290 resultados para sensible heat loss
Resumo:
In this paper, a new comprehensive planning methodology is proposed for implementing distribution network reinforcement. The load growth, voltage profile, distribution line loss, and reliability are considered in this procedure. A time-segmentation technique is employed to reduce the computational load. Options considered range from supporting the load growth using the traditional approach of upgrading the conventional equipment in the distribution network, through to the use of dispatchable distributed generators (DDG). The objective function is composed of the construction cost, loss cost and reliability cost. As constraints, the bus voltages and the feeder currents should be maintained within the standard level. The DDG output power should not be less than a ratio of its rated power because of efficiency. A hybrid optimization method, called modified discrete particle swarm optimization, is employed to solve this nonlinear and discrete optimization problem. A comparison is performed between the optimized solution based on planning of capacitors along with tap-changing transformer and line upgrading and when DDGs are included in the optimization.
Resumo:
A study of the bulk formation of YBa2Cu3O7-x from the Y2BaCuO5 plus liquid regime reveals that phase formation occurs at appreciable rates below 950°C in air. This result has been observed for phase-pure YBa2Cu3O7-x starting material given two types of heat treatment: held at 1100°C and slow-cooled from 1030°C at 6°C/h or heat-treated isothermally. Differential thermal analysis, with a cooling rate of 10°C/min indicates that the degree of undercooling for the peritectic formation of YBa2Cu3O7-x is greater than 100°C. © 1994.
Resumo:
Preliminary data is presented on a detailed statistical analysis of k-factor determination for a single class of minerals (amphiboles) which contain a wide range of element concentrations. These amphiboles are homogeneous, contain few (if any) subsolidus microstructures and can be readily prepared for thin film analysis. In previous studies, element loss during the period of irradiation has been assumed negligible for the determination of k-factors. Since this phenomena may be significant for certain mineral systems, we also report on the effect of temperature on k-factor determination for various elements using small probe sizes (approx.20 nm).
Resumo:
Concepts used in this chapter include: Thermoregulation:- Thermoregulation refers to the body’s sophisticated, multi-system regulation of core body temperature. This hierarchical system extends from highly thermo-sensitive neurons in the preoptic region of the brain proximate to the rostral hypothalamus, down to the brain stem and spinal cord. Coupled with receptors in the skin and spine, both central and peripheral information on body temperature is integrated to inform and activate the homeostatic mechanisms which maintain our core temperature at 37oC1. Hyperthermia:- An imbalance between the metabolic and external heat accumulated in the body and the loss of heat from the body2. Exertional heat stroke:- A disorder of excessive heat production coupled with insufficient heat dissipation which occurs in un-acclimated individuals who are engaging in over-exertion in hot and humid conditions. This phenomenon includes central nervous system dysfunction and critical dysfunction to all organ systems including renal, cardiovascular, musculoskeletal and hepatic functions. Non-exertional heat stroke:- In contrast to exertional heatstroke as a consequence of high heat production during strenuous exercise, non-exertional heatstroke results from prolonged exposure to high ambient temperature. The elderly, those with chronic health conditions and children are particularly susceptible.3 Rhabdomylosis:- An acute, sometimes fatal disease characterised by destruction of skeletal muscle. In exertional heat stroke, rhabdomylosis occurs in the context of strenuous exercise when mechanical and/or metabolic stress damages the skeletal muscle, causing elevated serum creatine kinease. Associated with this is the potential development of hyperkalemia, myoglobinuria and renal failure. Malignant hyperthermia:- Malignant hyperthermia is “an inherited subclinical myopathy characterised by a hypermetabolic reaction during anaesthesia. The reaction is related to skeletal muscle calcium dysregulation triggered by volatile inhaled anaesthetics and/or succinylcholine.”4 Presentation includes skeletal muscle rigidity, mixed metabolic and respiratory acidosis, tachycardia, hyperpyrexia, rhabdomylosis, hyperkalaemia, elevated serum creatine kinease, multi-organ failure, disseminated intravascular coagulation and death.5
Resumo:
Cold water immersion (CWI) is a popular recovery modality, but actual physiological responses to CWI after exercise in the heat have not been well documented. The purpose of this study was to examine effects of 20-min CWI (14 degrees C) on neuromuscular function, rectal (T(re)) and skin temperature (T(sk)), and femoral venous diameter after exercise in the heat. Ten well-trained male cyclists completed two bouts of exercise consisting of 90-min cycling at a constant power output (216+/-12W) followed by a 16.1km time trial (TT) in the heat (32 degrees C). Twenty-five minutes post-TT, participants were assigned to either CWI or control (CON) recovery conditions in a counterbalanced order. T(re) and T(sk) were recorded continuously, and maximal voluntary isometric contraction torque of the knee extensors (MVIC), MVIC with superimposed electrical stimulation (SMVIC), and femoral venous diameters were measured prior to exercise, 0, 45, and 90min post-TT. T(re) was significantly lower in CWI beginning 50min post-TT compared with CON, and T(sk) was significantly lower in CWI beginning 25min post-TT compared with CON. Decreases in MVIC, and SMVIC torque after the TT were significantly greater for CWI compared with CON; differences persisted 90min post-TT. Femoral vein diameter was approximately 9% smaller for CWI compared with CON at 45min post-TT. These results suggest that CWI decreases T(re), but has a negative effect on neuromuscular function.
Resumo:
This study examined the effects of post-exercise cooling on recovery of neuromuscular, physiological, and cerebral hemodynamic responses after intermittent-sprint exercise in the heat. Nine participants underwent three post-exercise recovery trials, including a control (CONT), mixed-method cooling (MIX), and cold-water immersion (10 °C; CWI). Voluntary force and activation were assessed simultaneously with cerebral oxygenation (near-infrared spectroscopy) pre- and post-exercise, post-intervention, and 1-h and 24-h post-exercise. Measures of heart rate, core temperature, skin temperature, muscle damage, and inflammation were also collected. Both cooling interventions reduced heart rate, core, and skin temperature post-intervention (P < 0.05). CWI hastened the recovery of voluntary force by 12.7 ± 11.7% (mean ± SD) and 16.3 ± 10.5% 1-h post-exercise compared to MIX and CONT, respectively (P < 0.01). Voluntary force remained elevated by 16.1 ± 20.5% 24-h post-exercise after CWI compared to CONT (P < 0.05). Central activation was increased post-intervention and 1-h post-exercise with CWI compared to CONT (P < 0.05), without differences between conditions 24-h post-exercise (P > 0.05). CWI reduced cerebral oxygenation compared to MIX and CONT post-intervention (P < 0.01). Furthermore, cooling interventions reduced cortisol 1-h post-exercise (P < 0.01), although only CWI blunted creatine kinase 24-h post-exercise compared to CONT (P < 0.05). Accordingly, improvements in neuromuscular recovery after post-exercise cooling appear to be disassociated with cerebral oxygenation, rather reflecting reductions in thermoregulatory demands to sustain force production.
Resumo:
High heat-producing granites (HHPGs) are reservoir rocks for enhanced geothermal systems (EGS), yet the origins of their anomalous chemistry remain poorly understood. To gain a better understanding of the characteristic distribution of elemental depletions and enrichments (focussing on U, Th & K) within granite suites of different heritage and tectonic setting, and the processes that lead to these enrichments, we are undertaking a systematic accessory-mineral chronochemical study of two suites of S- and I-type granites in northern Queensland, as well as two archetypal HHPGs in Cornwall, England (S-type) and Soultz-sous- Forêts, France (I-type). Novel zircon LA-ICP-MS chronochemical methods will later be underpinned by a systematic petrographic, scanning electron microscope (SEM), and electron microprobe (EPMA) study of all the REE-Y-Th-U-rich accessory minerals to fully characterise how the composition, textural distributions and associations change with rock chemistry between and among the suites. Preliminary results indicate that zircons with inherited ages do not have anomalously high U (>1000 ppm) & Th (>400 ppm) values (Ahrens, 1965). Instead, enrichment in these HPE is seen in zircons dated to around the time of magmatic emplacement. These results indicate that enrichment arose primarily through fractional crystallisation of the granitic magmas. Our results support the suggestion that a source pre-enriched in the HPEs does not appear to be fundamental for the formation of all HHPGs. Instead fractional crystallisation processes, and the accessory minerals formed in magmas of differing initial compositions, are the key controls on the levels of enrichment observed (e.g. Champion & Chappell, 1992; Chappell & Hine, 2006). One implication is that the most fractionated granites may not be the most enriched in the HPEs and therefore prospective to future EGS development.
Resumo:
Objectives To review the existing research on the effectiveness of heat warning systems (HWSs) in saving lives and reducing harm. Methods A systematic search of major databases was conducted, using “heat, heatwave, high temperature, hot temperature, OR hot climate” AND “warning system”. Results Fifteen articles were retrieved. Six studies asserted that fewer people died of excessive heat after HWS implementation. HWS was associated with reduction in ambulance use. One study estimated the benefits of HWS to be 468millionforsaving117livescomparedto210,000 costs of running the system. Eight studies showed that mere availability of HWS did not lead to behavioral changes. Perceived threat of heat dangers to self/others was the main factor related to heeding warnings and taking proper actions. However, costs and barriers associated with taking protective actions, such as costs of running air conditioners, were of significant concern particularly to the poor. Conclusions Research in this area is limited. Prospective designs applying health behavior theories should establish whether HWS can produce the health benefits they are purported to achieve by identifying the target vulnerable groups.
Resumo:
Heatwaves are associated with significant health risks particularly among vulnerable groups. To minimize these risks, heat warning systems have been implemented. The question therefore is how effective these systems are in saving lives and reducing heat-related harm. We systematically searched and reviewed 15 studies which examined this. Six studies asserted that fewer people died of excessive heat after the implementation of heat warning systems. Demand for ambulance decreased following the implementation of these systems. One study also estimated the costs of running heat warning systems at US$210,000 compared to the US$468 million benefits of saving 117 lives. The remaining eight studies investigated people?s response to heat warning systems and taking appropriate actions against heat harms. Perceived threat of heat dangers emerged as the main factor related to heeding the warnings and taking proper actions. However, barriers, such as costs of running air-conditioners, were of significant concern, particularly to the poor. The weight of the evidence suggests that heat warning systems are effective in reducing mortality and, potentially, morbidity. However, their effectiveness may be mediated by cognitive, emotive and socio-demographic characteristics. More research is urgently required into the cost-effectiveness of heat warning systems? measures and improving the utilization of the services.
Resumo:
Fire safety design is important to eliminate the loss of property and lives during fire events. Gypsum plasterboard is widely used as a fire safety material in the building industry all over the world. It contains gypsum (CaSO4.2H2O) and Calcium Carbonate (CaCO3) and most importantly free and chemically bound water in its crystal structure. The dehydration of the gypsum and the decomposition of Calcium Carbonate absorb heat, which gives the gypsum plasterboard fire resistant qualities. Currently plasterboard manufacturers use additives such as vermiculite to overcome shrinkage of gypsum core and glass fibre to bridge shrinkage cracks and enhance the integrity of board during calcination and after the loss of paper facings in fires. Past research has also attempted to reduce the thermal conductivity of plasterboards using fillers. However, no research has been undertaken to enhance the specific heat of plasterboard and the points of dehydration using chemical additives and fillers. Hence detailed experimental studies of powdered samples of plasterboard mixed with chemical additives and fillers in varying proportions were conducted. These tests showed the enhancement of specific heat of plasterboard. Numerical models were also developed to investigate the thermal performance of enhanced plasterboards under standard fire conditions. The results showed that the use of these enhanced plasterboards in steel wall systems can significantly improve their fire performance. This paper presents the details of this research and the results that can be used to enhance the fire safety of steel wall systems commonly used in buildings.
Resumo:
A dual-scale model of the torrefaction of wood was developed and used to study industrial configurations. At the local scale, the computational code solves the coupled heat and mass transfer and the thermal degradation mechanisms of the wood components. At the global scale, the two-way coupling between the boards and the stack channels is treated as an integral component of the process. This model is used to investigate the effect of the stack configuration on the heat treatment of the boards. The simulations highlight that the exothermic reactions occurring in each single board can be accumulated along the stack. This phenomenon may result in a dramatic eterogeneity of the process and poses a serious risk of thermal runaway, which is often observed in industrial plants. The model is used to explain how thermal runaway can be lowered by increasing the airflow velocity, the sticker thickness or by gas flow reversal.
Resumo:
Background Recent evidence has linked induced abortion with later adverse psychiatric outcomes in young women. Aims To examine whether abortion or miscarriage are associated with subsequent psychiatric and substance use disorders. Method A sample (n=1223) of women from a cohort born between 1981 and 1984 in Australia were assessed at 21 years for psychiatric and substance use disorders and lifetime pregnancy histories. Results Young women reporting a pregnancy loss had nearly three times the odds of experiencing a lifetime illicit drug disorder (excluding cannabis): abortion odds ratio (OR)=3.6 (95% CI 2.0–6.7) and miscarriage OR=2.6 (95% CI 1.2–5.4). Abortion was associated with alcohol use disorder (OR=2.1, 95% CI 1.3–3.5) and 12-month depression (OR=1.9, 95% CI 1.1–3.1). Conclusions These findings add to the growing body of evidence suggesting that pregnancy loss per se, whether abortion or miscarriage, increases the risk of a range of substance use disorders and affective disorders in young women.
Resumo:
Between 8 and 20 percent of depression in young men and women aged 18-23 is associated with pregnancy loss, according to a recent analysis of the 30 year Mater Hospital longitudinal study of mothers and children. Dr Kaeleen Dingle from the University of Queensland explains the study and discusses the implications for both men and women.
Resumo:
Recent evidence has linked induced abortion with later adverse psychiatric outcomes in young women. Little is known about later adverse psychiatric outcomes in young men whose partners have fallen pregnant and either go on to have a child, have an abortion or miscarry. 1223 women and 1159 men, from an Austrailan cohort born between 1981 and 1984, were assessed at 21 years for psychiatric and substance misuse and lifetime pregnancy histories. Young women reporting a pregnancy loss (either miscarriage or abortion) had nearly three times the odds of experiencing a illicit drug disorder (excluding cannabis), and nearly twice the odds of an alcohol misuse compared to never pregnant women. Young men whose partner had an abortion, but not a miscarriage, had nearly twice the odds of cannabis disorder, illicit drug disorder, and mood disorder compared to men that had never fathered a pregnancy. Young women who have lost a pregnancy have an increased risk of developing alcohol or substance abuse in later life. Young men whose partner aborted a pregnancy only had an increased of substance abuse and mood disorder in later life. These findings add to the growing body of evidence suggesting that pregnancy loss per se increases the risk of a range of substance use disorders in young women. The findings for young men are novel and raise the possibility that the associations measured may be due to common unmeasured factors associated with early pregnancy in young people rather than pregnancy loss.
Resumo:
Climate change is leading to an increased frequency and severity of heat waves. Spells of several consecutive days of unusually high temperatures have led to increased mortality rates for the more vulnerable in the community. The problem is compounded by the escalating energy costs and increasing peak electrical demand as people become more reliant on air conditioning. Domestic air conditioning is the primary determinant of peak power demand which has been a major driver of higher electricity costs. This report presents the findings of multidisciplinary research which develops a national framework to evaluate the potential impacts of heat waves. It presents a technical, social and economic approach to adapt Australian residential buildings to ameliorate the impact of heat waves in the community and reduce the risk of its adverse outcomes. Through the development of a methodology for estimating the impact of global warming on key weather parameters in 2030 and 2050, it is possible to re-evaluate the size and anticipated energy consumption of air conditioners in future years for various climate zones in Australia. Over the coming decades it is likely that mainland Australia will require more cooling than heating. While in some parts the total electricity usage for heating and cooling may remain unchanged, there is an overall significant increase in peak electricity demand, likely to further drive electricity prices. Through monitoring groups of households in South Australia, New South Wales and Queensland, the impact of heat waves on both thermal comfort sensation and energy consumption for air conditioning has been evaluated. The results show that households are likely to be able to tolerate slightly increased temperature levels indoors during periods of high outside temperatures. The research identified that household electricity costs are likely to rise above what is currently projected due to the impact of climate change. Through a number of regulatory changes to both household design and air conditioners, this impact can be minimised. A number of proposed retrofit and design measures are provided, which can readily reduce electricity usage for cooling at minimal cost to the household. Using a number of social research instruments, it is evident that households are willing to change behaviour rather than to spend money. Those on lower income and elderly individuals are the least able to afford the use of air conditioning and should be a priority for interventions and assistance. Increasing community awareness of cost effective strategies to manage comfort and health during heat waves is a high priority recommended action. Overall, the research showed that a combined approach including behaviour change, dwelling modification and improved air conditioner selection can readily adapt Australian households to the impact of heat waves, reducing the risk of heat related deaths and household energy costs.