17 resultados para WHITE-LIGHT

em Universidade do Minho


Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this work, Ba0.8Sr0.2TiO3 (BST)/ITO structures were grown on glass substrate and laser assisted annealing (LAA) was performed to promote the crystallization of BST. Atomic force microscopy and X-ray diffraction studies confirm the crack free and polycrystalline perovskite phase of BST. White light controlled resistive switching (RS) effect in Au/BST/ITO device is investigated. The device displays the electroforming-free bipolar RS characteristics and are explained by the modulationof the width and height of barrier at the BST/ITO interface via ferroelectric polarization. Moreover, the RS effect is signifi- cantly improved under white light illumination compared to that in the dark. The enhanced RS and photovoltaic effects are explained by considering depolarization field and charge distribution at the interface. The devices exhibit stable retention characteristics with low currents (mA), which make them attractive for non volatile memory devices.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tese de Doutoramento em Medicina

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Biopolymer-based materials have been of particular interest as alternatives do synthetic polymers due to their low toxicity, biodegradability and biocompatibility. Among them, chitosan is one of the most studied ones and has recently been investigated for the application as solid state polymer electrolytes. Furthermore, it can serve as a host for luminescent species such as rare earth ions, giving rise to materials with increased functionality, of particular interest for electrochemical devices. In this study, we investigate chitosan based luminescent materials doped wit Eu3+ and Li+ triflate salts from the structural, photophysical and conductivity points of view. Because the host presents a broad emission band in the blue to green, while Eu3+ emits in the red, fine tuning of emission colour and/or generation of white light is possible by optimizing composition and excitation scheme. Europium lifetimes (5D0) are in the range 270 – 350 µs and quantum yields are as high as 2%. Although Li+ does not interfere with the luminescent properties, it grants ion-conducting properties to the material suggesting that a combination of both properties could be further explored in multifunctional device.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tese de Doutoramento em Engenharia Eletrónica e de Computadores.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background and aim: A significant proportion of patients presenting with obscure gastrointestinal bleeding (OGIB) have negative small bowel capsule endoscopy (SBCE) examinations, and yet remain at risk of rebleeding. We aimed to evaluate whether a second-look review of SBCE images using flexible spectral color enhancement (FICE) may improve the detection of potentially bleeding lesions. Materials and methods: This was a retrospective, single-center study including consecutive patients with OGIB subjected to SBCE, whose standard white light examination was nondiagnostic. Each SBCE was reviewed using FICE 1. New findings were labeled as either P1 or P2 lesions according to bleeding potential. Patients were followed up to assess the incidence of rebleeding. Results: A total of 42 consecutive patients were included. Sixteen patients (38%) experienced rebleeding after a mean follow-up of 26 months. Review of SBCE images using FICE 1 enabled the identification of previously unrecognized P2 lesions, mainly angioectasias, in nine patients (21%) and P1 lesions, mainly erosions, in 26 patients (62%). Among patients who experienced rebleeding, 13/16 (81%) were diagnosed with P1 lesions with FICE 1 (P=0.043), whereas 3/16 (19%) had confirmed nondiagnostic SBCE and only 1/16 (6%) had newly diagnosed P2 (plus P1) lesions. An alternative source of bleeding outside the small bowel was found in only 3/16 (19%) patients with rebleeding during the follow-up. Conclusion: In a significant proportion of patients with OGIB, FICE 1 may detect potentially bleeding lesions previously missed under conventional white light SBCE. Review of nondiagnostic SBCE with FICE 1 may be a valuable strategy to obviate the need for further investigations in patients with OGIB, particularly for those who experience rebleeding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento em Ciências - Especialidade em Biologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[Excerpt] Synchronization of periodic movements like side-by-side walking [7] is frequently modeled by coupled oscillators [5] and the coupling strength is defined quantitatively [3]. In contrast, in most studies on sensorimotor synchronization (SMS), simple movements like finger taps are synchronized with simple stimuli like metronomes [4]. While the latter paradigm simplifies matters and allows for the assessment of the relative weights of sensory modalities through systematic variation of the stimuli [1], it might lack ecological validity. Conversely, using more complex movements and stimuli might complicate the specification of mechanisms underlying coupling. We merged the positive aspects of both approaches to study the contribution of auditory and visual information on synchronization during side-by-side walking. As stimuli, we used Point Light Walkers (PLWs) and auralized steps sound; both were constructed from previously captured walking individuals [2][6]. PLWs were retro-projected on a screen and matched according to gender, hip height, and velocity. The participant walked for 7.20m side by side with 1) a PLW, 2) steps sound, or 3) both displayed in temporal congruence. Instruction to participants was to synchronize with the available stimuli. [...]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We theoretically investigate light propagation and Anderson localization in one-dimensional disordered superlattices composed of dielectric stacks with graphene sheets in between. Disorder is introduced either on graphene material parameters ({\it e.g.} Fermi energy) or on the widths of the dielectric stacks. We derive an analytic expression for the localization length $\xi$, and compare it to numerical simulations using transfer matrix technique; a very good agreement is found. We demonstrate that the presence of graphene may strongly attenuate the anomalously delocalised Breswter modes, and is at the origin of a periodic dependence of $\xi$ on frequency, in contrast to the usual asymptotic decay, $\xi \propto \omega^{-2}$. By unveiling the effects of graphene on Anderson localization of light, we pave the way for new applications of graphene-based, disordered photonic devices in the THz spectral range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Artigo completo publicado na revista "BioMed Research International, (2015), 1-7" e disponível no RepositóriUM em: http://hdl.handle.net/1822/33375

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our objective was to validate a new device dedicated to measure the light disturbances surrounding bright sources of light under different sources of potential variability. Twenty subjects were involved in the study. Light distortion was measured using an experimental prototype (light distortion analyzer, CEORLab, University of Minho, Portugal) comprising twenty-four LED arrays panel at 2 m. Sources of variability included: intrasession and intersession repeated measures, pupil size (3 versus 6 mm), defocus (þ0.50) correction for the working distance, angular resolution (15 deg versus 30 deg), temporal stimuli presentation, and pupil size. Size, shape, location, and irregularity parameters have been obtained. At a low speed of presentation of the stimuli, changes in angular resolution did not have an effect on the results of the parameters measured. Results did not change with pupil size. Intensity of the central glare source significantly influenced the outcomes. Examination time was reduced by 30% when a 30 deg angular resolution was explored instead of 15 deg. Measurements were fast and repeatable under the same experimental conditions. Size and shape parameters showed the highest consistency, whereas location and irregularity parameters showed lower consistency. The system was sensitive to changes in the intensity of the central glare source but not to pupil changes in this sample of healthy subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

METHODS: Refractive lens exchange was performed with implantation of an AT Lisa 839M (trifocal) or 909MP (bifocal toric) IOL, the latter if corneal astigmatism was more than 0.75 diopter (D). The postoperative visual and refractive outcomes were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. A control group of eyes in which a Tecnis ZCB00 1-piece monofocal IOL was implanted had the same examinations. RESULTS: A trifocal or bifocal toric IOL was implanted in 66 eyes. The control IOL was implanted in 18 eyes. All 3 groups obtained a significant improvement in uncorrected distance visual acuity (UDVA) (P < .001) and corrected distance visual acuity (CDVA) (P Z .001). The mean uncorrected near visual acuity (UNVA) was 0.123 logMAR with the trifocal IOL and 0.130 logMAR with the bifocal toric IOL. The residual refractive cylinder was less than 1.00 D in 86.7% of cases with the toric IOL. The mean light-distortion index was significantly higher in the multifocal IOL groups than in the monofocal group (P < .001), although no correlation was found between the light-distortion index and CDVA. CONCLUSIONS: The multifocal IOLs provided excellent UDVA and functional UNVA despite increased light-distortion indices. The light-distortion analyzer reliably quantified a subjective component of vision distinct from visual acuity; it may become a useful adjunct in the evaluation of visual quality obtained with multifocal IOLs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study is to explore obsessive-compulsive disorder (OCD)-related abnormalities in white matter connectivity in OCD for a core region associated with inhibitory control [i.e. inferior frontal gyrus (IFG)]. Fifteen patients with OCD (11 men) and 15 healthy controls (nine men) underwent diffusion tensor imaging scanning to study four diffusivity indexes of white matter integrity [fractional anisotropy, mean diffusivity (MD), axial diffusivity and radial diffusivity (RD)]. The results showed that persons with OCD manifested significantly lower fractional anisotropy levels in the bilateral IFG as well as its parcellations in the pars opercularis, pars triangularis, and pars orbitalis. Significantly higher levels of MD, RD were evident for the OCD group in the IFG as a whole as well as in the bilateral subregions of the pars triangularis and pars opercularis (for MD and RD), the right side of the pars orbitalis (for RD), and the left side of the pars triangularis and right side pars opercularis (for axial diffusivity). Overall, the results suggest significant alterations in structural connectivity, probably associated with myelination and axonal abnormalities in the IFG of OCD patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a search for Higgs bosons decaying to four leptons, either electrons or muons, via one or two light exotic gauge bosons Zd, H→ZZd→4ℓ or H→ZdZd→4ℓ. The search was performed using pp collision data corresponding to an integrated luminosity of about 20 fb−1 at the center-of-mass energy of s√=8TeV recorded with the ATLAS detector at the Large Hadron Collider. The observed data are well described by the Standard Model prediction. Upper bounds on the branching ratio of H→ZZd→4ℓ and on the kinetic mixing parameter between the Zd and the Standard Model hypercharge gauge boson are set in the range (1--9)×10−5 and (4--17)×10−2 respectively, at 95% confidence level assuming the Standard Model branching ratio of H→ZZ∗→4ℓ, for Zd masses between 15 and 55 GeV. Upper bounds on the effective mass mixing parameter between the Z and the Zd are also set using the branching ratio limits in the H→ZZd→4ℓ search, and are in the range (1.5--8.7)×10−4 for 15

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multilayer systems obtained using the Layer-by-Layer (LbL) technology have been proposed for a variety of biomedical applications in tissue engineering and regenerative medicine. LbL assembly is a simple and highly versatile method to modify surfaces and fabricate robust and highly-ordered nanostructured coatings over almost any type of substrates and with a wide range of substances. The incorporation of polyoxometalate (POM) inorganic salts as constituents of the layers presents a possibility of promoting light-stimuli responses in LbL substrates. We propose the design of a biocompatible photo-responsive multilayer system based on a Preyssler-type POM ([NaP5W30O110]14â ) and a natural origin polymer, chitosan, using the LbL methodology. The photo-reduction properties of the POM allow the spatially controlled disruption of the assembled layers due to the weakening of the electrostatic interactions between the layers. This system has found applicability in detaching devices, such as the cell sheet technology, which may solve the drawbacks actually found in other cell treatment proposals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mycotoxins are toxic secondary metabolites produced by certain moulds, being ochratoxin A (OTA) one of the most relevant. Its chemical structure is a dihydro-isocoumarin connected at the 7-carboxy group to a molecule of L--phenylalanine via an amide bond. OTA contamination of wines might be a risk to consumer health, thus requiring treatments to achieve acceptable standards for human consumption [1]. According to the Regulation No. 1881/2006 of the European Commission, the maximum limit for OTA in wine is 2 µg/kg [2]. Therefore, the aim of this work was to know the effect of different fining agents on OTA removal, as well as their impact on white and red wine physicochemical characteristics. To evaluate their efficiency, 11 commercial fining agents (mineral, synthetic, animal and vegetable proteins) were used to get new approaches on OTA removal from white and red wines. Trials were performed in wines artificially supplemented (at a final concentration of 10 µg/L) with OTA. The most effective fining agent in removing OTA (80%) from white wine was a commercial formulation that contains gelatine, bentonite and activated carbon. Removals between 10-30% were obtained with potassium caseinate, yeast cell walls and pea protein. With bentonites, carboxymethylcellulose, polyvinylpolypyrrolidone and chitosan no considerable OTA removal was verified. In red wine, removals between 6-19% were obtained with egg albumin, yeast cell walls, pea protein, isinglass, gelatine, polyvinylpolypyrrolidone and chitosan. The most effective fining agents in removing OTA from red wine were an activated carbon (66%) followed again by the commercial formulation (55%), being activated carbon a well-known adsorbent of mycotoxins. These results may provide useful information for winemakers, namely for the selection of the most appropriate oenological product for OTA removal, reducing wine toxicity and simultaneously enhancing food safety and wine quality.