174 resultados para Contact equivalence


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new imaging methodology is described to visualise the post lens tear film (PLTF) during contact lens wear. A rotating-Scheimpflug camera in combination with sodium fluorescein allows evaluation of the PLTF for different contact lens modalities, including mini-scleral, rigid gas permeable (RGP) and soft contact lenses. This imaging technique provides an extension of the instrument’s current functionality. The potential advantages and limitations of the technique are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research explores how the concept of learner autonomy is understood and used in Vietnamese higher educational settings. Data were collected through interviews in Vietnamese with four university lecturers in Hanoi, Vietnam and then reported in an English language thesis. The problems confronted by the lecturers were in understanding the concept of learner autonomy, the complexities of translation equivalence for the concept from one language to another, and the impact of culture in interpreting the concept of learner autonomy. The paper concludes with recommendations for educators to be sensitive to cultural and linguistic considerations when transferring concepts from one culture to another.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The aim was to assess the compatibility of different multipurpose solutions (MPSs) with one type of silicone hydrogel (SiH) contact lens by, assessing the changes in both ultraviolet (UV) and visible light transmissibility of the hydrogel lens caused by the MPSs. Methods The light transmittance from 200-700 nm were measured for the lotrafilcon B blister pack solution (BPS), six MPSs namely, ReNuMultiPlus Multi-Purpose Solution (Bausch and Lomb Inc., Rochester NY, USA.); Complete RevitaLens Multi-Purpose (Abbott Medical Optics Inc., Quarryvale Co. Dublin, Ireland); All In One Light (Sauflon Pharmaceuticals Ltd., Twickenham, England); SOLO-care AQUA™ (Ciba Vision Corporation Duluth, Georgia, USA.); Biomedics All-in-one solution (CooperVision, Hamble, UK); and HippiaMultiPlus All-in-one solution (Interojo Inc., Kyeonggi-do, Korea), and a lotrafilcon B SiH lens (before and after storage), using a spectrophotometer. Results The UV transmitted through the BPS and the MPS were similar (p >.05, for all), except for the HippiaMultiPlus which was lower (p < 0.001) by 19.8%. Mean transparency values were statistically (p<.001) significantly different between the BPS and the MPSs. All MP solution/SiH lens combinations resulted in relatively high UV transmittance values especially in the UVC spectrum, and significantly increased (p <.001) the visible light transmittance values of the SiH lens. Greater changes in transparency were observed in the ReNu/SiH lens (28.5%) and the Complete RevitaLens/SiH lens (24.9%) combinations. Conclusion The six MPSs showed significant variations in the transmitted UV and visible light. Similar to the BPS, all MPSs were equally transparent, but showed very poor UVA & UVB attenuation, except for the Hippia MultiPlus. The MPS/SiH lens combinations did not significantly affect the lens transparency but it significant increased the lens transmittance of UV radiation, after storage. Further in-vivo studies are needed to validate if this effect is constant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The SBS/Blackfella Films production First Contact – that takes six non-Indigenous people and immerses them into Aboriginal Australia for the first time – captured the nation’s attention this week amassing a television audience nearing 1 million viewers, while the program’s Twitter hashtag #FirstContactSBS trended worldwide. Over the three episodes, we saw the participants get their “first contact” with Aboriginal Australia as they were welcomed into the homes of Aboriginal people in the city and in the bush...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Universal postnatal contact services are provided in several Australian states, but their impact on women’s postnatal care experience has not been evaluated. Furthermore, there is lack of evidence or consensus about the optimal type and amount of postpartum care after hospital discharge for maternal outcomes. This study aimed to assess the impact of providing Universal Postnatal Contact Service (UPNCS) funding to public birthing facilities in Queensland, Australia on women’s postnatal care experiences, and associations between amount and type (telephone or home visits) of contact on parenting confidence, and perceived sufficiency and quality of postnatal care. Methods Data collected via retrospective survey of postnatal women (N = 3,724) were used to compare women who birthed in UPNCS-funded and non-UPNCS-funded facilities on parenting confidence, sufficiency of postnatal care, and perceived quality of postnatal care. Associations between receiving telephone and home visits and the same outcomes, regardless of UPNCS funding, were also assessed. Results Women who birthed in an UPNCS-funded facility were more likely to receive postnatal contact, but UPNCS funding was not associated with parenting confidence, or perceived sufficiency or perceived quality of care. Telephone contact was not associated with parenting confidence but had a positive dose–response association with perceived sufficiency and quality. Home visits were negatively associated with parenting confidence when 3 or more were received, had a positive dose–response association with perceived sufficiency and were positively associated with perceived quality when at least 6 were received. Conclusions Funding for UPNCS is unlikely to improve population levels of maternal parenting confidence, perceived sufficiency or quality of postpartum care. Where only minimal contact can be provided, telephone may be more effective than home visits for improving women’s perceived sufficiency and quality of care. Additional service initiatives may be needed to improve women’s parenting confidence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We thank Dr Shedden and Dr Pall for their insightful comments and the opportunity to clarify a number of points from our work.1 The “protection factor” (PF) expressed as the inverse of the transmittance of contact lens (CL) material (1/Tλ), where T is the percentage transmittance of ultraviolet radiation (UVR) in a given waveband (UVC, UVB or UVA) of the UV spectrum for contact lenses is the standard method for reporting PF values and as such there should not be any controversy. We have calculated the PF for each wavelength across the entire UV spectrum (UVC, UVB, UVA) as presented in figure 3 of our previous publication.1 In that article, we were simply stating the observation when transmission in the UVC spectra band is considered especially because appreciable amounts of potentially carcinogenic short UV wavelengths was shown to be present in sunlight in our region three decades ago2 and these short wavelength photons are reported to be more biologically damaging to ocular tissues.3 In addition, the depletion of the Ozone layer is still continuing. Nevertheless, we understand the concern of the authors that the results of the PF might be confusing to those who are not familiar with the science of UVR and as such we have made some revisions to the findings of the calculated PF...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To evaluate the influence of cone location and corneal cylinder on RGP corrected visual acuities and residual astigmatism in patients with keratoconus. Methods In this prospective study, 156 eyes from 134 patients were enrolled. Complete ophthalmologic examination including manifest refraction, Best spectacle visual acuity (BSCVA), slit-lamp biomicroscopy was performed and corneal topography analysis was done. According to the cone location on the topographic map, the patients were divided into central and paracentral cone groups. Trial RGP lenses were selected based on the flat Sim K readings and a ‘three-point touch’ fitting approach was used. Over contact lens refraction was performed, residual astigmatism (RA) was measured and best-corrected RGP visual acuities (RGPVA) were recorded. Results The mean age (±SD) was 22.1 ± 5.3 years. 76 eyes (48.6%) had central and 80 eyes (51.4%) had paracentral cone. Prior to RGP lenses fitting mean (±SD) subjective refraction spherical equivalent (SRSE), subjective refraction astigmatism (SRAST) and BSCVA (logMAR) were −5.04 ± 2.27 D, −3.51 ± 1.68 D and 0.34 ± 0.14, respectively. There were statistically significant differences between central and paracentral cone groups in mean values of SRSE, SRAST, flat meridian (Sim K1), steep meridian (Sim K2), mean K and corneal cylinder (p-values < 0.05). Comparison of BSCVA to RGPVA shows that vision has improved 0.3 logMAR by RGP lenses (p < 0.0001). Mean (±SD) RA was −0.72 ± 0.39 D. There were no statistically significant differences between RGPVAs and RAs of central and paracentral cone groups (p = 0.22) and (p = 0.42), respectively. Pearson's correlation analysis shows that there is a statistically significant relationship between corneal cylinder and BSCVA and RGPVA, However, the relationship between corneal cylinder and residual astigmatism was not significant. Conclusions Cone location has no effect on the RGP corrected visual acuities and residual astigmatism in patients with keratoconus. Corneal cylinder and Sim K values influence RGP-corrected visual acuities but do not influence residual astigmatism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the development of nanoporous tungsten trioxide (WO3) Schottky diode-based gas sensors. Nanoporous WO3 films were prepared by anodic oxidation of tungsten foil in ethylene glycol mixed with ammonium fluoride and a small amount of water. Anodization resulted in highly ordered WO3 films with a large surface-to-volume ratio. Utilizing these nanoporous structures, Schottky diode-based gas sensors were developed by depositing a platinum (Pt) catalytic contact and tested towards hydrogen gas and ethanol vapour. Analysis of the current–voltage characteristics and dynamic responses of the sensors indicated that these devices exhibited a larger voltage shift in the presence of hydrogen gas compared to ethanol vapour at an optimum operating temperature of 200 °C. The gas sensing mechanism was discussed, associating the response to the intercalating H+ species that are generated as a result of hydrogen and ethanol molecule breakdowns onto the Pt/WO3 contact and their spill over into nanoporous WO3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rail joints are provided with a gap to account for thermal movement and to maintain electrical insulation for the control of signals and/or broken rail detection circuits. The gap in the rail joint is regarded as a source of significant problems for the rail industry since it leads to a very short rail service life compared with other track components due to the various, and difficult to predict, failure modes – thus increasing the risk for train operations. Many attempts to improve the life of rail joints have led to a large number of patents around the world; notable attempts include strengthening through larger-sized joint bars, an increased number of bolts and the use of high yield materials. Unfortunately, no design to date has shown the ability to prolong the life of the rail joints to values close to those for continuously welded rail (CWR). This paper reports the results of a fundamental study that has revealed that the wheel contact at the free edge of the railhead is a major problem since it generates a singularity in the contact pressure and railhead stresses. A design was therefore developed using an optimisation framework that prevents wheel contact at the railhead edge. Finite element modelling of the design has shown that the contact pressure and railhead stress singularities are eliminated, thus increasing the potential to work as effectively as a CWR that does not have a geometric gap. An experimental validation of the finite element results is presented through an innovative non-contact measurement of strains. Some practical issues related to grinding rails to the optimal design are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A recent hydrodynamic theory of liquid slippage on a solid substrate (Kirkinis & Davis, Phys. Rev. Lett., vol. 110, 2013, 234503) gives rise to a sequence of eddies (Moffatt vortices) that co-move with a moving contact line (CL) in a liquid wedge. The presence of these vortices is established through secular equations that depend on the dynamic contact angle α and capillary number Ca. The limiting case α→O is associated with the appearance of such vortices in a channel. The vortices are generated by the relative motion of the interfaces, which in turn is due to the motion of the CL. This effect has yet to be observed in experiment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, media 'scandals' have pervaded a number of Australian body contact sports, in particular rugby league, rugby union and Australian rules football. Utilising the theoretical framework of masculinities, this research interviews footballers to gauge their perceptions of this media attention and how it compares to their own perspectives regarding off-field violence. Drawing inspiration from James Messerschmidt's (2000) 'Nine Lives' study and R.W. Connell's (1995) theoretical masculinities framework, in-depth, semi-structured interviews—known as life histories—were conducted with 12 footballers. Twelve life histories were completed with four men from each of the three major Australian football codes, namely Australian rules football, rugby union and rugby league. The research explores linkages between masculinity, body contact sport and engagement (or lack thereof) in violence 'off field'.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. Methods The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00D and +6.00D. Measurements were taken over each contact lens and also before and after the CLs had been worn. Results The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p<0.001) but no significant difference was found between the two powers of CLs. Conclusions Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result didn’t change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

- Purpose To examine the change in corneal thickness and posterior curvature following 8 hours of miniscleral contact lens wear. - Methods Scheimpflug imaging (Pentacam HR, Oculus) was captured before, and immediately following, 8 hours of miniscleral contact lens wear for 15 young (mean age 22 ± 3 years), healthy participants with normal corneae. Natural diurnal variations were considered by measuring baseline corneal changes obtained on a separate control day without contact lens wear. - Results Over the central 6 mm of the cornea, a small, but highly statistically significant amount of edema was observed following 8 hours of miniscleral lens wear, after accounting for normal diurnal fluctuations (mean ± standard deviation percentage swelling 1.70 ± 0.98%, p < 0.0001). Posterior corneal topography remained stable following lens wear (-0.01 ± 0.07 mm steepening over the central 6 mm, p = 0.60). The magnitude of posterior corneal topographical changes following lens wear did not correlate with the extent of lens-related corneal edema (r = -0.16, p = 0.57). Similarly, the initial central corneal vault (maximum post-lens tear layer depth) was not associated with corneal swelling following lens removal (r = 0.27, p = 0.33). - Conclusions While a small amount of corneal swelling was induced following 8 hours of miniscleral lens wear (on average <2%), modern high Dk miniscleral contact lenses that vault the cornea do not induce clinically significant corneal edema or hypoxic related posterior corneal curvature changes during short-term wear. Longer-term studies of compromised eyes (e.g. corneal ectasia) are still required to inform the optimum lens and fitting characteristics for safe scleral lens wear to minimize corneal hypoxia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the late 1990s, the International Contact Lens Prescribing Survey Consortium has prospectively gathered information about 285,000 contact lens fits from more than 50 countries. This article presents our 14th annual summary of current trends published in Contact Lens Spectrum. With only minor differences in the distribution of our surveys among markets, we have continued to adopt the same approach throughout the past 18 years. Through national coordinators, we approach contact lens prescribers in each country and ask them to record information about the first 10 patients whom they fit with contact lenses after receipt of our survey form. The information collected is generic, and respondents are weighted to reflect the volume of contact lens fits undertaken by each. For this 2014 report, we present information about 25,179 contact lens fits from 32 countries...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To eye care practitioners, citation metrics may seem to be a somewhat esoteric and irrelevant concept, far removed from the realities or real world, day-to-day clinical practice. However, quantitative analysis of the published literature is becoming increasingly important, and a beautiful example of this is presented in this issue of the Journal of Optometry. My former PhD student, Genís Cardona, has teamed up with Joan Sanz to undertake a thorough and telling analysis of current worldwide publishing trends in the contact lens field. When held in the mirror, this work reflects the growing contributions from Spanish researchers to the field...