285 resultados para Feeding frequency


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background & Aims: Inadequate feeding assistance and mealtime interruptions during hospitalisation may contribute to malnutrition and poor nutritional intake in older people. This study aimed to implement and compare three interventions designed to specifically address mealtime barriers and improve energy intakes of medical inpatients aged ≥65 years. Methods: Pre-post study compared three mealtime assistance interventions: PM: Protected Mealtimes with multidisciplinary education; AIN: additional assistant-in-nursing (AIN) with dedicated meal role; PM+AIN: combined intervention. Dietary intake of 254 patients (pre: n=115, post: n=141; mean age 80±8) was visually estimated on a single day in the first week of hospitalisation and compared with estimated energy requirements. Assistance activities were observed and recorded. Results: Mealtime assistance levels significantly increased in all interventions (p<0.01). Post-intervention participants were more likely to achieve adequate energy intake (OR=3.4, p=0.01), with no difference noted between interventions (p=0.29). Patients with cognitive impairment or feeding dependency appeared to gain substantial benefit from mealtime assistance interventions. Conclusions: Protected Mealtimes and additional AIN assistance (implemented alone or in combination) may produce modest improvements in nutritional intake. Targeted feeding assistance for certain patient groups holds promise; however, alternative strategies are required to address the complex problem of malnutrition in this population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Geminivirus infectivity is thought to depend on interactions between the virus replication-associated proteins Rep or RepA and host retinoblastoma-related proteins (pRBR), which control cell-cycle progression. It was determined that the substitution of two amino acids in the Maize streak virus (MSV) RepA pRBR-interaction motif (LLCNE to LLCLK) abolished detectable RepA-pRBR interaction in yeast without abolishing infectivity in maize. Although the mutant virus was infectious in maize, it induced less severe symptoms than the wild-type virus. Sequence analysis of progeny viral DNA isolated from infected maize enabled detection of a high-frequency single-nucleotide reversion of C(601)A in the 3 nt mutated sequence of the Rep gene. Although it did not restore RepA-pRBR interaction in yeast, sequence-specific PCR showed that, in five out of eight plants, the C(601)A reversion appeared by day 10 post-inoculation. In all plants, the C(601)A revertant eventually completely replaced the original mutant population, indicating a high selection pressure for the single-nucleotide reversion. Apart from potentially revealing an alternative or possibly additional function for the stretch of DNA that encodes the apparently non-essential pRBR-interaction motif of MSV Rep, the consistent emergence and eventual dominance of the C(601)A revertant population might provide a useful tool for investigating aspects of MSV biology, such as replication, mutation and evolution rates, and complex population phenomena, such as competition between quasispecies and population turnover. © 2005 SGM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Undernutrition, weight loss and dehydration are major clinical issues for people with dementia in residential care, with excessive weight loss contributing to increased risk of frailty, immobility, illness and premature morbidity. This paper discusses a nutritional knowledge and attitudes survey conducted as part of a larger project focused on improving nutritional intake of people with dementia within a residential care facility in Brisbane, Australia. Aims The specific aims of the survey were to identify (i) knowledge of the nutritional needs of aged care facility residents; (ii) mealtime practices; and (iii) attitudes towards mealtime practices and organisation. Methods A survey based on those used in other healthcare settings was completed by 76 staff members. The survey included questions about nutritional knowledge, opinions of the food service, frequency of feeding assistance provided and feeding assessment practices. Results Nutritional knowledge scores ranged from 1 to 9 of a possible 10, with a mean score of 4.67. While 76% of respondents correctly identified risk factors associated with malnutrition in nursing home residents, only 38% of participants correctly identified the need for increased protein and energy in residents with pressure ulcers, and just 15% exhibited correct knowledge of fluid requirements. Further, while nutritional assessment was considered an important part of practice by 83% of respondents, just 53% indicated that they actually carried out such assessments. Identified barriers to promoting optimal nutrition included insufficient time to observe residents (56%); being unaware of residents' feeding issues (46%); poor knowledge of nutritional assessments (44%); and unappetising appearance of food served (57%). Conclusion An important step towards improving health and quality of life for residents of aged care facilities would be to enhance staff nutritional awareness and assessment skills. This should be carried out through increased attention to both preservice curricula and on-the-job training. Implications for practice The residential facility staff surveyed demonstrated low levels of nutrition knowledge, which reflects findings from the international literature. This has implications for the provision of responsive care to residents of these facilities and should be explored further.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The well-established under-frequency load shedding (UFLS) is deemed to be the last of effective remedial measures against a severe frequency decline of a power system. With the ever-increasing size of power systems and the extensive penetration of distributed generators (DGs) in power systems, the problem of developing an optimal UFLS strategy is facing some new challenges. Given this background, an optimal UFLS strategy for a distribution system with DGs and load static characteristics taken into consideration is developed. Based on the frequency and the rate of change of frequency, the presented strategy consists of several basic rounds and a special round. In the basic round, the frequency emergency can be alleviated by quickly shedding some loads. In the special round, the frequency security can be maintained, and the operating parameters of the distribution system can be optimized by adjusting the output powers of DGs and some loads. The modified IEEE 37-node test feeder is employed to demonstrate the essential features of the developed optimal UFLS strategy in the MATLAB/SIMULINK environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A general electrical model of a piezoelectric transducer for ultrasound applications consists of a capacitor in parallel with RLC legs. A high power voltage source converter can however generate significant voltage stress across the transducer that creates high leakage currents. One solution is to reduce the voltage stress across the piezoelectric transducer by using an LC filter, however a main drawback is changing the piezoelectric resonant frequency and its characteristics. Thereby it reduces the efficiency of energy conversion through the transducer. This paper proposes that a high frequency current source converter is a suitable topology to drive high power piezoelectric transducers efficiently.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim This cross-sectional study explores associations between migrant Indian mothers’ use of controlling feeding practices (pressure to eat, restriction and monitoring) and their concerns and perceptions regarding their children’s weight and picky eating behaviour. Methods Two hundred and thirty mothers with children aged 1-5 years, residing in Australia for 1-8 years, participated by completing a self-reported questionnaire. Results Perceptions and concerns regarding children’s weight were not associated with any of the controlling feeding practices. A positive association was noted between pressure feeding and perceptions of pickiness after adjusting for covariates: children’s age, gender and weight-for-age Z-score. Girls, older children, and children with higher weight-for-age z scores were pressure fed to a greater extent. Conclusions This study supports the generalisation of findings from Caucasian literature that pressure feeding and perceptions of pickiness are positively related.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reasons for performing study: Many domestic horses and ponies are sedentary and obese due to confinement to small paddocks and stables and a diet of infrequent, high-energy rations. Severe health consequences can be associated with this altered lifestyle. Objectives: The aims of this study were to investigate the ability of horses to learn to use a dynamic feeder system and determine the movement and behavioural responses of horses to the novel system. Methods: A dynamic feed station was developed to encourage horses to exercise in order to access ad libitum hay. Five pairs of horses (n = 10) were studied using a randomised crossover design with each pair studied in a control paddock containing a standard hay feeder and an experimental paddock containing the novel hay feeder. Horse movement was monitored by a global positioning system (GPS) and horses observed and their ability to learn to use the system and the behavioural responses to its use assessed. Results: With initial human intervention all horses used the novel feeder within 1 h. Some aggressive behaviour was observed between horses not well matched in dominance behaviour. The median distance walked by the horses was less (P = 0.002) during a 4 h period (117 [57–185] m) in the control paddock than in the experimental paddock (630 [509–719] m). Conclusions: The use of an automated feeding system promotes increased activity levels in horses housed in small paddocks, compared with a stationary feeder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reasons for performing study: The distance travelled by Australian feral horses in an unrestricted environment has not previously been determined. It is important to investigate horse movement in wilderness environments to establish baseline data against which the movement of domestically managed horses and wild equids can be compared. Objectives: To determine the travel dynamics of 2 groups of feral horses in unrestricted but different wilderness environments. Methods: Twelve feral horses living in 2 wilderness environments (2000 vs. 20,000 km2) in outback Australia were tracked for 6.5 consecutive days using custom designed, collar mounted global positioning systems (GPS). Collars were attached after darting and immobilising the horses. The collars were recovered after a minimum of 6.5 days by re-darting the horses. Average daily distance travelled was calculated. Range use and watering patterns of horses were analysed by viewing GPS tracks overlaid on satellite photographs of the study area. Results: Average distance travelled was 15.9 ± 1.9 km/day (range 8.1–28.3 km/day). Horses were recorded up to 55 km from their watering points and some horses walked for 12 h to water from feeding grounds. Mean watering frequency was 2.67 days (range 1–4 days). Central Australian horses watered less frequently and showed a different range use compared to horses from central Queensland. Central Australian horses walked for long distances in direct lines to patchy food sources whereas central Queensland horses were able to graze close to water sources and moved in a more or less circular pattern around the central water source. Conclusions: The distances travelled by feral horses were far greater than those previously observed for managed domestic horses and other species of equid. Feral horses are able to travel long distances and withstand long periods without water, allowing them to survive in semi-arid conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To investigate the frequency characteristics of the ground reaction force (GRF) recorded throughout the eccentric Achilles tendon rehabilitation programme described by Alfredson. Design: Controlled laboratory study, longitudinal. Methods: Nine healthy adult males performed six sets (15 repetitions per set) of eccentric ankle exercise. Ground reaction force was recorded throughout the exercise protocol. For each exercise repetition the frequency power spectrum of the resultant ground reaction force was calculated and normalised to total power. The magnitude of peak relative power within the 8-12 Hz bandwidth and the frequency at which this peak occurred was determined. Results: The magnitude of peak relative power within the 8-12 Hz bandwidth increased with each successive exercise set and following the 4th set (60 repetitions) of exercise the frequency at which peak relative power occurred shifted from 9 to 10 Hz. Conclusions: The increase in magnitude and frequency of ground reaction force vibrations with an increasing number of exercise repetitions is likely connected to changes in muscle activation with fatigue and tendon conditioning. This research illustrates the potential for the number of exercise repetitions performed to influence the tendons' mechanical environment, with implications for tendon remodelling and the clinical efficacy of eccentric rehabilitation programmes for Achilles tendinopathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Eccentric exercise (EE) is a commonly used treatment for Achilles tendinopathy. While vibrations in the 8–12 Hz frequency range generated during eccentric muscle actions have been put forward as a potential mechanism for the beneficial effect of EE, optimal loading parameters required to expedite recovery are currently unknown. Alfredson's original protocol employed 90 repetitions of eccentric loading, however abbreviated protocols consisting of fewer repetitions (typically 45) have been developed, albeit with less beneficial effect. Given that 8–12 Hz vibrations generated during isometric muscle actions have been previously shown to increase with fatigue, this research evaluated the effect of exercise repetition on motor output vibrations generated during EE by investigating the frequency characteristics of ground reaction force (GRF) recorded throughout the 90 repetitions of Alfredson's protocol. Methods: Nine healthy adult males performed six sets (15 repetitions per set) of eccentric ankle exercise. GRF was recorded at a frequency of 1000 Hz throughout the exercise protocol. The frequency power spectrum of the resultant GRF was calculated and normalized to total power. Relative spectral power was summed over 1 Hz widows within the frequency rage 7.5–11.5 Hz. The effect of each additional exercise set (15 repetitions) on the relative power within each widow was investigated using a general linear modelling approach. Results: The magnitude of peak relative power within the 7.5–11.5 Hz bandwidth increased across the six exercise sets from 0.03 in exercise set one to 0.12 in exercise set six (P < 0.05). Following the 4th set of exercise the frequency at which peak relative power occurred shifted from 9 to 10 Hz. Discussion: This study has demonstrated that successive repetitions of eccentric loading over six exercise sets results in an increase in the amplitude of motor output vibrations in the 7.5–11.5 Hz bandwidth, with an increase in the frequency of these vibrations occurring after the 4th set (60th repetition). These findings are consistent with findings from previous studies of muscle fatigue. Assuming that the magnitude and frequency of these vibrations represent important stimuli for tendon remodelling as hypothesized within the literature, the findings of this study question the role of abbreviated EE protocols and raise the question; can EE protocols for tendinopathy be optimized by performing eccentric loading to fatigue?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Previous research has demonstrated that ground reaction force (GRF) recorded during eccentric ankle exercise is characterised by greater power in the 8-12Hz bandwidth when compared to that recorded during concentric ankle exercise. Subsequently, it was suggested that vibrations in this bandwidth may underpin the beneficial effect of eccentric loading in tendon repair. However, this observation has been made only in individuals without Achilles tendinopathy. This research compared the force frequency characteristics of eccentric and concentric exercises in individuals with and without Achilles tendinopathy., Methods Eleven male adults with unilateral mid-portion Achilles tendinopathy and nine control male adults without tendinopathy participated in the research. Kinematics and GRF were recorded while the participants performed a common eccentric rehabilitation exercise protocol and a concentric equivalent. Ankle joint kinematics and the frequency power spectrum of the resultant GRF were calculated. Results Eccentric exercise was characterised by a significantly greater proportion of spectral power between 4.5 and 11.5Hz when compared to concentric exercise. There were no significant differences between limbs in the force frequency characteristics of concentric exercise. Eccentric exercise, in contrast, was defined by a shift in the power spectrum of the symptomatic limb, resulting in a second spectral peak at 9Hz, rather than 10Hz in the control limb. Conclusions Compared to healthy tendon, Achilles tendinopathy was characterised by lower frequency vibrations during eccentric rehabilitation exercises. This finding may be associated with changes in neuromuscular activation and tendon stiffness which have been shown to occur with tendinopathy and provides a possible rationale for the previous observation of a different biochemical response to eccentric exercise in healthy and injured Achilles tendons., (C)2012The American College of Sports Medicine

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Use a randomised controlled trial (RCT) to evaluate outcomes of a universal intervention to promote protective feeding practices, which commenced in infancy and aimed to prevent childhood obesity Subjects and Methods The NOURISH RCT enrolled 698 first-time mothers (mean age 30.1 years, SD=5.3) with healthy term infants (51% female) aged 4.3 (SD=1.0) months at baseline. Mothers were randomly allocated to self-directed access to usual care or to attend two 6-session interactive group education modules that provided anticipatory guidance on early feeding practices. Outcomes were assessed six months after completion of the second information module, 20 months from baseline and when the children were two years old. Maternal feeding practices were self-reported using validated questionnaires and study-developed items. Study-measured child height and weight were used to calculate BMI Z-score. Results Retention at follow-up was 78%. Mothers in the intervention group reported using responsive feeding more frequently on 6/9 subscales and 8/8 items (Ps ≤.03) and overall less ‘controlling feeding practices’ (P<.001). They also more frequently used feeding practices (3/4 items; Ps <.01) likely to enhance food acceptance. No statistically significant differences were noted in anthropometric outcomes (BMI Z-score: P=.11), nor in prevalence of overweight/obesity (control 17.9% vs. intervention 13.8%, P=.23). Conclusions Evaluation of NOURISH at child age two years found that anticipatory guidance on complementary feeding, tailored to developmental stage, increased use by first-time mothers of 'protective' feeding practices that potentially support the development of healthy eating and growth patterns in young children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability of a piezoelectric transducer in energy conversion is rapidly expanding in several applications. Some of the industrial applications for which a high power ultrasound transducer can be used are surface cleaning, water treatment, plastic welding and food sterilization. Also, a high power ultrasound transducer plays a great role in biomedical applications such as diagnostic and therapeutic applications. An ultrasound transducer is usually applied to convert electrical energy to mechanical energy and vice versa. In some high power ultrasound system, ultrasound transducers are applied as a transmitter, as a receiver or both. As a transmitter, it converts electrical energy to mechanical energy while a receiver converts mechanical energy to electrical energy as a sensor for control system. Once a piezoelectric transducer is excited by electrical signal, piezoelectric material starts to vibrate and generates ultrasound waves. A portion of the ultrasound waves which passes through the medium will be sensed by the receiver and converted to electrical energy. To drive an ultrasound transducer, an excitation signal should be properly designed otherwise undesired signal (low quality) can deteriorate the performance of the transducer (energy conversion) and increase power consumption in the system. For instance, some portion of generated power may be delivered in unwanted frequency which is not acceptable for some applications especially for biomedical applications. To achieve better performance of the transducer, along with the quality of the excitation signal, the characteristics of the high power ultrasound transducer should be taken into consideration as well. In this regard, several simulation and experimental tests are carried out in this research to model high power ultrasound transducers and systems. During these experiments, high power ultrasound transducers are excited by several excitation signals with different amplitudes and frequencies, using a network analyser, a signal generator, a high power amplifier and a multilevel converter. Also, to analyse the behaviour of the ultrasound system, the voltage ratio of the system is measured in different tests. The voltage across transmitter is measured as an input voltage then divided by the output voltage which is measured across receiver. The results of the transducer characteristics and the ultrasound system behaviour are discussed in chapter 4 and 5 of this thesis. Each piezoelectric transducer has several resonance frequencies in which its impedance has lower magnitude as compared to non-resonance frequencies. Among these resonance frequencies, just at one of those frequencies, the magnitude of the impedance is minimum. This resonance frequency is known as the main resonance frequency of the transducer. To attain higher efficiency and deliver more power to the ultrasound system, the transducer is usually excited at the main resonance frequency. Therefore, it is important to find out this frequency and other resonance frequencies. Hereof, a frequency detection method is proposed in this research which is discussed in chapter 2. An extended electrical model of the ultrasound transducer with multiple resonance frequencies consists of several RLC legs in parallel with a capacitor. Each RLC leg represents one of the resonance frequencies of the ultrasound transducer. At resonance frequency the inductor reactance and capacitor reactance cancel out each other and the resistor of this leg represents power conversion of the system at that frequency. This concept is shown in simulation and test results presented in chapter 4. To excite a high power ultrasound transducer, a high power signal is required. Multilevel converters are usually applied to generate a high power signal but the drawback of this signal is low quality in comparison with a sinusoidal signal. In some applications like ultrasound, it is extensively important to generate a high quality signal. Several control and modulation techniques are introduced in different papers to control the output voltage of the multilevel converters. One of those techniques is harmonic elimination technique. In this technique, switching angles are chosen in such way to reduce harmonic contents in the output side. It is undeniable that increasing the number of the switching angles results in more harmonic reduction. But to have more switching angles, more output voltage levels are required which increase the number of components and cost of the converter. To improve the quality of the output voltage signal with no more components, a new harmonic elimination technique is proposed in this research. Based on this new technique, more variables (DC voltage levels and switching angles) are chosen to eliminate more low order harmonics compared to conventional harmonic elimination techniques. In conventional harmonic elimination method, DC voltage levels are same and only switching angles are calculated to eliminate harmonics. Therefore, the number of eliminated harmonic is limited by the number of switching cycles. In the proposed modulation technique, the switching angles and the DC voltage levels are calculated off-line to eliminate more harmonics. Therefore, the DC voltage levels are not equal and should be regulated. To achieve this aim, a DC/DC converter is applied to adjust the DC link voltages with several capacitors. The effect of the new harmonic elimination technique on the output quality of several single phase multilevel converters is explained in chapter 3 and 6 of this thesis. According to the electrical model of high power ultrasound transducer, this device can be modelled as parallel combinations of RLC legs with a main capacitor. The impedance diagram of the transducer in frequency domain shows it has capacitive characteristics in almost all frequencies. Therefore, using a voltage source converter to drive a high power ultrasound transducer can create significant leakage current through the transducer. It happens due to significant voltage stress (dv/dt) across the transducer. To remedy this problem, LC filters are applied in some applications. For some applications such as ultrasound, using a LC filter can deteriorate the performance of the transducer by changing its characteristics and displacing the resonance frequency of the transducer. For such a case a current source converter could be a suitable choice to overcome this problem. In this regard, a current source converter is implemented and applied to excite the high power ultrasound transducer. To control the output current and voltage, a hysteresis control and unipolar modulation are used respectively. The results of this test are explained in chapter 7.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis investigated the viability of using Frequency Response Functions in combination with Artificial Neural Network technique in damage assessment of building structures. The proposed approach can help overcome some of limitations associated with previously developed vibration based methods and assist in delivering more accurate and robust damage identification results. Excellent results are obtained for damage identification of the case studies proving that the proposed approach has been developed successfully.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modernized GPS and GLONASS, together with new GNSS systems, BeiDou and Galileo, offer code and phase ranging signals in three or more carriers. Traditionally, dual-frequency code and/or phase GPS measurements are linearly combined to eliminate effects of ionosphere delays in various positioning and analysis. This typical treatment method has imitations in processing signals at three or more frequencies from more than one system and can be hardly adapted itself to cope with the booming of various receivers with a broad variety of singles. In this contribution, a generalized-positioning model that the navigation system independent and the carrier number unrelated is promoted, which is suitable for both single- and multi-sites data processing. For the synchronization of different signals, uncalibrated signal delays (USD) are more generally defined to compensate the signal specific offsets in code and phase signals respectively. In addition, the ionospheric delays are included in the parameterization with an elaborate consideration. Based on the analysis of the algebraic structures, this generalized-positioning model is further refined with a set of proper constrains to regularize the datum deficiency of the observation equation system. With this new model, uncalibrated signal delays (USD) and ionospheric delays are derived for both GPS and BeiDou with a large dada set. Numerical results demonstrate that, with a limited number of stations, the uncalibrated code delays (UCD) are determinate to a precision of about 0.1 ns for GPS and 0.4 ns for BeiDou signals, while the uncalibrated phase delays (UPD) for L1 and L2 are generated with 37 stations evenly distributed in China for GPS with a consistency of about 0.3 cycle. Extra experiments concerning the performance of this novel model in point positioning with mixed-frequencies of mixed-constellations is analyzed, in which the USD parameters are fixed with our generated values. The results are evaluated in terms of both positioning accuracy and convergence time.