351 resultados para provocative cardiac testing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Despite its efficacy and cost-effectiveness, exercise-based cardiac rehabilitation is undertaken by less than one-third of clinically eligible cardiac patients in every country for which data is available. Reasons for non-participation include the unavailability of hospital-based rehabilitation programs, or excessive travel time and distance. For this reason, there have been calls for the development of more flexible alternatives. Methodology and Principal Findings We developed a system to enable walking-based cardiac rehabilitation in which the patient's single-lead ECG, heart rate, GPS-based speed and location are transmitted by a programmed smartphone to a secure server for real-time monitoring by a qualified exercise scientist. The feasibility of this approach was evaluated in 134 remotely-monitored exercise assessment and exercise sessions in cardiac patients unable to undertake hospital-based rehabilitation. Completion rates, rates of technical problems, detection of ECG changes, pre- and post-intervention six minute walk test (6 MWT), cardiac depression and Quality of Life (QOL) were key measures. The system was rated as easy and quick to use. It allowed participants to complete six weeks of exercise-based rehabilitation near their homes, worksites, or when travelling. The majority of sessions were completed without any technical problems, although periodic signal loss in areas of poor coverage was an occasional limitation. Several exercise and post-exercise ECG changes were detected. Participants showed improvements comparable to those reported for hospital-based programs, walking significantly further on the post-intervention 6 MWT, 637 m (95% CI: 565–726), than on the pre-test, 524 m (95% CI: 420–655), and reporting significantly reduced levels of cardiac depression and significantly improved physical health-related QOL. Conclusions and Significance The system provided a feasible and very flexible alternative form of supervised cardiac rehabilitation for those unable to access hospital-based programs, with the potential to address a well-recognised deficiency in health care provision in many countries. Future research should assess its longer-term efficacy, cost-effectiveness and safety in larger samples representing the spectrum of cardiac morbidity and severity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Electrical impedance tomography (EIT) has been shown to be able to distinguish both ventilation and perfusion. With adequate filtering the regional distributions of both ventilation and perfusion and their relationships could be analysed. Several methods of separation have been suggested previously, including breath holding, electrocardiograph (ECG) gating and frequency filtering. Many of these methods require interventions inappropriate in a clinical setting. This study therefore aims to extend a previously reported frequency filtering technique to a spontaneously breathing cohort and assess the regional distributions of ventilation and perfusion and their relationship. Methods Ten healthy adults were measured during a breath hold and while spontaneously breathing in supine, prone, left and right lateral positions. EIT data were analysed with and without filtering at the respiratory and heart rate. Profiles of ventilation, perfusion and ventilation/perfusion related impedance change were generated and regions of ventilation and pulmonary perfusion were identified and compared. Results Analysis of the filtration technique demonstrated its ability to separate the ventilation and cardiac related impedance signals without negative impact. It was, therefore, deemed suitable for use in this spontaneously breathing cohort. Regional distributions of ventilation, perfusion and the combined ΔZV/ΔZQ were calculated along the gravity axis and anatomically in each position. Along the gravity axis, gravity dependence was seen only in the lateral positions in ventilation distribution, with the dependent lung being better ventilated regardless of position. This gravity dependence was not seen in perfusion. When looking anatomically, differences were only apparent in the lateral positions. The lateral position ventilation distributions showed a difference in the left lung, with the right lung maintaining a similar distribution in both lateral positions. This is likely caused by more pronounced anatomical changes in the left lung when changing positions. Conclusions The modified filtration technique was demonstrated to be effective in separating the ventilation and perfusion signals in spontaneously breathing subjects. Gravity dependence was seen only in ventilation distribution in the left lung in lateral positions, suggesting gravity based shifts in anatomical structures. Gravity dependence was not seen in any perfusion distributions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total hip arthroplasty (THA) has a proven clinical record for providing pain relief and return of function to patients with disabling arthritis. There are many successful options for femoral implant design and fixation. Cemented, polished, tapered femoral implants have been shown to have excellent results in national joint registries and long-term clinical series. These implants are usually 150mm long at their lateral aspect. Due to their length, these implants cannot always be offered to patients due to variations in femoral anatomy. Polished, tapered implants as short as 95mm exist, however their small proximal geometry (neck offset and body size) limit their use to smaller stature patients. There is a group of patients in which a shorter implant with a maintained proximal body size would be advantageous. There are also potential benefits to a shorter implant in standard patient populations such as reduced bone removal due to reduced reaming, favourable loading of the proximal femur, and the ability to revise into good proximal bone stock if required. These factors potentially make a shorter implant an option for all patient populations. The role of implant length in determining the stability of a cemented, polished, tapered femoral implant is not well defined by the literature. Before changes in implant design can be made, a better understanding of the role of each region in determining performance is required. The aim of the thesis was to describe how implant length affects the stability of a cemented, polished, tapered femoral implant. This has been determined through an extensive body of laboratory testing. The major findings are that for a given proximal body size, a reduction in implant length has no effect on the torsional stability of a polished, tapered design, while a small reduction in axial stability should be expected. These findings are important because the literature suggests that torsional stability is the major determinant of long-term clinical performance of a THA system. Furthermore, a polished, tapered design is known to be forgiving of cement-implant interface micromotion due to the favourable wear characteristics. Together these findings suggest that a shorter polished, tapered implant may be well tolerated. The effect of a change in implant length on the geometric characteristics of polished, tapered design were also determined and applied to the mechanical testing. Importantly, interface area does play a role in stability of the system; however it is the distribution of the interface and not the magnitude of the area that defines stability. Taper angle (at least in the range of angles seen in this work) was shown not to be a determinant of axial or torsional stability. A range of implants were tested, comparing variations in length, neck offset and indication (primary versus cement-in-cement revision). At their manufactured length, the 125mm implants were similar to their longer 150mm counterparts suggesting that they may be similarly well tolerated in the clinical environment. However, the slimmer cement-in-cement revision implant was shown to have a poorer mechanical performance, suggesting their use in higher demand patients may be hazardous. An implant length of 125mm has been shown to be quite stable and the results suggest that a further reduction to 100mm may be tolerated. However, further work is required. A shorter implant with maintained proximal body size would be useful for the group of patients who are unable to access the current standard length implants due to variations in femoral anatomy. Extending the findings further, the similar function with potential benefits of a shorter implant make their application to all patients appealing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Parents are at risk for inactivity; however, research into understanding parental physical activity (PA) is scarce. We integrated self-determined motivation, planning, and the theory of planned behavior (TPB) to better understand parental PA. Parents (252 mothers, 206 fathers) completed a main questionnaire assessing measures underpinning these constructs and a 1-week follow-up of PA behavior to examine whether self-determined motivation indirectly influenced intention via the TPB variables (i.e., attitude, subjective norm, and perceived behavioral control) and intention indirectly influenced behavior via planning. We found self-determined motivation on intention was fully mediated by the TPB variables and intention on behavior was partially mediated by the planning variables. In addition, slight differences in the model’s paths between the sexes were revealed. The results illustrate the range of important determinants of parental PA and provide support for the integrated model in explaining PA decision making as well as the importance of examining sex differences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aggressive driving is considered an important road-safety concern for drivers in highly motorised countries. However, understanding of the causes and maintenance factors fundamental to aggressive driving is limited. In keeping with theoretical advances from general aggression research such as the General Aggression Model (GAM), research has begun to examine the emotional and cognitive antecedents of aggressive driving in order to better understand the underlying processes motivating aggressive driving. Early findings in the driving area have suggested that greater levels of aggression are elicited in response to an intentionally aggressive on-road event. In contrast, general aggression research suggests that greater levels of aggression are elicited in response to an ambiguous event. The current study examined emotional and cognitive responses to two hypothetical driving scenarios with differing levels of aggressive intent (intentional versus ambiguous). There was also an interest in whether factors influencing responses were different for hostile aggression (that is, where the action is intended to harm the other) versus instrumental aggression (that is, where the action is motivated by an intention to remove an impediment or attain a goal). Results were that significantly stronger negative emotion and negative attributions, as well as greater levels of threat were reported in response to the scenario which was designed to appear intentional in nature. In addition, participants were more likely to endorse an aggressive behavioural response to a situation that appeared deliberately aggressive than to one where the intention was ambiguous. Analyses to determine if greater levels of negative emotions and cognitions are able to predict aggressive responses provided different patterns of results for instrumental aggression from those for hostile aggression. Specifically, for instrumental aggression, negative emotions and negative attributions were significant predictors for both the intentional and the ambiguous scenarios. In addition, perceived threat was also a significant predictor where the other driver’s intent was clearly aggressive. However, lower rather than higher, levels of perceived threat were associated with greater endorsement of an aggressive response. For hostile aggressive behavioural responses, trait aggression was the strongest predictor for both situations. Overall the results suggest that in the driving context, instrumental aggression is likely to be a much more common response than hostile aggression. Moreover, aggressive responses are more likely in situations where another driver’s behaviour is clearly intentional rather than ambiguous. The results also support the conclusion that there may be different underlying mechanisms motivating an instrumental aggressive response to those motivating a hostile one. In addition, understanding the emotions and cognitions underlying aggressive driving responses may be helpful in predicting and intervening to reduce driving aggression. The finding that drivers appear to regard tailgating as an instrumental response is of concern since this behaviour has the potential to result in crashes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

13.1 Drugs for cardiac arrhythmias 13.1.1 Introduction to cardiac arrhythmias 13.1.2 Cardiac action potentials 13.1.3 Mechanisms of cardiac arrhythmias 13.1.3 Class I 13.1.4 Class II 13.1.5 Class III 12.1.6 Class IV 13.1.7 Amiodarone 13.1.8 Adenosine 13.2 Antithrombotic drugs 13.2.1 Thrombus formation 13.2.2 Platelet aggregation and anti-platelet drugs 13.2.3 Coagulation 13.2.4 Anticoagulants 13.2.5 Fibrinolysis and fibrinolytics 13.3. Lipid modulating drugs 13.3.1 Cholesterol 13.3.2 Statins 13.3.3 Fibric acid derivatives 13.3.4 Ezetimibe

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/Aims Timely access to appropriate cardiac care is critical for optimizing positive outcomes after a cardiac event. Attendance at cardiac rehabilitation (CR) remains less than optimal (10%–30%). Our aim was to derive an objective, comparable, geographic measure reflecting access to cardiac services after a cardiac event in Australia. Methods An expert panel defined a single patient care pathway and a hierarchy of the minimum health services for CR and secondary prevention. Using geographic information systems a numeric/alpha index was modelled to describe access before and after a cardiac event. The aftercare phase was modelled into five alphabetical categories: from category A (access to medical service, pharmacy, CR, pathology within 1 h) to category E (no services available within 1 h). Results Approximately 96% or 19 million people lived within 1 h of the four basic services to support CR and secondary prevention, including 96% of older Australians and 75% of the indigenous population. Conversely, 14% (64,000) indigenous people resided in population locations that had poor access to health services that support CR after a cardiac event. Conclusion Results demonstrated that the majority of Australians had excellent ‘geographic’ access to services to support CR and secondary prevention. Therefore, it appears that it is not the distance to services that affects attendance. Our ‘geographic’ lens has identified that more research on socioeconomic, sociological or psychological aspects to attendance is needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Heart failure (HF) is the leading cause of hospitalization and significant burden to the health care system in Australia. To reduce hospitalizations, multidisciplinary approaches and enhance self-management programs have been strongly advocated for HF patients globally. HF patients who can effectively manage their symptoms and adhere to complex medicine regimes will experience fewer hospitalizations. Research indicates that information technologies (IT) have a significant role in providing support to promote patients' self-management skills. The iPad utilizes user-friendly interfaces and to date an application for HF patient education has not been developed. This project aimed to develop the HF iPad teaching application in the way that would be engaging, interactive and simple to follow and usable for patients' carers and health care workers within both the hospital and community setting. Methods: The design for the development and evaluation of the application consisted of two action research cycles. Each cycle included 3 phases of testing and feedback from three groups comprising IT team, HF experts and patients. All patient education materials of the application were derived from national and international evidence based practice guidelines and patient self-care recommendations. Results: The iPad application has animated anatomy and physiology that simply and clearly teaches the concepts of the normal heart and the heart in failure. Patient Avatars throughout the application can be changed to reflect the sex and culture of the patient. There is voice-over presenting a script developed by the heart failure expert panel. Additional engagement processes included points of interaction throughout the application with touch screen responses and the ability of the patient to enter their weight and this data is secured and transferred to the clinic nurse and/or research data set. The application has been used independently, for instance, at home or using headphones in a clinic waiting room or most commonly to aid a nurse-led HF consultation. Conclusion: This project utilized iPad as an educational tool to standardize HF education from nurses who are not always heart failure specialists. Furthermore, study is currently ongoing to evaluate of the effectiveness of this tool on patient outcomes and to develop several specifically designed cultural adaptations [Hispanic (USA), Aboriginal (Australia), and Maori (New Zealand)].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/Aims Timely access to appropriate cardiac care is critical for optimizing positive outcomes after a cardiac event. Attendance at cardiac rehabilitation (CR) remains less than optimal (10%–30%). Our aim was to derive an objective, comparable, geographic measure reflecting access to cardiac services after a cardiac event in Australia. Methods An expert panel defined a single patient care pathway and a hierarchy of the minimum health services for CR and secondary prevention. Using geographic information systems a numeric/alpha index was modelled to describe access before and after a cardiac event. The aftercare phase was modelled into five alphabetical categories: from category A (access to medical service, pharmacy, CR, pathology within 1 h) to category E (no services available within 1 h). Results Approximately 96% or 19 million people lived within 1 h of the four basic services to support CR and secondary prevention, including 96% of older Australians and 75% of the indigenous population. Conversely, 14% (64,000) indigenous people resided in population locations that had poor access to health services that support CR after a cardiac event. Conclusion Results demonstrated that the majority of Australians had excellent ‘geographic’ access to services to support CR and secondary prevention. Therefore, it appears that it is not the distance to services that affects attendance. Our ‘geographic’ lens has identified that more research on socioeconomic, sociological or psychological aspects to attendance is needed.