9 resultados para pressure surge, rapid compression, severity index, thermal profile, thermocouple array

em Universidade do Minho


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Supplementary information available at: http://www.rsc.org/suppdata/c5/gc/c5gc02231b/c5gc02231b1.pdf

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tese de Doutoramento em Medicina

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ternary aluminium oxynitride (AlNxOy) system offers the possibility to obtain a wide range of properties by tailoring the ratio between pure Al, AlNx and AlOy and therefore opening a significant number of possible applications. In this work the thermal behaviour of AlNxOy thin films was analysed by modulated infrared radiometry (MIRR), taking as reference the binary AlOy and AlNx systems. MIRR is a non-contact and non-destructive thermal wave measurement technique based on the excitation, propagation and detection of temperature oscillations of very small amplitudes. The intended change of the partial pressure of the reactive gas (N2 and/or O2) influenced the target condition and hence the deposition characteristics which, altogether, affected the composition and microstructure of the films. Based on the MIRR measurements and their qualitative and quantitative interpretation, some correlations between the thermal transport properties of the films and their chemical/physical properties have been found. Furthermore, the potential of such technique applied in this oxynitride system, which present a wide range of different physical responses, is also discussed. The experimental results obtained are consistent with those reported in previous works and show a high potential to fulfil the demands needed for the possible applications of the systems studied. They are clearly indicative of an adequate thermal response if this particular thin film system is aimed to be applied in small sensor devices or in electrodes for biosignal acquisition, such as those for electroencephalography or electromyography as it is the case of the main research area that is being developed in the group.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays, considering the high variety of construction products, adequate material selection, based on their properties and function, becomes increasingly important. In this research, a ranking procedure developed by Czarnecki and Lukowski is applied in mortars with incorporation of phase change materials (PCM). The ranking procedure transforms experimental results of properties into one numerical value. The products can be classified according to their individual properties or even an optimized combination of different properties. The main purpose of this study was the ranking of mortars with incorporation of different contents of PCM based in different binders. Aerial lime, hydraulic lime, gypsum and cement were the binders studied. For each binder, three different mortars were developed. Reference mortars, mortars with incorporation of 40% of PCM and mortars with incorporation of 40% of PCM and 1% of fibers, were tested. Results show that the incorporation of PCM in mortars changes their global performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports the fabrication process and characterization of a flexible pressure sensor based on polydimethylsiloxane (PDMS) and multi-walled carbon nanotubes (CNT-PDMS). The proposed approach relies on patterned CNT-PDMS nanocomposite strain gauges fabricated with SU-8 microstructures (with the micropatterns) in a low‑cost and simple fabrication process. This nanocomposite polymer is mounted over a PDMS membrane, which, in turn, lies on top of a PDMS diaphragm like structure. This configuration enables the PDMS membrane to bend when pressure is applied, thereby affecting the nanocomposite strain gauges, effectively changing their electrical resistance. Carbon nanotubes have several advantages such as excellent mechanical properties, high electrical conductivity and thermal stability. Furthermore, the measurement range of the proposed sensor can be adapted according to the application by varying the CNTs content and geometry of microstructure. In addition, the sensor’s biocompatibility, low cost and simple fabrication makes it very appealing for biomechanical strain sensing. The sensor’s sensitivity was about 0.073%ΔR/mmHg.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tese de Doutoramento em Engenharia Química e Biológica.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Endometriosis Health Profile Questionnaire-30 is currently the most used questionnaire for quality of life measurement in women with endometriosis. The aim of this study is to evaluate the psychometric properties and to validate the Portuguese Endometriosis Health Profile Questionnaire-30 version. MATERIAL AND METHODS A sequential sample of 152 patients with endometriosis, followed in a Portugal reference center, were asked to complete a questionnaire on social and demographic features, the Portuguese version of the Endometriosis Health Profile Questionnaire-30 and of the Short Form Health Survey 36 Item â version 2. Appropriate statistical analysis was performed using descriptive statistics, factor analysis, internal consistency, item-total correlation and convergent validity. RESULTS Factorial analysis confirmed the validity of the five-dimension structure of the Endometriosis Health Profile Questionnaire-30 core questionnaire, which explained 83.2% of the total variance. All item-total correlations presented acceptable results and high internal consistency, with Cronbach's alpha ranging between 0.876 and 0.981 for the core questionnaire and between 0.863 and 0.951 for the modular questionnaire. Significant negative associations between similar scales of Endometriosis Health Profile Questionnaire-30 and Short Form Health Survey 36 Item â version 2 were demonstrated. Data completeness achieved was high for all dimensions. The emotional well-being scale in the core questionnaire and the infertility scale in the modular section had the highest median scores, and therefore the most negative impact on the quality of life of participating women. DISCUSSION The test-retest reliability and responsiveness of the questionnaire should be evaluated in future studies. CONCLUSION The present study demonstrates that the Portuguese version of the Endometriosis Health Profile Questionnaire-30 is a valid, reliable and acceptable tool for evaluating the health-related quality of life of Portuguese women with endometriosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports on a new façade system that uses passive solutions in the search for energy efficiency. The differentials are the versatility and flexibility of the modules, which are important advantages of the system. The thermal performance of Trombe walls and glazings and the daylighting performance of glazing were the key aspects analyzed in the results. Computational simulations were accomplished for the thermal performance of different arrangements of the modules with DesignBuilder software. The glazing daylighting performance was studied by means of Ecotect and Desktop Radiance programs and compared with the transmittance curves of glazings. Occupancy profile and internal gains were fixed according to the Portuguese reality for both studies. The main characteristics considered in this research were the use of two double glazings, four different climates in Portugal and one and two Trombe walls in the façade. The results show an important reduction in the energy consumption with the use of Trombe walls and double self-cleaning glazing in the façade, which also presented better daylighting performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The influence of the feed composition upon the actual degrees of separation attained at the top and bottom sections of a thermogravitational column is discussed using the classical phenomenological theory of Furry, Jones, and Onsager. It is shown that, except for a feed composition of C 0 = 0.5 (mass fraction), the separation profile is nonsymmetric, i.e., the separations in the top and bottom sections of the column are nonsymmetric with respect to the feed composition, the asymmetry increasing as the feed composition moves away from C 0 = 0.5. An equation for the determination of the optimum feed location as a function of the feed composition is derived.