155 resultados para Severe Plastic-Deformation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bien Hoa Airbase was one of the bulk storage and supply facilities for defoliants during the Vietnam War. Environmental and biological samples taken around the airbase have elevated levels of dioxin. In 2007, a pre-intervention knowledge, attitude and practice (KAP) survey of local residents living in Trung Dung and Tan Phong wards was undertaken regarding appropriate strategies to reduce dioxin exposure. A risk reduction programme was implemented in 2008 and post-intervention KAP surveys were undertaken in 2009 and 2013 to evaluate the longer term impacts. Quantitative assessment was undertaken via a KAP survey in 2013 among 600 local residents randomly selected from the two intervention wards and one control ward (Buu Long). Eight in-depth interviews and two focus group discussions were also undertaken for qualitative assessment. Most programme activities had ceased and dioxin risk communication activities had not been integrated into local routine health education programmes; however, main results generally remained and were better than that in Buu Long. In total, 48.2% of households undertook measures to prevent exposure, higher than those in pre- and post-intervention surveys (25.8% and 39.7%) and the control ward (7.7%). Migration and the sensitive nature of dioxin issues were the main challenges for the programme's sustainability

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The genetic basis for developing asthma has been extensively studied. However, association studies to date have mostly focused on mild to moderate disease and genetic risk factors for severe asthma remain unclear. Objective: To identify common genetic variants affecting susceptibility to severe asthma. Methods: A genome-wide association study was undertaken in 933 European ancestry individuals with severe asthma based on Global Initiative for Asthma (GINA) criteria 3 or above and 3346 clean controls. After standard quality control measures, the association of 480 889 genotyped single nucleotide polymorphisms (SNPs) was tested. To improve the resolution of the association signals identified, non-genotyped SNPs were imputed in these regions using a dense reference panel of SNP genotypes from the 1000 Genomes Project. Then replication of SNPs of interest was undertaken in a further 231 cases and 1345 controls and a meta-analysis was performed to combine the results across studies. Results: An association was confirmed in subjects with severe asthma of loci previously identified for association with mild to moderate asthma. The strongest evidence was seen for the ORMDL3/GSDMB locus on chromosome 17q12-21 (rs4794820, p=1.03×10 (-8)following meta-analysis) meeting genome-wide significance. Strong evidence was also found for the IL1RL1/IL18R1 locus on 2q12 (rs9807989, p=5.59×10 (-8) following meta-analysis) just below this threshold. No novel loci for susceptibility to severe asthma met strict criteria for genome-wide significance. Conclusions: The largest genome-wide association study of severe asthma to date was carried out and strong evidence found for the association of two previously identified asthma susceptibility loci in patients with severe disease. A number of novel regions with suggestive evidence were also identified warranting further study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of decellularized extracellular matrices to aid tissue regeneration in reconstructive surgery and regenerative medicine has been promising. Several decellularization protocols for removing cellular materials from natural tissues such as heart valves are currently in use. This paper evaluates the feasibility of potential extension of this methodology relative to the desirable properties of load bearing joint tissues such as stiffness, porosity and ability to recover adequately after deformation to facilitate physiological function. Two decellularization protocols, namely: Trypsin and Triton X-100 were evaluated against their effects on bovine articular cartilage, using biomechanical, biochemical and microstructural techniques. These analyses revealed that decellularization with trypsin resulted in severe loss of mechanical stiffness including deleterious collapse of the collagen architecture which in turn significantly compromised the porosity of the construct. In contrast, triton X-100 detergent treatment yielded samples that retain mechanical stiffness relative to that of the normal intact cartilage sample, but the resulting construct contained ruminant cellular constituents. We conclude that both of these common decellularization protocols are inadequate for producing constructs that can serve as effective replacement and scaffolds to regenerate articular joint tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A perfectly plastic von Mises model is proposed to study the elastic-plastic behavior of a porous hierarchical scaffold used for bone regeneration. The proposed constitutive model is implemented in a finite element (FE) routine to obtain the stress-strain relationship of a uniaxially loaded cube of the scaffold, whose constituent is considered to be composed of cortical bone. The results agree well with experimental data for uniaxial loading case of a cancellous bone. We find that the unhomogenized stress distribution results in different mechanical properties from but still comparable to our previous theory. The scaffold is a promising candidate for bone regeneration.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High resolution, USPIO-enhanced MR imaging can be used to identify inflamed atherosclerotic plaque. We report a case of a 79-year-old man with a symptomatic carotid stenosis of 82%. The plaque was retrieved for histology and finite element analysis (FEA) based on the preoperative MR imaging was used to predict maximal Von Mises stress on the plaque. Macrophage location correlated with maximal predicted stresses on the plaque. This supports the hypothesis that macrophages thin the fibrous cap at points of highest stress, leading to an increased risk of plaque rupture and subsequent stroke.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Decompressive hemicraniectomy, clot evacuation, and aneurysmal interventions are considered aggressive surgical therapeutic options for treatment of massive cerebral artery infarction (MCA), intracerebral hemorrhage (ICH), and severe subarachnoid hemorrhage (SAH) respectively. Although these procedures are saving lives, little is actually known about the impact on outcomes other than short-term survival and functional status. The purpose of this study was to gain a better understanding of personal and social consequences of surviving these aggressive surgical interventions in order to aid acute care clinicians in helping family members make difficult decisions about undertaking such interventions. Methods: An exploratory mixed method study using a convergent parallel design was conducted to examine functional recovery (NIHSS, mRS & BI), cognitive status (Montreal Cognitive Assessment Scale, MoCA), quality of life (Euroqol 5-D), and caregiver outcomes (Bakas Caregiver Outcome Scale, BCOS) in a cohort of patients and families who had undergone aggressive surgical intervention for severe stroke between the years 2000–2007. Data were analyzed using descriptive statistics, univariate and multivariate analysis of variance, and multivariate logistic regression. Content analysis was used to analyze the qualitative interviews conducted with stroke survivors and family members. Results: Twenty-seven patients and 13 spouses participated in this study. Based on patient MOCA scores, overall cognitive status was 25.18 (range 23.4-26.9); current functional outcomes scores: NIHSS 2.22, mRS 1.74, and BI 88.5. EQ-5D scores revealed no significant differences between patients and caregivers (p=0.585) and caregiver outcomes revealed no significant differences between male/female caregivers or patient diagnostic group (MCA, SAH, ICH; p=""0.103).<"/span><"/span> Discussion: Overall, patients and families were satisfied with quality of life and decisions made at the time of the initial stroke. There was consensus among study participants that formal community-based support (e.g., handibus, caregiving relief, rehabilitation assessments) should be continued for extended periods (e.g., years) post-stroke. Ongoing contact with health care professionals is valuable to help them navigate in the community as needs change over time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Speed is recognised as a key contributor to crash likelihood and severity, and to road safety performance in general. Its fundamental role has been recognised by making Safe Speeds one of the four pillars of the Safe System. In this context, impact speeds above which humans are likely to sustain fatal injuries have been accepted as a reference in many Safe System infrastructure policy and planning discussions. To date, there have been no proposed relationships for impact speeds above which humans are likely to sustain fatal or serious (severe) injury, a more relevant Safe System measure. A research project on Safe System intersection design required a critical review of published literature on the relationship between impact speed and probability of injury. This has led to a number of questions being raised about the origins, accuracy and appropriateness of the currently accepted impact speed–fatality probability relationships (Wramborg 2005) in many policy documents. The literature review identified alternative, more recent and more precise relationships derived from the US crash reconstruction databases (NASS/CDS). The paper proposes for discussion a set of alternative relationships between vehicle impact speed and probability of MAIS3+ (fatal and serious) injury for selected common crash types. Proposed Safe System critical impact speed values are also proposed for use in road infrastructure assessment. The paper presents the methodology and assumptions used in developing these relationships. It identifies further research needed to confirm and refine these relationships. Such relationships would form valuable inputs into future road safety policies in Australia and New Zealand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated serum cationic trypsinogen as a marker of exocrine pancreatic function in children without cystic fibrosis. The ability of this test to determine steatorrhoea of pancreatic origin, and its relationship to a wide range of exocrine pancreatic function were assessed. Serum trypsinogen was measured in 32 children with steatorrhoea, 10 with pancreatic and 22 with non-pancreatic causes. In patients with pancreatic steatorrhoea, serum cationic trypsinogen was 4·9±4·9 μg/l (mean ±SD), significantly below values in patients with non-pancreatic steatorrhoea (47·0±22·1 μg/l, p<0·001) and 50 control subjects (31·4±7·4 μg/l, p<0·001). Serum cationic trypsinogen values in patients with pancreatic steatorrhoea all fell below the lower limit of our control range and below all values for patients with non-pancreatic steatorrhoea. Serum cationic trypsinogen was also evaluated against pancreatic trypsin output in 47 patients (range 0·2-17·0 yr) who underwent a hormonal pancreatic stimulation test. In 17 patients, serum cationic trypsinogen was low (<-2SD or 16·6 μg/l), and associated with greatly impaired pancreatic trypsin output, ranging from 0-8% of mean normal trypsin output. Five of these 17 patients did not have steatorrhoea. In 30 patients with normal or raised serum cationic trypsinogen (≥16·6 μg/l), pancreatic trypsin output ranged from 15-183% of mean normal values. In conclusion, low serum cationic trypsinogen suggests severely impaired exocrine pancreatic function, with sensitivity extending above the steatorrhoeic threshold. In the presence of steatorrhoea, low serum cationic trypsinogen indicates a pancreatic aetiology. Normal serum cationic trypsinogen, however, does not exclude impaired pancreatic function, above the steatorrhoeic threshold.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The computational technique of the full ranges of the second-order inelastic behaviour evaluation of steel-concrete composite structure is not always sought forgivingly, and therefore it hinders the development and application of the performance-based design approach for the composite structure. To this end, this paper addresses of the advanced computational technique of the higher-order element with the refined plastic hinges to capture the all-ranges behaviour of an entire steel-concrete composite structure. Moreover, this paper presents the efficient and economical cross-section analysis to evaluate the element section capacity of the non-uniform and arbitrary composite section subjected to the axial and bending interaction. Based on the same single algorithm, it can accurately and effectively evaluate nearly continuous interaction capacity curve from decompression to pure bending technically, which is the important capacity range but highly nonlinear. Hence, this cross-section analysis provides the simple but unique algorithm for the design approach. In summary, the present nonlinear computational technique can simulate both material and geometric nonlinearities of the composite structure in the accurate, efficient and reliable fashion, including partial shear connection and gradual yielding at pre-yield stage, plasticity and strain-hardening effect due to axial and bending interaction at post-yield stage, loading redistribution, second-order P-δ and P-Δ effect, and also the stiffness and strength deterioration. And because of its reliable and accurate behavioural evaluation, the present technique can be extended for the design of the high-strength composite structure and potentially for the fibre-reinforced concrete structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anatomically precontoured plates are commonly used to treat periarticular fractures. A well-fitting plate can be used as a tool for anatomical reduction of the fractured bone. Recent studies highlighted that some plates fit poorly for many patients due to considerable shape variations between bones of the same anatomical site. While it is impossible to design one shape that fits all, it is also burdensome for the manufacturers and hospitals to produce, store and manage multiple plate shapes without the certainty of utilization by a patient population. In this study, we investigated the number of shapes required for maximum fit within a given dataset, and if they could be obtained by manually deforming the original plate. A distal medial tibial plate was automatically positioned on 45 individual tibiae, and the optimal deformation was determined iteratively using finite element analysis simulation. Within the studied dataset, we found that: (i) 89% fit could be achieved with four shapes, (ii) 100% fit was impossible through mechanical deformation, and (iii) the deformations required to obtain the four plate shapes were safe for the stainless steel plate for further clinical use. The proposed framework is easily transferable to other orthopaedic plates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neglect of children is a significant social issue worldwide and is typically the most frequently reported form of maltreatment in Western nations, with its severe forms sometimes resulting in significant illness and disablement or death. Yet, paradoxically, it remains ‘neglected’ and largely in the shadow of physical and sexual abuse, often being viewed as less serious despite the real-life consequences of its insidious and compounding nature and the lasting damage it causes to intergenerational familial relationships and the life outcomes of those affected. This chapter explores the many complex forms of child neglect, its causes and impacts and the strategies to prevent it. In particular, a critical standpoint is taken in analysing the rationale and merits of mandatory reporting of neglect and their effects, systemically and for children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis developed an advanced computational model to investigate the motion and deformation properties of red blood cells in capillaries. The novel model is based on the meshfree particle methods and is capable of modelling the large deformation of red blood cells moving through blood vessels. The developed model was employed to simulate the deformation behaviour of healthy and malaria infected red blood cells as well as the motion of red blood cells in stenosed capillaries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After more than twenty years of basic and applied research, the use of nanotechnology in the design and manufacture of nanoscale materials is rapidly increasing, particularly in commercial applications that span from electronics across renewable energy areas, and biomedical devices. Novel polymers are attracting significant attention for they promise to provide a low−cost high−performance alternative to existing materials. Furthermore, these polymers have the potential to overcome limitations imposed by currently available materials thus enabling the development of new technologies and applications that are currently beyond our reach. This work focuses on the development of a range of new low−cost environmentally−friendly polymer materials for applications in areas of organic (flexible) electronics, optics, and biomaterials. The choice of the monomer reflects the environmentally−conscious focus of this project. Terpinen−4−ol is a major constituent of Australian grown Melaleuca alternifolia (tea tree) oil, attributed with the oil's antimicrobial and anti−inflammatory properties. Plasma polymerisation was chosen as a deposition technique for it requires minimal use of harmful chemicals and produces no hazardous by−products. Polymer thin films were fabricated under varied process conditions to attain materials with distinct physico−chemical, optoelectrical, biological and degradation characteristics. The resultant materials, named polyterpenol, were extensively characterised using a number of well−accepted and novel techniques, and their fundamental properties were defined. Polyterpenol films were demonstrated to be hydrocarbon rich, with variable content of oxygen moieties, primarily in the form of hydroxyl and carboxyl functionalities. The level of preservation of original monomer functionality was shown to be strongly dependent on the deposition energy, with higher applied power increasing the molecular fragmentation and substrate temperature. Polyterpenol water contact angle contact angle increased from 62.7° for the 10 W samples to 76.3° for the films deposited at 100 W. Polymers were determined to resist solubilisation by water, due to the extensive intermolecular and intramolecular hydrogen bonds present, and other solvents commonly employed in electronics and biomedical processing. Independent of deposition power, the surface topography of the polymers was shown to be smooth (Rq <0.5 nm), uniform and defect free. Hardness of polyterpenol coatings increased from 0.33 GPa for 10 W to 0.51 GPa for 100 W (at 500 μN load). Coatings deposited at higher input RF powers showed less mechanical deformation during nanoscratch testing, with no considerable damage, cracking or delamination observed. Independent of the substrate, the quality of film adhesion improved with RF power, suggesting these coatings are likely to be more stable and less susceptible to wear. Independent of fabrication conditions, polyterpenol thin films were optically transparent, with refractive index approximating that of glass. Refractive index increased slightly with deposition power, from 1.54 (10 W) to 1.56 (100 W) at 500 nm. The optical band gap values declined with increasing power, from 2.95 eV to 2.64 eV, placing the material within the range for semiconductors. Introduction of iodine impurity reduced the band gap of polyterpenol, from 2.8 eV to 1.64 eV, by extending the density of states more into the visible region of the electromagnetic spectrum. Doping decreased the transparency and increased the refractive index from 1.54 to 1.70 (at 500 nm). At optical frequencies, the real part of permittivity (k) was determined to be between 2.34 and 2.65, indicating a potential low-k material. These permittivity values were confirmed at microwave frequencies, where permittivity increased with input RF energy – from 2.32 to 2.53 (at 10 GHz ) and from 2.65 to 2.83 (at 20 GHz). At low frequencies, the dielectric constant was determined from current−voltage characteristics of Al−polyterpenol−Al devices. At frequencies below 100 kHz, the dielectric constant varied with RF power, from 3.86 to 4.42 at 1 kHz. For all samples, the resistivity was in order of 10⁸−10⁹ _m (at 6 V), confirming the insulating nature of polyterpenol material. In situ iodine doping was demonstrated to increase the conductivity of polyterpenol, from 5.05 × 10⁻⁸ S/cm to 1.20 × 10⁻⁶ S/cm (at 20 V). Exposed to ambient conditions over extended period of time, polyterpenol thin films were demonstrated to be optically, physically and chemically stable. The bulk of ageing occurred within first 150 h after deposition and was attributed to oxidation and volumetric relaxation. Thermal ageing studies indicated thermal stability increased for the films manufactured at higher RF powers, with degradation onset temperature associated with weight loss shifting from 150 ºC to 205 ºC for 10 W and 100 W polyterpenol, respectively. Annealing the films to 405 °C resulted in full dissociation of the polymer, with minimal residue. Given the outcomes of the fundamental characterisation, a number of potential applications for polyterpenol have been identified. Flexibility, tunable permittivity and loss tangent properties of polyterpenol suggest the material can be used as an insulating layer in plastic electronics. Implementation of polyterpenol as a surface modification of the gate insulator in pentacene-based Field Effect Transistor resulted in significant improvements, shifting the threshold voltage from + 20 V to –3 V, enhancing the effective mobility from 0.012 to 0.021 cm²/Vs, and improving the switching property of the device from 10⁷ to 10⁴. Polyterpenol was demonstrated to have a hole transport electron blocking property, with potential applications in many organic devices, such as organic light emitting diodes. Encapsulation of biomedical devices is also proposed, given that under favourable conditions, the original chemical and biological functionality of terpinen−4−ol molecule can be preserved. Films deposited at low RF power were shown to successfully prevent adhesion and retention of several important human pathogens, including P. aeruginosa, S. aureus, and S. epidermidis, whereas films deposited at higher RF power promoted bacterial cell adhesion and biofilm formation. Preliminary investigations into in vitro biocompatibility of polyterpenol demonstrated the coating to be non−toxic for several types of eukaryotic cells, including Balb/c mice macrophage and human monocyte type (HTP−1 non-adherent) cells. Applied to magnesium substrates, polyterpenol encapsulating layer significantly slowed down in vitro biodegradation of the metal, thus increasing the viability and growth of HTP−1 cells. Recently, applied to varied nanostructured titanium surfaces, polyterpenol thin films successfully reduced attachment, growth, and viability of P. aeruginosa and S. aureus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Out-of-plane behaviour of mortared and mortarless masonry walls with various forms of reinforcement, including unreinforced masonry as a base case is examined using a layered shell element based explicit finite element modelling method. Wall systems containing internal reinforcement, external surface reinforcement and intermittently laced reinforced concrete members and unreinforced masonry panels are considered. Masonry is modelled as a layer with macroscopic orthotropic properties; external reinforcing render, grout and reinforcing bars are modelled as distinct layers of the shell element. Predictions from the layered shell model have been validated using several out-of-plane experimental datasets reported in the literature. The model is used to examine the effectiveness of two retrofitting schemes for an unreinforced masonry wall.