11 resultados para permeabilidade nasal
em Universidade do Minho
Resumo:
Tese de Doutoramento em Engenharia Química e Biológica.
Resumo:
Dissertação de mestrado em Ciências da Linguagem
Resumo:
Purpose. The purpose of this work was to evaluate the potential of a novel custom-designed rigid gas permeable (RGP) contact lens to modify the relative peripheral refractive error in a sample of myopic patients. Methods. Fifty-two right eyes of 52 myopic patients (mean [TSD] age, 21 [T2] years) with spherical refractive errors ranging from j0.75 to j8.00 diopters (D) and refractive astigmatism of 1.00 D or less were fitted with a novel experimental RGP (ExpRGP) lens designed to create myopic defocus in the peripheral retina. A standard RGP (StdRGP) lens was used as a control in the same eye. The relative peripheral refractive error was measured without the lens and with each of two lenses (StdRGP and ExpRGP) using an open-field autorefractometer from 30 degrees nasal to 30 degrees temporal, in 5-degree steps. The effectiveness of the lens design was evaluated as the amount of relative peripheral refractive error difference induced by the ExpRGP compared with no lens and with StdRGP conditions at 30 degrees in the nasal and temporal (averaged) peripheral visual fields. Results. Experimental RGP lens induced a significant change in relative peripheral refractive error compared with the nolens condition (baseline), beyond the 10 degrees of eccentricity to the nasal and temporal side of the visual field (p G 0.05). The maximum effect was achieved at 30 degrees. Wearing the ExpRGP lens, 60% of the eyes had peripheral myopia exceeding j1.00 D, whereas none of the eyes presented with this feature at baseline. There was no significant correlation (r = 0.04; p = 0.756) between the degree of myopia induced at 30 degrees of eccentricity of the visual field with the ExpRGP lens and the baseline refractive error. Conclusions. Custom-designed RGP contact lenses can generate a significant degree of relative peripheral myopia in myopic patients regardless of their baselin spherical equivalent refractive error.
Resumo:
Purpose: The purpose of this study was to evaluate the effect of orthokeratology for different degrees of myopia correction in the relative location of tangential (FT) and sagittal (FS) power errors across the central 70 of the visual field in the horizontal meridian. Methods: Thirty-four right eyes of 34 patients with a mean age of 25.2 ± 6.4 years were fitted with Paragon CRT (Mesa, AZ) rigid gas permeable contact lenses to treat myopia (2.15 ± 1.26D, range: 0.88 to 5.25D). Axial and peripheral refraction were measured along the central 70 of the horizontal visual field with the Grand Seiko WAM5500 open-field auto-refractor. Spherical equivalent (M), as well as tangential (FT) and sagittal power errors (FS) were obtained. Analysis was stratified in three groups according to baseline spherical equivalent: Group 1 [MBaseline = 0.88 to 1.50D; n = 11], Group 2 [MBaseline = 1.51 to 2.49D; n = 11], and Group 3 [MBaseline = 2.50 to 5.25D; n = 12]. Results: Spherical equivalent was significantly more myopic after treatment beyond the central 40 of the visual field (p50.001). FT became significantly more myopic for all groups in the nasal and temporal retina with 25 (p 0.017), 30 (p 0.007) and 35 (p 0.004) of eye rotation. Myopic change in FS was less consistent, achieving only statistical significance for all groups at 35 in the nasal and temporal retina (p 0.045). Conclusions: Orthokeratology changes significantly FT in the myopic direction beyond the central 40 of the visual field for all degrees of myopia. Changes induced by orthokeratology in relative peripheral M, FT and FS with 35 of eye rotation were significantly correlated with axial myopia at baseline. Keywords: Field
Resumo:
Tese de Doutoramento em Engenharia Química e Biológica (área de conhecimento em Engenharia Enzimática e das Fermentações)
Resumo:
Dissertação de mestrado integrado em Engenharia de Materiais
Resumo:
Tese de Doutoramento em Biologia de Plantas
Resumo:
Tese de Doutoramento em Engenharia Química e Biológica.
Resumo:
Tese de Doutoramento em Biologia das Plantas - MAP BIOPLANT
Resumo:
A aplicação ao caso literário do termo e do conceito de retrato, aqui incluindo a espécie mais tardia do autorretrato, não é hoje fluente, apesar da reconhecida permeabilidade do género a inúmeras linguagens artísticas e apesar de uma longa tradição de descrições de figura – particularmente no que toca a representação poético-retórica da beleza feminina – que recua à poesia clássica. Partindo de uma possível distinção entre autorretrato literário e variantes várias de escritas intimistas e autobiográficas com as quais delineia fronteiras nem sempre rigorosamente nítidas, é nosso propósito ilustrar, recorrendo a casos selecionados, modos de concretização verbal de autorretrato que se distanciam progressivamente de um paradigma representativo fundado na perceção e na semelhança, aproximando-se ao contrário de registos de rasura, apagamento, ruína, cegueira que questionam uma noção de identidade estabilizável em imagem (visual ou mental), encaminhando o gesto autorrepresentativo para uma meditação sobre a diferença e sobre o irreconhecimento; no limite, para uma condição fora do visível e porventura, arriscando os seus mais básicos pressupostos, para lá da representação.
Resumo:
Dissertação de mestrado em Português Língua Não Materna (PLNM): Português Língua Estrangeira (PLE) Português Língua Segunda (PL2)