10 resultados para Rural peripheral
em Universidade do Minho
Resumo:
Relatório de atividade profissional de mestrado em Ensino de Educação Física nos Ensinos Básico e Secundário
Resumo:
Purpose. The purpose of this work was to evaluate the potential of a novel custom-designed rigid gas permeable (RGP) contact lens to modify the relative peripheral refractive error in a sample of myopic patients. Methods. Fifty-two right eyes of 52 myopic patients (mean [TSD] age, 21 [T2] years) with spherical refractive errors ranging from j0.75 to j8.00 diopters (D) and refractive astigmatism of 1.00 D or less were fitted with a novel experimental RGP (ExpRGP) lens designed to create myopic defocus in the peripheral retina. A standard RGP (StdRGP) lens was used as a control in the same eye. The relative peripheral refractive error was measured without the lens and with each of two lenses (StdRGP and ExpRGP) using an open-field autorefractometer from 30 degrees nasal to 30 degrees temporal, in 5-degree steps. The effectiveness of the lens design was evaluated as the amount of relative peripheral refractive error difference induced by the ExpRGP compared with no lens and with StdRGP conditions at 30 degrees in the nasal and temporal (averaged) peripheral visual fields. Results. Experimental RGP lens induced a significant change in relative peripheral refractive error compared with the nolens condition (baseline), beyond the 10 degrees of eccentricity to the nasal and temporal side of the visual field (p G 0.05). The maximum effect was achieved at 30 degrees. Wearing the ExpRGP lens, 60% of the eyes had peripheral myopia exceeding j1.00 D, whereas none of the eyes presented with this feature at baseline. There was no significant correlation (r = 0.04; p = 0.756) between the degree of myopia induced at 30 degrees of eccentricity of the visual field with the ExpRGP lens and the baseline refractive error. Conclusions. Custom-designed RGP contact lenses can generate a significant degree of relative peripheral myopia in myopic patients regardless of their baselin spherical equivalent refractive error.
Resumo:
Purpose: To evaluate the impact of eye and head rotation in the measurement of peripheral refraction with an open-field autorefractometer in myopic eyes wearing two different center-distance designs of multifocal contact lenses (MFCLs). Methods: Nineteen right eyes from 19 myopic patients (average central M ± SD = −2.67 ± 1.66 D) aged 20–27 years (mean ± SD = 23.2 ± 3.3 years) were evaluated using a Grand-Seiko autorefractometer. Patients were fitted with one multifocal aspheric center-distance contact lens (Biofinity Multifocal D®) and with one multi-concentric MFCL (Acuvue Oasys for Presbyopia). Axial and peripheral refraction were evaluated by eye rotation and by head rotation under naked eye condition and with each MFCL fitted randomly and in independent sessions. Results: For the naked eye, refractive pattern (M, J0 and J45) across the central 60◦ of the horizontal visual field values did not show significant changes measured by rotating the eye or rotating the head (p > 0.05). Similar results were obtained wearing the Biofinity D, for both testing methods, no obtaining significant differences to M, J0 and J45 values (p > 0.05). For Acuvue Oasys for presbyopia, also no differences were found when comparing measurements obtained by eye and head rotation (p > 0.05). Multivariate analysis did not showed a significant interaction between testing method and lens type neither with measuring locations (MANOVA, p > 0.05). There were significant differences in M and J0 values between naked eyes and each MFCL. Conclusion: Measurements of peripheral refraction by rotating the eye or rotating the head in myopic patients wearing dominant design or multi-concentric multifocal silicone hydrogel contact lens are comparable.
Resumo:
Objective. To evaluate the degree of axial elongation with soft radial refractive gradient (SRRG) contact lenses, orthokeratology (OK), and single vision (SV) spectacle lenses (control) during a period of 1 year before treatment and 2 years after treatment. Methods. This was a prospective, longitudinal, nonrandomized study. The study groups consisted of 30, 29, and 41 children, respectively. The axial length (AL) was measured during 2 years after recruitment and lens fitting. Results. The baseline refractive sphere was correlated significantly (r 2 = 0.542; P < 0.0001) with the amount of myopia progression before baseline. After 2 years, the mean myopia progression values for the SRRG, OK, and SV groups were −0.56 ± 0.51, −0.32 ± 0.53, and −0.98 ± 0.58 diopter, respectively. The results represent reductions in myopic progression of 43% and 67% for the SRRG and OK groups, respectively, compared to the SV group. The AL increased more in the SV group compared to the SRRG and OK groups, with 27% and 38% lower axial elongation, respectively, compared to the SV group at the 2-year visit (P < 0.05). SRRG and OK showed no differences (P = 0.430). Conclusion. The SRRG lens significantly decreased AL elongation compared to the SV control group. The SRRG lens was similarly effective to OK in preventing myopia progression in myopic children and adolescent.
Resumo:
Purpose: The purpose of this study was to evaluate the effect of orthokeratology for different degrees of myopia correction in the relative location of tangential (FT) and sagittal (FS) power errors across the central 70 of the visual field in the horizontal meridian. Methods: Thirty-four right eyes of 34 patients with a mean age of 25.2 ± 6.4 years were fitted with Paragon CRT (Mesa, AZ) rigid gas permeable contact lenses to treat myopia (2.15 ± 1.26D, range: 0.88 to 5.25D). Axial and peripheral refraction were measured along the central 70 of the horizontal visual field with the Grand Seiko WAM5500 open-field auto-refractor. Spherical equivalent (M), as well as tangential (FT) and sagittal power errors (FS) were obtained. Analysis was stratified in three groups according to baseline spherical equivalent: Group 1 [MBaseline = 0.88 to 1.50D; n = 11], Group 2 [MBaseline = 1.51 to 2.49D; n = 11], and Group 3 [MBaseline = 2.50 to 5.25D; n = 12]. Results: Spherical equivalent was significantly more myopic after treatment beyond the central 40 of the visual field (p50.001). FT became significantly more myopic for all groups in the nasal and temporal retina with 25 (p 0.017), 30 (p 0.007) and 35 (p 0.004) of eye rotation. Myopic change in FS was less consistent, achieving only statistical significance for all groups at 35 in the nasal and temporal retina (p 0.045). Conclusions: Orthokeratology changes significantly FT in the myopic direction beyond the central 40 of the visual field for all degrees of myopia. Changes induced by orthokeratology in relative peripheral M, FT and FS with 35 of eye rotation were significantly correlated with axial myopia at baseline. Keywords: Field
Resumo:
The use of construction and demolition waste (C&DW) in the construction industry is an important contribution to attain sustainability in the sector. The roads are among the civil engineering works which can use larger quantities of C&DW recycled aggregates. In Portugal, the limit values for the properties of C&DW recycled aggregates that can be used in the roads of Portuguese Road Network are defined by two Laboratório Nacional de Engenharia Civil (LNEC) technical specifications (TS), in accordance to Portuguese Decree-law no. 46/2008 of May 12th. Municipal and rural roads and trenches have specific characteristics that can enable the use of C&DW of lower quality than those required by existing LNEC TS, and even then ensuring an adequate performance. However, given the absence of specific regulation for those applications, the Portuguese Environment Agency requires compliance with the existing LNEC TS, which represents an obstacle to recycling a significant part of the C&DW, in particular at a local government level. This paper presents guidelines for the recycling of C&DW in municipal and rural roads and in trenches, which could be considered in a new forthcoming LNEC TS. In the preparation of the guidelines, the bibliography collected and analysed, the information gathered from the application of C&DW in a municipal and rural roads of a Portuguese municipality and in the roadways of a Portuguese resort, and the results of laboratory tests carried out on samples collected in the Portuguese municipality were taken into consideration.
Resumo:
Tese de Doutoramento em Sociologia
Resumo:
The blood brain barrier (BBB) and the blood cerebrospinal fluid barrier (BCSFB) form the barriers of the brain. These barriers are essential not only for the protection of the brain, but also in regulating the exchange of cells and molecules in and out of the brain. The choroid plexus (CP) epithelial cells and the arachnoid membrane form the BCSFB. The CP is structurally divided into two independent compartments: one formed by a unique and continuous line of epithelial cells that rest upon a basal lamina; and, a second consisting of a central core formed by connective and highly vascularized tissue populated by diverse cell types (fibroblasts, macrophages and dendritic cells). Here, we review how the CP transcriptome and secretome vary depending on the nature and duration of the stimuli to which the CP is exposed. Specifically, when the peripheral stimulation is acute the CP response is rapid, strong and transient, whereas if the stimulation is sustained in time the CP response persists but it is weaker. Furthermore, not all of the epithelium responds at the same time to peripheral stimulation, suggesting the existence of a synchrony system between individual CP epithelial cells.
Resumo:
Relatório de mestrado em Ensino de Educação Física nos Ensinos Básico e Secundário