169 resultados para Intraocular-lens


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To examine the influence of short-term miniscleral contact lens wear on corneal shape, thickness and anterior surface aberrations. Methods Scheimpflug imaging was captured before, immediately following and 3 hours after a short period (3 hours) of miniscleral contact lens wear for 10 young (mean 27 ± 5 years), healthy participants. Natural diurnal variations were considered by measuring baseline diurnal changes obtained on a separate control day without contact lens wear. Results Small but significant anterior corneal flattening was observed immediately following lens removal (overall mean 0.02 ± 0.03 mm, p < 0.001) which returned to baseline levels three hours after lens removal. During the three hour recovery period significant corneal thinning (-13.4 ± 10.5 μm) and posterior surface flattening (0.03 ± 0.02 mm) were also observed (both p < 0.01). The magnitude of posterior corneal flattening during recovery correlated with the amount of corneal thinning (r = 0.69, p = 0.03). Central corneal clearance (maximum tear reservoir depth) was not associated with corneal swelling following lens removal (r = -0.24, p > 0.05). An increase in lower-order corneal astigmatism Z(2,2) was also observed following lens wear (mean -0.144 ± 0.075 μm, p = 0.02). Conclusions Flattening of the anterior corneal surface was observed immediately following lens wear, while ‘rebound’ thinning and flattening of the posterior surface was evident following the recovery period. Modern miniscleral contact lenses that vault the cornea may slightly influence corneal shape and power but do not induce clinically significant corneal oedema during short-term wear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Donald Ezekiel (known to all as ‘Don’) was born in Singapore on September 12, 1936, to a German mother and Iraqi father. His parents were Jewish refugees, who met in Batavia,1 married and alternately lived in Batavia and Singapore. The family established their primary residence in Singapore after Don’s older brother Eric (later to become a haematologist) was born in 1934. The Ezekiel family was forced to flee in 1941 when the Japanese bombed Singapore and were fortunate to obtain passage on a hospital ship to Perth. They returned to Singapore after the war but left again on their own accord in 1951 due to race riots. The Ezekiels sold up everything in Singapore and decided to settle in Perth...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We sought to determine the impact of optometric practice setting on contact lens prescribing by analysing annual survey data of lens fits collected between 2009 and 2013 from independent and national group practices throughout the United Kingdom. Compared to national group practices, independent practices fit contact lenses to older patients and more females. Independent practices also undertake a lower proportion of soft lens fits overall (and thus a higher proportion of rigid lens fits), soft toric lens fits and daily disposable lens fits. There is a higher proportion of soft extended wear and multifocal lens fits in independent practices. We conclude that contact lens fitting behaviour is influenced by optometric practice setting.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose:Race appears to be associated with myopiogenesis, with East Asians showing high myopia prevalence. Considering structural variations in the eye, it is possible that retinal shapes are different between races. The purpose of this study was to quantify and compare retinal shapes between racial groups using peripheral refraction (PR) and peripheral eye lengths (PEL). Methods:A Shin-Nippon SRW5000 autorefractor and a Haag-Streit Lenstar LS900 biometer measured PR and PEL, respectively, along horizontal (H) and vertical (V) fields out to ±35° in 5° steps in 29 Caucasian (CA), 16 South Asian (SA) and 23 East Asian (EA) young adults (spherical equivalent range +0.75D to –5.00D in all groups). Retinal vertex curvature Rv and asphericity Q were determined from two methods: a) PR (Dunne): The Gullstrand-Emsley eye was modified according to participant’s intraocular lengths and anterior cornea curvature. Ray-tracing was performed at each angle through the stop, altering cornea asphericity until peripheral astigmatism matched experimental measurements. Retinal curvature and hence retinal co-ordinate intersection with the chief ray were altered until sagittal refraction matched its measurement. b) PEL: Ray-tracing was performed at each angle through the anterior corneal centre of curvature of the Gullstrand-Emsley eye. Ignoring lens refraction, retinal co-ordinates relative to the fovea were determined from PEL and trigonometry. From sets of retinal co-ordinates, conic retinal shapes were fitted in terms of Rv and Q. Repeated-measures ANOVA were conducted on Rv and Q, and post hoc t-tests with Bonferroni correction were used to compare races. Results:In all racial groups both methods showed greater Rv for the horizontal than for the vertical meridian and greater Rv for myopes than emmetropes. Rv was greater in EA than in CA (P=0.02), with Rv for SA being intermediate and not significantly different from CA and EA. The PEL method provided larger Rv than the PR method: PEL: EA vs CA 87±13 vs 83±11 m-1 (H), 79±13 vs 72±14 m-1 (V); PR: EA vs CA 79±10 vs 67±10 m-1 (H), 71±17 vs 66±12 m-1 (V). Q did not vary significantly with race. Conclusions:Estimates of Rv, but not of Q, varied significantly with race. The greater Rv found in EA than in CA and the comparatively high prevalence rate of myopia in many Asian countries may be related.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper considers the epistemological life cycle of the camera lens in documentary practices. The 19th century industrial economies that manufactured and commercialised the camera lens have engendered political and economic contingencies on documentary practices to sustain a hegemonic and singular interpretive epistemology. Colonial documentary practices are considered from the viewpoint of manipulative hegemonic practices - all of which use the interpretive epistemology of the camera lens to capitalise a viewpoint which is singular and possesses the power to sustain its own status and economic privilege. I suggest that decolonising documentary practices can be nurtured in what Boaventura de Sousa Santos proposes as an 'ecology of knowledges' (Andreotti, Ahenakew, & Cooper 2011) - a way of including the epistemologies of cultures beyond the 'abyssal' (Santos), outside the limits of epistemological dominance. If an 'epistemicide' (Santos) of indigenous knowledges in the dominant limits has occurred then in an ecology of knowledges the limits become limitless and what were once invisible knowledges, come into their own ontological and epistemological being: as free agents and on their own terms. In an ecology of knowledges, ignorance and blindness may still exist but are not privileged. The decolonisation of documentary practices inevitably destabilises prevailing historicities and initiates ways for equal privilege to exist between multiple epistemologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new imaging methodology is described to visualise the post lens tear film (PLTF) during contact lens wear. A rotating-Scheimpflug camera in combination with sodium fluorescein allows evaluation of the PLTF for different contact lens modalities, including mini-scleral, rigid gas permeable (RGP) and soft contact lenses. This imaging technique provides an extension of the instrument’s current functionality. The potential advantages and limitations of the technique are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The aim was to assess the compatibility of different multipurpose solutions (MPSs) with one type of silicone hydrogel (SiH) contact lens by, assessing the changes in both ultraviolet (UV) and visible light transmissibility of the hydrogel lens caused by the MPSs. Methods The light transmittance from 200-700 nm were measured for the lotrafilcon B blister pack solution (BPS), six MPSs namely, ReNuMultiPlus Multi-Purpose Solution (Bausch and Lomb Inc., Rochester NY, USA.); Complete RevitaLens Multi-Purpose (Abbott Medical Optics Inc., Quarryvale Co. Dublin, Ireland); All In One Light (Sauflon Pharmaceuticals Ltd., Twickenham, England); SOLO-care AQUA™ (Ciba Vision Corporation Duluth, Georgia, USA.); Biomedics All-in-one solution (CooperVision, Hamble, UK); and HippiaMultiPlus All-in-one solution (Interojo Inc., Kyeonggi-do, Korea), and a lotrafilcon B SiH lens (before and after storage), using a spectrophotometer. Results The UV transmitted through the BPS and the MPS were similar (p >.05, for all), except for the HippiaMultiPlus which was lower (p < 0.001) by 19.8%. Mean transparency values were statistically (p<.001) significantly different between the BPS and the MPSs. All MP solution/SiH lens combinations resulted in relatively high UV transmittance values especially in the UVC spectrum, and significantly increased (p <.001) the visible light transmittance values of the SiH lens. Greater changes in transparency were observed in the ReNu/SiH lens (28.5%) and the Complete RevitaLens/SiH lens (24.9%) combinations. Conclusion The six MPSs showed significant variations in the transmitted UV and visible light. Similar to the BPS, all MPSs were equally transparent, but showed very poor UVA & UVB attenuation, except for the Hippia MultiPlus. The MPS/SiH lens combinations did not significantly affect the lens transparency but it significant increased the lens transmittance of UV radiation, after storage. Further in-vivo studies are needed to validate if this effect is constant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM To assess the effects of eye rubbing on corneal thickness (CT) and intraocular pressure (IOP) measurements obtained 0-30min after habitual eye rubbing in symptomatic patients. METHODS Measurements of IOP and CT were obtained at five locations (central, temporal, superior, nasal and inferior) before, and every 5min for 30min interval after 30s of eye rubbing, for 25 randomly selected eyes of 14 subjects with ocular allergy and 11 age-matched normals. Differences in measurements were calculated in each group [Baseline measurements minus measurements recorded at each time interval after eye rubbing (for IOP), and for each corneal location (for CT)] and comparison were then made between groups (allergic versus control) for differences in any observed effects. RESULTS Within groups, baseline mean IOPs in the allergic patient-group (14.2±3.0 mm Hg) and in the control group (13.1±1.9 mm Hg) were similar at all times, after eye rubbing (P >0.05, for all). The maximum reduction in IOP was 0.8 mm Hg in the control subjects and the maximum increase was also 0.8 mm Hg in the allergic subjects. Between groups (allergic versus control), the changes in IOP remained under 1 mm Hg at all times (P=0.2) after 30min of eye rubbing. Between 0 and 30min of CT measurements after eye rubbing, the mean central CT (CCT), inferior CT (ICT), superior CT (SCT), temporal CT (TCT) and nasal CT (NCT) did not vary significantly from baseline values in the control and allergic-subject groups (P>0.05, for both). Between both groups, changes in CT were similar at all locations (P>0.05) except for the TC which was minimally thinner by about 4.4 µm (P=0.001) in the allergic subjects than in the control subjects, 30min following 30s of eye rubbing. CONCLUSION IOP measured in allergic subjects after 30s of habitual eye rubbing was comparable with that obtained in normal subjects at all times between 0 and 30min. Although, CT in the allergic subjects were similar to those of the control subjects at all times, it varied between +10 and -7.5 µm following eye rubbing, with the temporal cornea showing consistent reductions in thickness in the subjects with allergy. However, this reduction was minimal and was considered to not be clinically relevant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While Jonathan Silin's ideas have challenged early childhood educators to think seriously about the relationship between developmentalism and revisioning early education, they have done much more than this. They also challenge us to know who we are and how our identities might be enacted in our teacher-selves, whether in the classroom with young children, teacher education students or engaging professionally with teachers. In doing so he shows how to resist injustice and unmasks ways in which institutions function in society to marginalise and exclude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We sought to evaluate central corneal thickness (CCT), corneal endothelial cell density (ECD) and intraocular pressure (IOP) in patients with type 2 diabetes mellitus (DM) and to associate potential differences with diabetes duration and treatment modality in a prospective, randomized study. We measured ECD, CCT and IOP of 125 patients with type 2 DM (mean age 57.1¡11.5 years) and compared them with 90 age-matched controls. Measured parameters were analyzed for association with diabetes duration and glucose control modalities (insulin injection or oral medication) while controlling for age. In the diabetic group, the mean ECD (2511¡252 cells/mm2), mean CCT (539.7¡33.6 mm) and mean IOP (18.3¡2.5 mmHg) varied significantly from those the control group [ECD: 2713¡132 cells/mm2 (P,0.0001), CCT: 525.0¡45.3 mm (P50.003) and IOP: 16.7¡1.8 mmHg (P,0.0001)]. ECD was significantly reduced by about 32 cell/mm2 for diabetics with duration of .10 years when compared with those with duration of ,10 years (P,0.05). CCT was thicker and IOP was higher for diabetics with duration of .10 years than those with duration of ,10 years (P.0.05). None of the measured parameters was significantly associated with diabetes duration and treatment modality (P.0.05). In conclusion, subjects with type 2 DM exhibit significant changes in ECD, IOP and CCT, which, however, are not correlated with disease duration or if the patients receive on insulin injection or oral medications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Changes to the redox status of biological systems have been implicated in the pathogenesis of a wide variety of disorders including cancer, Ischemia-reperfusion (I/R) injury and neurodegeneration. In times of metabolic stress e.g. ischaemia/reperfusion, reactive oxygen species (ROS) production overwhelms the intrinsic antioxidant capacity of the cell, damaging vital cellular components. The ability to quantify ROS changes in vivo, is therefore essential to understanding their biological role. Here we evaluate the suitability of a novel reversible profluorescent probe containing a redox-sensitive nitroxide moiety (methyl ester tetraethylrhodamine nitroxide, ME-TRN), as an in vivo, real-time reporter of retinal oxidative status. The reversible nature of the probe's response offers the unique advantage of being able to monitor redox changes in both oxidizing and reducing directions in real time. After intravitreal administration of the ME-TRN probe, we induced ROS production in rat retina using an established model of complete, acute retinal ischaemia followed by reperfusion. After restoration of blood flow, retinas were imaged using a Micron III rodent fundus fluorescence imaging system, to quantify the redox-response of the probe. Fluorescent intensity declined during the first 60 min of reperfusion. The ROS-induced change in probe fluorescence was ameliorated with the retinal antioxidant, lutein. Fluorescence intensity in non-Ischemia eyes did not change significantly. This new probe and imaging technology provide a reversible and real-time response to oxidative changes and may allow the in vivo testing of antioxidant therapies of potential benefit to a range of diseases linked to oxidative stress

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Early Childhood Education (ECE) has a long history of building foundations for children to achieve their full potential, enabling parents to participate in the economy while children are cared for, addressing poverty and disadvantage, and building individual, community and societal resources. In so doing, ECE has developed a set of cultural practices and ways of knowing that shape the field and the people who work within it. ECE, consequently, is frequently described as unique and special (Moss, 2006; Penn, 2011). This works to define and distinguish the field while, simultaneously, insulating it from other contexts, professions, and ideas. Recognising this dualism illuminates some of the risks and challenges of operating in an insular and isolated fashion. In the 21st century, there are new challenges for children, families and societies to which ECE must respond if it is to continue to be relevant. One major issue is how ECE contributes to transition towards more sustainable ways of living. Addressing this contemporary social problem is one from which Early Childhood teacher education has been largely absent (Davis & Elliott, 2014), despite the well recognised but often ignored role of education in contributing to sustainability. Because of its complexity, sustainability is sometimes referred to as a ‘wicked problem’ (Rittel & Webber, 1973; Australian Public Service Commission, 2007) requiring alternatives to ‘business as usual’ problem solving approaches. In this chapter, we propose that addressing such problems alongside disciplines other than Education enables the Early Childhood profession to have its eyes opened to new ways of thinking about our work, potentially liberating us from the limitations of our “unique” and idiosyncratic professional cultures. In our chapter, we focus on understandings of culture and diversity, looking to broaden these by exploring the different ‘cultures’ of the specialist fields of ECE and Design (in this project, we worked with students studying Architecture, Industrial Design, Landscape Architecture and Interior Design). We define culture not as it is typically represented, i.e. in relation to ideas and customs of particular ethnic and language groups, but to the ideas and practices of people working in different disciplines and professions. We assert that different specialisms have their own ‘cultural’ practices. Further, we propose that this kind of theoretical work helps us to reconsider ways in which ECE might be reframed and broadened to meet new challenges such as sustainability and as yet unknown future challenges and possibilities. We explore these matters by turning to preservice Early Childhood teacher education (in Australia) as a context in which traditional views of culture and diversity might be reconstructed. We are looking to push our specialist knowledge boundaries and to extend both preservice teachers and academics beyond their comfort zones by engaging in innovative interdisciplinary learning and teaching. We describe a case study of preservice Early Childhood teachers and designers working in collaborative teams, intersecting with a ‘real-world’ business partner. The joint learning task was the design of an early learning centre based on sustainable design principles and in which early Education for Sustainability (EfS) would be embedded Data were collected via focus group and individual interviews with students in ECE and Design. Our findings suggest that interdisciplinary teaching and learning holds considerable potential in dismantling taken-for-granted cultural practices, such that professional roles and identities might be reimagined and reconfigured. We conclude the chapter with provocations challenging the ways in which culture and diversity in the field of ECE might be reconsidered within teacher education.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To discover quantitative trait loci for intraocular pressure, amajor risk factor for glaucoma and the only modifiable one,weperformed agenome-wide association studyonadiscoverycohort of2175individualsfromSydney, Australia. We found a novel association between intraocular pressure and a common variant at 7p21 near to GLCCI1 and ICA1. The findings in this region were confirmed through two UK replication cohorts totalling 4866 individuals (rs59072263, Pcombined = 1.10 × 10-8). A copy of the G allele at this SNP is associated with an increase in mean IOP of 0.45 mmHg (95%CI = 0.30-0.61 mmHg). These results lend support to the implication of vesicle trafficking and glucocorticoid inducibility pathways in the determination of intraocular pressure and in the pathogenesis of primary open-angle glaucoma.