289 resultados para Excavating equipment
Resumo:
Introduction: Undergraduate students studying the Bachelor of Radiation Therapy at Queensland University of Technology (QUT) attend clinical placements in a number of department sites across Queensland. To ensure that the curriculum prepares students for the most common treatments and current techniques in use in these departments, a curriculum matching exercise was performed. Methods: A cross-sectional census was performed on a pre-determined “Snapshot” date in 2012. This was undertaken by the clinical education staff in each department who used a standardized proforma to count the number of patients as well as prescription, equipment, and technique data for a list of tumour site categories. This information was combined into aggregate anonymized data. Results: All 12 Queensland radiation therapy clinical sites participated in the Snapshot data collection exercise to produce a comprehensive overview of clinical practice on the chosen day. A total of 59 different tumour sites were treated on the chosen day and as expected the most common treatment sites were prostate and breast, comprising 46% of patients treated. Data analysis also indicated that intensity-modulated radiotherapy (IMRT) use is relatively high with 19.6% of patients receiving IMRT treatment on the chosen day. Both IMRT and image-guided radiotherapy (IGRT) indications matched recommendations from the evidence. Conclusion: The Snapshot method proved to be a feasible and efficient method of gathering useful
Resumo:
Widespread adoption by electricity utilities of Non-Conventional Instrument Transformers, such as optical or capacitive transducers, has been limited due to the lack of a standardised interface and multi-vendor interoperability. Low power analogue interfaces are being replaced by IEC 61850 9 2 and IEC 61869 9 digital interfaces that use Ethernet networks for communication. These ‘process bus’ connections achieve significant cost savings by simplifying connections between switchyard and control rooms; however the in-service performance when these standards are employed is largely unknown. The performance of real-time Ethernet networks and time synchronisation was assessed using a scale model of a substation automation system. The test bed was constructed from commercially available timing and protection equipment supplied by a range of vendors. Test protocols have been developed to thoroughly evaluate the performance of Ethernet networks and network based time synchronisation. The suitability of IEEE Std 1588 Precision Time Protocol (PTP) as a synchronising system for sampled values was tested in the steady state and under transient conditions. Similarly, the performance of hardened Ethernet switches designed for substation use was assessed under a range of network operating conditions. This paper presents test methods that use a precision Ethernet capture card to accurately measure PTP and network performance. These methods can be used for product selection and to assess ongoing system performance as substations age. Key findings on the behaviour of multi-function process bus networks are presented. System level tests were performed using a Real Time Digital Simulator and transformer protection relay with sampled value and Generic Object Oriented Substation Events (GOOSE) capability. These include the interactions between sampled values, PTP and GOOSE messages. Our research has demonstrated that several protocols can be used on a shared process bus, even with very high network loads. This should provide confidence that this technology is suitable for transmission substations.
Resumo:
As a result of growing evidence regarding the effects of environmental characteristics on the health and wellbeing of people in healthcare facilities (HCFs), more emphasis is being placed on, and more attention being paid to, the consequences of design choices in HCFs. Therefore, we have critically reviewed the implications of key indoor physical design parameters, in relation to their potential impact on human health and wellbeing. In addition, we discussed these findings within the context of the relevant guidelines and standards for the design of HCFs. A total of 810 abstracts, which met the inclusion criteria, were identified through a Pubmed search, and these covered journal articles, guidelines, books, reports and monographs in the studied area. Of these, 231 full publications were selected for this review. According to the literature, the most beneficial design elements were: single-bed patient rooms, safe and easily cleaned surface materials, sound-absorbing ceiling tiles, adequate and sufficient ventilation, thermal comfort, natural daylight, control over temperature and lighting, views, exposure and access to nature, and appropriate equipment, tools and furniture. The effects of some design elements, such as lighting (e.g. artificial lighting levels) and layout (e.g. decentralized versus centralized nurses’ stations), on staff and patients vary, and “the best design practice” for each HCF should always be formulated in co-operation with different user groups and a multi-professional design team. The relevant guidelines and standards should also be considered in future design, construction and renovations, in order to produce more favourable physical indoor environments in HCFs.
Resumo:
The "standard" procedure for calibrating the Vesuvio eV neutron spectrometer at the ISIS neutron source, forming the basis for data analysis over at least the last decade, was recently documented in considerable detail by the instrument’s scientists. Additionally, we recently derived analytic expressions of the sensitivity of recoil peak positions with respect to fight-path parameters and presented neutron–proton scattering results that together called in to question the validity of the "standard" calibration. These investigations should contribute significantly to the assessment of the experimental results obtained with Vesuvio. Here we present new results of neutron–deuteron scattering from D2 in the backscattering angular range (theata > 90 degrees) which are accompanied by a striking energy increase that violates the Impulse Approximation, thus leading unequivocally the following dilemma: (A) either the "standard" calibration is correct and then the experimental results represent a novel quantum dynamical effect of D which stands in blatant contradiction of conventional theoretical expectations; (B) or the present "standard" calibration procedure is seriously deficient and leads to artificial outcomes. For Case(A), we allude to the topic of attosecond quantumdynamical phenomena and our recent neutron scattering experiments from H2 molecules. For Case(B),some suggestions as to how the "standard" calibration could be considerably improved are made.
Resumo:
Alcohol-related driving is a longstanding, serious problem in China (Li, Xie, Nie, & Zhang, 2012). On 1st May, 2011 a national law was introduced to criminalize drunk driving, and imposed serious penalties including jail for driving with a blood alcohol level of above 80mg/100ml. This pilot study, undertaken a year after introduction of the law, sought traffic police officers’ perceptions of drink driving and the practice of breath alcohol testing (BAT) in a large city in Guangdong Province, southern China. A questionnaire survey and semi-structured interviews were used to gain an in-depth understanding of issues relevant to alcohol-related driving. Fifty-five traffic police officers were recruited for the survey and six traffic police officers with a variety of working experience including roadside alcohol breath testing, traffic crash investigation and police resourcing were interviewed individually. The officers were recruited by the first author with the assistance of the staff from Guangdong Institute of Public Health, Centre for Disease Control and Prevention (CDC). Interview participants reported three primary reasons why people drink and drive: 1) being prepared to take the chance of not being apprehended by police; 2) the strong traditional Chinese drinking culture; and 3) insufficient public awareness about the harmfulness of drink driving. Problems associated with the process of breath alcohol testing (BAT) were described and fit broadly into two categories: resourcing and avoiding detection. It was reported that there were insufficient traffic police officers to conduct routine traffic policing, including alcohol testing. Police BAT equipment was considered sufficient for routine traffic situations but not highway traffic operations. Local media and posters are used by the Public Security Bureau which is responsible for education about safe driving but participants thought that the education campaigns are limited in scope. Participants also described detection avoidance strategies used by drivers including: changing route; ignoring a police instruction to stop; staying inside the vehicle with windows and doors locked to avoid being tested; intentionally not performing breath tests correctly; and arguing with officers. This pilot study provided important insights from traffic police in one Chinese city which suggest there may be potential unintended effects of introducing more severe penalties including a range of strategies reportedly used by drivers to avoid detection. Recommendations for future research include a larger study to confirm these findings and examine the training and education of drivers; the focus and reach of publicity; and possible resource needs to support police enforcement.
Resumo:
The effects of small changes in flight-path parameters (primary and secondary flight paths, detector angles), and of displacement of the sample along the beam axis away from its ideal position, are examined for an inelastic time-of-flight (TOF) neutron spectrometer, emphasising the deep-inelastic regime. The aim was to develop a rational basis for deciding what measured shifts in the positions of spectral peaks could be regarded as reliable in the light of the uncertainties in the calibrated flight-path parameters. Uncertainty in the length of the primary or secondary flight path has the least effect on the positions of the peaks of H, D and He, which are dominated by the accuracy of the calibration of the detector angles. This aspect of the calibration of a TOF spectrometer therefore demands close attention to achieve reliable outcomes where the position of the peaks is of significant scientific interest and is discussed in detail. The corresponding sensitivities of the position of peak of the Compton profile, J(y), to flight-path parameters and sample position are also examined, focusing on the comparability across experiments of results for H, D and He. We show that positioning the sample to within a few mm of the ideal position is required to ensure good comparability between experiments if data from detectors at high forward angles are to be reliably interpreted.
An evaluation of the Australian Capital Territory Sexual Assault Reform Program (SARP): Final Report
Resumo:
In 2005 the Australian Capital Territory (ACT) Office of the Director of Public Prosecutions (DPP) and the Australian Federal Police (AFP) produced a report, Responding to sexual assault: The challenge of change (DPP & AFP 2005), which made 105 recommendations for reforming the way sexual offence cases are handled by the ACT’s criminal justice system. The Sexual Assault Reform Program (SARP) is one key initiative developed in response to these recommendations. Managed by the ACT Justice and Community Safety Directorate (JACS), SARP’s main objective is to improve aspects of the criminal justice system relating to: processes and support for victims of sexual offences as they progress through the system; attrition in sexual offence matters in the criminal justice system; and coordination and collaboration among the agencies involved. In November 2007 the ACT Attorney-General announced $4 million of funding for several SARP reforms. This funding provided for additional victim support staff; a dedicated additional police officer, prosecutor and legal policy officer; and an upgrade of equipment for the Supreme Court and Magistrates Court, including improvements in technology to assist witnesses in giving evidence, and the establishment of an off-site facility to allow witnesses to give evidence from a location outside of the court. In addition, the reform agenda included a number of legislative amendments that changed how evidence can be given by victims of sexual and family violence offences, children and other vulnerable witnesses. The primary objectives of these legislative changes are to provide an unintimidating, safe environment for vulnerable witnesses (including sexual offence complainants) to give evidence and to obtain prompt statements from witnesses to improve the quality of evidence captured (DPP 2009: 13). The current evaluation The funding for SARP reforms also provided for a preliminary evaluation of the reforms; this report outlines findings from the evaluation. The evaluation sought to address whether the program has met its key objectives: better support for victims, lower attrition rates and improved coordination and collaboration among agencies involved in administering SARP. The evaluation was conducted in two stages and involved a mixed-methods approach. During stage 1 key indicators for the evaluation were developed with stakeholders. During stage 2 quantitative data were collected by stakeholders and provided to the AIC for analysis. Qualitative interviews were also conducted with service delivery providers, and with a small number (n=5) of victim/survivors of sexual offences whose cases had recently been resolved in the ACT criminal justice system. The current evaluation is preliminary in nature. As the SARP reforms will take time to become entrenched within the ACT’s criminal justice system, some of the impacts of the reforms may not yet be evident. Nonetheless, this evaluation provides an insight into how well the SARP reforms have been implemented to date, as well as key areas that could be addressed in the future. Key findings from the preliminary evaluation are outlined briefly below.
Resumo:
Biomechanics involves research and analysis of the mechanisms of living organisms. This can be conducted on multiple levels and represents a continuum from the molecular, wherein biomaterials such as collagen and elastin are considered, to the tissue, organ and whole body level. Some simple applications of Newtonian mechanics can supply correct approximations on each level, but precise details demand the use of continuum mechanics. Sport biomechanics uses the scientific methods of mechanics to study the effects of forces on the sports performer and considers aspects of the behaviour of sports implements, equipment, footwear and surfaces. There are two main aims of sport biomechanics, that is, the reduction of injury and the improvement of performance (Bartlett, 1999). Aristotle (384-322 BC) wrote the first book on biomechanics, De Motu Animalium, translated as On the Movement of Animals. He saw animals' bodies as mechanical systems, but also pursued questions that might explain the physiological difference between imagining the performance of an action and actually doing it. Some simple examples of biomechanics research include the investigation of the forces that act on limbs, the aerodynamics of animals in flight, the hydrodynamics of objects moving through water and locomotion in general across all forms of life, from individual cells to whole organisms...
Resumo:
Long term exposure to vehicle emissions has been associated with harmful health effects. Children are amongst the most susceptible group and schools represent an environment where they can experience significant exposure to vehicle emissions. However, there are limited studies on children’s exposure to vehicle emissions in schools. The aim of this study was to quantify the concentration of organic aerosol and in particular, vehicle emissions that children are exposed to during school hours. Therefore an Aerodyne compact time-of-flight aerosol mass spectrometer (TOF-AMS) was deployed at five urban schools in Brisbane, Australia. The TOF-AMS enabled the chemical composition of the non- refractory (NR-PM1) to be analysed with a high temporal resolution to assess the concentration of vehicle emissions and other organic aerosols during school hours. At each school the organic fraction comprised the majority of NR-PM1 with secondary organic aerosols as the main constitute. At two of the schools, a significant source of the organic aerosol (OA) was slightly aged vehicle emissions from nearby highways. More aged and oxidised OA was observed at the other three schools, which also recorded strong biomass burning influences. Primary emissions were found to dominate the OA at only one school which had an O:C ratio of 0.17, due to fuel powered gardening equipment used near the TOF-AMS. The diurnal cycle of OA concentration varied between schools and was found to be at a minimum during school hours. The major organic component that school children were exposed to during school hours was secondary OA. Peak exposure of school children to HOA occurred during school drop off and pick up times. Unless a school is located near major roads, children are exposed predominately to regional secondary OA as opposed to local emissions during schools hours in urban environments.
Resumo:
Background: Changes in the roles of the contemporary pharmacist has seen a decline in the number and variety of extemporaneously compounded dosage forms. Pharmacy curricula reflect this change with a reduction in the emphasis on extemporaneous compounding practice. Aim: To elicit information about extemporaneously compounded dosage forms and perceptions of compounding practice from pharmacists and pharmacy students. Method: Self-administered surveys were mailed to 1063 pharmacists and offered online to 896 pharmacy undergraduates across the 4 years of a Bachelor of Pharmacy program in Queensland. Results: 382 (36%) pharmacists and 455 (51%) students completed the survey. Most pharmacists (96%) reported compounding a product in the 12 months prior to the survey, particularly semi-solids (89%) and liquids (64%) for external use. Most pharmacies (> 96%) owned basic compounding equipment, such as a slab and spatula, mortar and pestle, and cylindrical/conical measures. Half of the pharmacies used mechanical rather than electronic balances. Students expressed greater confidence in their ability to use basic compounding equipment and to perform basic compounding tasks as they progressed through the 4-year degree course. Pharmacists’ views on students’ ability to compound basic products at the end of their degree were generally similar to the proportion of final-year students who reported they could confidently complete the task. Conclusion: Despite a decline in extemporaneously compounded products in community pharmacy, pharmacy graduates need to be competent in compounding techniques.
Resumo:
This chapter introduces the principles of coring, including the objectives for taking a good core and the major factors that should be considered to ensure the collection of non disturbed, representative core samples. The chapter also provides an overview of the design, function, and operation of the main types of coring equipment that can be used to sample sediments from a variety of settings including lakes, the ocean, peat bogs, soils, and permafrost. The major advantages and disadvantages of each type of corer are also discussed.
Resumo:
The texture of agricultural crops changes during harvesting, post harvesting and processing stages due to different loading processes. There are different source of loading that deform agricultural crop tissues and these include impact, compression, and tension. Scanning Electron Microscope (SEM) method is a common way of analysing cellular changes of materials before and after these loading operations. This paper examines the structural changes of pumpkin peel and flesh tissues under mechanical loading. Compression and indentation tests were performed on peel and flesh samples. Samples structure were then fixed and dehydrated in order to capture the cellular changes under SEM. The results were compared with the images of normal peel and flesh tissues. The findings suggest that normal flesh tissue had bigger size cells, while the cellular arrangement of peel was smaller. Structural damage was clearly observed in tissue structure after compression and indentation. However, the damages that resulted from the flat end indenter was much more severe than that from the spherical end indenter and compression test. An integrated deformed tissue layer was observed in compressed tissue, while the indentation tests shaped a deformed area under the indenter and left the rest of the tissue unharmed. There was an obvious broken layer of cells on the walls of the hole after the flat end indentations, whereas the spherical indenter created a squashed layer all around the hole. Furthermore, the influence of loading was lower on peel samples in comparison with the flesh samples. The experiments have shown that the rate of damage on tissue under constant rate of loading is highly dependent on the shape of equipment. This fact and observed structural changes after loading underline the significance of deigning post harvesting equipments to reduce the rate of damage on agricultural crop tissues.
Resumo:
This article reports on the design and implementation of a Computer-Aided Die Design System (CADDS) for sheet-metal blanks. The system is designed by considering several factors, such as the complexity of blank geometry, reduction in scrap material, production requirements, availability of press equipment and standard parts, punch profile complexity, and tool elements manufacturing method. The interaction among these parameters and how they affect designers' decision patterns is described. The system is implemented by interfacing AutoCAD with the higher level languages FORTRAN 77 and AutoLISP. A database of standard die elements is created by parametric programming, which is an enhanced feature of AutoCAD. The greatest advantage achieved by the system is the rapid generation of the most efficient strip and die layouts, including information about the tool configuration.
Resumo:
In the decision-making of multi-area ATC (Available Transfer Capacity) in electricity market environment, the existing resources of transmission network should be optimally dispatched and coordinately employed on the premise that the secure system operation is maintained and risk associated is controllable. The non-sequential Monte Carlo simulation is used to determine the ATC probability density distribution of specified areas under the influence of several uncertainty factors, based on which, a coordinated probabilistic optimal decision-making model with the maximal risk benefit as its objective is developed for multi-area ATC. The NSGA-II is applied to calculate the ATC of each area, which considers the risk cost caused by relevant uncertainty factors and the synchronous coordination among areas. The essential characteristics of the developed model and the employed algorithm are illustrated by the example of IEEE 118-bus test system. Simulative result shows that, the risk of multi-area ATC decision-making is influenced by the uncertainties in power system operation and the relative importance degrees of different areas.
Resumo:
Objective: To examine the context of occupational health and safety related to blood-borne communicable diseases practice. Methods: A case study approach using qualitative semi-structured interviews with five key informants who represented different sectors of the beauty therapy industry in South Australia. Results: Four main themes were identified: (i) exposure to blood and blood-borne communicable diseases; (ii) prevention in practice; (iii) OH&S problems; and (iv) industry needs. Conclusion: Key OH&S issues in the beauty therapy industry include: power relationships between employers and employees, equipment costs, the need for more continuing education, and monitoring of practitioners. Implications: Economic constraints, continuing education, and government regulation of the beauty therapy industry are highlighted as significant areas for further consideration in addressing the OH&S needs of practitioners and their clients.