7 resultados para Shell-and-tube heat exchanger
em Universidade do Minho
Resumo:
Dissertação de mestrado integrado em Engenharia Mecânica
Resumo:
Particulate fouling tests were carried out using kaolin-water suspensions flowing through an annular heat exchanger with a copper inner tube. The flow rate was changed from test to test, but the fluid temperature and pH, as well as the particle concentration, were maintained constant. In the lower range of fluid velocities (<0.5 m/s), the deposition process seemed to be controlled by mass transfer. The corresponding experimental transport fluxes were compared to the predictions obtained with several models, showing that diffusion governed particle transport. The absolute values of the mass transfer fluxes and their dependences on the Reynolds number were satisfactorily predicted by some of the models.
Resumo:
Purpose: To study the relationship among the variables intensity ofthe end-of-day (EOD) dryness, corneal sensitivity and blink rate in soft contact lens (CL) wearers. Methods: Thirty-eight soft CL wearers (25 women and 13 men; mean age 27.1 ± 7.2 years) were enrolled. EOD dryness was assessed using a scale of 0–5 (0, none to 5, very intense). Mechanical and thermal (heat and cold) sensitivity were measured using a Belmonte’s gas esthesiometer. The blink rate was recorded using a video camera while subjects were wearing a hydrogel CL and watching a film for 90 min in a controlled environmental chamber. Results: A significant inverse correlation was found between EOD dryness and mechanical sensitivity (r: −0.39; p = 0.02); however, there were no significant correlations between EOD dryness and thermal sensitivity. A significant (r: 0.56; p < 0.001) correlation also was observed between EOD dryness and blink rate, but no correlations were found between blink rate and mechanical or thermal sensitivity. Conclusions: CL wearers with higher corneal sensitivity to mechanical stimulation reported more EOD dryness with habitual CL wear. Moreover, subjects reporting more EOD dryness had an increased blink rates during wear of a standard CL type. The increased blink rate could act to improve the ocular surface environment and relieve symptoms
Resumo:
The synthesis and biological evaluation of novel 1-aryl-3-[2-, 3- or 4-(thieno[3,2-b]pyridin-7-ylthio)phenyl]ureas 3, 4 and 5 as VEGFR-2 tyrosine kinase inhibitors, are reported. The 1-aryl-3-[3-(thieno[3,2-b]pyridin-7-ylthio)phenyl]ureas 4a-4h, with the arylurea in the meta position to the thioether, showed the lowest IC50 values in enzymatic assays (10-206 nM), the most potent compounds 4d-4h (IC50 10-28 nM) bearing hydrophobic groups (Me, F, CF3 and Cl) in the terminal phenyl ring. A convincing rationalization was achieved for the highest potent compounds 4 as type II VEGFR-2 inhibitors, based on the simultaneous presence of: (1) the thioether linker and (2) the arylurea moiety in the meta position. For compounds 4, significant inhibition of Human Umbilical Vein Endothelial Cells (HUVECs) proliferation (BrdU assay), migration (wound-healing assay) and tube formation were observed at low concentrations. These compounds have also shown to increase apoptosis using the TUNEL assay. Immunostaining for total and phosphorylated (active) VEGFR-2 was performed by Western blotting. The phosphorylation of the receptor was significantly inhibited at 1.0 and 2.5 microM for the most promising compounds. Altogether, these findings point to an antiangiogenic effect in HUVECs.
Resumo:
Glazing is a technique used to retard fish deterioration during storage. This work focuses on the study of distinct variables (fish temperature, coating temperature, dipping time) that affect the thickness of edible coatings (water glazing and 1.5% chitosan) applied on frozen fish. Samples of frozen Atlantic salmon (Salmo salar) at -15, -20, and -25 °C were either glazed with water at 0.5, 1.5 or 2.5 °C or coated with 1.5% chitosan solution at 2.5, 5 or 8 °C, by dipping during 10 to 60 s. For both water and chitosan coatings, lowering the salmon and coating solution temperatures resulted in an increase of coating thickness. At the same conditions, higher thickness values were obtained when using chitosan (max. thickness of 1.41±0.05 mm) compared to water (max. thickness of 0.84±0.03 mm). Freezing temperature and crystallization heat were found to be lower for 1.5% chitosan solution than for water, thus favoring phase change. Salmon temperature profiles allowed determining, for different dipping conditions, whether the salmon temperature was within food safety standards to prevent the growth of pathogenic microorganisms. The concept of safe dipping time is proposed to define how long a frozen product can be dipped into a solution without the temperature raising to a point where it can constitute a hazard.
Resumo:
Dissertação de mestrado integrado em Engenharia de Materiais
Resumo:
Dissertação de mestrado em Engenharia de Materiais