9 resultados para gastrointestinal resistance

em Universidade do Minho


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports on an innovative approach to measuring intraluminal pressure in the upper gastrointestinal (GI) tract, especially monitoring GI motility and peristaltic movements. The proposed approach relies on thin-film aluminum strain gauges deposited on top of a Kapton membrane, which in turn lies on top of an SU-8 diaphragm-like structure. This structure enables the Kapton membrane to bend when pressure is applied, thereby affecting the strain gauges and effectively changing their electrical resistance. The sensor, with an area of 3.4 mm2, is fabricated using photolithography and standard microfabrication techniques (wet etching). It features a linear response (R2 = 0.9987) and an overall sensitivity of 2.6 mV mmHg−1. Additionally, its topology allows a high integration capability. The strain gauges’ responses to pressure were studied and the fabrication process optimized to achieve high sensitivity, linearity, and reproducibility. The sequential acquisition of the different signals is carried out by a microcontroller, with a 10-bit ADC and a sample rate of 250 Hz. The pressure signals are then presented in a user-friendly interface, developed using the Integrated Development Environment software, QtCreator IDE, for better visualization by physicians.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents and discusses the results of the serviciability and use condition tests carried on an innovative solution for partitions, designated AdjustMembrane developed within a research project. The proposed system is a modular non-loadbearing wall, tensioned between the pavements and ceiling slabs, which are used as anchoring elements. It allows several advantages, related with the weight reduction to achieve a good sustainable performance, such as the reduction of construction costs, energy, and materials, and it is easy to recycle and to reuse, allowing self-construction. Apart from a general presentation of the partition technology, this paper presents and discusses the results of experimental tests carried out. From the results obtained, it is possible to conclude that the solution fulfils the requirements for this typology of wall in terms of resistance to horizontal loads induced by soft and hard body impacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper deals with the experimental assessment of the effectiveness of steel fibre reinforcement in terms of punching resistance of centrically loaded flat slabs, and to the development of an analytical model capable of predicting the punching behaviour of this type of structures. For this purpose, eight slabs of 2550 x 2550 x 150 mm3 dimensions were tested up to failure, by investigating the influence of the content of steel fibres (0, 60, 75 and 90 kg/m3) and concrete strength class (50 and 70 MPa). Two reference slabs without fibre reinforcement, one for each concrete strength class, and one slab for each fibre content and each strength class compose the experimental program. All slabs were flexurally reinforced with a grid of ribbed steel bars in a percentage to assure punching failure mode for the reference slabs. Hooked ends steel fibres provided the unique shear reinforcement. The results have revealed that steel fibres are very effective in converting brittle punching failure into ductile flexural failure, by increasing both the ultimate load and deflection, as long as adequate fibre reinforcement is assured. An analytical model was developed based on the most recent concepts proposed by the fib Mode Code 2010 for predicting the punching resistance of flat slabs and for the characterization of the behaviour of fibre reinforced concrete. The most refined version of this model was capable of predicting the punching resistance of the tested slabs with excellent accuracy and coefficient of variation of about 5%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study assesses rutting on two types of modified asphalt mixtures containing: (i) amorphous polyolefin polymer and (ii) a particular polymer obtained by combining LDPE (low density polyethylene) and EVA (ethyl-vinyl-acetate). Rutting tests were performed by a wheel tracking device. Stiffness and fatigue tests were carried out to confirm the performance of the asphalt mixtures. The testing showed that polymer modification in this study improved rut resistance without compromising the stiffness and fatigue behavior. The rutting results were fit in the NCHRP 1-37A model and the in situ rutting performance of asphalt mixtures can be predicted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Biologia Molecular, Biotecnologia e Bioempreendedorismo em Plantas

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Somatic mutations in the promoter region of telomerase reverse transcriptase (TERT) gene, mainly at positions c. − 124 and c. − 146 bp, are frequent in several human cancers; yet its presence in gastrointestinal stromal tumor (GIST) has not been reported to date. Herein, we searched for the presence and clinicopathological association of TERT promoter mutations in genomic DNA from 130 bona fide GISTs. We found TERT promoter mutations in 3.8% (5/130) of GISTs. The c. − 124C4T mutation was the most common event, present in 2.3% (3/130), and the c. − 146C4T mutation in 1.5% (2/130) of GISTs. No significant association was observed between TERT promoter mutation and patient’s clinicopathological features. The present study establishes the low frequency (4%) of TERT promoter mutations in GISTs. Further studies are required to confirm our findings and to elucidate the hypothetical biological and clinical impact of TERT promoter mutation in GIST pathogenesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article presents results of an experimental investigation on the resistance to chemical attack (with sulphuric, hydrochloric and nitric acid) of several materials: OPC concrete, high-performance concrete, epoxy resin, acrylic painting and a fly ash-based geopolymeric mortar). Three types of acids with three high concentrations (10, 20 and 30%) were used to simulate long-term degradation. A cost analysis was also performed. The results show that the epoxy resin has the best resistance to chemical attack independently of the acid type and the acid concentration. However, the cost analysis shows that the epoxy resin-based solution is the least cost-efficient solution being 70% above the cost efficiency of the fly ash-based geopolymeric mortar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here, we evaluate the diagnostic and prognostic role of liquid-based cytology (LBC) in different body lesions, including thyroid, lung, effusions and malignant breast lesions. LBC has gained consensus after being applied to both non-gynecologic and fine-needle aspiration cytology. Although some remain sceptical regarding the diagnostic efficacy of LBC, mainly when used alone, in recent years, good results have been obtained as long as it showed a high diagnostic accuracy. Here, we discuss the additional possibility of storing material for the application of ancillary techniques (immunocytochemistry–molecular analysis) with several diagnostic and prognostic advantages, which may pave the way for the challenging evaluation of both monitoring responses to treatment and resistance to targeted therapies in thyroid, lung, breast carcinoma or malignant effusions. Furthermore, it provides the use of several molecular spots as specific targets for personalized therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and aim: A significant proportion of patients presenting with obscure gastrointestinal bleeding (OGIB) have negative small bowel capsule endoscopy (SBCE) examinations, and yet remain at risk of rebleeding. We aimed to evaluate whether a second-look review of SBCE images using flexible spectral color enhancement (FICE) may improve the detection of potentially bleeding lesions. Materials and methods: This was a retrospective, single-center study including consecutive patients with OGIB subjected to SBCE, whose standard white light examination was nondiagnostic. Each SBCE was reviewed using FICE 1. New findings were labeled as either P1 or P2 lesions according to bleeding potential. Patients were followed up to assess the incidence of rebleeding. Results: A total of 42 consecutive patients were included. Sixteen patients (38%) experienced rebleeding after a mean follow-up of 26 months. Review of SBCE images using FICE 1 enabled the identification of previously unrecognized P2 lesions, mainly angioectasias, in nine patients (21%) and P1 lesions, mainly erosions, in 26 patients (62%). Among patients who experienced rebleeding, 13/16 (81%) were diagnosed with P1 lesions with FICE 1 (P=0.043), whereas 3/16 (19%) had confirmed nondiagnostic SBCE and only 1/16 (6%) had newly diagnosed P2 (plus P1) lesions. An alternative source of bleeding outside the small bowel was found in only 3/16 (19%) patients with rebleeding during the follow-up. Conclusion: In a significant proportion of patients with OGIB, FICE 1 may detect potentially bleeding lesions previously missed under conventional white light SBCE. Review of nondiagnostic SBCE with FICE 1 may be a valuable strategy to obviate the need for further investigations in patients with OGIB, particularly for those who experience rebleeding.