149 resultados para CONE BEAM COMPUTED TOMOGRAPHY
Resumo:
This study reports on an original concept of additive manufacturing for the fabrication of tissue engineered constructs (TEC), offering the possibility of concomitantly manufacturing a customized scaffold and a bioreactor chamber to any size and shape. As a proof of concept towards the development of anatomically relevant TECs, this concept was utilized for the design and fabrication of a highly porous sheep tibia scaffold around which a bioreactor chamber of similar shape was simultaneously built. The morphology of the bioreactor/scaffold device was investigated by micro-computed tomography and scanning electron microscopy confirming the porous architecture of the sheep tibiae as opposed to the non-porous nature of the bioreactor chamber. Additionally, this study demonstrates that both the shape, as well as the inner architecture of the device can significantly impact the perfusion of fluid within the scaffold architecture. Indeed, fluid flow modelling revealed that this was of significant importance for controlling the nutrition flow pattern within the scaffold and the bioreactor chamber, avoiding the formation of stagnant flow regions detrimental for in vitro tissue development. The bioreactor/scaffold device was dynamically seeded with human primary osteoblasts and cultured under bi-directional perfusion for two and six weeks. Primary human osteoblasts were observed homogenously distributed throughout the scaffold, and were viable for the six week culture period. This work demonstrates a novel application for additive manufacturing in the development of scaffolds and bioreactors. Given the intrinsic flexibility of the additive manufacturing technology platform developed, more complex culture systems can be fabricated which would contribute to the advances in customized and patient-specific tissue engineering strategies for a wide range of applications.
Resumo:
BACKGROUND AND OBJECTIVE: Idiopathic pulmonary fibrosis (IPF) is a degenerative disease characterized by fibrosis following failed epithelial repair. Mesenchymal stromal cells (MSC), a key component of the stem cell niche in bone marrow and possibly other organs including lung, have been shown to enhance epithelial repair and are effective in preclinical models of inflammation-induced pulmonary fibrosis, but may be profibrotic in some circumstances. METHODS: In this single centre, non-randomized, dose escalation phase 1b trial, patients with moderately severe IPF (diffusing capacity for carbon monoxide (DLCO ) ≥ 25% and forced vital capacity (FVC) ≥ 50%) received either 1 × 10(6) (n = 4) or 2 × 10(6) (n = 4) unrelated-donor, placenta-derived MSC/kg via a peripheral vein and were followed for 6 months with lung function (FVC and DLCO ), 6-min walk distance (6MWD) and computed tomography (CT) chest. RESULTS: Eight patients (4 female, aged 63.5 (57-75) years) with median (interquartile range) FVC 60 (52.5-74.5)% and DLCO 34.5 (29.5-40)% predicted were treated. Both dose schedules were well tolerated with only minor and transient acute adverse effects. MSC infusion was associated with a transient (1% (0-2%)) fall in SaO2 after 15 min, but no changes in haemodynamics. At 6 months FVC, DLCO , 6MWD and CT fibrosis score were unchanged compared with baseline. There was no evidence of worsening fibrosis. CONCLUSIONS: Intravenous MSC administration is feasible and has a good short-term safety profile in patients with moderately severe IPF.
Resumo:
Molecular imaging is utilised in modern medicine to aid in the diagnosis and treatment of disease by allowing its spatiotemporal state to be examined in vivo. This study focuses on the development of novel multimodal molecular imaging agents based on hyperbranched polymers that combine the complementary capabilities of optical fluorescence imaging and positron emission tomography-computed tomography (PET/CT) into one construct. RAFT-mediated polymerisation was used to prepare two hydrophilic hyperbranched polymers that were differentiated by their size and level of branching. The multiple functional end-groups facilitated covalent attachment of both near infrared fluorescent dyes for optical imaging, as well as a copper chelator allowing binding of 64Cu as a PET radio nuclei. In vivo multimodal imaging of mice using PET/CT and planar optical imaging was first used to assess the biodistribution of the polymeric materials and it was shown that the larger and more branched polymer had a significantly longer circulation time. The larger constructs were also shown to exhibit enhanced accumulation in solid tumours in a murine B16 melanoma model. Importantly, it was demonstrated that the PET modality gave rise to high sensitivity immediately after injection of the agent, while the optical modality facilitated extended longitudinal studies, thus highlighting how the complementary capabilities of the molecular imaging agents can be useful for studying various diseases, including cancer.
Resumo:
Progeny of mice treated with the mutagen N-ethyl-N-nitrosourea (ENU) revealed a mouse, designated Longpockets (Lpk), with short humeri, abnormal vertebrae, and disorganized growth plates, features consistent with spondyloepiphyseal dysplasia congenita (SEDC). The Lpk phenotype was inherited as an autosomal dominant trait. Lpk/+ mice were viable and fertile and Lpk/Lpk mice died perinatally. Lpk was mapped to chromosome 15 and mutational analysis of likely candidates from the interval revealed a Col2a1 missense Ser1386Pro mutation. Transient transfection of wild-type and Ser1386Pro mutant Col2a1 c-Myc constructs in COS-7 cells and CH8 chondrocytes demonstrated abnormal processing and endoplasmic reticulum retention of the mutant protein. Histology revealed growth plate disorganization in 14-day-old Lpk/+ mice and embryonic cartilage from Lpk/+ and Lpk/Lpk mice had reduced safranin-O and type-II collagen staining in the extracellular matrix. The wild-type and Lpk/+ embryos had vertical columns of proliferating chondrocytes, whereas those in Lpk/Lpk mice were perpendicular to the direction of bone growth. Electron microscopy of cartilage from 18.5 dpc wild-type, Lpk/+, and Lpk/Lpk embryos revealed fewer and less elaborate collagen fibrils in the mutants, with enlarged vacuoles in the endoplasmic reticulum that contained amorphous inclusions. Micro-computed tomography (CT) scans of 12-week-old Lpk/+ mice revealed them to have decreased bone mineral density, and total bone volume, with erosions and osteophytes at the joints. Thus, an ENU mouse model with a Ser1386Pro mutation of the Col2a1 C-propeptide domain that results in abnormal collagen processing and phenotypic features consistent with SEDC and secondary osteoarthritis has been established.
Resumo:
Background Aneurysm expansion rate is an important indicator of the potential risk of abdominal aortic aneurysm (AAA) rupture. Stress within the AAA wall is also thought to be a trigger for its rupture. However, the association between aneurysm wall stresses and expansion of AAA is unclear. Methods and Results Forty-four patients with AAAs were included in this longitudinal follow-up study. They were assessed by serial abdominal ultrasonography and computed tomography scans if a critical size was reached or a rapid expansion occurred. Patient-specific 3-dimensional AAA geometries were reconstructed from the follow-up computed tomography images. Structural analysis was performed to calculate the wall stresses of the AAA models at both baseline and final visit. A nonlinear large-strain finite element method was used to compute the wall-stress distribution. The relationship between wall stresses and expansion rate was investigated. Slowly and rapidly expanding aneurysms had comparable baseline maximum diameters (median, 4.35 cm [interquartile range, 4.12 to 5.0 cm] versus 4.6 cm [interquartile range, 4.2 to 5.0 cm]; P=0.32). Rapidly expanding AAAs had significantly higher shoulder stresses than slowly expanding AAAs (median, 300 kPa [interquartile range, 280 to 320 kPa] versus 225 kPa [interquartile range, 211 to 249 kPa]; P=0.0001). A good correlation between shoulder stress at baseline and expansion rate was found (r=0.71; P=0.0001). Conclusion A higher shoulder stress was found to have an association with a rapidly expanding AAA. Therefore, it may be useful for estimating the expansion of AAAs and improve risk stratification of patients with AAAs.
Resumo:
Despite recent therapeutic advances, acute ischemic complications of atherosclerosis remain the primary cause of morbidity and mortality in Western countries, with carotid atherosclerotic disease one of the major preventable causes of stroke. As the impact of this disease challenges our healthcare systems, we are becoming aware that factors influencing this disease are more complex than previously realized. In current clinical practice, risk stratification relies primarily on evaluation of the degree of luminal stenosis and patient symptomatology. Adequate investigation and optimal imaging are important factors that affect the quality of a carotid endarterectomy (CEA) service and are fundamental to patient selection. Digital subtraction angiography is still perceived as the most accurate imaging modality for carotid stenosis and historically has been the cornerstone of most of the major CEA trials but concerns regarding potential neurological complications have generated substantial interest in non-invasive modalities, such as contrast-enhanced magnetic resonance angiography. The purpose of this review is to give an overview to the vascular specialist of the current imaging modalities in clinical practice to identify patients with carotid stenosis. Advantages and disadvantages of each technique are outlined. Finally, limitations of assessing luminal stenosis in general are discussed. This article will not cover imaging of carotid atheroma morphology, function and other emerging imaging modalities of assessing plaque risk, which look beyond simple luminal measurements.
Resumo:
The quality of ultrasound computed tomography imaging is primarily determined by the accuracy of ultrasound transit time measurement. A major problem in analysis is the overlap of signals making it difficult to detect the correct transit time. The current standard is to apply a matched-filtering approach to the input and output signals. This study compares the matched-filtering technique with active set deconvolution to derive a transit time spectrum from a coded excitation chirp signal and the measured output signal. The ultrasound wave travels in a direct and a reflected path to the receiver, resulting in an overlap in the recorded output signal. The matched-filtering and deconvolution techniques were applied to determine the transit times associated with the two signal paths. Both techniques were able to detect the two different transit times; while matched-filtering has a better accuracy (0.13 μs vs. 0.18 μs standard deviation), deconvolution has a 3.5 times improved side-lobe to main-lobe ratio. A higher side-lobe suppression is important to further improve image fidelity. These results suggest that a future combination of both techniques would provide improved signal detection and hence improved image fidelity.
Resumo:
This project has investigated how the architecture of the blood vessels supplying nutrients to skeletal muscles is affected by muscle contusion injuries, and how it changes during healing with or without initial treatment of the injury by icing. In order to do this, we used contrast agents to visualise blood vessels in 3D with micro-computed tomography imaging. This research significantly contributes to the fields of orthopaedics, traumatology and sports medicine, as it improves our understanding of muscle contusion injuries. Furthermore, the methods developed in this thesis may help to improve the diagnosis and monitoring of these injuries.
Resumo:
Sonography is an important clinical tool in diagnosing appendicitis in children as it can obviate both exposure to potentially harmful ionising radiation from computed tomography scans and the need for unnecessary appendicectomies. This review examines the diagnostic accuracy of ultrasound in the identification of acute appendicitis, with a particular focus on the the utility of secondary sonographic signs as an adjunct or corollary to traditionally examined criteria. These secondary signs can be important in cases where the appendix cannot be identified with ultrasound and a more meaningful finding may be made by incorporating the presence or absence of secondary sonographic signs. There is evidence that integrating these secondary signs into the final ultrasound diagnosis can improve the utility of ultrasound in cases where appendicitis is expected, though there remains some conjecture about whether they play a more important role in negative or positive prediction in the absence of an identifiable appendix.
Resumo:
Background Adolescent Idiopathic Scoliosis is the most common type of spinal deformity, and whilst the risk of progression appears to be biomechanically mediated (larger deformities are more likely to progress), the detailed biomechanical mechanisms driving progression are not well understood. Gravitational forces in the upright position are the primary sustained loads experienced by the spine. In scoliosis they are asymmetrical, generating moments about the spinal joints which may promote asymmetrical growth and deformity progression. Using 3D imaging modalities to estimate segmental torso masses allows the gravitational loading on the scoliotic spine to be determined. The resulting distribution of joint moments aids understanding of the mechanics of scoliosis progression. Methods Existing low-dose CT scans were used to estimate torso segment masses and joint moments for 20 female scoliosis patients. Intervertebral joint moments at each vertebral level were found by summing the moments of each of the torso segment masses above the required joint. Results The patients’ mean age was 15.3 years (SD 2.3; range 11.9 – 22.3 years); mean thoracic major Cobb angle 52° (SD 5.9°; range 42°-63°) and mean weight 57.5 kg (SD 11.5 kg; range 41 – 84.7 kg). Joint moments of up to 7 Nm were estimated at the apical level. No significant correlation was found between the patients’ major Cobb angles and apical joint moments. Conclusions Patients with larger Cobb angles do not necessarily have higher joint moments, and curve shape is an important determinant of joint moment distribution. These findings may help to explain the variations in progression between individual patients. This study suggests that substantial corrective forces are required of either internal instrumentation or orthoses to effectively counter the gravity-induced moments acting to deform the spinal joints of idiopathic scoliosis patients.
Resumo:
Sonographic diagnosis of appendicitis in children is an important clinical tool, often obviating the need for potentially harmful ionising radiation from computed tomography (CT) scans and unnecessary appendectomies. Established criteria do not commonly account for the sonographic secondary signs of acute appendicitis as an adjunct or corollary to an identifiably inflamed appendix. If one of, or combinations of these secondary signs are a reliable positive and/or negative indicator of the condition, diagnostic accuracy may be improved. This will be of particular importance in cases where the appendix cannot be easily identified, possibly providing referring clinicians with a less equivocal diagnosis. Acute appendicitis (AA) is the most common emergency presentation requiring surgical intervention among both adults and children. During 2010-11 in Australia 25000 appendicectomies were performed on adults and children, more than double the number of the next most common surgical procedure [1]. Ultrasound has been commonly used to diagnose AA since the 1980s, however the best imaging modality or combination of modalities to accurately and cost-effectively diagnose the condition is still debated. A study by Puylaert advocated ultrasound in all presentations [2], whereas others suggested it only as a first line modality [3–5]. Conversely, York et al state that it is not appropriate as it delays treatment [6]. CT has been shown to more accurately diagnose AA than ultrasound, however its inherent radiation risks warrant cautionary use in children [7]. Improved accuracy in the diagnosis of suspected AA using ultrasound would enable surgeons to make a decision without the need to expose children to the potentially harmful effects of CT. Secondary signs of appendicitis are well established [8], although research into their predictive values has only recently been undertaken [9,10] indicating their potential diagnostic benefit in the absence of an identifiable appendix. The purpose of this review is to examine the history of appendiceal sonography, established sonographic criteria, paediatric specific techniques and the predictive value of secondary signs.
Resumo:
CONTEXT: The role and importance of circulating sclerostin is poorly understood. High bone mass (HBM) caused by activating LRP5 mutations has been reported to be associated with increased plasma sclerostin concentrations; whether the same applies to HBM due to other causes is unknown. OBJECTIVE: Our objective was to determine circulating sclerostin concentrations in HBM. DESIGN AND PARTICIPANTS: In this case-control study, 406 HBM index cases were identified by screening dual-energy x-ray absorptiometry (DXA) databases from 4 United Kingdom centers (n = 219 088), excluding significant osteoarthritis/artifact. Controls comprised unaffected relatives and spouses. MAIN MEASURES: Plasma sclerostin; lumbar spine L1, total hip, and total body DXA; and radial and tibial peripheral quantitative computed tomography (subgroup only) were evaluated. RESULTS: Sclerostin concentrations were significantly higher in both LRP5 HBM and non-LRP5 HBM cases compared with controls: mean (SD) 130.1 (61.7) and 88.0 (39.3) vs 66.4 (32.3) pmol/L (both P < .001, which persisted after adjustment for a priori confounders). In combined adjusted analyses of cases and controls, sclerostin concentrations were positively related to all bone parameters found to be increased in HBM cases (ie, L1, total hip, and total body DXA bone mineral density and radial/tibial cortical area, cortical bone mineral density, and trabecular density). Although these relationships were broadly equivalent in HBM cases and controls, there was some evidence that associations between sclerostin and trabecular phenotypes were stronger in HBM cases, particularly for radial trabecular density (interaction P < .01). CONCLUSIONS: Circulating plasma sclerostin concentrations are increased in both LRP5 and non-LRP5 HBM compared with controls. In addition to the general positive relationship between sclerostin and DXA/peripheral quantitative computed tomography parameters, genetic factors predisposing to HBM may contribute to increased sclerostin levels.
Resumo:
Context: Tumor-induced osteomalacia (TIO) is a rarely diagnosed disorder presenting with bone pain, fractures, muscle weakness, and moderate-to-severe hypophosphatemia resulting from fibroblast growth factor 23-mediated renal phosphate wasting. Tumors secreting fibroblast growth factor 23 are often small and difficult to find with conventional imaging. Objective: We studied the utility of 68Ga-DOTA-octreotate (DOTATATE) somatostatin receptor positron emission tomography (PET)/computed tomography (CT) imaging in the diagnosis of TIO. Design and Setting: A multicenter case series was conducted at tertiary referral hospitals. Patients and Methods: Six patients with TIO diagnosed between 2003 and 2012 in Australia were referred for DOTATATE PET imaging. We reviewed the clinical history, biochemistry, imaging characteristics, histopathology, and clinical outcome of each patient. Results: Each case demonstrated delayed diagnosis despite severe symptoms. DOTATATE PET/CT imaging demonstrated high uptake and localized the tumor with confidence in each case. After surgical excision, there was resolution of clinical symptoms and serum phosphate, except in one patient who demonstrated residual disease on PET/CT. All tumors demonstrated high somatostatin receptor subtype 2 cell surface receptor expression using immunohistochemistry. Conclusions: In patients with TIO, DOTATATE PET/CT can successfully localize phosphaturic mesenchymal tumors and may be a practical first step in functional imaging for this disorder. Serum phosphate should be measured routinely in patients with unexplained muscle weakness, bone pain, or stress fractures to allow earlier diagnosis of TIO. - See more at: http://press.endocrine.org/doi/abs/10.1210/jc.2012-3642#sthash.eXD0CopL.dpuf
Resumo:
Evaluation of protein and metabolite expression patterns in blood using mass spectrometry and high-throughput antibody-based screening platforms has potential for the discovery of new biomarkers for managing breast cancer patient treatment. Previously identified blood-based breast cancer biomarkers, including cancer antigen 15.3 (CA15-3) are useful in combination with imaging (computed tomography scans, magnetic resonance imaging, X-rays) and physical examination for monitoring tumour burden in advanced breast cancer patients. However, these biomarkers suffer from insufficient levels of accuracy and with new therapies available for the treatment of breast cancer, there is an urgent need for reliable, non-invasive biomarkers that measure tumour burden with high sensitivity and specificity so as to provide early warning of the need to switch to an alternative treatment. The aim of this study was to identify a biomarker signature of tumour burden using cancer and non-cancer (healthy controls/non-malignant breast disease) patient samples. Results demonstrate that combinations of three candidate biomarkers from Glutamate, 12-Hydroxyeicosatetraenoic acid, Beta-hydroxybutyrate, Factor V and Matrix metalloproteinase-1 with CA15-3, an established biomarker for breast cancer, were found to mirror tumour burden, with AUC values ranging from 0.71 to 0.98 when comparing non-malignant breast disease to the different stages of breast cancer. Further validation of these biomarker panels could potentially facilitate the management of breast cancer patients, especially to assess changes in tumour burden in combination with imaging and physical examination.