165 resultados para Pressure transducers.
Resumo:
Introduction Vascular access devices (VADs), such as peripheral or central venous catheters, are vital across all medical and surgical specialties. To allow therapy or haemodynamic monitoring, VADs frequently require administration sets (AS) composed of infusion tubing, fluid containers, pressure-monitoring transducers and/or burettes. While VADs are replaced only when necessary, AS are routinely replaced every 3–4 days in the belief that this reduces infectious complications. Strong evidence supports AS use up to 4 days, but there is less evidence for AS use beyond 4 days. AS replacement twice weekly increases hospital costs and workload. Methods and analysis This is a pragmatic, multicentre, randomised controlled trial (RCT) of equivalence design comparing AS replacement at 4 (control) versus 7 (experimental) days. Randomisation is stratified by site and device, centrally allocated and concealed until enrolment. 6554 adult/paediatric patients with a central venous catheter, peripherally inserted central catheter or peripheral arterial catheter will be enrolled over 4 years. The primary outcome is VAD-related bloodstream infection (BSI) and secondary outcomes are VAD colonisation, AS colonisation, all-cause BSI, all-cause mortality, number of AS per patient, VAD time in situ and costs. Relative incidence rates of VAD-BSI per 100 devices and hazard rates per 1000 device days (95% CIs) will summarise the impact of 7-day relative to 4-day AS use and test equivalence. Kaplan-Meier survival curves (with log rank Mantel-Cox test) will compare VAD-BSI over time. Appropriate parametric or non-parametric techniques will be used to compare secondary end points. p Values of <0.05 will be considered significant.
Resumo:
This work investigates the academic stress and mental health of Indian high school students and the associations between various psychosocial factors and academic stress. A total of190 students from grades 11 and 12 (mean age: 16.72 years) from three government-aided and three private schools in Kolkata India were surveyed in the study. Data collection involved using a specially designed structured questionnaire as well as the General Health Questionnaire. Nearly two-thirds (63.5%) of the students reported stress due to academic pressure – with no significant differences across gender, age, grade, and several other personal factors. About two-thirds (66%) of the students reported feeling pressure from their parents for better academic performance. The degree of parental pressure experienced differed significantly across the educational levels of the parents, mother’s occupation, number of private tutors, and academic performance. In particular, children of fathers possessing a lower education level (non-graduates) were found to be more likely to perceive pressure for better academic performance. About one-thirds (32.6%) of the students were symptomatic of psychiatric caseness and 81.6% reported examination-related anxiety. Academic stress was positively correlated with parental pressure and psychiatric problems, while examination-related anxiety also was positively related to psychiatric problems. Academic stress is a serious issue which affects nearly two thirds of senior high school students in Kolkata. Potential methods for combating the challenges of academic pressure are suggested.
Resumo:
Tight networks of interwoven carbon nanotube bundles are formed in our highly conductive composite. The composite possesses propertiessuggesting a two-dimensional percolative network rather than other reported dispersions displaying three-dimensional networks. Binding nanotubes into large but tight bundles dramatically alters the morphology and electronic transport dynamics of the composite. This enables itto carry higher levels of charge in the macroscale leading to conductivities as high as 1600 S/cm. We now discuss in further detail, the electronic and physical properties of the nanotube composites through Raman spectroscopy and transmission electron microscopy analysis. When controlled and usedappropriately, the interesting properties of these composites reveal their potential for practical device applications. For instance, we used this composite to fabricate coatings, whic improve the properties of an electromagnetic antenna/amplifier transducer. The resulting transducer possesses a broadband range up to GHz frequencies. A strain gauge transducer was also fabricated using changes in conductivity to monitor structural deformations in the composite coatings.
Resumo:
We sought to evaluate central corneal thickness (CCT), corneal endothelial cell density (ECD) and intraocular pressure (IOP) in patients with type 2 diabetes mellitus (DM) and to associate potential differences with diabetes duration and treatment modality in a prospective, randomized study. We measured ECD, CCT and IOP of 125 patients with type 2 DM (mean age 57.1¡11.5 years) and compared them with 90 age-matched controls. Measured parameters were analyzed for association with diabetes duration and glucose control modalities (insulin injection or oral medication) while controlling for age. In the diabetic group, the mean ECD (2511¡252 cells/mm2), mean CCT (539.7¡33.6 mm) and mean IOP (18.3¡2.5 mmHg) varied significantly from those the control group [ECD: 2713¡132 cells/mm2 (P,0.0001), CCT: 525.0¡45.3 mm (P50.003) and IOP: 16.7¡1.8 mmHg (P,0.0001)]. ECD was significantly reduced by about 32 cell/mm2 for diabetics with duration of .10 years when compared with those with duration of ,10 years (P,0.05). CCT was thicker and IOP was higher for diabetics with duration of .10 years than those with duration of ,10 years (P.0.05). None of the measured parameters was significantly associated with diabetes duration and treatment modality (P.0.05). In conclusion, subjects with type 2 DM exhibit significant changes in ECD, IOP and CCT, which, however, are not correlated with disease duration or if the patients receive on insulin injection or oral medications.
Resumo:
In this study of 638 Australian nurses, compliance to hand hygiene (HH), as defined by the “five moments” recommended by the World Health Organisation (2009), was examined. Hypotheses focused on the extent to which time pressure reduces compliance and safety climate (operationalised in relation to HH using colleagues, manager, and hospital as referents) increases compliance. It also was proposed that HH climate would interact with time pressure, such that the negative effects of time pressure would be less marked when HH climate is high. The extent to which the three HH climate variables would interact among each other, either in the form of boosting or compensatory effects, was tested in an exploratory manner. A prospective research design was used in which time pressure and the HH climate variables were assessed at Time 1 and compliance was assessed by self-report two weeks later. Compliance was high but varied significantly across the 5 HH Moments, suggesting that nurses make distinctions between inherent and elective HH and also seemed to engage in some implicit rationing of HH. Time pressure dominated the utility of HH climate to have its positive impact on compliance. The most conducive workplace for compliance was one low in time pressure and high in HH climate. Colleagues were very influential in determining compliance, more so than the manager and hospital. Manager and hospital support for HH enhanced the positive effects of colleagues on compliance. Providing training and enhancing knowledge was important, not just for compliance, but for safety climate.
Resumo:
Changes to the redox status of biological systems have been implicated in the pathogenesis of a wide variety of disorders including cancer, Ischemia-reperfusion (I/R) injury and neurodegeneration. In times of metabolic stress e.g. ischaemia/reperfusion, reactive oxygen species (ROS) production overwhelms the intrinsic antioxidant capacity of the cell, damaging vital cellular components. The ability to quantify ROS changes in vivo, is therefore essential to understanding their biological role. Here we evaluate the suitability of a novel reversible profluorescent probe containing a redox-sensitive nitroxide moiety (methyl ester tetraethylrhodamine nitroxide, ME-TRN), as an in vivo, real-time reporter of retinal oxidative status. The reversible nature of the probe's response offers the unique advantage of being able to monitor redox changes in both oxidizing and reducing directions in real time. After intravitreal administration of the ME-TRN probe, we induced ROS production in rat retina using an established model of complete, acute retinal ischaemia followed by reperfusion. After restoration of blood flow, retinas were imaged using a Micron III rodent fundus fluorescence imaging system, to quantify the redox-response of the probe. Fluorescent intensity declined during the first 60 min of reperfusion. The ROS-induced change in probe fluorescence was ameliorated with the retinal antioxidant, lutein. Fluorescence intensity in non-Ischemia eyes did not change significantly. This new probe and imaging technology provide a reversible and real-time response to oxidative changes and may allow the in vivo testing of antioxidant therapies of potential benefit to a range of diseases linked to oxidative stress
Resumo:
Atmospheric pressure gas plasma (AGP) generates reactive oxygen species (ROS) that induce apoptosis in cultured cancer cells. The majority of cancer cells develop a ROS-scavenging anti-oxidant system regulated by Nrf2, which confers resistance to ROS-mediated cancer cell death. Generation of ROS is involved in the AGP-induced cancer cell death of several colorectal cancer cells (Caco2, HCT116 and SW480) by activation of ASK1-mediated apoptosis signaling pathway without affecting control cells (human colonic sub-epithelial myofibroblasts; CO18, human fetal lung fibroblast; MRC5 and fetal human colon; FHC). However, the identity of an oxidase participating in AGP-induced cancer cell death is unknown. Here, we report that AGP up-regulates the expression of Nox2 (NADPH oxidase) to produce ROS. RNA interference designed to target Nox2 effectively inhibits the AGP-induced ROS production and cancer cell death. In some cases both colorectal cancer HT29 and control cells showed resistance to AGP treatment. Compared to AGP-sensitive Caco2 cells, HT29 cells show a higher basal level of the anti-oxidant system transcriptional regulator Nrf2 and its target protein sulfiredoxin (Srx) which are involved in cellular redox homeostasis. Silencing of both Nrf2 and Srx sensitized HT29 cells, leads to ROS overproduction and decreased cell viability. This indicates that in HT29 cells, Nrf2/Srx axis is a protective factor against AGP-induced oxidative stress. The inhibition of Nrf2/Srx signaling should be considered as a central target in drug-resistant colorectal cancer treatments.
Resumo:
Aims Elevated dynamic plantar pressures are a consistent finding in diabetes patients with peripheral neuropathy with implications for plantar foot ulceration. This meta-analysis aimed to compare the plantar pressures of diabetes patients that had peripheral neuropathy and those with neuropathy with active or previous foot ulcers. Methods Published articles were identified from Medline via OVID, CINAHL, SCOPUS, INFORMIT, Cochrane Central EMBASE via OVID and Web of Science via ISI Web of Knowledge bibliographic databases. Observational studies reporting barefoot dynamic plantar pressure in adults with diabetic peripheral neuropathy, where at least one group had a history of plantar foot ulcers were included. Interventional studies, shod plantar pressure studies and studies not published in English were excluded. Overall mean peak plantar pressure (MPP) and pressure time integral (PTI) were primary outcomes. The six secondary outcomes were MPP and PTI at the rear foot, mid foot and fore foot. The protocol of the meta-analysis was published with PROPSERO, (registration number CRD42013004310). Results Eight observational studies were included. Overall MPP and PTI were greater in diabetic peripheral neuropathy patients with foot ulceration compared to those without ulceration (standardised mean difference 0.551, 95% CI 0.290–0.811, p<0.001; and 0.762, 95% CI 0.303–1.221, p = 0.001, respectively). Sub-group analyses demonstrated no significant difference in MPP for those with neuropathy with active ulceration compared to those without ulcers. A significant difference in MPP was found for those with neuropathy with a past history of ulceration compared to those without ulcers; (0.467, 95% CI 0.181– 0.753, p = 0.001). Statistical heterogeneity between studies was moderate. Conclusions Plantar pressures appear to be significantly higher in patients with diabetic peripheral neuropathy with a history of foot ulceration compared to those with diabetic neuropathy without a history of ulceration. More homogenous data is needed to confirm these findings.
Resumo:
To discover quantitative trait loci for intraocular pressure, amajor risk factor for glaucoma and the only modifiable one,weperformed agenome-wide association studyonadiscoverycohort of2175individualsfromSydney, Australia. We found a novel association between intraocular pressure and a common variant at 7p21 near to GLCCI1 and ICA1. The findings in this region were confirmed through two UK replication cohorts totalling 4866 individuals (rs59072263, Pcombined = 1.10 × 10-8). A copy of the G allele at this SNP is associated with an increase in mean IOP of 0.45 mmHg (95%CI = 0.30-0.61 mmHg). These results lend support to the implication of vesicle trafficking and glucocorticoid inducibility pathways in the determination of intraocular pressure and in the pathogenesis of primary open-angle glaucoma.
Resumo:
Elevated blood pressure is a common, heritable cause of cardiovascular disease worldwide. To date, identification of common genetic variants influencing blood pressure has proven challenging. We tested 2.5 million genotyped and imputed SNPs for association with systolic and diastolic blood pressure in 34,433 subjects of European ancestry from the Global BPgen consortium and followed up findings with direct genotyping (N 71,225 European ancestry, N 12,889 Indian Asian ancestry) and in silico comparison (CHARGE consortium, N = 29,136). We identified association between systolic or diastolic blood pressure and common variants in eight regions near the CYP17A1 (P = 7 × 10 24), CYP1A2 (P = 1 × 10 23), FGF5 (P = 1 × 10 21), SH2B3 (P = 3 × 10 18), MTHFR (P = 2 × 10 13), c10orf107 (P = 1 × 10 9), ZNF652 (P = 5 × 10 9) and PLCD3 (P = 1 × 10 8) genes. All variants associated with continuous blood pressure were associated with dichotomous hypertension. These associations between common variants and blood pressure and hypertension offer mechanistic insights into the regulation of blood pressure and may point to novel targets for interventions to prevent cardiovascular disease.
Resumo:
Purpose To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. Methods The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00D and +6.00D. Measurements were taken over each contact lens and also before and after the CLs had been worn. Results The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p<0.001) but no significant difference was found between the two powers of CLs. Conclusions Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result didn’t change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.
Resumo:
Identification of vulnerable plaque pre-rupture is extremely important for patient risk stratification. The mechanism of plaque rupture is still not entirely clear, but it is thought to be a process involving multiple factors. From a biomechanical viewpoint, plaque rupture is usually seen as a structural failure when the plaque cannot resist the hemodynamic blood pressure and shear stress exerted on it. However, the cardiovascular system is naturally a cyclical hemodynamic environment, and myocardial infarction can be a symptomatically quiescent but potentially progressive process when plaque ruptures at stresses much lower than its strength. Therefore, fatigue accumulation is a possible mechanism for plaque rupture. In this study, a crack growth model was developed, and the previously-mentioned hypothesis was tested by conducting a comparative study between 18 symptomatic and 16 asymptomatic patients with carotid stenosis.
Resumo:
Young females with mild hallux valgus (HV) have been identified as having an increased risk of first ray deformation. Little is known, however, about the biomechanical changes that might contribute to this increased risk. The purpose of this study was to compare kinetics changes during walking for mild HV subjects with high-heel-height shoes. Twelve female subjects (six with mild HV and six controls) participated in this study with heel height varying from 0 cm (barefoot) to 4.5 cm. Compared to healthy controls, patients had significantly higher peak pressure on the big toe area during barefoot walking. When the heel height increased, loading was transferred to medial side of the forefoot, and the big toe area suffered more impact compared to barefoot in mild HV. This study also demonstrated that the center of pressure (COP) inclines to medial side alteration after high-heeled shoes wearing. These findings indicate that mild HV people should be discouraged from wearing high-heeled shoes.
Resumo:
Background: Coronary tortuosity (CT) is a common coronary angiographic finding. Whether CT leads to an apparent reduction in coronary pressure distal to the tortuous segment of the coronary artery is still unknown. The purpose of this study is to determine the impact of CT on coronary pressure distribution by numerical simulation. Methods: 21 idealized models were created to investigate the influence of coronary tortuosity angle (CTA) and coronary tortuosity number (CTN) on coronary pressure distribution. A 2D incompressible Newtonian flow was assumed and the computational simulation was performed using finite volume method. CTA of 30°, 60°, 90°, 120° and CTN of 0, 1, 2, 3, 4, 5 were discussed under both steady and pulsatile conditions, and the changes of outlet pressure and inlet velocity during the cardiac cycle were considered. Results: Coronary pressure distribution was affected both by CTA and CTN. We found that the pressure drop between the start and the end of the CT segment decreased with CTA, and the length of the CT segment also declined with CTA. An increase in CTN resulted in an increase in the pressure drop. Conclusions: Compared to no-CT, CT can results in more decrease of coronary blood pressure in dependence on the severity of tortuosity and severe CT may cause myocardial ischemia.
Resumo:
The primary objective of this paper is to study the use of medical image-based finite element (FE) modelling in subjectspecific midsole design and optimisation for heel pressure reduction using a midsole plug under the calcaneus area (UCA). Plugs with different relative dimensions to the size of the calcaneus of the subject have been incorporated in the heel region of the midsole. The FE foot model was validated by comparing the numerically predicted plantar pressure with biomechanical tests conducted on the same subject. For each UCA midsole plug design, the effect of material properties and plug thicknesses on the plantar pressure distribution and peak pressure level during the heel strike phase of normal walking was systematically studied. The results showed that the UCA midsole insert could effectively modify the pressure distribution, and its effect is directly associated with the ratio of the plug dimension to the size of the calcaneus bone of the subject. A medium hardness plug with a size of 95% of the calcaneus has achieved the best performance for relieving the peak pressure in comparison with the pressure level for a solid midsole without a plug, whereas a smaller plug with a size of 65% of the calcaneus insert with a very soft material showed minimum beneficial effect for the pressure relief.