157 resultados para units samples


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A combined data matrix consisting of high performance liquid chromatography–diode array detector (HPLC–DAD) and inductively coupled plasma-mass spectrometry (ICP-MS) measurements of samples from the plant roots of the Cortex moutan (CM), produced much better classification and prediction results in comparison with those obtained from either of the individual data sets. The HPLC peaks (organic components) of the CM samples, and the ICP-MS measurements (trace metal elements) were investigated with the use of principal component analysis (PCA) and the linear discriminant analysis (LDA) methods of data analysis; essentially, qualitative results suggested that discrimination of the CM samples from three different provinces was possible with the combined matrix producing best results. Another three methods, K-nearest neighbor (KNN), back-propagation artificial neural network (BP-ANN) and least squares support vector machines (LS-SVM) were applied for the classification and prediction of the samples. Again, the combined data matrix analyzed by the KNN method produced best results (100% correct; prediction set data). Additionally, multiple linear regression (MLR) was utilized to explore any relationship between the organic constituents and the metal elements of the CM samples; the extracted linear regression equations showed that the essential metals as well as some metallic pollutants were related to the organic compounds on the basis of their concentrations

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel, highly selective resonance light scattering (RLS) method was researched and developed for the analysis of phenol in different types of industrial water. An important aspect of the method involved the use of graphene quantum dots (GQDs), which were initially obtained from the pyrolysis of citric acid dissolved in aqueous solutions. The GQDs in the presence of horseradish peroxidase (HRP) and H2O2 were found to react quantitatively with phenol such that the RLS spectral band (310 nm) was quantitatively enhanced as a consequence of the interaction between the GQDs and the quinone formed in the above reaction. It was demonstrated that the novel analytical method had better selectivity and sensitivity for the determination of phenol in water as compared to other analytical methods found in the literature. Thus, trace amounts of phenol were detected over the linear ranges of 6.00×10−8–2.16×10−6 M and 2.40×10−6–2.88×10−5 M with a detection limit of 2.20×10−8 M. In addition, three different spiked waste water samples and two untreated lake water samples were analysed for phenol. Satisfactory results were obtained with the use of the novel, sensitive and rapid RLS method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statistical comparison of oil samples is an integral part of oil spill identification, which deals with the process of linking an oil spill with its source of origin. In current practice, a frequentist hypothesis test is often used to evaluate evidence in support of a match between a spill and a source sample. As frequentist tests are only able to evaluate evidence against a hypothesis but not in support of it, we argue that this leads to unsound statistical reasoning. Moreover, currently only verbal conclusions on a very coarse scale can be made about the match between two samples, whereas a finer quantitative assessment would often be preferred. To address these issues, we propose a Bayesian predictive approach for evaluating the similarity between the chemical compositions of two oil samples. We derive the underlying statistical model from some basic assumptions on modeling assays in analytical chemistry, and to further facilitate and improve numerical evaluations, we develop analytical expressions for the key elements of Bayesian inference for this model. The approach is illustrated with both simulated and real data and is shown to have appealing properties in comparison with both standard frequentist and Bayesian approaches

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel near-infrared spectroscopy (NIRS) method has been researched and developed for the simultaneous analyses of the chemical components and associated properties of mint (Mentha haplocalyx Briq.) tea samples. The common analytes were: total polysaccharide content, total flavonoid content, total phenolic content, and total antioxidant activity. To resolve the NIRS data matrix for such analyses, least squares support vector machines was found to be the best chemometrics method for prediction, although it was closely followed by the radial basis function/partial least squares model. Interestingly, the commonly used partial least squares was unsatisfactory in this case. Additionally, principal component analysis and hierarchical cluster analysis were able to distinguish the mint samples according to their four geographical provinces of origin, and this was further facilitated with the use of the chemometrics classification methods-K-nearest neighbors, linear discriminant analysis, and partial least squares discriminant analysis. In general, given the potential savings with sampling and analysis time as well as with the costs of special analytical reagents required for the standard individual methods, NIRS offered a very attractive alternative for the simultaneous analysis of mint samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple one-step electrodeposition method was used to construct a glassy carbon electrode (GCE), which has been modified with Cu doped gold nanoparticles (GNPs), i.e. a Cu@AuNPs/GCE. This electrode was characterized with the use of scanning electron microscopy (SEM) and X-ray diffraction (XRD) techniques. The eugenol was electrocatalytically oxidized at the Cu@AuNPs/GCE. At this electrode, in comparison with the behavior at the GCE alone, the corresponding oxidation peak current was enhanced and the shift of the oxidation potentials to lower values was observed. Electrochemical behavior of eugenol at the Cu@AuNPs/GCE was investigated with the use of the cyclic voltammetry (CV) technique, and additionally, in order to confirm the electrochemical reaction mechanism for o-methoxy phenols, CVs for catechol, guaiacol and vanillin were investigated consecutively. Based on this work, an electrochemical reaction mechanism for o-methoxy phenols was suggested, and in addition, the above Cu@AuNPs/GCE was successfully employed for the analysis of eugenol in food samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An important uncertainty when estimating per capita consumption of, for example, illicit drugs by means of wastewater analysis (sometimes referred to as “sewage epidemiology”) relates to the size and variability of the de facto population in the catchment of interest. In the absence of a day-specific direct population count any indirect surrogate model to estimate population size lacks a standard to assess associated uncertainties. Therefore, the objective of this study was to collect wastewater samples at a unique opportunity, that is, on a census day, as a basis for a model to estimate the number of people contributing to a given wastewater sample. Mass loads for a wide range of pharmaceuticals and personal care products were quantified in influents of ten sewage treatment plants (STP) serving populations ranging from approximately 3500 to 500 000 people. Separate linear models for population size were estimated with the mass loads of the different chemical as the explanatory variable: 14 chemicals showed good, linear relationships, with highest correlations for acesulfame and gabapentin. De facto population was then estimated through Bayesian inference, by updating the population size provided by STP staff (prior knowledge) with measured chemical mass loads. Cross validation showed that large populations can be estimated fairly accurately with a few chemical mass loads quantified from 24-h composite samples. In contrast, the prior knowledge for small population sizes cannot be improved substantially despite the information of multiple chemical mass loads. In the future, observations other than chemical mass loads may improve this deficit, since Bayesian inference allows including any kind of information relating to population size.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Giant Cell Arteritis (GCA) is the most common vasculitis affecting the elderly. Archived formalin-fixed paraffin-embedded (FFPE) temporal artery biopsy (TAB) specimens potentially represent a valuable resource for large-scale genetic analysis of this disease. FFPE TAB samples were obtained from 12 patients with GCA. Extracted TAB DNA was assessed by real time PCR before restoration using the Illumina HD FFPE Restore Kit. Paired FFPE-blood samples were genotyped on the Illumina OmniExpress FFPE microarray. The FFPE samples that passed stringent quality control measures had a mean genotyping success of >97%. When compared with their matching peripheral blood DNA, the mean discordant heterozygote and homozygote single nucleotide polymorphisms calls were 0.0028 and 0.0003, respectively, which is within the accepted tolerance of reproducibility. This work demonstrates that it is possible to successfully obtain high-quality microarray-based genotypes FFPE TAB samples and that this data is similar to that obtained from peripheral blood.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most genome-wide association studies to date have been performed in populations of European descent, but there is increasing interest in expanding these studies to other populations. The performance of genotyping chips in Asian populations is not well established. Therefore, we sought to test the performance of widely used fixed-marker, genome-wide association studies chips in the Han Chinese population. Non-HapMap Chinese samples (n = 396) were genotyped using the Illumina OmniExpress and Affymetrix 6.0 platforms, whereas a subset also were genotyped using the Immunochip. Genotyped markers from the Affymetrix 6.0 and Illumina OmniExpress were used for full genome imputation based on the HapMap 2 JPT+CHB (Japanese from Tokyo, Japan and Chinese from Beijing, China) reference panel. The concordance between markers genotypes for the three platforms was very high whether directly genotyped or genotyped and imputed single nucleotide polymorphisms (SNPs; .99.8% for directly genotyped and .99.5% for genotyped and imputed SNPs, respectively) were compared. The OmniExpress chip data enabled more SNPs to be imputed, particularly SNPs with minor allele frequency .5%. The OmniExpress chip achieved better coverage of HapMap SNPs than the Affymetrix 6.0 chip (73.6% vs. 65.9%, respectively, for minor allele frequency .5%). The Affymetrix 6.0 and Illumina OmniExpress chip have similar genotyping accuracy and provide similar accuracy of imputed SNPs. The OmniExpress chip however provides better coverage of Asian HapMap SNPs, although its coverage of HapMap SNPs is moderate. © 2013 Jiang et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper considers the one-sample sign test for data obtained from general ranked set sampling when the number of observations for each rank are not necessarily the same, and proposes a weighted sign test because observations with different ranks are not identically distributed. The optimal weight for each observation is distribution free and only depends on its associated rank. It is shown analytically that (1) the weighted version always improves the Pitman efficiency for all distributions; and (2) the optimal design is to select the median from each ranked set.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traditional comparisons between the capture efficiency of sampling devices have generally looked at the absolute differences between devices. We recommend that the signal-to-noise ratio be used when comparing the capture efficiency of benthic sampling devices. Using the signal-to-noise ratio rather than the absolute difference has the advantages that the variance is taken into account when determining how important the difference is, the hypothesis and minimum detectable difference can be made identical for all taxa, it is independent of the units used for measurement, and the sample-size calculation is independent of the variance. This new technique is illustrated by comparing the capture efficiency of a 0.05 m(2) van Veen grab and an airlift suction device, using samples taken from Heron and One Tree lagoons, Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Small-angle neutron scattering (SANS) and ultra-small angle neutron scattering (USANS) with contrast matching techniques (Melnichenko and others, 2012) were used to investigate size distribution and gas accessibility in pores in an approximately 10.6 cm long Mississippian Barnett Shale butt core from the Fort Worth Basin, Texas, USA. SANS and USANS measurements record scattering from all pores, both open and closed, in the size range 10nm - ~10 μ. The techniques can also be used to determine the material that contains pores and the number of pores as a function of size. By injecting deuterated methane gas (CD4) at contrast matching pressure it is possible to distinguish which pores are accessible, or open, to fluids and which ones are not.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerous studies have reported association between variants in the dystrobrevin binding protein 1 (dysbindin) gene (DTNBP1) and schizophrenia. However, the pattern of results is complex and to date, no specific risk marker or haplotype has been consistently identified. The number of single nucleotide polymorphisms (SNPs) tested in these studies has ranged from 5 to 20. We attempted to replicate previous findings by testing 16 SNPs in samples of 41 Australian pedigrees, 194 Australian cases and 180 controls, and 197 Indian pedigrees. No globally significant evidence for association was observed in any sample, despite power calculations indicating sufficient power to replicate several previous findings. Possible explanations for our results include sample differences in background linkage disequilibrium and/or risk allele effect size, the presence of multiple risk alleles upon different haplotypes, or the presence of a single risk allele upon multiple haplotypes. Some previous associations may also represent false positives. Examination of Caucasian HapMap phase II genotype data spanning the DTNBP1 region indicates upwards of 40 SNPs are required to satisfactorily assess all nonredundant variation within DTNBP1 and its potential regulatory regions for association with schizophrenia. More comprehensive studies in multiple samples will be required to determine whether specific DTNBP1 variants function as risk factors for schizophrenia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integrated exposure to polycyclic aromatic hydrocarbons (PAHs) can be assessed through monitoring of urinary mono-hydroxylated PAHs (OH-PAHs). The aim of this study was to provide the first assessment of exposure to PAHs in a large sample of the population in Queensland, Australia including exposure to infant (0-4. years). De-identified urine specimens, obtained from a pathology laboratory, were stratified by age and sex, and pooled (n. =. 24 pools of 100) and OH-PAHs were measured by gas chromatography-isotope dilution-tandem mass spectrometry. Geometric mean (GM) concentrations ranged from 30. ng/L (4-hydroxyphenanthrene) to 9221. ng/L (1-naphthol). GM of 1-hydroxypyrene, the most commonly used PAH exposure biomarker, was 142. ng/L. The concentrations of OH-PAHs found in this study are consistent with those in developed countries and lower than those in developing countries. We observed no association between sex and OH-PAH concentrations. However, we observed lower urinary concentrations of all OH-PAHs in samples from infants (0-4. years), children (5-14. years) and the elderly (>. 60. year old) compared with samples from other age groups (15-29, 30-44 and 45-59. years) which may be attributed to age-dependent behaviour-specific exposure sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Parabens, benzophenone-3 and triclosan are common ingredients used as preservatives, ultraviolet radiation filters and antimicrobial agents, respectively. Human exposure occurs through consumption of processed food and use of cosmetics and consumer products. The aim of this study was to provide a preliminary characterisation of exposure to selected personal care product chemicals in the general Australian population. De-identified urine specimens stratified by age and sex were obtained from a community-based pathology laboratory and pooled (n= 24 pools of 100). Concentrations of free and total (sum of free plus conjugated) species of methyl, ethyl, propyl and butyl paraben, benzophenone-3 and triclosan were quantified using isotope dilution tandem mass spectrometry; with geometric means 232, 33.5, 60.6, 4.32, 61.5 and 87.7. ng/mL, respectively. Age was inversely associated with paraben concentration, and females had concentrations approximately two times higher than males. Total paraben and benzophenone-3 concentrations are significantly higher than reported worldwide, and the average triclosan concentration was more than one order of magnitude higher than in many other populations. This study provides the first data on exposure of the general Australian population to a range of common personal care product chemical ingredients, which appears to be prevalent and warrants further investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assessing blood concentration of persistent organic pollutants (POPs) in infants is difficult due to the ethical and practical difficulties in obtaining sufficient quantities of blood. To determine whether measuring POPs in faeces might reflect blood concentration during infancy, we measured the concentrations of a range of POPs (i.e. polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) and organochlorine pesticides (OCPs)) in a pilot study using matched breast milk and infant faecal samples obtained from ten mother-child pairs. All infants were breast fed, with 8 of them also receiving solid food at the time of faecal sampling. In this small dataset faecal concentrations (range 0.01-41ngg-1 lipid) are strongly associated with milk concentrations (range 0.02-230ngg-1 lipid). Associations with other factors generally could not be detected in this dataset, with the exception of a small effect of age or growth. Different sources (external or internal) of exposure appeared to directly influence faecal concentrations of different chemicals based on different inter-individual variability in the faeces-to-milk concentration ratio Rfm. Overall, the matrix of faeces as an external measure of internal exposure in infants looks promising for some chemicals and is worth assessing further in larger datasets.