23 resultados para WHITE-LIGHT EMISSION
em Universidade do Minho
Resumo:
In this work, Ba0.8Sr0.2TiO3 (BST)/ITO structures were grown on glass substrate and laser assisted annealing (LAA) was performed to promote the crystallization of BST. Atomic force microscopy and X-ray diffraction studies confirm the crack free and polycrystalline perovskite phase of BST. White light controlled resistive switching (RS) effect in Au/BST/ITO device is investigated. The device displays the electroforming-free bipolar RS characteristics and are explained by the modulationof the width and height of barrier at the BST/ITO interface via ferroelectric polarization. Moreover, the RS effect is signifi- cantly improved under white light illumination compared to that in the dark. The enhanced RS and photovoltaic effects are explained by considering depolarization field and charge distribution at the interface. The devices exhibit stable retention characteristics with low currents (mA), which make them attractive for non volatile memory devices.
Resumo:
Biopolymer-based materials have been of particular interest as alternatives do synthetic polymers due to their low toxicity, biodegradability and biocompatibility. Among them, chitosan is one of the most studied ones and has recently been investigated for the application as solid state polymer electrolytes. Furthermore, it can serve as a host for luminescent species such as rare earth ions, giving rise to materials with increased functionality, of particular interest for electrochemical devices. In this study, we investigate chitosan based luminescent materials doped wit Eu3+ and Li+ triflate salts from the structural, photophysical and conductivity points of view. Because the host presents a broad emission band in the blue to green, while Eu3+ emits in the red, fine tuning of emission colour and/or generation of white light is possible by optimizing composition and excitation scheme. Europium lifetimes (5D0) are in the range 270 – 350 µs and quantum yields are as high as 2%. Although Li+ does not interfere with the luminescent properties, it grants ion-conducting properties to the material suggesting that a combination of both properties could be further explored in multifunctional device.
Resumo:
Tese de Doutoramento em Medicina
Resumo:
Tese de Doutoramento em Engenharia Eletrónica e de Computadores.
Resumo:
Background and aim: A significant proportion of patients presenting with obscure gastrointestinal bleeding (OGIB) have negative small bowel capsule endoscopy (SBCE) examinations, and yet remain at risk of rebleeding. We aimed to evaluate whether a second-look review of SBCE images using flexible spectral color enhancement (FICE) may improve the detection of potentially bleeding lesions. Materials and methods: This was a retrospective, single-center study including consecutive patients with OGIB subjected to SBCE, whose standard white light examination was nondiagnostic. Each SBCE was reviewed using FICE 1. New findings were labeled as either P1 or P2 lesions according to bleeding potential. Patients were followed up to assess the incidence of rebleeding. Results: A total of 42 consecutive patients were included. Sixteen patients (38%) experienced rebleeding after a mean follow-up of 26 months. Review of SBCE images using FICE 1 enabled the identification of previously unrecognized P2 lesions, mainly angioectasias, in nine patients (21%) and P1 lesions, mainly erosions, in 26 patients (62%). Among patients who experienced rebleeding, 13/16 (81%) were diagnosed with P1 lesions with FICE 1 (P=0.043), whereas 3/16 (19%) had confirmed nondiagnostic SBCE and only 1/16 (6%) had newly diagnosed P2 (plus P1) lesions. An alternative source of bleeding outside the small bowel was found in only 3/16 (19%) patients with rebleeding during the follow-up. Conclusion: In a significant proportion of patients with OGIB, FICE 1 may detect potentially bleeding lesions previously missed under conventional white light SBCE. Review of nondiagnostic SBCE with FICE 1 may be a valuable strategy to obviate the need for further investigations in patients with OGIB, particularly for those who experience rebleeding.
Resumo:
We investigate the spontaneous emission rate of a two-level quantum emitter near a graphene-coated substrate under the influence of an external magnetic field or strain induced pseudo-magnetic field. We demonstrate that the application of the magnetic field can substantially increase or decrease the decay rate. We show that a suppression as large as 99$\%$ in the Purcell factor is achieved even for moderate magnetic fields. The emitter's lifetime is a discontinuous function of $|{\bf B}|$, which is a direct consequence of the occurrence of discrete Landau levels in graphene. We demonstrate that, in the near-field regime, the magnetic field enables an unprecedented control of the decay pathways into which the photon/polariton can be emitted. Our findings strongly suggest that a magnetic field could act as an efficient agent for on-demand, active control of light-matter interactions in graphene at the quantum level.
Resumo:
The acoustic emission (AE) technique is used for investigating the interfacial fracture and damage propagation in GFRP-and SRG-strengthened bricks during debonding tests. The bond behavior is investigated through single-lap shear bond tests and the fracture progress during the tests is recorded by means of AE sensors. The fracture progress and active debonding mechanisms are characterized in both specimen types with the aim of AE outputs. Moreover, a clear distinction between the AE outputs of specimens with different failure modes, in both SRG-and GFRP-strengthened specimens, is found which allows characterizing the debonding failure mode based on acoustic emission data.
Resumo:
Tese de Doutoramento em Ciências - Especialidade em Biologia
Resumo:
[Excerpt] Synchronization of periodic movements like side-by-side walking [7] is frequently modeled by coupled oscillators [5] and the coupling strength is defined quantitatively [3]. In contrast, in most studies on sensorimotor synchronization (SMS), simple movements like finger taps are synchronized with simple stimuli like metronomes [4]. While the latter paradigm simplifies matters and allows for the assessment of the relative weights of sensory modalities through systematic variation of the stimuli [1], it might lack ecological validity. Conversely, using more complex movements and stimuli might complicate the specification of mechanisms underlying coupling. We merged the positive aspects of both approaches to study the contribution of auditory and visual information on synchronization during side-by-side walking. As stimuli, we used Point Light Walkers (PLWs) and auralized steps sound; both were constructed from previously captured walking individuals [2][6]. PLWs were retro-projected on a screen and matched according to gender, hip height, and velocity. The participant walked for 7.20m side by side with 1) a PLW, 2) steps sound, or 3) both displayed in temporal congruence. Instruction to participants was to synchronize with the available stimuli. [...]
Resumo:
Polymer based scintillator composites have been produced by combining polystyrene (PS) and Gd2O3:Eu3+ scintillator nanoparticles. Polystyrene has been used since it is a flexible and stable binder matrix, resistant to thermal and light deterioration and with suitable optical properties. Gd2O3:Eu3+ has been selected as scintillator material due to its wide band gap, high density and visible light yield. The optical, thermal and electrical characteristics of the composites were studied as a function of filler content, together with their performance as scintillator material. Additionally 1wt.% of 2,5 dipheniloxazol (PPO) and 0.01wt.% of (1,4-bis(2-(5-phenioxazolil))-benzol (POPOP) were introduced in the polymer matrix in order to strongly improve light yield, i.e. the measured intensity of the output visible radiation, under X-ray irradiation. Whereas increasing scintillator filler concentration (from 0.25wt.% to 7.5wt.%) increases scintillator light yield, decreases the optical transparency of the composite. The addition of PPO and POPOP, strongly increased the overall 2 transduction performance of the composite due to specific absorption and re-emission processes. It is thus shown that Gd2O3:Eu3+/PPO/POPOP/PS composites in 0.25 wt.% of scintillator content with fluorescence molecules is suitable for the development of innovate large area X-ray radiation detectors with huge demand from the industries.
Resumo:
Construction sector is one of the major responsible for energy consumption and carbon emissions and renovation of existing buildings plays an important role in the actions to mitigate climate changes. Present work is based on the methodology developed in IEA Annex 56, allowing identifying cost optimal and cost effective renovation scenarios improving the energy performance. The analysed case study is a residential neighbourhood of the municipality of Gaia in Portugal. The analysis compares a reference renovation scenario (without improving the energy performance of the building) with a series of alternative renovation scenarios, including the one that is being implemented.
Resumo:
We theoretically investigate light propagation and Anderson localization in one-dimensional disordered superlattices composed of dielectric stacks with graphene sheets in between. Disorder is introduced either on graphene material parameters ({\it e.g.} Fermi energy) or on the widths of the dielectric stacks. We derive an analytic expression for the localization length $\xi$, and compare it to numerical simulations using transfer matrix technique; a very good agreement is found. We demonstrate that the presence of graphene may strongly attenuate the anomalously delocalised Breswter modes, and is at the origin of a periodic dependence of $\xi$ on frequency, in contrast to the usual asymptotic decay, $\xi \propto \omega^{-2}$. By unveiling the effects of graphene on Anderson localization of light, we pave the way for new applications of graphene-based, disordered photonic devices in the THz spectral range.
Resumo:
Artigo completo publicado na revista "BioMed Research International, (2015), 1-7" e disponível no RepositóriUM em: http://hdl.handle.net/1822/33375
Resumo:
Our objective was to validate a new device dedicated to measure the light disturbances surrounding bright sources of light under different sources of potential variability. Twenty subjects were involved in the study. Light distortion was measured using an experimental prototype (light distortion analyzer, CEORLab, University of Minho, Portugal) comprising twenty-four LED arrays panel at 2 m. Sources of variability included: intrasession and intersession repeated measures, pupil size (3 versus 6 mm), defocus (þ0.50) correction for the working distance, angular resolution (15 deg versus 30 deg), temporal stimuli presentation, and pupil size. Size, shape, location, and irregularity parameters have been obtained. At a low speed of presentation of the stimuli, changes in angular resolution did not have an effect on the results of the parameters measured. Results did not change with pupil size. Intensity of the central glare source significantly influenced the outcomes. Examination time was reduced by 30% when a 30 deg angular resolution was explored instead of 15 deg. Measurements were fast and repeatable under the same experimental conditions. Size and shape parameters showed the highest consistency, whereas location and irregularity parameters showed lower consistency. The system was sensitive to changes in the intensity of the central glare source but not to pupil changes in this sample of healthy subjects.
Resumo:
METHODS: Refractive lens exchange was performed with implantation of an AT Lisa 839M (trifocal) or 909MP (bifocal toric) IOL, the latter if corneal astigmatism was more than 0.75 diopter (D). The postoperative visual and refractive outcomes were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. A control group of eyes in which a Tecnis ZCB00 1-piece monofocal IOL was implanted had the same examinations. RESULTS: A trifocal or bifocal toric IOL was implanted in 66 eyes. The control IOL was implanted in 18 eyes. All 3 groups obtained a significant improvement in uncorrected distance visual acuity (UDVA) (P < .001) and corrected distance visual acuity (CDVA) (P Z .001). The mean uncorrected near visual acuity (UNVA) was 0.123 logMAR with the trifocal IOL and 0.130 logMAR with the bifocal toric IOL. The residual refractive cylinder was less than 1.00 D in 86.7% of cases with the toric IOL. The mean light-distortion index was significantly higher in the multifocal IOL groups than in the monofocal group (P < .001), although no correlation was found between the light-distortion index and CDVA. CONCLUSIONS: The multifocal IOLs provided excellent UDVA and functional UNVA despite increased light-distortion indices. The light-distortion analyzer reliably quantified a subjective component of vision distinct from visual acuity; it may become a useful adjunct in the evaluation of visual quality obtained with multifocal IOLs.