231 resultados para Eye-Tracking


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Over 40% of the permanent population of Norfolk Island possesses a unique genetic admixture dating to Pitcairn Island in the late 18 th century, with descendents having varying degrees of combined Polynesian and European ancestry. We conducted a population-based study to determine the prevalence and causes of blindness and low vision on Norfolk Island. Methods: All permanent residents of Norfolk Island aged ≥ 15 years were invited to participate. Participants completed a structured questionnaire/interview and underwent a comprehensive ophthalmic examination including slit-lamp biomicroscopy. Results: We recruited 781 people aged ≥ 15, equal to 62% of the permanent population, 44% of whom could trace their ancestry to Pitcairn Island. No one was bilaterally blind. Prevalence of unilateral blindness (visual acuity [VA] < 6/60) in those aged ≥ 40 was 1.5%. Blindness was more common in females (P=0.049) and less common in people with Pitcairn Island ancestry (P<0.001). The most common causes of unilateral blindness were age-related macular degeneration (AMD), amblyopia, and glaucoma. Five people had low vision (Best-Corrected VA < 6/18 in better eye), with 4 (80%) due to AMD. People with Pitcairn Island ancestry had a lower prevalence of AMD (P<0.001) but a similar prevalence of glaucoma to those without Pitcairn Island ancestry. Conclusions: The prevalence of blindness and visual impairment in this isolated Australian territory is low, especially amongst those with Pitcairn Island ancestry. AMD was the most common cause of unilateral blindness and low vision. The distribution of chronic ocular diseases on Norfolk Island is similar to mainland Australian estimates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Improving safety at rail level crossings is an important part of both road and rail safety strategies. While low in number, crashes between vehicles and trains at level crossings are catastrophic events typically involving multiple fatalities and serious injuries. Advances in driving assessment methods, such as the provision of on-road instrumented test vehicles with eye and head tracking, provide researchers with the opportunity to further understand driver behaviour at such crossings in ways not previously possible. This paper describes a study conducted to further understand the factors that shape driver behaviour at rail level crossings using instrumented vehicles. Twenty-two participants drove an On-Road Test Vehicle (ORTeV) on a predefined route in regional Victoria with a mix of both active (flashing lights with/without boom barriers) and passively controlled (stop, give way) crossings. Data collected included driving performance data, head checks, and interview data to capture driver strategies. The data from an integrated suite of methods demonstrated clearly how behaviour differs at active and passive level crossings, particularly for inexperienced drivers. For example, the head check data clearly show the reliance and expectancies of inexperienced drivers for active warnings even when approaching passively controlled crossings. These studies provide very novel and unique insights into how level crossing design and warnings shape driver behaviour.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 3-year longitudinal study Transforming Children’s Mathematical and Scientific Development integrates, through data modelling, a pedagogical approach focused on mathematical patterns and structural relationships with learning in science. As part of this study, a purposive sample of 21 highly able Grade 1 students was engaged in an innovative data modelling program. In the majority of students, representational development was observed. Their complex graphs depicting categorical and continuous data revealed a high level of structure and enabled identification of structural features critical to this development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cell migration is fundamental to many different physiological processes including embryonic development, inflammation and wound healing. Given the range and importance cell migration plays a number of assays have been developed to measure different aspects of cell migration. Here we describe two different methods to analyze cell migration. The first method analyzes the migration of fluorescently tagged cells using Boyden chambers and FACs and the second looks at migration properties using time-lapse microscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: GABA antagonists inhibit experimental myopia in chick and GABA receptors have been localized to chick sclera and the retinal pigment epithelium (RPE). The RPE and the choroid alter scleral DNA and glycosaminoglycan (GAG) content in vitro; opposite effects have been observed for tissues from myopic and hyperopic eyes. The aim was to determine the effect of GABAergic agents on the DNA and GAG content of chick scleral fibroblasts directly and in co-culture with ocular tissues from myopic and hyperopic chick eyes. Materials and Methods: Primary cultures of fibroblastic cells expressing vimentin and α-smooth muscle actin were established. GABAergic agents were added separately (i) to the culture medium of the scleral cells and (ii) to the culture medium of the scleral cells with the addition of posterior eye cup tissue (retina, RPE, retina + RPE, choroid + RPE) to cell culture inserts. Ocular tissues were obtained from chick eyes wearing + 15D (lens-induced hyperopia, LIH) or −15D lenses (lens-induced myopia, LIM) for three days (post-hatch day 5–8) (n = 12). GAG and DNA content of scleral fibroblasts were measured. Results: GABA agents had a small direct effect on scleral cell GAG and DNA content but a larger effect was measured when GABA agents were added to the culture medium with myopic and hyperopic RPE and choroid + RPE tissues. GABA agonists increased (p = 0.002) whereas antagonists decreased (p = 0.0004) DNA content of scleral cells; effects were opposite for scleral GAG content. GABA agents significantly altered the effect of both LIM and LIH tissues (p = 0.0005) compared to control; the effects were greater for LIM tissue versus LIH tissue co-culture (p = 0.0004). Conclusion: GABAergic agents affect the DNA and GAG content of scleral fibroblasts both directly and when co-cultured with ocular tissues. GABA antagonists that prevent myopia development in chick model could act via a scleral mechanism utilizing the RPE/choroid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Capacity of current and future high data rate wireless communications depend significantly on how well changes in the wireless channel are predicted and tracked. Generally, this can be estimated by transmitting known symbols. However, this increases overheads if the channel varies over time. Given today’s bandwidth demand and the increased necessity for mobile wireless devices, the contributions of this research are very significant. This study has developed a novel and efficient channel tracking algorithm that can recursively update the channel estimation for wireless broadband communications reducing overheads, therefore increasing the speed of wireless communication systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Foot ulcers are a leading cause of avoidable hospital admissions and lower extremity amputations. However, large clinical studies describing foot ulcer presentations in the ambulatory setting are limited. The aim of this descriptive observational paper is to report the characteristics of ambulatory foot ulcer patients managed across 13 of 17 Queensland Health & Hospital Services. Methods Data on all foot ulcer patients registered with a Queensland High Risk Foot Form (QHRFF) was collected at their first consult in 2012. Data is automatically extracted from each QHRFF into a Queensland high risk foot database. Descriptive statistics display age, sex, ulcer types and co-morbidities. Statewide clinical indicators of foot ulcer management are also reported. Results Overall, 2,034 people presented with a foot ulcer in 2012. Mean age was 63(±14) years and 67.8% were male. Co-morbidities included 85% had diabetes, 49.7% hypertension, 39.2% dyslipidaemia, 25.6% cardiovascular disease, 13.7% kidney disease and 12.2% smoking. Foot ulcer types included 51.6% neuropathic, 17.8% neuro-ischaemic, 7.2% ischaemic, 6.6% post-surgical and 16.8% other; whilst 31% were infected. Clinical indicator results revealed 98% had their wound categorised, 51% received non-removable offloading, median ulcer healing time was 6-weeks and 37% had ulcer recurrence. Conclusion This paper details the largest foot ulcer database reported in Australia. People presenting with foot ulcers appear predominantly older, male with several co-morbidities. Encouragingly it appears most patients are receiving best practice care. These results may be a factor in the significant reduction of Queensland diabetes foot-related hospitalisations and amputations recently reported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess intrasessional and intersessional repeatability of two commercial partial coherence interferometry instruments for measuring peripheral eye lengths and to investigate the agreement between the two instruments. Methods: Central and peripheral eye lengths were determined with the IOLMaster (Carl-Zeiss Meditec AG, Jena, Germany) and the Lenstar (Haag Streit, Bern, Switzerland) in seven adults. Measurements were performed out to 35° and 30° from fixation for horizontal and vertical visual fields, respectively, in 5° intervals. An external fixation target at optical infinity was used. At least four measurements were taken at each location for each instrument, and measurements were taken at two sessions. Results: The mean intrasessional SDs for the IOLMaster along both the horizontal and vertical visual fields were 0.04 ± 0.04 mm; corresponding results for the Lenstar were 0.02 ± 0.02 mm along both fields. The intersessional SDs for the IOLMaster for the horizontal and vertical visual fields were ±0.11 and ±0.08 mm, respectively; corresponding limits for the Lenstar were ±0.05 and ±0.04 mm. The intrasessional and intersessional variability increased away from fixation. The mean differences between the two instruments were 0.01 ± 0.07 mm and 0.02 ± 0.07 mm in the horizontal and vertical visual fields, but the lengths with the Lenstar became greater than those with the IOLMaster as axial length increased (rate of approximately 0.016 mm/mm). Conclusions: Both the IOLMaster and the Lenstar demonstrated good intrasessional and intersessional repeatability for peripheral eye length measurements, with the Lenstar showing better repeatability. The Lenstar would be expected to give a slightly greater range of eye lengths than the IOLMaster across the visual field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The eye rotation approach for measuring peripheral eye length leads to concern about whether the rotation influences results, such as through pressure exerted by eyelids or extra-ocular muscles. This study investigated whether this approach is valid. Methods Peripheral eye lengths were measured with a Lenstar LS 900 biometer for eye rotation and no-eye rotation conditions (head rotation for horizontal meridian and instrument rotation for vertical meridian). Measurements were made for 23 healthy young adults along the horizontal visual field (±30°) and, for a subset of eight participants along the vertical visual field (±25°). To investigate the influence of the duration of eye rotation, for six participants measurements were made at 0, 60, 120, 180 and 210 s after eye rotation to ±30° along horizontal and vertical visual fields. Results Peripheral eye lengths were not significantly different for the conditions along the vertical meridian (F1,7 = 0.16, p = 0.71). The peripheral eye lengths for the conditions were significantly different along the horizontal meridian (F1,22 = 4.85, p = 0.04), although not at individual positions (p ≥ 0.10) and were not important. There were no apparent differences between the emmetropic and myopic groups. There was no significant change in eye length at any position after maintaining position for 210 s. Conclusion Eye rotation and no-eye rotation conditions were similar for measuring peripheral eye lengths along horizontal and vertical visual field meridians at ±30° and ±25°, respectively. Either condition can be used to estimate retinal shape from peripheral eye lengths.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostics of rotating machinery has developed significantly in the last decades, and industrial applications are spreading in different sectors. Most applications are characterized by varying velocities of the shaft and in many cases transients are the most critical to monitor. In these variable speed conditions, fault symptoms are clearer in the angular/order domains than in the common time/frequency ones. In the past, this issue was often solved by synchronously sampling data by means of phase locked circuits governing the acquisition; however, thanks to the spread of cheap and powerful microprocessors, this procedure is nowadays rarer; sampling is usually performed at constant time intervals, and the conversion to the order domain is made by means of digital signal processing techniques. In the last decades different algorithms have been proposed for the extraction of an order spectrum from a signal sampled asynchronously with respect to the shaft rotational velocity; many of them (the so called computed order tracking family) use interpolation techniques to resample the signal at constant angular increments, followed by a common discrete Fourier transform to shift from the angular domain to the order domain. A less exploited family of techniques shifts directly from the time domain to the order spectrum, by means of modified Fourier transforms. This paper proposes a new transform, named velocity synchronous discrete Fourier transform, which takes advantage of the instantaneous velocity to improve the quality of its result, reaching performances that can challenge the computed order tracking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transmission path from the excitation to the measured vibration on the surface of a mechanical system introduces a distortion both in amplitude and in phase. Moreover, in variable speed conditions, the amplification/attenuation and the phase shift, due to the transfer function of the mechanical system, varies in time. This phenomenon reduces the effectiveness of the traditionally tachometer based order tracking, compromising the results of a discrete-random separation performed by a synchronous averaging. In this paper, for the first time, the extent of the distortion is identified both in the time domain and in the order spectrum of the signal, highlighting the consequences for the diagnostics of rotating machinery. A particular focus is given to gears, providing some indications on how to take advantage of the quantification of the disturbance to better tune the techniques developed for the compensation of the distortion. The full theoretical analysis is presented and the results are applied to an experimental case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the past decade, vision-based tracking systems have been successfully deployed in professional sports such as tennis and cricket for enhanced broadcast visualizations as well as aiding umpiring decisions. Despite the high-level of accuracy of the tracking systems and the sheer volume of spatiotemporal data they generate, the use of this high quality data for quantitative player performance and prediction has been lacking. In this paper, we present a method which predicts the location of a future shot based on the spatiotemporal parameters of the incoming shots (i.e. shot speed, location, angle and feet location) from such a vision system. Having the ability to accurately predict future short-term events has enormous implications in the area of automatic sports broadcasting in addition to coaching and commentary domains. Using Hawk-Eye data from the 2012 Australian Open Men's draw, we utilize a Dynamic Bayesian Network to model player behaviors and use an online model adaptation method to match the player's behavior to enhance shot predictability. To show the utility of our approach, we analyze the shot predictability of the top 3 players seeds in the tournament (Djokovic, Federer and Nadal) as they played the most amounts of games.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The integration of separate, yet complimentary, cortical pathways appears to play a role in visual perception and action when intercepting objects. The ventral system is responsible for object recognition and identification, while the dorsal system facilitates continuous regulation of action. This dual-system model implies that empirically manipulating different visual information sources during performance of an interceptive action might lead to the emergence of distinct gaze and movement pattern profiles. To test this idea, we recorded hand kinematics and eye movements of participants as they attempted to catch balls projected from a novel apparatus that synchronised or de-synchronised accompanying video images of a throwing action and ball trajectory. Results revealed that ball catching performance was less successful when patterns of hand movements and gaze behaviours were constrained by the absence of advanced perceptual information from the thrower's actions. Under these task constraints, participants began tracking the ball later, followed less of its trajectory, and adapted their actions by initiating movements later and moving the hand faster. There were no performance differences when the throwing action image and ball speed were synchronised or de-synchronised since hand movements were closely linked to information from ball trajectory. Results are interpreted relative to the two-visual system hypothesis, demonstrating that accurate interception requires integration of advanced visual information from kinematics of the throwing action and from ball flight trajectory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the ever-increasing emphasis on ocular disease recognition in the practice of optometry and especially anterior eye disease management and therapeutics, any book addressing such issues is bound to have a captive audience. This second edition of Anterior Eye Disease and Therapeutics A–Z provides a succinct yet comprehensive coverage of this topic.