62 resultados para Pelvic floor dysfunction


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to design and validate an interviewer-administered pelvic floor questionnaire that integrates bladder, bowel and sexual function, pelvic organ prolapse, severity, bothersomeness and condition-specific quality of life. Validation testing of the questionnaire was performed using data from 106 urogynaecological patients and a separately sampled community cohort of 49 women. Missing data did not exceed 2% for any question. It distinguished community and urogynaecological populations regarding pelvic floor dysfunction. The bladder domain correlated with the short version of the Urogenital Distress Inventory, bowel function with an established bowel questionnaire and prolapse symptoms with the International Continence Society prolapse quantification. Sexual function assessment reflected scores on the McCoy Female Sexuality Questionnaire. Cronbach’s α coefficients were acceptable in all domains. Kappa coefficients of agreement for the test–retest analyses varied from 0.5 to 1.0. The interviewer-administered pelvic floor questionnaire assessed pelvic floor function in a reproducible and valid fashion in a typical urogynaecological clinic.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction and hypothesis: The aim of this study was to validate a self-administered version of the already validated interviewer-administered Australian pelvic floor questionnaire. Methods: The questionnaire was completed by 163 women attending an urogynecological clinic. Face and convergent validity was assessed. Reliability testing and comparison with the interviewer-administered version was performed in a subset of 105 patients. Responsiveness was evaluated in a subset of 73 women. Results: Missing data did not exceed 4% for any question. Cronbach’s alpha coefficients were acceptable in all domains. Kappa coefficients for the test–retest analyses varied from 0.64–1.0. Prolapse symptoms correlated significantly with the pelvic organ prolapse quantification. Urodynamics confirmed the reported symptom stress incontinence in 70%. The self and interviewer administered questionnaires demonstrated equivalence. Effect sizes ranged from 0.6 to 1.4. Conclusions: This self-administered pelvic floor questionnaire assessed pelvic floor function in a reproducible and valid fashion and due to its responsiveness, can be used for routine clinical assessment and outcome research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background To describe the clinical, functional and quality of life characteristics in women with Stress Urinary Incontinence (SUI). In addition, to analyse the relationship between the variables reported by the patients and those informed by the clinicians, and the relationship between instrumented variables and the manual pelvic floor strength assessment. Methods Two hundred and eighteen women participated in this observational, analytical study. An interview about Urinary Incontinence and the quality of life questionnaires (EuroQoL-5D and SF-12) were developed as outcomes reported by the patients. Manual muscle testing and perineometry as outcomes informed by the clinician were assessed. Descriptive and correlation analysis were carried out. Results The average age of the subjects was (39.93?±?12.27 years), (24.49?±?3.54 BMI). The strength evaluated by manual testing of the right levator ani muscles was 7.79?±?2.88, the strength of left levator ani muscles was 7.51?±?2.91 and the strength assessed with the perineometer was 7.64?±?2.55. A positive correlation was found between manual muscle testing and perineometry of the pelvic floor muscles (p?pelvic floor muscles in a normal distribution of a large sample of women with SUI was done, which provided the clinic with a baseline. There is a relationship between the strength of the pelvic muscles assessed manually and that obtained by a perineometer in women with SUI. There was no relationship between these values of strength and quality of life perceived.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ankylosing spondylitis (AS), an immune-mediated arthritis, is the prototypic member of a group of conditions known as spondyloarthropathies that also includes reactive arthritis, psoriatic arthritis and enteropathic arthritis. Patients with these conditions share a clinical predisposition for spinal and pelvic joint dysfunction, as well as genetic associations, notably with HLA-B*27. Spondyloarthropathies are characterized by histopathological inflammation in entheses (regions of high mechanical stress where tendons and ligaments insert into bone) and in the subchondral bone marrow, and by abnormal osteoproliferation at involved sites. The association of AS with HLA-B*27, first described >40 years ago, led to hope that the cause of the disease would be rapidly established. However, even though many theories have been advanced to explain how HLA-B*27 is involved in AS, no consensus about the answers to this question has been reached, and no successful treatments have yet been developed that target HLA-B27 or its functional pathways. Over the past decade, rapid progress has been made in discovering further genetic associations with AS that have shed new light on the aetiopathogenesis of the disease. Some of these discoveries have driven translational ideas, such as the repurposing of therapeutics targeting the cytokines IL-12 and IL-23 and other factors downstream of this pathway. AS provides an excellent example of how hypothesis-free research can lead to major advances in understanding pathogenesis and to the development of innovative therapeutic strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is aimed at investigating the effect of web openings on the plastic bending behaviour and section moment capacity of a new cold-formed steel beam known as LiteSteel beam (LSB) using numerical modelling. Different LSB sections with varying circular hole diameter and spacing were considered. A simplified but appropriate numerical modelling technique was developed for the modelling of monosymmetric sections such as LSBs subject to bending, and was used to simulate a series of section moment capacity tests of LSB flexural members with web openings. The buckling and ultimate strength behaviour was investigated in detail and the modeling technique was further improved through a comparison of numerical and experimental results. This paper describes the simplified finite element modeling technique used in this study that includes all the significant behavioural effects affecting the plastic bending behaviour and section moment capacity of LSB sections with web holes. Numerical and test results and associated findings are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The new cold-formed LiteSteel beam (LSB) sections have found increasing popularity in residential, industrial and commercial buildings due to their lightweight and cost-effectiveness. They have the beneficial characteristics of including torsionally rigid rectangular flanges combined with economical fabrication processes. Currently there is significant interest in using LSB sections as flexural members in floor joist systems. When used as floor joists, the LSB sections require holes in the web to provide access for inspection and various services. But there are no design methods that provide accurate predictions of the moment capacities of LSBs with web holes. In this study, the buckling and ultimate strength behaviour of LSB flexural members with web holes was investigated in detail by using a detailed parametric study based on finite element analyses with an aim to develop appropriate design rules and recommendations for the safe design of LSB floor joists. Moment capacity curves were obtained using finite element analyses including all the significant behavioural effects affecting their ultimate member capacity. The parametric study produced the required moment capacity curves of LSB section with a range of web hole combinations and spans. A suitable design method for predicting the ultimate moment capacity of LSB with web holes was finally developed. This paper presents the details of this investigation and the results

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cold-formed steel members can be assembled in various combinations to provide cost-efficient and safe light gauge floor systems for buildings. Such Light gauge Steel Framing (LSF) systems are widely accepted in industrial and commercial building construction. An example application is in floor-ceiling systems. Light gauge steel floor-ceiling systems must be designed to serve as fire compartment boundaries and provide adequate fire resistance. Fire-rated floor-ceiling assemblies formed with new materials and construction methodologies have been increasingly used in buildings. However, limited research has been undertaken in the past and hence a thorough understanding of their fire resistance behaviour is not available. Recently a new composite floor-ceiling system has been developed to provide higher fire rating under standard fire conditions. But its increased fire rating could not be determined using the currently available design methods. Therefore a research project was carried out to investigate its structural and fire resistance behaviour under standard fire conditions. In this research project full scale experimental tests of the new LSF floor system based on a composite ceiling unit were undertaken using a gas furnace at the Queensland University of Technology. Both the conventional and the new steel floor-ceiling systems were tested under structural and fire loads. Full scale fire tests provided a good understanding of the fire behaviour of the LSF floor-ceiling systems and confirmed the superior performance of the new composite system. This paper presents the details of this research into the structural and fire behaviour of light gauge steel floor systems protected by the new composite panel, and the results.