77 resultados para Mobilization of body reservations


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Patients with severe back deformities can greatly benefit from customized medical seating. Customized medical seating is made by taking measurements of each individual patient and making the seat as per these measurements. The current measuring systems employed by the industry are limited to use in clinics which are generally located only in major population centres. Patients living in remote areas are severely affected by this as the clinics could be far away and inaccessible for these patients. To provide service of customized medical seating requires a new measurement system which is portable so that the system could be transported to the patients in remote areas. The requirements for a new measurement system are analysed to suite the needs of Equipment Technology Services of the Cerebral Palsy League of Queensland. Design for a new measurement system was conceptualised by reviewing systems and technologies in various scientific disciplines. Design for a new system was finalised by optimizing each individual component. The final approach was validated by measuring difficult models and repeating the process to check for process variances. This system has now been adopted for clinical evaluation by ETS Suggestions have been made for further improvements in this new measurement approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bioelectrical impedance analysis, (BIA), is a method of body composition analysis first investigated in 1962 which has recently received much attention by a number of research groups. The reasons for this recent interest are its advantages, (viz: inexpensive, non-invasive and portable) and also the increasing interest in the diagnostic value of body composition analysis. The concept utilised by BIA to predict body water volumes is the proportional relationship for a simple cylindrical conductor, (volume oc length2/resistance), which allows the volume to be predicted from the measured resistance and length. Most of the research to date has measured the body's resistance to the passage of a 50· kHz AC current to predict total body water, (TBW). Several research groups have investigated the application of AC currents at lower frequencies, (eg 5 kHz), to predict extracellular water, (ECW). However all research to date using BIA to predict body water volumes has used the impedance measured at a discrete frequency or frequencies. This thesis investigates the variation of impedance and phase of biological systems over a range of frequencies and describes the development of a swept frequency bioimpedance meter which measures impedance and phase at 496 frequencies ranging from 4 kHz to 1 MHz. The impedance of any biological system varies with the frequency of the applied current. The graph of reactance vs resistance yields a circular arc with the resistance decreasing with increasing frequency and reactance increasing from zero to a maximum then decreasing to zero. Computer programs were written to analyse the measured impedance spectrum and determine the impedance, Zc, at the characteristic frequency, (the frequency at which the reactance is a maximum). The fitted locus of the measured data was extrapolated to determine the resistance, Ro, at zero frequency; a value that cannot be measured directly using surface electrodes. The explanation of the theoretical basis for selecting these impedance values (Zc and Ro), to predict TBW and ECW is presented. Studies were conducted on a group of normal healthy animals, (n=42), in which TBW and ECW were determined by the gold standard of isotope dilution. The prediction quotients L2/Zc and L2/Ro, (L=length), yielded standard errors of 4.2% and 3.2% respectively, and were found to be significantly better than previously reported, empirically determined prediction quotients derived from measurements at a single frequency. The prediction equations established in this group of normal healthy animals were applied to a group of animals with abnormally low fluid levels, (n=20), and also to a group with an abnormal balance of extra-cellular to intracellular fluids, (n=20). In both cases the equations using L2/Zc and L2/Ro accurately and precisely predicted TBW and ECW. This demonstrated that the technique developed using multiple frequency bioelectrical impedance analysis, (MFBIA), can accurately predict both TBW and ECW in both normal and abnormal animals, (with standard errors of the estimate of 6% and 3% for TBW and ECW respectively). Isotope dilution techniques were used to determine TBW and ECW in a group of 60 healthy human subjects, (male. and female, aged between 18 and 45). Whole body impedance measurements were recorded on each subject using the MFBIA technique and the correlations between body water volumes, (TBW and ECW), and heighe/impedance, (for all measured frequencies), were compared. The prediction quotients H2/Zc and H2/Ro, (H=height), again yielded the highest correlation with TBW and ECW respectively with corresponding standard errors of 5.2% and 10%. The values of the correlation coefficients obtained in this study were very similar to those recently reported by others. It was also observed that in healthy human subjects the impedance measured at virtually any frequency yielded correlations not significantly different from those obtained from the MFBIA quotients. This phenomenon has been reported by other research groups and emphasises the need to validate the technique by investigating its application in one or more groups with abnormalities in fluid levels. The clinical application of MFBIA was trialled and its capability of detecting lymphoedema, (an excess of extracellular fluid), was investigated. The MFBIA technique was demonstrated to be significantly more sensitive, (P<.05), in detecting lymphoedema than the current technique of circumferential measurements. MFBIA was also shown to provide valuable information describing the changes in the quantity of muscle mass of the patient during the course of the treatment. The determination of body composition, (viz TBW and ECW), by MFBIA has been shown to be a significant improvement on previous bioelectrical impedance techniques. The merit of the MFBIA technique is evidenced in its accurate, precise and valid application in animal groups with a wide variation in body fluid volumes and balances. The multiple frequency bioelectrical impedance analysis technique developed in this study provides accurate and precise estimates of body composition, (viz TBW and ECW), regardless of the individual's state of health.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background--Pulmonary diffusing capacity for carbon monoxide (Dlco), alveolar capillary membrane diffusing capacity (Dm), and pulmonary capillary blood volume (Vc) are all significantly reduced after exercise. Objective--To investigate whether measurement position affects this impaired gas transfer. Methods--Before and one, two, and four hours after incremental cycle ergometer exercise to fatigue, single breath Dlco, Dm, and Vc measurements were obtained in 10 healthy men in a randomly assigned supine and upright seated position. Results--After exercise, Dlco, Dm, and Vc were significantly depressed compared with baseline in both positions. The supine position produced significantly higher values over time for Dlco (5.22 (0.13) v 4.66 (0.15) ml/min/mm Hg/l, p = 0.022) and Dm (6.78 (0.19) v 6.03 (0.19) ml/min/mm Hg/l, p = 0.016), but there was no significant position effect for Vc. There was a similar pattern of change over time for Dlco, Dm, and Vc in the two positions. Conclusions--The change in Dlco after exercise appears to be primarily due to a decrease in Vc. Although the mechanism for the reduction in Vc cannot be determined from these data, passive relocation of blood to the periphery as the result of gravity can be discounted, suggesting that active vasoconstriction of the pulmonary vasculature and/or peripheral vasodilatation is occurring after exercise.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis examines the characteristics of anthropometry and body composition in Indonesian adults and some of the risk factors including body image, eating behaviours, and physical activity. Examination on body image, eating behaviours, and physical activity demonstrates significant correlations with anthropometry and body composition in Indonesian adults. The study also identified body image distortion in some of the participants and provides suggestions for intervention development addressed to the groups of participants which have been identified as having a distorted body image.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background It is evident from previous research that the role of dietary composition in relation to the development of childhood obesity remains inconclusive. Several studies investigating the relationship between body mass index (BMI), waist circumference (WC) and/or skin fold measurements with energy intake have suggested that the macronutrient composition of the diet (protein, carbohydrate, fat) may play an important contributing role to obesity in childhood as it does in adults. This study investigated the possible relationship between BMI and WC with energy intake and percentage energy intake from macronutrients in Australian children and adolescents. Methods Height, weight and WC measurements, along with 24 h food and drink records (FDR) intake data were collected from 2460 boys and girls aged 5-17 years living in the state of Queensland, Australia. Results Statistically significant, yet weak correlations between BMI z-score and WC with total energy intake were observed in grades 1, 5 and 10, with only 55% of subjects having a physiologically plausible 24 hr FDR. Using Pearson correlations to examine the relationship between BMI and WC with energy intake and percentage macronutrient intake, no significant correlations were observed between BMI z-score or WC and percentage energy intake from protein, carbohydrate or fat. One way ANOVAs showed that although those with a higher BMI z-score or WC consumed significantly more energy than their lean counterparts. Conclusion No evidence of an association between percentage macronutrient intake and BMI or WC was found. Evidently, more robust longitudinal studies are needed to elucidate the relationship linking obesity and dietary intake.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Body composition of 292 males aged between 18 and 65 years was measured using the deuterium oxide dilution technique. Participants were divided into development (n=146) and cross-validation (n=146) groups. Stature, body weight, skinfold thickness at eight sites, girth at five sites, and bone breadth at four sites were measured and body mass index (BMI), waist-to-hip ratio (WHR), and waist-to-stature ratio (WSR) calculated. Equations were developed using multiple regression analyses with skinfolds, breadth and girth measures, BMI, and other indices as independent variables and percentage body fat (%BF) determined from deuterium dilution technique as the reference. All equations were then tested in the cross-validation group. Results from the reference method were also compared with existing prediction equations by Durnin and Womersley (1974), Davidson et al (2011), and Gurrici et al (1998). The proposed prediction equations were valid in our cross-validation samples with r=0.77- 0.86, bias 0.2-0.5%, and pure error 2.8-3.6%. The strongest was generated from skinfolds with r=0.83, SEE 3.7%, and AIC 377.2. The Durnin and Womersley (1974) and Davidson et al (2011) equations significantly (p<0.001) underestimated %BF by 1.0 and 6.9% respectively, whereas the Gurrici et al (1998) equation significantly (p<0.001) overestimated %BF by 3.3% in our cross-validation samples compared to the reference. Results suggest that the proposed prediction equations are useful in the estimation of %BF in Indonesian men.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dual-energy X-ray absorptiometry (DXA) and isotope dilution technique have been used as reference methods to validate the estimates of body composition by simple field techniques; however, very few studies have compared these two methods. We compared the estimates of body composition by DXA and isotope dilution (18O) technique in apparently healthy Indian men and women (aged 19–70 years, n 152, 48 % men) with a wide range of BMI (14–40 kg/m2). Isotopic enrichment was assessed by isotope ratio mass spectroscopy. The agreement between the estimates of body composition measured by the two techniques was assessed by the Bland–Altman method. The mean age and BMI were 37 (SD 15) years and 23·3 (SD 5·1) kg/m2, respectively, for men and 37 (SD 14) years and 24·1 (SD 5·8) kg/m2, respectively, for women. The estimates of fat-free mass were higher by about 7 (95 % CI 6, 9) %, those of fat mass were lower by about 21 (95 % CI 218,223) %, and those of body fat percentage (BF%) were lower by about 7·4 (95 % CI 28·2, 26·6) % as obtained by DXA compared with the isotope dilution technique. The Bland–Altman analysis showed wide limits of agreement that indicated poor agreement between the methods. The bias in the estimates of BF% was higher at the lower values of BF%. Thus, the two commonly used reference methods showed substantial differences in the estimates of body composition with wide limits of agreement. As the estimates of body composition are method-dependent, the two methods cannot be used interchangeably

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The rehabilitation programs of bone-anchorage prostheses relying either on the OPRA (Integrum, Sweden) or the ILP (Orthodynamics, Germany) fixation involve some forms of static load bearing exercises (LBE). So far, most of biomechanical studies of these static LBEs focused on the direct measurements of the actual forces and moments applied on the OPRA fixation of individuals with transfemoral amputation (TFA). To date, the proof-of-concept of an apparatus to conduct these kinetic measurements has been presented, along with some preliminary data. The understanding of the kinetic data is essential to improve rehabilitation programs as well as the design of upcoming loading frames. However, kinetic information alone is difficult to interpret without concomitant kinematic data. The purpose of this preliminary study was to introduce a qualitative analysis describing the different body postures during LBE for a group of TFAs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose/Objectives: To examine and compare the reliability of four body composition methods commonly used in assessing breast cancer survivors. Design: Cross-sectional. Setting: A rehabilitation facility at a university-based comprehensive cancer center in the southeastern United States. Sample: 14 breast cancer survivors aged 40-71 years. Methods: Body fat (BF) percentage was estimated via bioelectric impedance analysis (BIA), air displacement plethysmography (ADP), and skinfold thickness (SKF) using both three- and seven-site algorithms, where reliability of the methods was evaluated by conducting two tests for each method (test 1 and test 2), one immediately after the other. An analysis of variance was used to compare the results of BF percentage among the four methods. Intraclass correlation coefficient (ICC) was used to test the reliability of each method. Main Research Variable: BF percentage. Findings: Significant differences in BF percentage were observed between BIA and all other methods (three-site SKF, p < 0.001; seven-site SKF, p < 0.001; ADP, p = 0.002). No significant differences (p > 0.05) in BF percentage between three-site SKF, seven-site SKF, and ADP were observed. ICCs between test 1 and test 2 for each method were BIA = 1, ADP = 0.98, three-site SKF = 0.99, and seven-site SKF = 0.94. Conclusions: ADP and both SKF methods produce similar estimates of BF percentage in all participants, whereas BIA overestimated BF percentage relative to the other measures. Caution is recommended when using BIA as the body composition method for breast cancer survivors who have completed treatment but are still undergoing adjuvant hormonal therapy. Implications for Nursing: Measurements of body composition can be implemented very easily as part of usual care and should serve as an objective outcome measure for interventions designed to promote healthy behaviors among breast cancer survivors. - See more at: https://onf.ons.org/onf/38/4/comparison-body-composition-assessment-methods-breast-cancer-survivors#sthash.5djfTS1Q.dpuf

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since ethnic differences exist in body composition, assessment methods need to be validated prior to use in different populations. This study attempts to validate the use of Sri Lankan based body composition assessment tools on a group of 5 - 15 year old Australian children of Sri Lankan origin. The study was conducted at the Body Composition Laboratory of the Children’s Nutrition Research Centre at the Royal Children’s Hospital, Brisbane, Australia. Height (Ht), weight (Wt), segmental length (Lsegment name) and skinfold thickness (SFT) were measured. The whole body and segmental bio impedance analysis (BIA) were also measured. The body composition determined by the deuterium dilution technique (criterion method) was compared with the assessments done using prediction equations developed on Sri Lankan children. 27 boys and 15 girls were studied. All predictions of body composition parameters, except percentage fat mass (FM) assessed by the SFT-FM equation in girls gave statistically significant correlations with the criterion method. They had a low mean bias and most were not influenced by the measured parameter. Although living in a different socioeconomic state, the equations developed on children of the same ethnic background gives a better predictive value of body composition. This highlights the ethnic influence on body composition.