heritage protection on the ground in this way (Peterson et al, 2007; Ryan et al, 2006; von Haaren and Reich, 2006) suggests that there may be flaws in the underpinning concepts that are widely circulated in North American and Western European literature (Jongman et al, 2004; Walmsley, 2006). In China, regional open space networks, regional green infrastructure or regional ecological corridors as we know them in the West, are also likely to be problematic, at least in the foreseeable future. Reasons supporting this view can be drawn from lessons learned from project experience in landscape planning and related fields of study in China and overseas. Implementation of valuable regional green space networks is problematic because: • the concept of region as a spatial unit for planning green space networks is ambiguous and undefinable for practical purposes; • regional green space networks traditionally require top down inter-governmental cooperation and coordination which are generally hampered by inequalities of influence between and within government agencies; • no coordinating body with funding powers exists for regional green space development and infrastructure authorities are still in transition from engineering authorities; • like other infrastructure projects, green space is likely to become a competitive rather than a complementary resource for city governments; • stable long-term management, maintenance and uses of green space networks must fit into a ‘family’ social structure rather than a ‘public good’ social structure, particularly as rural and urban property rights are being re-negotiated with city governments; and • green space provision is a performance indicator of urban improvement in cities within the city hierarchy and remains quantitatively-based (land area, tree number and per capita share) rather than qualitatively-based with local people as the focus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this paper is to explore the role of cross-functional teams in the alignment between system effectiveness and operational effectiveness after the implementation of enterprise information systems (EIS). In addition, it aims to explore the contribution of cross-functional teams to improvement in operational performance. ---------- Design/methodology/approach: The research uses a combination of qualitative and quantitative methods, in a two-stage methodological approach, to investigate the influence of cross-functional teams on the alignment between system effectiveness and operational effectiveness and the impact of the stated alignment on the improvement in operational performance. ---------- Findings: Initial findings suggest that factors stemming from system effectiveness and the performance objectives stemming from operational effectiveness are important and significantly well correlated factors that promote the alignment between the effectiveness of technological implementation and the effectiveness of operations. In addition, confirmatory factor analysis has been used to find the structural relationships and provide explanations for the stated alignment and the contribution of cross-functional teams to the improvement in operational performance. ---------- Research limitations/implications: The principal limitation of this study is its small sample size. ---------- Practical implications: Cross-functional teams have been used by many organisations as a way of involving expertise from different functional areas in the implementation of innovative technologies. An appropriate use of the dimensions that emerged from this research, in the context of cross-functional teams, will assist organisations to properly utilise cross-functional teams with the aim of improving operational performance. ---------- Originality/value: The paper presents a new approach to measure the effectiveness of EIS implementation by adding new dimensions to measure it.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - The paper examines the benefits of further diversifying a global portfolio of financial assets with New Zealand farm real estate (FRE). ---------- Design/methodology/approach - We compare efficient sets generated with and without farm real estate using portfolio theory. ---------- Findings - The results show that given the predominantly negative correlation between FRE and financial assets, the risk-return tradeoffs of portfolios of financial assets can be improved significantly. The diversification benefits measured in terms of risk reduction, return enhancement, and improvement in the Sharpe performance ratios are robust under a number of FRE risk-return scenarios as well as under high and low inflationary periods. Using 5- and 10-year rolling periods we also find that FRE is a consistent part of risk efficient portfolios. Consistent with the results reported in Lee and Stevenson (2006) for UK real estate the risk reduction benefits of diversifying with FRE are larger than the risk enhancement benefits. ---------- Practical implication - The results suggest that FRE takes on a consistent role of risk-reducer rather than a return-enhancer in a globally diversified portfolio. FRE appears to deserve more serious consideration by investment practitioners that it has been accorded in the past. Originality/value – The study examines the role of direct real estate in a globally diversified portfolio of financial assets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose – The purpose of this paper is to examine the buyer awareness and acceptance of environmental and energy efficiency measures in the New Zealand residential property markets. This study aims to provide a greater understanding of consumer behaviour in the residential property market in relation to green housing issues ---------- Design/methodology/approach – The paper is based on an extensive survey of Christchurch real estate offices and was designed to gather data on the factors that were considered important by buyers in the residential property market. The survey was designed to allow these factors to be analysed on a socio-economic basis and to compare buyer behaviour based on property values. ---------- Findings – The results show that regardless of income levels, buyers still consider that the most important factor in the house purchase decision is the location of the property and price. Although the awareness of green housing issues and energy efficiency in housing is growing in the residential property market, it is only a major consideration for young and older buyers in the high income brackets and is only of some importance for all other buyer sectors of the residential property market. Many of the voluntary measures introduced by Governments to improve the energy efficiency of residential housing are still not considered important by buyers, indicating that a more mandatory approach may have to be undertaken to improve energy efficiency in the established housing market, as these measures are not valued by the buyer. ---------- Originality/value – The paper confirms the variations in real estate buyer behaviour across the full range of residential property markets and the acceptance and awareness of green housing issues and measures. These results would be applicable to most established and transparent residential property markets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Ovine models are widely used in orthopaedic research. To better understand the impact of orthopaedic procedures computer simulations are necessary. 3D finite element (FE) models of bones allow implant designs to be investigated mechanically, thereby reducing mechanical testing. Hypothesis We present the development and validation of an ovine tibia FE model for use in the analysis of tibia fracture fixation plates. Material & Methods Mechanical testing of the tibia consisted of an offset 3-pt bend test with three repetitions of loading to 350N and return to 50N. Tri-axial stacked strain gauges were applied to the anterior and posterior surfaces of the bone and two rigid bodies – consisting of eight infrared active markers, were attached to the ends of the tibia. Positional measurements were taken with a FARO arm 3D digitiser. The FE model was constructed with both geometry and material properties derived from CT images of the bone. The elasticity-density relationship used for material property determination was validated separately using mechanical testing. This model was then transformed to the same coordinate system as the in vitro mechanical test and loads applied. Results Comparison between the mechanical testing and the FE model showed good correlation in surface strains (difference: anterior 2.3%, posterior 3.2%). Discussion & Conclusion This method of model creation provides a simple method for generating subject specific FE models from CT scans. The use of the CT data set for both the geometry and the material properties ensures a more accurate representation of the specific bone. This is reflected in the similarity of the surface strain results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Six Sigma provides a framework for quality improvement and business excellence. Introduced in the 1980s in manufacturing, the concept of Six Sigma has gained popularity in service organizations. After initial success in healthcare and banking, Six Sigma has gradually gained traction in other types of service industries, including hotels and lodging. Starwood Hotels and Resorts was the first hospitality giant to embrace Six Sigma. In 2001, Starwood adopted the method to develop innovative, customer-focused solutions and to transfer these solutions throughout the global organization. To analyze Starwood's use of Six Sigma, the authors collected data from articles, interviews, presentations and speeches published in magazines, newspapers and Web sites. This provided details to corroborate information, and they also made inferences from these sources. Financial metrics can explain the success of Six Sigma in any organization. There was no shortage of examples of Starwood's success resulting from Six Sigma project metrics uncovered during the research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis presents a study of the mechanical properties of thin films. The main aim was to determine the properties of sol-gel derived coatings. These films are used in a range of different applications and are known to be quite porous. Very little work has been carried out in this area and in order to study the mechanical properties of sol-gel films, some of the work was carried out on magnetron sputtered metal coatings in order to validate the techniques developed in this work. The main part of the work has concentrated on the development of various bending techniques to study the elastic modulus of the thin films, including both a small scale three-point bending, as well as a novel bi-axial bending technique based on a disk resting on three supporting balls. The bending techniques involve a load being applied to the sample being tested and the bending response to this force being recorded. These experiments were carried out using an ultra micro indentation system with very sensitive force and depth recording capabilities. By analysing the result of these forces and deflections using existing theories of elasticity, the elastic modulus may be determined. In addition to the bi-axial bending study, a finite element analysis of the stress distribution in a disk during bending was carried out. The results from the bi-axial bending tests of the magnetron sputtered films was confirmed by ultra micro indentation tests, giving information of the hardness and elastic modulus of the films. It was found that while the three point bending method gave acceptable results for uncoated steel substrates, it was very susceptible to slight deformations of the substrate. Improvements were made by more careful preparation of the substrates in order to avoid deformation. However the technique still failed to give reasonable results for coated specimens. In contrast, biaxial bending gave very reliable results even for very thin films and this technique was also found to be useful for determination of the properties of sol-gel coatings. In addition, an ultra micro indentation study of the hardness and elastic modulus of sol-gel films was conducted. This study included conventionally fired films as well as films ion implanted in a range of doses. The indentation tests showed that for implantation of H+ ions at doses exceeding 3x1016 ions/cm2, the mechanical properties closely resembled those of films that were conventionally fired to 450°C.