Bomb technicians perform their work while encapsulated in explosive ordnance disposal (EOD) suits. Designed primarily for safety, these suits have an unintended consequence of impairing the body’s natural mechanisms for heat dissipation. Purpose: To quantify the heat strain encountered during an EOD operational scenario in the tropical north of Australia. Methods: All active police male bomb technicians, located in a tropical region of Australia (n=4, experience 7 ± 2.1 yrs, age 34 ± 2 yrs, height 182.3 ± 5.4 cm, body mass 95 ± 4 kg, VO2max 46 ± 5.7 ml.kg-1.min-1) undertook an operational scenario wearing the Med-Eng EOD 9 suit and helmet (~32 kg). The climatic conditions ranged between 27.1–31.8°C ambient temperature, 66-88% relative humidity, and 30.7-34.3°C wet bulb globe temperature. The scenario involved searching a two story non air-conditioned building for a target; carrying and positioning equipment for taking an X-ray; carrying and positioning equipment to disrupt the target; and finally clearing the site. Core temperature and heart rate were continuously monitored, and were used to calculate a physiological strain index (PSI). Urine specific gravity (USG) assessed hydration status and heat associated symptomology were also recorded. Results: The scenario was completed in 121 ± 22 mins (23.4 ± 0.4% work, 76.5 ± 0.4% rest/recovery). Maximum core temperature (38.4 ± 0.2°C), heart rate (173 ± 5.4 bpm, 94 ± 3.3% max), PSI (7.1 ± 0.4) and USG (1.031 ± 0.002) were all elevated after the simulated operation. Heat associated symptomology highlighted that moderate-severe levels of fatigue and thirst were universally experienced, muscle weakness and heat sensations experienced by 75%, and one bomb technician reported confusion and light-headedness. Conclusion: All bomb technicians demonstrated moderate-high levels of heat strain, evidenced by elevated heart rate, core body temperature and PSI. Severe levels of dehydration and noteworthy heat-related symptoms further highlight the risks to health and safety faced by bomb technicians operating in tropical locations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The aim was to assess the effects of a Tai Chi based program on health related quality of life (HR-QOL) in people with elevated blood glucose or diabetes who were not on medication for glucose control. Method 41 participants were randomly allocated to either a Tai Chi intervention group (N = 20) or a usual medical care control group (N = 21). The Tai Chi group involved 3 x 1.5 hour supervised and group-based training sessions per week for 12 weeks. Indicators of HR-QOL were assessed by self-report survey immediately prior to and after the intervention. Results There were significant improvements in favour of the Tai Chi group for the SF36 subscales of physical functioning (mean difference = 5.46, 95% CI = 1.35-9.57, P < 0.05), role physical (mean difference = 18.60, 95% CI = 2.16-35.05, P < 0.05), bodily pain (mean difference = 9.88, 95%CI = 2.06-17.69, P < 0.05) and vitality (mean difference = 9.96, 95% CI = 0.77-19.15, P < 0.05). Conclusions The findings show that this Tai Chi program improved indicators of HR-QOL including physical functioning, role physical, bodily pain and vitality in people with elevated blood glucose or diabetes who were not on diabetes medication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerical investigation on mixed convection of a two-dimensional incompressible laminar flow over a horizontal flat plate with streamwise sinusoidal distribution of surface temperature has been performed for different values of Rayleigh number, Reynolds number and frequency of periodic temperature for constant Prandtl number and amplitude of periodic temperature. Finite element method adapted to rectangular non-uniform mesh elements by a non-linear parametric solution algorithm basis numerical scheme has been employed. The investigating parameters are the Rayleigh number, the Reynolds number and frequency of periodic temperature. The effect of variation of individual investigating parameters on mixed convection flow characteristics has been studied to observe the hydrodynamic and thermal behavior for while keeping the other parameters constant. The fluid considered in this study is air with Prandtl number 0.72. The results are obtained for the Rayleigh number range of 102 to 104, Reynolds number ranging from 1 to 100 and the frequency of periodic temperature from 1 to 5. Isotherms, streamlines, average and local Nusselt numbers are presented to show the effect of the different values of aforementioned investigating parameters on fluid flow and heat transfer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accurate thin-film energy dispersive spectroscopic (EDS) analyses of clays with low-atomic-number (low Z) elements (e.g. Na, Al, Si), presents a challenge to the microscopist not only because of the spatial resolution required, but also because of their susceptibility to electron beam-induced radiation damange and very low X-ray count rates. Most common clays, such as kaolinite, smectite and illite occur as submicrometer crystallites with varying degrees of structural disorder in at least two directions and may have dimensions as small as one or two unit cells along the basal direction. Thus, even clays with relatively large a-b dimenstions (e.g., 100 x 100 nm) may be <5nm in the c-axis direction. For typical conditions in an analytical electron microscope (AEM), this sample thickness gives rise to very poor count rates (<200cps) and necessitates long counting times (>300s) in order to obtain satisfactory statistical precision. Unfortunately, beam damage rates for the common clays are very rapid (<10s in imaging mode) between 100kV and 200kV. With a focussed probe for elemental analyses, the damage rate is exacerbated by a high current density and may result in loss of low-Z elements during data collection and consequent loss of analytical accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Preliminary data is presented on a detailed statistical analysis of k-factor determination for a single class of minerals (amphiboles) which contain a wide range of element concentrations. These amphiboles are homogeneous, contain few (if any) subsolidus microstructures and can be readily prepared for thin film analysis. In previous studies, element loss during the period of irradiation has been assumed negligible for the determination of k-factors. Since this phenomena may be significant for certain mineral systems, we also report on the effect of temperature on k-factor determination for various elements using small probe sizes (approx.20 nm).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herein the mechanical properties of graphene, including Young’s modulus, fracture stress and fracture strain have been investigated by molecular dynamics simulations. The simulation results show that the mechanical properties of graphene are sensitive to the temperature changes but insensitive to the layer numbers in the multilayer graphene. Increasing temperature exerts adverse and significant effects on the mechanical properties of graphene. However, the adverse effect produced by the increasing layer number is marginal. On the other hand, isotope substitutions in graphene play a negligible role in modifying the mechanical properties of graphene.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Although many studies have shown that high temperatures are associated with an increased risk of mortality and morbidity, there has been little research on managing the process of planned adaptation to alleviate the health effects of heat events and climate change. In particular, economic evaluation of public health adaptation strategies has been largely absent from both the scientific literature and public policy discussion. OBJECTIVES: his paper aims to discuss how public health organizations should implement adaptation strategies, and how to improve the evidence base for policies to protect health from heat events and climate change. DISCUSSION: Public health adaptation strategies to cope with heat events and climate change fall into two categories: reducing the heat exposure and managing the health risks. Strategies require a range of actions, including timely public health and medical advice, improvements to housing and urban planning, early warning systems, and the assurance that health care and social systems are ready to act. Some of these actions are costly, and the implementation should be based on the cost-effectiveness analysis given scarce financial resources. Therefore, research is required not only on the temperature-related health costs, but also on the costs and benefits of adaptation options. The scientific community must ensure that the health co-benefits of climate change policies are recognized, understood and quantified. CONCLUSIONS: The integration of climate change adaptation into current public health practice is needed to ensure they increase future resilience. The economic evaluation of temperature-related health costs and public health adaptation strategies are particularly important for policy decisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Hot and cold temperatures have been associated with childhood asthma. However, the relationship between daily temperature variation and childhood asthma is not well understood. This study aimed to examine the relationship between diurnal temperature range (DTR) and childhood asthma. METHODS: A Poisson generalized linear model combined with a distributed lag non-linear model was used to examine the relationship between DTR and emergency department admissions for childhood asthma in Brisbane, from January 1st 2003 to December 31st 2009. RESULTS: There was a statistically significant relationship between DTR and childhood asthma. The DTR effect on childhood asthma increased above a DTR of 10[degree sign]C. The effect of DTR on childhood asthma was the greatest for lag 0--9 days, with a 31% (95% confidence interval: 11% -- 58%) increase of emergency department admissions per 5[degree sign]C increment of DTR. Male children and children aged 5--9 years appeared to be more vulnerable to the DTR effect than others. CONCLUSIONS: Large DTR may trigger childhood asthma. Future measures to control and prevent childhood asthma should include taking temperature variability into account. More protective measures should be taken after a day of DTR above10[degree sign]C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concepts used in this chapter include: Thermoregulation:- Thermoregulation refers to the body’s sophisticated, multi-system regulation of core body temperature. This hierarchical system extends from highly thermo-sensitive neurons in the preoptic region of the brain proximate to the rostral hypothalamus, down to the brain stem and spinal cord. Coupled with receptors in the skin and spine, both central and peripheral information on body temperature is integrated to inform and activate the homeostatic mechanisms which maintain our core temperature at 37oC1. Hyperthermia:- An imbalance between the metabolic and external heat accumulated in the body and the loss of heat from the body2. Exertional heat stroke:- A disorder of excessive heat production coupled with insufficient heat dissipation which occurs in un-acclimated individuals who are engaging in over-exertion in hot and humid conditions. This phenomenon includes central nervous system dysfunction and critical dysfunction to all organ systems including renal, cardiovascular, musculoskeletal and hepatic functions. Non-exertional heat stroke:- In contrast to exertional heatstroke as a consequence of high heat production during strenuous exercise, non-exertional heatstroke results from prolonged exposure to high ambient temperature. The elderly, those with chronic health conditions and children are particularly susceptible.3 Rhabdomylosis:- An acute, sometimes fatal disease characterised by destruction of skeletal muscle. In exertional heat stroke, rhabdomylosis occurs in the context of strenuous exercise when mechanical and/or metabolic stress damages the skeletal muscle, causing elevated serum creatine kinease. Associated with this is the potential development of hyperkalemia, myoglobinuria and renal failure. Malignant hyperthermia:- Malignant hyperthermia is “an inherited subclinical myopathy characterised by a hypermetabolic reaction during anaesthesia. The reaction is related to skeletal muscle calcium dysregulation triggered by volatile inhaled anaesthetics and/or succinylcholine.”4 Presentation includes skeletal muscle rigidity, mixed metabolic and respiratory acidosis, tachycardia, hyperpyrexia, rhabdomylosis, hyperkalaemia, elevated serum creatine kinease, multi-organ failure, disseminated intravascular coagulation and death.5

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to determine the effect of carbohydrate (CHO; sucrose) ingestion and environmental heat on the development of fatigue and the distribution of power output during a 16.1-km cycling time trial. Ten male cyclists (Vo(2max) = 61.7 +/- 5.0 ml.kg(-1).min(-1), mean +/- SD) performed four 90-min constant-pace cycling trials at 80% of second ventilatory threshold (220 +/- 12 W). Trials were conducted in temperate (18.1 +/- 0.4 degrees C) or hot (32.2 +/- 0.7 degrees C) conditions during which subjects ingested either CHO (0.96 g.kg(-1).h(-1)) or placebo (PLA) gels. All trials were followed by a 16.1-km time trial. Before and immediately after exercise, percent muscle activation was determined using superimposed electrical stimulation. Power output, integrated electromyography (iEMG) of vastus lateralis, rectal temperature, and skin temperature were recorded throughout the trial. Percent muscle activation significantly declined during the CHO and PLA trials in hot (6.0 and 6.9%, respectively) but not temperate conditions (1.9 and 2.2%, respectively). The decline in power output during the first 6 km was significantly greater during exercise in the heat. iEMG correlated significantly with power output during the CHO trials in hot and temperate conditions (r = 0.93 and 0.73; P < 0.05) but not during either PLA trial. In conclusion, cyclists tended to self-select an aggressive pacing strategy (initial high intensity) in the heat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the effects of post-exercise cooling on recovery of neuromuscular, physiological, and cerebral hemodynamic responses after intermittent-sprint exercise in the heat. Nine participants underwent three post-exercise recovery trials, including a control (CONT), mixed-method cooling (MIX), and cold-water immersion (10 °C; CWI). Voluntary force and activation were assessed simultaneously with cerebral oxygenation (near-infrared spectroscopy) pre- and post-exercise, post-intervention, and 1-h and 24-h post-exercise. Measures of heart rate, core temperature, skin temperature, muscle damage, and inflammation were also collected. Both cooling interventions reduced heart rate, core, and skin temperature post-intervention (P < 0.05). CWI hastened the recovery of voluntary force by 12.7 ± 11.7% (mean ± SD) and 16.3 ± 10.5% 1-h post-exercise compared to MIX and CONT, respectively (P < 0.01). Voluntary force remained elevated by 16.1 ± 20.5% 24-h post-exercise after CWI compared to CONT (P < 0.05). Central activation was increased post-intervention and 1-h post-exercise with CWI compared to CONT (P < 0.05), without differences between conditions 24-h post-exercise (P > 0.05). CWI reduced cerebral oxygenation compared to MIX and CONT post-intervention (P < 0.01). Furthermore, cooling interventions reduced cortisol 1-h post-exercise (P < 0.01), although only CWI blunted creatine kinase 24-h post-exercise compared to CONT (P < 0.05). Accordingly, improvements in neuromuscular recovery after post-exercise cooling appear to be disassociated with cerebral oxygenation, rather reflecting reductions in thermoregulatory demands to sustain force production.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thermal decomposition and dehydroxylation process of coal-bearing strata kaolinite–potassium acetate intercalation complex (CSKK) has been studied using X-ray diffraction (XRD), infrared spectroscopy (IR), thermal analysis, mass spectrometric analysis and infrared emission spectroscopy. The XRD results showed that the potassium acetate (KAc) have been successfully intercalated into coal-bearing strata kaolinite with an obvious basal distance increase of the first basal peak, and the positive correlation was found between the concentration of intercalation regent KAc and the degree of intercalation. As the temperature of the system is raised, the formation of KHCO3, KCO3 and KAlSiO4, which is derived from the thermal decomposition or phase transition of CSKK, is observed in sequence. The IR results showed that new bands appeared, the position and intensities shift can also be found when the concentration of intercalation agent is raised. The thermal analysis and mass spectrometric analysis results revealed that CSKK is stable below 300 °C, and the thermal decomposition products (H2O and CO2) were further proved by the mass spectrometric analysis. A comparison of thermal analysis results of original coal-bearing strata kaolinite and its intercalation complex gives new discovery that not only a new mass loss peak is observed at 285 °C, but also the temperature of dehydroxylation and dehydration of coal bearing strata kaolinite is decreased about 100 °C. This is explained on the basis of the interlayer space of the kaolinite increased obviously after being intercalated by KAc, which led to the interlayer hydrogen bonds weakened, enables the dehydroxylation from kaolinite surface more easily. Furthermore, the possible structural model for CSKK has been proposed, with further analysis required in order to prove the most possible structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Series reactors are used in distribution grids to reduce the short-circuit fault level. Some of the disadvantages of the application of these devices are the voltage drop produced across the reactor and the steep front rise of the transient recovery voltage (TRV), which generally exceeds the rating of the associated circuit breaker. Simulations were performed to compare the characteristics of a saturated core High-Temperature Superconducting Fault Current Limiter (HTS FCL) and a series reactor. The design of the HTS FCL was optimized using the evolutionary algorithm. The resulting Pareto frontier curve of optimum solution is presented in this paper. The results show that the steady-state impedance of an HTS FCL is significantly lower than that of a series reactor for the same level of fault current limiting. Tests performed on a prototype 11 kV HTS FCL confirm the theoretical results. The respective transient recovery voltages (TRV) of the HTS FCL and an air core reactor of comparable fault current limiting capability are also determined. The results show that the saturated core HTS FCL has a significantly lower effect on the rate of rise of the circuit breaker TRV as compared to the air core reactor. The simulations results are validated with shortcircuit test results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As a novel sensitive element and due to its advantages of immunity to electrical interference, distributed measurement, etc., fiber Bragg grating (FBG) has been researched widely. To realize the substitution of high accurate electronic temperature sensors, high sensitive FBG temperature sensors can be made by taking advantage of its characters of being sensitive to both temperature and strain. Although there are reports about high sensitive FBG temperature sensors, however, few about their stability have been done. We manufactured a high sensitive FBG temperature sensor, and put it together with an average FBG temperature sensor and an electronic crystal temperature sensor into a stainless steel container filled by water to observe the room temperature change. By comparing their results in two weeks, we have found out that: although the high sensitive FBG temperature sensor is in much better agreement with the electronic crystal sensor than the average FBG sensor is, it has occurred some small drifts. Because the drifts appeared in the process of further pulling the FBG, it might be a result of the slip of the FBG fixing points. This contributes some good experiences to the application of FBG in high accuracy temperature measurement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method of making full use of the durable strain which fiber Bragg grating (FBG) can undertake is presented, which hugely improves the sensitivities of FBG temperature sensors at high temperature. When a sensor is manufactured at room temperature, its FBG should be given a pre-relaxing length according to the temperature it is asked to measure; once the temperature rise to the asked one, its FBG starts to be stretched and it starts to work with high sensitivity. The relationship between the pre-relaxing length and the working temperature is analyzed. In experiments, when the pre-relaxing lengths are 0.2mm、0.5mm、0.6mm, the working temperatures rise 25℃、50℃、61℃, respectively, and the sensitivities are almost the same (675pm/℃). The facts that the experimental results agree well with the theoretical analyses verify this method’s validity.