Bidirectional battery charger with grid-to-vehicle, vehicle-to-grid and vehicle-to-home technologies
Resumo:
This paper presents the development of na on-board bidirectional battery charger for Electric Vehicles (EVs) targeting Grid-to-Vehicle (G2V), Vehicle-to-Grid (V2G), and Vehicle-to-Home (V2H) technologies. During the G2V operation mode the batteries are charged from the power grid with sinusoidal current and unitary power factor. During the V2G operation mode the energy stored in the batteries can be delivered back to the power grid contributing to the power system stability. In the V2H operation mode the energy stored in the batteries can be used to supply home loads during power outages, or to supply loads in places without connection to the power grid. Along the paper the hardware topology of the bidirectional battery charger is presented and the control algorithms are explained. Some considerations about the sizing of the AC side passive filter are taken into account in order to improve the performance in the three operation modes. The adopted topology and control algorithms are accessed through computer simulations and validated by experimental results achieved with a developed laboratory prototype operating in the different scenarios.
Resumo:
Solar photovoltaic systems are an increasing option for electricity production, since they produce electrical energy from a clean renewable energy resource, and over the years, as a result of the research, their efficiency has been increasing. For the interface between the dc photovoltaic solar array and the ac electrical grid is necessary the use of an inverter (dc-ac converter), which should be optimized to extract the maximum power from the photovoltaic solar array. In this paper is presented a solution based on a current-source inverter (CSI) using continuous control set model predictive control (CCS-MPC). All the power circuits and respective control systems are described in detail along the paper and were tested and validated performing computer simulations. The paper shows the simulation results and are drawn several conclusions.
Resumo:
This paper presents a comprehensive comparison of a current-source converter and a voltage-source converter for three-phase electric vehicle (EV) fast battery chargers. Taking into account that the current-source converter (CSC) is a natural buck-type converter, the output voltage can assume a wide range of values, which varies between zero and the maximum instantaneous value of the power grid phase-to-phase voltage. On the other hand, taking into account that the voltage-source converter (VSC) is a natural boost-type converter, the output voltage is always greater than the maximum instantaneous value of the power grid phase-to-phase voltage, and consequently, it is necessary to use a dc-dc buck-type converter for applications as EV fast battery chargers. Along the paper is described in detail the principle of operation of both the CSC and the VSC for EV fast chargers, as well as the main equations of the power theory and current control strategies. The comparison between both converters is mainly established in terms of the total harmonic distortion of the grid current and the estimated efficiency for a range of operation between 10 kW and 50 kW.
Resumo:
Tese de Doutoramento - Programa Doutoral em Engenharia Industrial e Sistemas (PDEIS)
Resumo:
This study focuses on the prospective mediation role of family coping between burden and cortisol levels in informal caregivers of addicts as well as on the feasible use of two different ways to analyse the salivary cortisol levels. Participants were 120 Portuguese informal caregivers of addicts. The cortisol samples were collected at awakening, 45 minutes later and after a 30 minute presentation of images taken from the International Affective Picture System. Family coping and caregiver burden were measured using the Portuguese versions of the Caregiver Reaction Assessment, and the Family Crisis Oriented Personal Evaluation Scale. Cortisol samples were collected in salivettes and the results were computed in order to determine the Area Under the Curve scores (AUCg, AUCi). Results found family coping to be negatively correlated with burden and AUCg levels (i.e. overall intensity) and positively correlated with either AUCg and AUCi (i.e. change over time). The mediation model revealed that family coping was a partial mediator in the relationship between the burden and AUCg levels. Therefore, Family Coping appears to be an essential variable in understanding the stress response and should be considered in further studies and interventions. In addition, the use of two different formulas for calculating cortisol levels provided important new information concerning the relationship between cortisol, burden and family coping. It seems that burden has a more profound effect on the overall intensity of the neuroendocrine response to caregiver stress and not so much on the sensitivity of the system.
Resumo:
Dissertação de mestrado integrado em Engenharia Mecânica