8 resultados para Qualitative Exchange
em Universidade do Minho
Resumo:
Polymer binder modification with inorganic nanomaterials (NM) could be a potential and efficient solution to control matrix flammability of polymer concrete (PC) materials without sacrificing other important properties. Occupational exposures can occur all along the life cycle of a NM and “nanoproducts” from research through scale-up, product development, manufacturing, and end of life. The main objective of the present study is to analyse and compare different qualitative risk assessment methods during the production of polymer mortars (PM) with NM. The laboratory scale production process was divided in 3 main phases (pre-production, production and post-production), which allow testing the assessment methods in different situations. The risk assessment involved in the manufacturing process of PM was made by using the qualitative analyses based on: French Agency for Food, Environmental and Occupational Health & Safety method (ANSES); Control Banding Nanotool (CB Nanotool); Ecole Polytechnique Fédérale de Lausanne method (EPFL); Guidance working safely with nanomaterials and nanoproducts (GWSNN); Istituto Superiore per la Prevenzione e la Sicurezza del Lavoro, Italy method (ISPESL); Precautionary Matrix for Synthetic Nanomaterials (PMSN); and Stoffenmanager Nano. It was verified that the different methods applied also produce different final results. In phases 1 and 3 the risk assessment tends to be classified as medium-high risk, while for phase 2 the more common result is medium level. It is necessary to improve the use of qualitative methods by defining narrow criteria for the methods selection for each assessed situation, bearing in mind that the uncertainties are also a relevant factor when dealing with the risk related to nanotechnologies field.
Resumo:
Tese de Doutoramento em Ciências da Educação (área de especialização em Tecnologia Educativa)
Resumo:
Tese de Doutoramento em Ciências da Educação - Especialidade de Desenvolvimento Curricular
Resumo:
Different metal-ion exchanged NaY zeolite, Na(M)Y, were used to prepare poly(vinylidene fluoride) based composites by solvent casting and melting crystallization. The effect of different metal ion-exchanged zeolites on polymer crystallization and electrical properties was reported. Cation-framework interactions and hydration energy of the cations determined that K+ is the most efficient exchanged ion in NaY zeolite, followed by Cs+ and Li+. The electroactive phase crystallization strongly depends on the ions present in the zeolite, leading to variations of the surface energy characteristics of the Na(M)Y zeolites and the polymer chain ability of penetration in the zeolite. Thus, Na(Li)Y and NaY induces the complete electroactive -phase crystallization of the crystalline phase of PVDF, while Na(K)Y only induces it partly and Na(Cs)Y is not able to promote the crystallization of the electroactive phase. Furthermore, different ion size/weigh and different interaction with the zeolite framework results in significant variations in the electrical response of the composite. In this way, iinterfacial polarization effects in the zeolite cavities and zeolite-polymer interface, leads to strong increases of the dielectric constant on the composites with lightest ions weakly bound to the zeolite framework. Polymer composite with Na(Li)Y show the highest dielectric response, followed by NaY and Na(K)Y. Zeolite Na(Cs)Y contribute to a decrease of the dielectric constant of the composite. The results show the relevance of the materials for sensor development.
Resumo:
METHODS: Refractive lens exchange was performed with implantation of an AT Lisa 839M (trifocal) or 909MP (bifocal toric) IOL, the latter if corneal astigmatism was more than 0.75 diopter (D). The postoperative visual and refractive outcomes were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. A control group of eyes in which a Tecnis ZCB00 1-piece monofocal IOL was implanted had the same examinations. RESULTS: A trifocal or bifocal toric IOL was implanted in 66 eyes. The control IOL was implanted in 18 eyes. All 3 groups obtained a significant improvement in uncorrected distance visual acuity (UDVA) (P < .001) and corrected distance visual acuity (CDVA) (P Z .001). The mean uncorrected near visual acuity (UNVA) was 0.123 logMAR with the trifocal IOL and 0.130 logMAR with the bifocal toric IOL. The residual refractive cylinder was less than 1.00 D in 86.7% of cases with the toric IOL. The mean light-distortion index was significantly higher in the multifocal IOL groups than in the monofocal group (P < .001), although no correlation was found between the light-distortion index and CDVA. CONCLUSIONS: The multifocal IOLs provided excellent UDVA and functional UNVA despite increased light-distortion indices. The light-distortion analyzer reliably quantified a subjective component of vision distinct from visual acuity; it may become a useful adjunct in the evaluation of visual quality obtained with multifocal IOLs.
Resumo:
Dissertação de mestrado em Estudos de Gestão
Resumo:
Tese de Doutoramento em Ciências da Educação (Especialidade de Tecnologia Educativa)
Resumo:
Background: Systematic knowledge on the factors that influence the decisions of IVF users regarding embryo donation for research is a core need for patient-centred policies and ethics in clinical practice. However, no systematic review has been provided on the motivations of patients who must decide embryo disposition. This paper fills this gap, presenting a systematic review of quantitative and qualitative studies, which synthesizes the current body of knowledge on the factors and reasons associated with IVF patients’ decisions to donate or not to donate embryos for research. Methods: A systematic search of studies indexed in PubMed, ISIWoK and PsycINFO, published before November 2013, was conducted. Only empirical, peer-reviewed, full-length, original studies reporting data on factors and reasons associated with the decision concerning donation or non-donation of embryos for research were included. Eligibility and data extraction were performed by two independent researchers and disagreements were resolved by discussion or a third reviewer, if required. The main quantitative findings were extracted and synthesized and qualitative data were assessed by thematic content analysis. Results: A total of 39 studies met the inclusion criteria and were included in the review. More than half of the studies (n ¼ 21) used a quantitative methodology, and the remaining were qualitative (n ¼ 15) or mixed-methods (n ¼ 3) studies. The studies were derived mainly from European countries (n ¼ 18) and the USA(n ¼ 11). The proportion of IVF users who donated embryos for research varied from 7% in a study in France to 73% in a Swiss study. Those who donate embryos for research reported feelings of reciprocity towards science and medicine, positive views of research and high levels of trust in the medical system. They described their decision as better than the destruction of embryos and as an opportunity to help others or to improve health and IVF treatments. The perception of risks, the lack of information concerning research projects and the medical system and the conceptualization of embryos in terms of personhood were the most relevant motives for not donating embryos for research. Results relating to the influence of sociodemographic characteristics and reproductive and gynaecological history were mostly inconclusive. Conclusions: Three iterative and dynamic dimensions of the IVF patients’ decision to donate or not to donate embryos for research emerged from this review: the hierarquization of the possible options regarding embryo disposition, according to the moral, social and instrumental status attributed to embryos; patients’ understanding of expectations and risks of the research on human embryos; and patients’ experiences of information exchange and levels of trust in the medical-scientific institutions.