15 resultados para TECHNOLOGY DEVELOPMENT
em Universidade do Minho
Resumo:
Musculoskeletal diseases are one of the leading causes of disability worldwide. Tendon injuries are responsible for substantial morbidity, pain and disability. Tissue engineering strategies aim at translating tendon structure into biomimetic materials. The main goal of the present study is to develop microengineered hydrogel fibers through the combination of microfabrication and chemical interactions between oppositely charged polyelectrolytes. For this, methacrylated hyaluronic acid (MeHA) and chondroitin sulfate (MeCS) were combined with chitosan (CHT). Hydrogel fibers were obtained by injecting polymer solutions (either MeHA or MeHA/MeCS and CHT) in separate microchannels that join at a y-junction, with the materials interacting upon contact at the interface. To evaluate cell behavior, human tendon derived cells (hTDCs) were isolated from tendon surplus samples during orthopedic surgeries and seeded on top of the fibers. hTDCs adhered to the surface of the fibers, remaining viable, and were found to be expressing CD44, the receptor for hyaluronic acid. The synthesis of hydrogel fibers crosslinkable through both physical and chemical mechanisms combined with microfabrication technology allows the development of biomimetic structures with parallel fibers being formed towards the replication of tendon tissue architecture.
Resumo:
The present work aimed to assess the early-age evolution of E-modulus of epoxy adhesives used for Fibre-Reinforced Polymer (FRP) strengthening applications. The study involved adapting an existing technique devised for continuous monitoring of concrete stiffness since casting, called EMM-ARM (Elasticity Modulus Measurement through Ambient Response Method) for evaluation of epoxy stiffness. Furthermore, monotonic tensile tests according to ISO standards and cyclic tensile tests were carried out at several ages. A comparison between the obtained results was performed in order to better understand the performance of the several techniques in the assessment of stiffness of epoxy resins. When compared to the other methodologies, the method for calculation of E-modulus recommended by ISO standard led to lower values, since in the considered strain interval, the adhesive had a non-linear stress–strain relationship. The EMM-ARM technique revealed its capability in clearly identifying the hardening kinetics of epoxy adhesives, measuring the material stiffness growth during the entire curing period. At very early ages the values of Young׳s modulus obtained with quasi-static tests were lower than the values collected by EMM-ARM, due to the fact that epoxy resin exhibited a significant visco-elastic behaviour.
Resumo:
Supplementary information available at: http://www.rsc.org/suppdata/c5/gc/c5gc02231b/c5gc02231b1.pdf
Resumo:
Childhood is a central period for career and social-emotional development. However, the literature covering childhood career development and the role of emotions in careers is scarce. In this article, we advocate for the consideration of emotions in childhood career development. Emotional aspects of children’s career exploration, key-figures and interests, as well as of childhood antecedents of lifelong career processes are presented. Relations between childhood emotion, behavior, functioning and learning are also presented. Conclusions center on a call for focused study of the role of emotion in childhood career development and how such an agenda will advance the literature.
Resumo:
Institutional rearing adversely affects children’s development, but the extent to which specific characteristics of the institutional context and the quality of care provided contribute to problematic development remains unclear. In this study, 72 preschoolers institutionalised for at least 6 months were evaluated by their caregiver using the Child Behavior Checklist and the Disturbances of Attachment Interview. Distal and proximate indices of institutional caregiving quality were assessed using both staff reports and direct observation. Results revealed that greater caregiver sensitivity predicted reduced indiscriminate behaviour and secure-base distortions. A closer relationship with the caregiver predicted reduced inhibited attachment behaviour. Emotional and behavioural problems proved unrelated to caregiving quality. Results are discussed in terms of (non)-shared caregiving factors that influence institutionalised children’s development.
Resumo:
Magnetoelectric microspheres based on piezoelectric poly(vinylidene fluoride) (PVDF) and magnetrostrictive CoFe2O4 (CFO), a novel morphology for polymer-based ME material, have been developed by an electrospray process. The CFO nanoparticles content in the (3-7 μm diameter) microspheres reaches values up to 27 wt.%, despite their concentration in the starting solution reaching values up to 70 wt.%. Additionally, the inclusion of magnetostrictive nanoparticles into the polymer spheres has no relevant effect on the piezoelectric β-phase content (≈60%), crystallinity (40%) and the onset degradation temperature (460º-465ºC) of the polymer matrix. The multiferroic microspeheres show a maximum piezoelectric reponse |d33|≈30 pC.N-1, leading to a magnetoelectric response of Δ|d33|≈5 pC.N-1 obtained when a 220 mT DC magnetic field was applied. It is also shown that the interface between CFO nanoparticles and PVDF (from 0 to 55%) has a strong influence on the ME response of the microspheres. The simplicity and the scalability of the processing method suggest a large application potential of this novel magnetoelectric geometry in areas such as tissue engineering, sensors and actuators.
Resumo:
Tese de Doutoramento Ciência e Engenharia de Polímeros e Compósitos.
Resumo:
The research of stereotactic apparatus to guide surgical devices began in 1908, yet a major part of today's stereotactic neurosurgeries still rely on stereotactic frames developed almost half a century ago. Robots excel at handling spatial information, and are, thus, obvious candidates in the guidance of instrumentation along precisely planned trajectories. In this review, we introduce the concept of stereotaxy and describe a standard stereotactic neurosurgery. Neurosurgeons' expectations and demands regarding the role of robots as assistive tools are also addressed. We list the most successful robotic systems developed specifically for or capable of executing stereotactic neurosurgery. A critical review is presented for each robotic system, emphasizing the differences between them and detailing positive features and drawbacks. An analysis of the listed robotic system features is also undertaken, in the context of robotic application in stereotactic neurosurgery. Finally, we discuss the current perspective, and future directions of a robotic technology in this field. All robotic systems follow a very similar and structured workflow despite the technical differences that set them apart. No system unequivocally stands out as an absolute best. The trend of technological progress is pointing toward the development of miniaturized cost-effective solutions with more intuitive interfaces.
Resumo:
Dissertação de mestrado em Engenharia Industrial
Resumo:
Tese de Doutoramento em Ciências da Educação (Especialidade de Tecnologia Educativa)
Resumo:
Programa Doutoral em Engenharia Biomédica
Resumo:
Tese de Doutoramento em Biologia Molecular e Ambiental - Especialidade em Biologia Celular e Saúde
Resumo:
Tese de Doutoramento (Programa Doutoral em Engenharia de Materiais)
Resumo:
Personalized tissue engineering and regenerative medicine (TERM) therapies propose patient-oriented effective solutions, considering individual needs. Cell-based therapies, for example, may benefit from cell sources that enable easier autologous set-ups or from recent developments on IPS cells technologies towards effective personalized therapeutics. Furthermore, the customization of scaffold materials to perfectly fit a patientâ s tissue defect through rapid prototyping technologies, also known as 3D printing, is now a reality. Nevertheless, the timing to expand cells or to obtain functional in vitrotissue substitutes prior to implantation prevents advancements towards routine use upon patient´s needs. Thus, personalized therapies also anticipate the importance of creating off-the-shelf solutions to enable immediately available tissue engineered products. This paper reviews the main recent developments and future challenges to enable personalized TERM approaches and to bring these technologies closer to clinical applications.
Resumo:
Background: Maternal depression is a worldwide phenomenon that has been linked to adverse developmental outcomes in neonates. Aims: To study the effect of antenatal depression (during the third trimester of pregnancy) on neonate behavior, preference, and habituation to both the mother and a stranger’s face/voice. To analyze mother’s depression at childbirth as a potential mediator or moderator of the relationship between antenatal depression and neonate behavioral development. Method: A sample of 110 pregnant women was divided in 2 groups according to their scores on the Edinburgh Postnatal Depression Scale during pregnancy (EPDS; ≥10, depressed; <10, non-depressed). In the first 5 days after birth, neonatal performance on the Neonatal Behavioral Assessment Scale (NBAS) and in the ‘Preference and habituation to the mother’s face/voice versus stranger’ paradigm was assessed; each mother filled out an EPDS. Results: Neonates of depressed pregnant women, achieved lower scores on the NBASs (regulation of state, range of state, and habituation); did not show a visual/auditory preference for the mother’s face/voice; required more trials to become habituated to the mother’s face/voice; and showed a higher visual/auditory preference for the stranger’s face/voice after habituation compared to neonates of non-depressed pregnant women. Depression at childbirth does not contribute to the effect of antenatal depression on neonatal behavioral development. Conclusion: Depression even before childbirth compromises the neonatal behavioral development. Depression is a relevant issue and should be addressed as a routine part of prenatal health care.