20 resultados para welding power source control

em Universidade do Minho


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a single-phase Series Active Power Filter (Series APF) for mitigation of the load voltage harmonic content, while maintaining the voltage on the DC side regulated without the support of a voltage source. The proposed series active power filter control algorithm eliminates the additional voltage source to regulate the DC voltage, and with the adopted topology it is not used a coupling transformer to interface the series active power filter with the electrical power grid. The paper describes the control strategy which encapsulates the grid synchronization scheme, the compensation voltage calculation, the damping algorithm and the dead-time compensation. The topology and control strategy of the series active power filter have been evaluated in simulation software and simulations results are presented. Experimental results, obtained with a developed laboratorial prototype, validate the theoretical assumptions, and are within the harmonic spectrum limits imposed by the international recommendations of the IEEE-519 Standard.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Eletrónica Industrial e Computadores

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the main operation modes for an electric vehicle (EV) battery charger framed in smart grids and smart homes, i.e., are discussed the present-day and are proposed new operation modes that can represent an asset towards EV adoption. Besides the well-known grid to vehicle (G2V) and vehicle to grid (V2G), this paper proposes two new operation modes: Home-to-vehicle (H2V), where the EV battery charger current is controlled according to the current consumption of the electrical appliances of the home (this operation mode is combined with the G2V and V2G); Vehicle-for-grid (V4G), where the EV battery charger is used for compensating current harmonics or reactive power, simultaneously with the G2V and V2G operation modes. The vehicle-to-home (V2H) operation mode, where the EV can operate as a power source in isolated systems or as an off-line uninterruptible power supply to feed priority appliances of the home during power outages of the electrical grid is presented in this paper framed with the other operation modes. These five operation modes were validated through experimental results using a developed 3.6 kW bidirectional EV battery charger prototype, which was specially designed for these operation modes. The paper describes the developed EV battery charger prototype, detailing the power theory and the voltage and current control strategies used in the control system. The paper presents experimental results for the various operation modes, both in steady-state and during transients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mestrado em Human Engineering

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Eletrónica Industrial e de Computadores

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A teoria institucional constituiu o enquadramento no qual foi suportada a pergunta geral desta investigação: como e porquê a Normalização da Contabilidade de Gestão (NCG) nos hospitais públicos portugueses surgiu e evoluiu? O objetivo geral foi compreender de forma profunda o surgimento e a mudança nas regras de NCG dos hospitais públicos portugueses no período histórico 1954-2011. Face ao enquadramento institucional que justificou uma investigação interpretativa, foi usado como método de investigação um estudo de caso explanatório. A evidência sobre o caso da NCG nos hospitais públicos portugueses foi recolhida em documentos e através de 58 entrevistas realizadas em 47 unidades de análise (nos serviços centrais de contabilidade do Ministério da Saúde e em 46 hospitais públicos, num total de 53 existentes). Quanto aos principais resultados obtidos, no período 1954-1974, as regras criadas pelo poder político para controlo dos gastos públicos e a contabilidade orçamental de base de caixa estiveram na génese dos primeiros conceitos de Contabilidade de Gestão (CG) para os serviços públicos de saúde portugueses. A transição de um regime ditatorial para um regime democrático (25 de Abril de 1974), a criação do Plano Oficial de Contabilidade (POC/77) e a implementação de um estado social com Serviço Nacional de Saúde (SNS) criaram a conjuntura crítica necessária para o surgimento de um Plano Oficial de Contabilidade para os Serviços de Saúde (POCSS/80) que incluiu regras de CG. A primeira edição do Plano de Contabilidade Analítica dos Hospitais (PCAH), aprovada em 1996, não foi uma construção de raiz, mas antes uma adaptação para os hospitais das regras de CG incluídas no POCSS/91 que havia revisto o POCSS/80. Após o início da implementação do PCAH, em 1998, ocorreram sequências de autorreforço institucionalizadoras destas normas, no período 1998-2011, por influência de pressões isomórficas coercivas que delinearam um processo de evolução incremental cujo resultado foi uma reprodução por adaptação, num contexto de dependência de recursos. Vários agentes internos e externos pressionaram, no período 2003-2011, através de sequências reativas para a desinstitucionalização do PCAH em resposta ao persistente fenómeno de loose coupling. Mas o PCAH só foi descontinuado nos hospitais com privatização da governação e rejeição dos anteriores sistemas de informação. Ao nível da extensão da teoria, este estudo de caso adotou o institucionalismo histórico na investigação em CG, quanto se sabe pela primeira vez, que se mostra útil na interpretação dos processos e dos resultados da criação e evolução de instituições de CG num determinado contexto histórico. Na condição de dependência de recursos, as sequências de autorreforço, via isomorfismo coercivo, tendem para uma institucionalização com fenómeno de loose coupling. Como resposta a este fenómeno, ocorrem sequências reativas no sentido da desinstitucionalização. Perante as pressões (políticas, funcionais, sociais e tecnológicas) desinstitucionalizadoras, o fator governação privada acelera o processo de desinstitucionalização, enquanto o fator governação pública impede ou abranda esse processo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND To validate a new practical Sepsis Severity Score for patients with complicated intra-abdominal infections (cIAIs) including the clinical conditions at the admission (severe sepsis/septic shock), the origin of the cIAIs, the delay in source control, the setting of acquisition and any risk factors such as age and immunosuppression. METHODS The WISS study (WSES cIAIs Score Study) is a multicenter observational study underwent in 132 medical institutions worldwide during a four-month study period (October 2014-February 2015). Four thousand five hundred thirty-three patients with a mean age of 51.2 years (range 18-99) were enrolled in the WISS study. RESULTS Univariate analysis has shown that all factors that were previously included in the WSES Sepsis Severity Score were highly statistically significant between those who died and those who survived (p < 0.0001). The multivariate logistic regression model was highly significant (p < 0.0001, R2 = 0.54) and showed that all these factors were independent in predicting mortality of sepsis. Receiver Operator Curve has shown that the WSES Severity Sepsis Score had an excellent prediction for mortality. A score above 5.5 was the best predictor of mortality having a sensitivity of 89.2 %, a specificity of 83.5 % and a positive likelihood ratio of 5.4. CONCLUSIONS WSES Sepsis Severity Score for patients with complicated Intra-abdominal infections can be used on global level. It has shown high sensitivity, specificity, and likelihood ratio that may help us in making clinical decisions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mestrado em Biofísica e Bionanossistemas

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Solar photovoltaic systems are an increasing option for electricity production, since they produce electrical energy from a clean renewable energy resource, and over the years, as a result of the research, their efficiency has been increasing. For the interface between the dc photovoltaic solar array and the ac electrical grid is necessary the use of an inverter (dc-ac converter), which should be optimized to extract the maximum power from the photovoltaic solar array. In this paper is presented a solution based on a current-source inverter (CSI) using continuous control set model predictive control (CCS-MPC). All the power circuits and respective control systems are described in detail along the paper and were tested and validated performing computer simulations. The paper shows the simulation results and are drawn several conclusions.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

This paper presents the proposal of a three phase current source shunt active power filter (CS-SAPF) with photovoltaic grid interface. The proposed system combines the compensation of reactive power and harmonics with the injection of energy from a solar photovoltaic array into the electrical power grid. The proposed equipment presents the advantage of giving good use to the current source inverter, even when the solar photovoltaic array is not producing energy. The paper describes the control system of the CS SAPF, the energy injection control strategy, and the current harmonics and power factor compensation strategy. Simulation results to assess the performance of the proposed system are also presented.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a comprehensive comparison of a current-source converter and a voltage-source converter for three-phase electric vehicle (EV) fast battery chargers. Taking into account that the current-source converter (CSC) is a natural buck-type converter, the output voltage can assume a wide range of values, which varies between zero and the maximum instantaneous value of the power grid phase-to-phase voltage. On the other hand, taking into account that the voltage-source converter (VSC) is a natural boost-type converter, the output voltage is always greater than the maximum instantaneous value of the power grid phase-to-phase voltage, and consequently, it is necessary to use a dc-dc buck-type converter for applications as EV fast battery chargers. Along the paper is described in detail the principle of operation of both the CSC and the VSC for EV fast chargers, as well as the main equations of the power theory and current control strategies. The comparison between both converters is mainly established in terms of the total harmonic distortion of the grid current and the estimated efficiency for a range of operation between 10 kW and 50 kW.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a three-phase three-level fast battery charger for electric vehicles (EVs) based in a current-source converter (CSC). Compared with the traditional voltage-source converters used for fast battery chargers, the CSC can be seen as a natural buck-type converter, i.e., the output voltage can assume a wide range of values, which varies between zero and the maximum instantaneous value of the power grid phase-to-phase voltage. Moreover, using the CSC it is not necessary to use a dc-dc back-end converter in the battery side, and it is also possible to control the grid current in order to obtain a sinusoidal waveform, and in phase with the power grid voltage (unitary power factor). Along the paper is described in detail the proposed CSC for EVs fast battery charging systems: the circuit topology, the power control theory, the current control strategy and the grid synchronization algorithm. Several simulation results of the EV fast battery charger operating with a maximum power of 50 kW are presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the design and the prototype implementation of a three-phase power inverter developed to drive a motor-in-wheel. The control system is implemented in a FPGA (Field Programmable Gate Array) device. The paper describes the Field Oriented Control (FOC) algorithm and the Space Vector Modulation (SVM) technique that were implemented. The control platform uses a Spartan-3E FPGA board, programmed with Verilog language. Simulation and experimental results are presented to validate the developed system operation under different load conditions. Finally are presented conclusions based on the experimental results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a multifunctional converter to interface renewable energy sources (e.g., solar photovoltaic panels) and electric vehicles (EVs) with the power grid in smart grids context. This multifunctional converter allows deliver energy from the solar photovoltaic panels to an EV or to the power grid, and exchange energy in bidirectional mode between the EV and the power grid. Using this multifunctional converter are not required multiple conversion stages, as occurs with the traditional solutions, where are necessary two power converters to integrate the solar photovoltaic system in the power grid and also two power converters to integrate an off-board EV battery charger in the power grid (dc-dc and dc-ac power converters in both cases). Taking into account that the energy provided (or delivered) from the power grid in each moment is function of the EV operation mode and also of the energy produced from the solar photovoltaic system, it is possible to define operation strategies and control algorithms in order to increase the energy efficiency of the global system and to improve the power quality of the electrical system. The proposed multifunctional converter allows the operation in four distinct cases: (a) Transfer of energy from the solar photovoltaic system to the power grid; (b) Transfer of energy from the solar photovoltaic system and from the EV to the power grid; (c) Transfer of energy from the solar photovoltaic system to the EV or to the power grid; (d) Transfer of energy between the EV and the power grid. Along the paper are described the system architecture and the control algorithms, and are also presented some computational simulation results for the four aforementioned cases. It is also presented a comparative analysis between the traditional and the proposed solution in terms of operation efficiency and estimated cost of implementation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As a renewable energy source, the use of forest biomass for electricity generation is advantageous in comparison with fossil fuels, however the activity of forest biomass power plants causes adverse impacts, affecting particularly neighbouring communities. The main objective of this study is to estimate the effects of the activity of forest biomass power plants on the welfare of two groups of stakeholders, namely local residents and the general population and we apply two stated preference methods: contingent valuation and discrete choice experiments, respectively. The former method was applied to estimate the minimum compensation residents of neighbouring communities of two forest biomass power plants in Portugal would be willing to accept. The latter method was applied among the general population to estimate their willingness to pay to avoid specific environmental impacts. The results show that the presence of the selected facilities affects individuals’ well-being. On the other hand, in the discrete choice experiments conducted among the general population all impacts considered were significant determinants of respondents’ welfare levels. The results of this study stress the importance of performing an equity analysis of the welfare effects on different groups of stakeholders from the installation of forest biomass power plants, as their effects on welfare are location and impact specific. Policy makers should take into account the views of all stakeholders either directly or indirectly involved when deciding crucial issues regarding the sitting of new forest biomass power plants, in order to achieve an efficient and equitable outcome.