12 resultados para goldfish, white light, color vision, saturation
em Universidade do Minho
Resumo:
It is well known that color coding facilitates search and iden- tification in real-life tasks. The aim of this work was to compare reac- tion times for normal color and dichromatic observers in a visual search experiment. A unique distracter color was used to avoid abnormal color vision vulnerability to background complexity. Reaction times for nor- mal color observers and dichromats were estimated for 2◦ central vision at 48 directions around a white point in CIE L∗a∗b∗ color space for systematic examination on the mechanisms of dichromatic color percep- tion. The results show that mean search times for dichromats were twice larger compared to the normal color observers and for all directions. The difference between the copunctual confusion lines and the confusion direction measure experimentally was 5.5◦ for protanopes and 7.5◦ for deuteranopes.
Resumo:
Tese de Doutoramento em Medicina
Resumo:
In this work, Ba0.8Sr0.2TiO3 (BST)/ITO structures were grown on glass substrate and laser assisted annealing (LAA) was performed to promote the crystallization of BST. Atomic force microscopy and X-ray diffraction studies confirm the crack free and polycrystalline perovskite phase of BST. White light controlled resistive switching (RS) effect in Au/BST/ITO device is investigated. The device displays the electroforming-free bipolar RS characteristics and are explained by the modulationof the width and height of barrier at the BST/ITO interface via ferroelectric polarization. Moreover, the RS effect is signifi- cantly improved under white light illumination compared to that in the dark. The enhanced RS and photovoltaic effects are explained by considering depolarization field and charge distribution at the interface. The devices exhibit stable retention characteristics with low currents (mA), which make them attractive for non volatile memory devices.
Resumo:
Dissertação de mestrado em Optometria Avançada
Resumo:
Background and aim: A significant proportion of patients presenting with obscure gastrointestinal bleeding (OGIB) have negative small bowel capsule endoscopy (SBCE) examinations, and yet remain at risk of rebleeding. We aimed to evaluate whether a second-look review of SBCE images using flexible spectral color enhancement (FICE) may improve the detection of potentially bleeding lesions. Materials and methods: This was a retrospective, single-center study including consecutive patients with OGIB subjected to SBCE, whose standard white light examination was nondiagnostic. Each SBCE was reviewed using FICE 1. New findings were labeled as either P1 or P2 lesions according to bleeding potential. Patients were followed up to assess the incidence of rebleeding. Results: A total of 42 consecutive patients were included. Sixteen patients (38%) experienced rebleeding after a mean follow-up of 26 months. Review of SBCE images using FICE 1 enabled the identification of previously unrecognized P2 lesions, mainly angioectasias, in nine patients (21%) and P1 lesions, mainly erosions, in 26 patients (62%). Among patients who experienced rebleeding, 13/16 (81%) were diagnosed with P1 lesions with FICE 1 (P=0.043), whereas 3/16 (19%) had confirmed nondiagnostic SBCE and only 1/16 (6%) had newly diagnosed P2 (plus P1) lesions. An alternative source of bleeding outside the small bowel was found in only 3/16 (19%) patients with rebleeding during the follow-up. Conclusion: In a significant proportion of patients with OGIB, FICE 1 may detect potentially bleeding lesions previously missed under conventional white light SBCE. Review of nondiagnostic SBCE with FICE 1 may be a valuable strategy to obviate the need for further investigations in patients with OGIB, particularly for those who experience rebleeding.
Resumo:
Tese de Doutoramento em Ciências da Comunicação
Resumo:
Dissertação de mestrado em Engenharia e Gestão da Qualidade
Resumo:
Biopolymer-based materials have been of particular interest as alternatives do synthetic polymers due to their low toxicity, biodegradability and biocompatibility. Among them, chitosan is one of the most studied ones and has recently been investigated for the application as solid state polymer electrolytes. Furthermore, it can serve as a host for luminescent species such as rare earth ions, giving rise to materials with increased functionality, of particular interest for electrochemical devices. In this study, we investigate chitosan based luminescent materials doped wit Eu3+ and Li+ triflate salts from the structural, photophysical and conductivity points of view. Because the host presents a broad emission band in the blue to green, while Eu3+ emits in the red, fine tuning of emission colour and/or generation of white light is possible by optimizing composition and excitation scheme. Europium lifetimes (5D0) are in the range 270 – 350 µs and quantum yields are as high as 2%. Although Li+ does not interfere with the luminescent properties, it grants ion-conducting properties to the material suggesting that a combination of both properties could be further explored in multifunctional device.
Resumo:
The aim of this work was to investigate the effect on a display gamut of varying the optical density and the position of the maximum sensitivity of the cones spectra of anomalous trichromatic observers. The anomalous cone spectral sensitivities were estimated for a set of varying optical density and maximum sensitivity spectra conditions and used to compute the display color gamut. The computed display gamut simulated for normal observers the chro- matic diversity perceived by anomalous observers. It was found that even small variations on the optical density and on the position of the maximum sensitivity spectra have an impact on the simulations of the display gamut for anomalous observers. It was also found that simulations for deuteroanomalous observers are the ones with greater impact if the estimation of the corresponding color display gamut is not carefully adjusted for the observer.
Resumo:
Observers can adjust the spectrum of illumination on paintings for optimal viewing experience. But can they adjust the colors of paintings for the best visual impression? In an experiment carried out on a calibrated color moni- tor images of four abstract paintings obtained from hyperspectral data were shown to observers that were unfamiliar with the paintings. The color volume of the images could be manipulated by rotating the volume around the axis through the average (a*, b*) point for each painting in CIELAB color space. The task of the observers was to adjust the angle of rotation to produce the best subjective impression from the paintings. It was found that the distribution of angles selected for data pooled across paintings and observers could be de- scribed by a Gaussian function centered at 10o, i.e. very close to the original colors of the paintings. This result suggest that painters are able to predict well what compositions of colors observers prefer.
Resumo:
Tese de Doutoramento em Engenharia Eletrónica e de Computadores.
Resumo:
METHODS: Refractive lens exchange was performed with implantation of an AT Lisa 839M (trifocal) or 909MP (bifocal toric) IOL, the latter if corneal astigmatism was more than 0.75 diopter (D). The postoperative visual and refractive outcomes were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. A control group of eyes in which a Tecnis ZCB00 1-piece monofocal IOL was implanted had the same examinations. RESULTS: A trifocal or bifocal toric IOL was implanted in 66 eyes. The control IOL was implanted in 18 eyes. All 3 groups obtained a significant improvement in uncorrected distance visual acuity (UDVA) (P < .001) and corrected distance visual acuity (CDVA) (P Z .001). The mean uncorrected near visual acuity (UNVA) was 0.123 logMAR with the trifocal IOL and 0.130 logMAR with the bifocal toric IOL. The residual refractive cylinder was less than 1.00 D in 86.7% of cases with the toric IOL. The mean light-distortion index was significantly higher in the multifocal IOL groups than in the monofocal group (P < .001), although no correlation was found between the light-distortion index and CDVA. CONCLUSIONS: The multifocal IOLs provided excellent UDVA and functional UNVA despite increased light-distortion indices. The light-distortion analyzer reliably quantified a subjective component of vision distinct from visual acuity; it may become a useful adjunct in the evaluation of visual quality obtained with multifocal IOLs.