316 resultados para Patient compliance
Resumo:
Average speed enforcement is a relatively new approach gaining popularity throughout Europe and Australia. This paper reviews the evidence regarding the impact of this approach on vehicle speeds, crashes rates and a number of additional road safety and public health outcomes. The economic and practical viability of the approach as a road safety countermeasure is also explored. A literature review, with an international scope, of both published and grey literature was conducted. There is a growing body of evidence to suggest a number of road safety benefits associated with average speed enforcement, including high rates of compliance with speed limits, reductions in average and 85th percentile speeds and reduced speed variability between vehicles. Moreover, the approach has been demonstrated to be particularly effective in reducing excessive speeding behaviour. Reductions in crash rates have also been reported in association with average speed enforcement, particularly in relation to fatal and serious injury crashes. In addition, the approach has been shown to improve traffic flow, reduce vehicle emissions and has also been associated with high levels of public acceptance. Average speed enforcement offers a greater network-wide approach to managing speeds that reduces the impact of time and distance halo effects associated with other automated speed enforcement approaches. Although comparatively expensive it represents a highly reliable approach to speed enforcement that produces considerable returns on investment through reduced social and economic costs associated with crashes.
Resumo:
In John Kallinicos Accountants Pty Ltd v Dundrenan Pty Ltd [2009] QDC 141 Irwin DCJ considered the nature of a party’s obligation under r 222 of the Uniform Civil Procedure Rules 1999 (Qld) (UCPR) to produce documents referred to in the parties’ pleadings, particulars or affidavits. The decision examined whether the approach in Belela Pty Ltd v Menzies Excavation Pty Ltd [2005] 2 QdR 230 in relation to disclosure of documents under UCPR r 214 also applied to production of documents under r 222.
Resumo:
Aim: To describe the positioning of patients managed in an intensive care unit (ICU); assess how frequently these patients were repositioned; and determine if any specific factors influenced how, why or when patients were repositioned in the ICU. Background: Alterations in body position of ICU patients are important for patient comfort and are believed to prevent and/or treat pressure ulcers, improve respiratory function and combat the adverse effects of immobility. There is a paucity of research on the positioning of critically ill patients in Saudi Arabian ICUs. Design and Methods: A prospective observational study was undertaken. Participant demographic data were collected as were clinical factors (i.e. ventilation status, primary diagnosis, co-morbidities and Ramsay sedation score) and organizational factors (i.e. time of day, type of mattress or beds used, nurse/patient ratio and the patient's position). Clinical and some organization data were recorded over a continuous 48 hour period. Result: Twenty-eight participants were recruited to the study. No participant was managed in either a flat or prone position. Obese participants were most likely to be managed in a supine position. The mean time between turns was two hours. There was no significant association between the mean time between turns and the recorded variables related to patients' demographic and organizational considerations. Conclusion: Results indicate that patient positioning in the ICU was a direct result of unit policy - it appeared that patients were not repositioned based upon evaluation of their clinical condition but rather according to a two-hour ICU timetable
Resumo:
Background: Critically ill patients are at high risk for pressure ulcer (PrU) development due to their high acuity and the invasive nature of the multiple interventions and therapies they receive. With reported incidence rates of PrU development in the adult critical care population as high as 56%, the identification of patients at high risk of PrU development is essential. This paper will explore the association between PrU development and risk factors. It will also explore PrU development and the use of risk assessment scales for critically ill patients in adult intensive care units. Method: A literature search from 2000 to 2012 using the CINHAL, Cochrane Library, EBSCOHost, Medline (via EBSCOHost), PubMed, ProQuest and Google Scholar databases was conducted. Key words used were: pressure ulcer/s; pressure sore/s; decubitus ulcer/s; bed sore/s; critical care; intensive care; critical illness; prevalence; incidence; prevention; management; risk factor; risk assessment scale. Results: Nineteen articles were included in this review; eight studies addressing PrU risk factors, eight studies addressing risk assessment scales and three studies overlapping both. Results from the studies reviewed identified 28 intrinsic and extrinsic risk factors which may lead to PrU development. Development of a risk factor prediction model in this patient population, although beneficial, appears problematic due to many issues such as diverse diagnoses and subsequent patient needs. Additionally, several risk assessment instruments have been developed for early screening of patients at higher risk of developing PrU in the ICU. No existing risk assessment scales are valid for identification high risk critically ill patient,with the majority of scales potentially over-predicting patients at risk for PrU development. Conclusion: Research studies to inform the risk factors for potential pressure ulcer development are inconsistent. Additionally, there is no consistent or clear evidence which demonstrates any scale to better or more effective than another when used to identify the patients at risk for PrU development. Furthermore robust research is needed to identify the risk factors and develop valid scales for measuring the risk of PrU development in ICU.
Resumo:
Norms regulate the behaviour of their subjects and define what is legal and what is illegal. Norms typically describe the conditions under which they are applicable and the normative effects as a results of their applications. On the other hand, process models specify how a business operation or service is to be carried out to achieve a desired outcome. Norms can have significant impact on how business operations are conducted and they can apply to the whole or part of a business process. For example, they may impose conditions on the different aspects of a process (e.g., perform tasks in a specific sequence (control-flow), at a specific time or within a certain time frame (temporal aspect), by specific people (resources)). We propose a framework that provides the formal semantics of the normative requirements for determining whether a business process complies with a normative document (where a normative document can be understood in a very broad sense, ranging from internal policies to best practice policies, to statutory acts). We also present a classification of normal requirements based on the notion of different types of obligations and the effects of violating these obligations.
Resumo:
The aim of this study is to investigate the compliance impact of price queries issued by a securities market operator to its participating firms. Market operators in Australia and New Zealand, such as the Australian Securities Exchange and the New Zealand Securities Exchange, have the regulatory power in their rules to issue queries to its market participants to explain unusual fluctuations in trading price or volume in the market. The operator will issue a price query where it believes that the market has not been fully informed as to price relevant information. Responsive regulation has informed much of the regulatory debate in securities laws in our region. We posit that price queries are one strategy that a market operator can use in communicating its enforcement expectations to its stakeholder. However, whilst responsive regulation informs regulatory choices, an alternate view seeks to explain why participants respond to these regulatory strategies, and we use disclosure behaviour after price queries to test compliance behaviour
Resumo:
Existing compliance management frameworks (CMFs) offer a multitude of compliance management capabilities that makes difficult for enterprises to decide on the suitability of a framework. Making a decision on the suitability requires a deep understanding of the functionalities of a framework. Gaining such an understanding is a difficult task which, in turn, requires specialised tools and methodologies for evaluation. Current compliance research lacks such tools and methodologies for evaluating CMFs. This paper reports a methodological evaluation of existing CMFs based on a pre-defined evaluation criteria. Our evaluation highlights what existing CMFs offer, and what they cannot. Also, it underpins various open questions and discusses the challenges in this direction.
Resumo:
In Walter v Buckeridge [No.5] [2012] WASC 495 Le Miere J considered an application by the defendants for special costs orders under the applicable legislation in Western Australia. Aspects of the decision may be of persuasive value in dealing with similar issues under Queensland legislation.
Resumo:
Background and purpose: The purpose of the work presented in this paper was to determine whether patient positioning and delivery errors could be detected using electronic portal images of intensity modulated radiotherapy (IMRT). Patients and methods: We carried out a series of controlled experiments delivering an IMRT beam to a humanoid phantom using both the dynamic and multiple static field method of delivery. The beams were imaged, the images calibrated to remove the IMRT fluence variation and then compared with calibrated images of the reference beams without any delivery or position errors. The first set of experiments involved translating the position of the phantom both laterally and in a superior/inferior direction a distance of 1, 2, 5 and 10 mm. The phantom was also rotated 1 and 28. For the second set of measurements the phantom position was kept fixed and delivery errors were introduced to the beam. The delivery errors took the form of leaf position and segment intensity errors. Results: The method was able to detect shifts in the phantom position of 1 mm, leaf position errors of 2 mm, and dosimetry errors of 10% on a single segment of a 15 segment IMRT step and shoot delivery (significantly less than 1% of the total dose). Conclusions: The results of this work have shown that the method of imaging the IMRT beam and calibrating the images to remove the intensity modulations could be a useful tool in verifying both the patient position and the delivery of the beam.
Resumo:
Purpose: The precise shape of the three-dimensional dose distributions created by intensity-modulated radiotherapy means that the verification of patient position and setup is crucial to the outcome of the treatment. In this paper, we investigate and compare the use of two different image calibration procedures that allow extraction of patient anatomy from measured electronic portal images of intensity-modulated treatment beams. Methods and Materials: Electronic portal images of the intensity-modulated treatment beam delivered using the dynamic multileaf collimator technique were acquired. The images were formed by measuring a series of frames or segments throughout the delivery of the beams. The frames were then summed to produce an integrated portal image of the delivered beam. Two different methods for calibrating the integrated image were investigated with the aim of removing the intensity modulations of the beam. The first involved a simple point-by-point division of the integrated image by a single calibration image of the intensity-modulated beam delivered to a homogeneous polymethyl methacrylate (PMMA) phantom. The second calibration method is known as the quadratic calibration method and required a series of calibration images of the intensity-modulated beam delivered to different thicknesses of homogeneous PMMA blocks. Measurements were made using two different detector systems: a Varian amorphous silicon flat-panel imager and a Theraview camera-based system. The methods were tested first using a contrast phantom before images were acquired of intensity-modulated radiotherapy treatment delivered to the prostate and pelvic nodes of cancer patients at the Royal Marsden Hospital. Results: The results indicate that the calibration methods can be used to remove the intensity modulations of the beam, making it possible to see the outlines of bony anatomy that could be used for patient position verification. This was shown for both posterior and lateral delivered fields. Conclusions: Very little difference between the two calibration methods was observed, so the simpler division method, requiring only the single extra calibration measurement and much simpler computation, was the favored method. This new method could provide a complementary tool to existing position verification methods, and it has the advantage that it is completely passive, requiring no further dose to the patient and using only the treatment fields.
Resumo:
We have taken a new method of calibrating portal images of IMRT beams and used this to measure patient set-up accuracy and delivery errors, such as leaf errors and segment intensity errors during treatment. A calibration technique was used to remove the intensity modulations from the images leaving equivalent open field images that show patient anatomy that can be used for verification of the patient position. The images of the treatment beam can also be used to verify the delivery of the beam in terms of multileaf collimator leaf position and dosimetric errors. A series of controlled experiments delivering an IMRT anterior beam to the head and neck of a humanoid phantom were undertaken. A 2mm translation in the position of the phantom could be detected. With intentional introduction of delivery errors into the beam this method allowed us to detect leaf positioning errors of 2mm and variation in monitor units of 1%. The method was then applied to the case of a patient who received IMRT treatment to the larynx and cervical nodes. The anterior IMRT beam was imaged during four fractions and the images calibrated and investigated for the characteristic signs of patient position error and delivery error that were shown in the control experiments. No significant errors were seen. The method of imaging the IMRT beam and calibrating the images to remove the intensity modulations can be a useful tool in verifying both the patient position and the delivery of the beam.