53 resultados para closed-orbit distortion (COD)
Resumo:
Purpose: In 1970, Enright observed a distortion of perceived driving speed, induced by monocular application of a neutral density (ND) filter. If a driver looks out of the right side of a vehicle with a filter over the right eye, the driver perceives a reduction of the vehicle’s apparent velocity, while applying a ND filter over the left eye increases the vehicle’s apparent velocity. The purpose of the current study was to provide the first empirical measurements of the Enright phenomenon. Methods: Ten experienced drivers were tested and drove an automatic sedan on a closed road circuit. Filters (0.9 ND) were placed over the left, right or both eyes during a driving run, in addition to a control condition with no filters in place. Subjects were asked to look out of the right side of the car and adjust their driving speed to either 40 km/h or 60 km/h. Results: Without a filter or with both eyes filtered subjects showed good estimation of speed when asked to travel at 60 km/h but travelled a mean of 12 to 14 km/h faster than the requested 40 km/h. Subjects travelled faster than these baselines by a mean of 7 to 9 km/h (p < 0.001) with the filter over their right eye, and 3 to 5 km/h slower with the filter over their left eye (p < 0.05). Conclusions: The Enright phenomenon causes significant and measurable distortions of perceived driving speed under realworld driving conditions.
Resumo:
Biological tissues are subjected to complex loading states in vivo and in order to define constitutive equations that effectively simulate their mechanical behaviour under these loads, it is necessary to obtain data on the tissue's response to multiaxial loading. Single axis and shear testing of biological tissues is often carried out, but biaxial testing is less common. We sought to design and commission a biaxial compression testing device, capable of obtaining repeatable data for biological samples. The apparatus comprised a sealed stainless steel pressure vessel specifically designed such that a state of hydrostatic compression could be created on the test specimen while simultaneously unloading the sample along one axis with an equilibrating tensile pressure. Thus a state of equibiaxial compression was created perpendicular to the long axis of a rectangular sample. For the purpose of calibration and commissioning of the vessel, rectangular samples of closed cell ethylene vinyl acetate (EVA) foam were tested. Each sample was subjected to repeated loading, and nine separate biaxial experiments were carried out to a maximum pressure of 204 kPa (30 psi), with a relaxation time of two hours between them. Calibration testing demonstrated the force applied to the samples had a maximum error of 0.026 N (0.423% of maximum applied force). Under repeated loading, the foam sample demonstrated lower stiffness during the first load cycle. Following this cycle, an increased stiffness, repeatable response was observed with successive loading. While the experimental protocol was developed for EVA foam, preliminary results on this material suggest that this device may be capable of providing test data for biological tissue samples. The load response of the foam was characteristic of closed cell foams, with consolidation during the early loading cycles, then a repeatable load-displacement response upon repeated loading. The repeatability of the test results demonstrated the ability of the test device to provide reproducible test data and the low experimental error in the force demonstrated the reliability of the test data.
Resumo:
Infection of plant cells by potyviruses induces the formation of cytoplasmic inclusions ranging in size from 200 to 1000 nm. To determine if the ability to form these ordered, insoluble structures is intrinsic to the potyviral cytoplasmic inclusion protein, we have expressed the cytoplasmic inclusion protein from Potato virus Y in tobacco under the control of the chrysanthemum ribulose-1,5-bisphosphate carboxylase small subunit promoter, a highly active, green tissue promoter. No cytoplasmic inclusions were observed in the leaves of transgenic tobacco using transmission electron microscopy, despite being able to clearly visualize these inclusions in Potato virus Y infected tobacco leaves under the same conditions. However, we did observe a wide range of tissue and sub-cellular abnormalities associated with the expression of the Potato virus Y cytoplasmic inclusion protein. These changes included the disruption of normal cell morphology and organization in leaves, mitochondrial and chloroplast internal reorganization, and the formation of atypical lipid accumulations. Despite these significant structural changes, however, transgenic tobacco plants were viable and the results are discussed in the context of potyviral cytoplasmic inclusion protein function.
Resumo:
Investigated the psychometric properties of the original and alternate sets of the Trail Making Test (TMT) and the Controlled Oral Word Association Test (COWAT; A. L. Benton and D. Hamsher, 1978) in 50 orthopedic and 15 closed head injured (1 yr after trauma) patients (aged 15–59 yrs). Although the alternate forms of both measures proved to be stable and consistent with each other in both groups, only the parallel sets of TMT reliably discriminated the clinical group from controls. Practice effects in the head injured were significant only for Trail B of TMT. Factor analysis of the control group's results identified Verbal Knowledge as a major contributor to performance on COWAT, whereas TMT was more dependent on Rapid Visual Search and Visuomotor Sequencing.
Resumo:
In this paper, a fixed-switching-frequency closed-loop modulation of a voltage-source inverter (VSI), upon the digital implementation of the modulation process, is analyzed and characterized. The sampling frequency of the digital processor is considered as an integer multiple of the modulation switching frequency. An expression for the determination of the modulation design parameter is developed for smooth modulation at a fixed switching frequency. The variation of the sampling frequency, switching frequency, and modulation index has been analyzed for the determination of the switching condition under closed loop. It is shown that the switching condition determined based on the continuous-time analysis of the closed-loop modulation will ensure smooth modulation upon the digital implementation of the modulation process. However, the stability properties need to be tested prior to digital implementation as they get deteriorated at smaller sampling frequencies. The closed-loop modulation index needs to be considered maximum while determining the design parameters for smooth modulation. In particular, a detailed analysis has been carried out by varying the control gain in the sliding-mode control of a two-level VSI. The proposed analysis of the closed-loop modulation of the VSI has been verified for the operation of a distribution static compensator. The theoretical results are validated experimentally on both single- and three-phase systems.
Resumo:
Small element spacing in compact arrays results in strong mutual coupling between the array elements. A decoupling network consisting of reactive cross-coupling elements can alleviate problems associated with the coupling. Closed-form design equations for the decoupling networks of symmetrical arrays with two or three elements are presented.
Resumo:
Presbyopia affects individuals from the age of 45 years onwards, resulting in difficulty in accurately focusing on near objects. There are many optical corrections available including spectacles or contact lenses that are designed to enable presbyopes to see clearly at both far and near distances. However, presbyopic vision corrections also disturb aspects of visual function under certain circumstances. The impact of these changes on activities of daily living such as driving are, however, poorly understood. Therefore, the aim of this study was to determine which aspects of driving performance might be affected by wearing different types of presbyopic vision corrections. In order to achieve this aim, three experiments were undertaken. The first experiment involved administration of a questionnaire to compare the subjective driving difficulties experienced when wearing a range of common presbyopic contact lens and spectacle corrections. The questionnaire was developed and piloted, and included a series of items regarding difficulties experienced while driving under day and night-time conditions. Two hundred and fifty five presbyopic patients responded to the questionnaire and were categorised into five groups, including those wearing no vision correction for driving (n = 50), bifocal spectacles (BIF, n = 54), progressive addition lenses spectacles (PAL, n = 50), monovision (MV, n = 53) and multifocal contact lenses (MTF CL, n = 48). Overall, ratings of satisfaction during daytime driving were relatively high for all correction types. However, MV and MTF CL wearers were significantly less satisfied with aspects of their vision during night-time than daytime driving, particularly with regard to disturbances from glare and haloes. Progressive addition lens wearers noticed more distortion of peripheral vision, while BIF wearers reported more difficulties with tasks requiring changes in focus and those who wore no vision correction for driving reported problems with intermediate and near tasks. Overall, the mean level of satisfaction for daytime driving was quite high for all of the groups (over 80%), with the BIF wearers being the least satisfied with their vision for driving. Conversely, at night, MTF CL wearers expressed the least satisfaction. Research into eye and head movements has become increasingly of interest in driving research as it provides a means of understanding how the driver responds to visual stimuli in traffic. Previous studies have found that wearing PAL can affect eye and head movement performance resulting in slower eye movement velocities and longer times to stabilize the gaze for fixation. These changes in eye and head movement patterns may have implications for driving safety, given that the visual tasks for driving include a range of dynamic search tasks. Therefore, the second study was designed to investigate the influence of different presbyopic corrections on driving-related eye and head movements under standardized laboratory-based conditions. Twenty presbyopes (mean age: 56.1 ± 5.7 years) who had no experience of wearing presbyopic vision corrections, apart from single vision reading spectacles, were recruited. Each participant wore five different types of vision correction: single vision distance lenses (SV), PAL, BIF, MV and MTF CL. For each visual condition, participants were required to view videotape recordings of traffic scenes, track a reference vehicle and identify a series of peripherally presented targets while their eye and head movements were recorded using the faceLAB® eye and head tracking system. Digital numerical display panels were also included as near visual stimuli (simulating the visual displays of a vehicle speedometer and radio). The results demonstrated that the path length of eye movements while viewing and responding to driving-related traffic scenes was significantly longer when wearing BIF and PAL than MV and MTF CL. The path length of head movements was greater with SV, BIF and PAL than MV and MTF CL. Target recognition was less accurate when the near stimulus was located at eccentricities inferiorly and to the left, rather than directly below the primary position of gaze, regardless of vision correction type. The third experiment aimed to investigate the real world driving performance of presbyopes while wearing different vision corrections measured on a closed-road circuit at night-time. Eye movements were recorded using the ASL Mobile Eye, eye tracking system (as the faceLAB® system proved to be impractical for use outside of the laboratory). Eleven participants (mean age: 57.25 ± 5.78 years) were fitted with four types of prescribed vision corrections (SV, PAL, MV and MTF CL). The measures of driving performance on the closed-road circuit included distance to sign recognition, near target recognition, peripheral light-emitting-diode (LED) recognition, low contrast road hazards recognition and avoidance, recognition of all the road signs, time to complete the course, and driving behaviours such as braking, accelerating, and cornering. The results demonstrated that driving performance at night was most affected by MTF CL compared to PAL, resulting in shorter distances to read signs, slower driving speeds, and longer times spent fixating road signs. Monovision resulted in worse performance in the task of distance to read a signs compared to SV and PAL. The SV condition resulted in significantly more errors made in interpreting information from in-vehicle devices, despite spending longer time fixating on these devices. Progressive addition lenses were ranked as the most preferred vision correction, while MTF CL were the least preferred vision correction for night-time driving. This thesis addressed the research question of how presbyopic vision corrections affect driving performance and the results of the three experiments demonstrated that the different types of presbyopic vision corrections (e.g. BIF, PAL, MV and MTF CL) can affect driving performance in different ways. Distance-related driving tasks showed reduced performance with MV and MTF CL, while tasks which involved viewing in-vehicle devices were significantly hampered by wearing SV corrections. Wearing spectacles such as SV, BIF and PAL induced greater eye and head movements in the simulated driving condition, however this did not directly translate to impaired performance on the closed- road circuit tasks. These findings are important for understanding the influence of presbyopic vision corrections on vision under real world driving conditions. They will also assist the eye care practitioner to understand and convey to patients the potential driving difficulties associated with wearing certain types of presbyopic vision corrections and accordingly to support them in the process of matching patients to optical corrections which meet their visual needs.
Resumo:
Frontline employee behaviours are recognised as vital for achieving a competitive advantage for service organisations. The services marketing literature has comprehensively examined ways to improve frontline employee behaviours in service delivery and recovery. However, limited attention has been paid to frontline employee behaviours that favour customers in ways that go against organisational norms or rules. This study examines these behaviours by introducing a behavioural concept of Customer-Oriented Deviance (COD). COD is defined as, “frontline employees exhibiting extra-role behaviours that they perceive to defy existing expectations or prescribed rules of higher authority through service adaptation, communication and use of resources to benefit customers during interpersonal service encounters.” This thesis develops a COD measure and examines the key determinants of these behaviours from a frontline employee perspective. Existing research on similar behaviours that has originated in the positive deviance and pro-social behaviour domains has limitations and is considered inadequate to examine COD in the services context. The absence of a well-developed body of knowledge on non-conforming service behaviours has implications for both theory and practice. The provision of ‘special favours’ increases customer satisfaction but the over-servicing of customers is also counterproductive for the service delivery and costly for the organisation. Despite these implications of non-conforming service behaviours, there is little understanding about the nature of these behaviours and its key drivers. This research builds on inadequacies in prior research on positive deviance, pro-social and pro-customer literature to develop the theoretical foundation of COD. The concept of positive deviance which has predominantly been used to study organisational behaviours is applied within a services marketing setting. Further, it addresses previous limitations in pro-social and pro-customer behavioural literature that has examined limited forms of behaviours with no clear understanding on the nature of these behaviours. Building upon these literature streams, this research adopts a holistic approach towards the conceptualisation of COD. It addresses previous shortcomings in the literature by providing a well bounded definition, developing a psychometrically sound measure of COD and a conceptually well-founded model of COD. The concept of COD was examined across three separate studies and based on the theoretical foundations of role theory and social identity theory. Study 1 was exploratory and based on in-depth interviews using the Critical Incident Technique (CIT). The aim of Study 1 was to understand the nature of COD and qualitatively identify its key drivers. Thematic analysis was conducted to analyse the data and the two potential dimensions of COD behaviours of Deviant Service Adaptation (DSA) and Deviant Service Communication (DSC) were revealed in the analysis. In addition, themes representing the potential influences of COD were broadly classified as individual factors, situational factors, and organisational factors. Study 2 was a scale development procedure that involved the generation and purification of items for the measure based on two student samples working in customer service roles (Pilot sample, N=278; Initial validation sample, N=231). The results for the reliability and Exploratory Factor Analyses (EFA) on the pilot sample suggested the scale had poor psychometric properties. As a result, major revisions were made in terms of item wordings and new items were developed based on the literature to reflect a new dimension, Deviant Use of Resources (DUR). The revised items were tested on the initial validation sample with the EFA analysis suggesting a four-factor structure of COD. The aim of Study 3 was to further purify the COD measure and test for nomological validity based on its theoretical relationships with key antecedents and similar constructs (key correlates). The theoretical model of COD consisting of nine hypotheses was tested on a retail and hospitality sample of frontline employees (Retail N=311; Hospitality N=305) of a market research panel using an online survey. The data was analysed using Structural Equation Modelling (SEM). The results provided support for a re-specified second-order three-factor model of COD which consists of 11 items. Overall, the COD measure was found to be reliable and valid, demonstrating convergent validity, discriminant validity and marginal partial invariance for the factor loadings. The results showed support for nomological validity, although the antecedents had differing impact on COD across samples. Specifically, empathy and perspective-taking, role conflict, and job autonomy significantly influenced COD in the retail sample, whereas empathy and perspective-taking, risk-taking propensity and role conflict were significant predictors in the hospitality sample. In addition, customer orientation-selling orientation, the altruistic dimension of organisational citizenship behaviours, workplace deviance, and social desirability responding were found to correlate with COD. This research makes several contributions to theory. First, the findings of this thesis extend the literature on positive deviance, pro-social and pro-customer behaviours. Second, the research provides an empirically tested model which describes the antecedents of COD. Third, this research contributes by providing a reliable and valid measure of COD. Finally, the research investigates the differential effects of the key antecedents in different service sectors on COD. The research findings also contribute to services marketing practice. Based on the research findings, service practitioners can better understand the phenomenon of COD and utilise the measurement tool to calibrate COD levels within their organisations. Knowledge on the key determinants of COD will help improve recruitment and training programs and drive internal initiatives within the firm.
Resumo:
In recent years, multilevel converters are becoming more popular and attractive than traditional converters in high voltage and high power applications. Multilevel converters are particularly suitable for harmonic reduction in high power applications where semiconductor devices are not able to operate at high switching frequencies or in high voltage applications where multilevel converters reduce the need to connect devices in series to achieve high switch voltage ratings. This thesis investigated two aspects of multilevel converters: structure and control. The first part of this thesis focuses on inductance between a DC supply and inverter components in order to minimise loop inductance, which causes overvoltages and stored energy losses during switching. Three dimensional finite element simulations and experimental tests have been carried out for all sections to verify theoretical developments. The major contributions of this section of the thesis are as follows: The use of a large area thin conductor sheet with a rectangular cross section separated by dielectric sheets (planar busbar) instead of circular cross section wires, contributes to a reduction of the stray inductance. A number of approximate equations exist for calculating the inductance of a rectangular conductor but an assumption was made that the current density was uniform throughout the conductors. This assumption is not valid for an inverter with a point injection of current. A mathematical analysis of a planar bus bar has been performed at low and high frequencies and the inductance and the resistance values between the two points of the planar busbar have been determined. A new physical structure for a voltage source inverter with symmetrical planar bus bar structure called Reduced Layer Planar Bus bar, is proposed in this thesis based on the current point injection theory. This new type of planar busbar minimises the variation in stray inductance for different switching states. The reduced layer planar busbar is a new innovation in planar busbars for high power inverters with minimum separation between busbars, optimum stray inductance and improved thermal performances. This type of the planar busbar is suitable for high power inverters, where the voltage source is supported by several capacitors in parallel in order to provide a low ripple DC voltage during operation. A two layer planar busbar with different materials has been analysed theoretically in order to determine the resistance of bus bars during switching. Increasing the resistance of the planar busbar can gain a damping ratio between stray inductance and capacitance and affects the performance of current loop during switching. The aim of this section is to increase the resistance of the planar bus bar at high frequencies (during switching) and without significantly increasing the planar busbar resistance at low frequency (50 Hz) using the skin effect. This contribution shows a novel structure of busbar suitable for high power applications where high resistance is required at switching times. In multilevel converters there are different loop inductances between busbars and power switches associated with different switching states. The aim of this research is to consider all combinations of the switching states for each multilevel converter topology and identify the loop inductance for each switching state. Results show that the physical layout of the busbars is very important for minimisation of the loop inductance at each switch state. Novel symmetrical busbar structures are proposed for multilevel converters with diode-clamp and flying-capacitor topologies which minimise the worst case in stray inductance for different switching states. Overshoot voltages and thermal problems are considered for each topology to optimise the planar busbar structure. In the second part of the thesis, closed loop current techniques have been investigated for single and three phase multilevel converters. The aims of this section are to investigate and propose suitable current controllers such as hysteresis and predictive techniques for multilevel converters with low harmonic distortion and switching losses. This section of the thesis can be classified into three parts as follows: An optimum space vector modulation technique for a three-phase voltage source inverter based on a minimum-loss strategy is proposed. One of the degrees of freedom for optimisation of the space vector modulation is the selection of the zero vectors in the switching sequence. This new method improves switching transitions per cycle for a given level of distortion as the zero vector does not alternate between each sector. The harmonic spectrum and weighted total harmonic distortion for these strategies are compared and results show up to 7% weighted total harmonic distortion improvement over the previous minimum-loss strategy. The concept of SVM technique is a very convenient representation of a set of three-phase voltages or currents used for current control techniques. A new hysteresis current control technique for a single-phase multilevel converter with flying-capacitor topology is developed. This technique is based on magnitude and time errors to optimise the level change of converter output voltage. This method also considers how to improve unbalanced voltages of capacitors using voltage vectors in order to minimise switching losses. Logic controls require handling a large number of switches and a Programmable Logic Device (PLD) is a natural implementation for state transition description. The simulation and experimental results describe and verify the current control technique for the converter. A novel predictive current control technique is proposed for a three-phase multilevel converter, which controls the capacitors' voltage and load current with minimum current ripple and switching losses. The advantage of this contribution is that the technique can be applied to more voltage levels without significantly changing the control circuit. The three-phase five-level inverter with a pure inductive load has been implemented to track three-phase reference currents using analogue circuits and a programmable logic device.