18 resultados para QUT Corneal Nerve Grading Scale

em Universidade do Minho


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To evaluate neophyte contact lens wearers’ fitting to rigid gas permeable (RGP) contact lenses in terms of wearing time, tear volume, stability, corneal staining, and subjective ratings, over a 1-month period of time. Methods: Twenty-two young healthy subjects were enrolled for wearing RGP on a daily wear basis. The participants included in this study never wore contact lenses and showed a value under 10 in McMonnies Questionnaire. Contact Lens Dry Eye Questionnaire, Visual Analog Scales, Schirmer test, tear film break-up time (BUT), and corneal staining grading were performed. Follow-up visits were scheduled at 1, 7, 15, and 28 days. Results: Six subjects dropped out due to discomfort from the study before 1 month (27% of discontinuation rate). Successful RGP wearers (16 participants) achieved high levels of subjective vision and reported comfort scores of approximately 9 of 10 between 10 and 15 days. They reported wearing their lenses for an average of 10.1262.43 hr after 1 month of wear. Conversely, unsuccessful wearers discontinued wearing the lenses after the first 10 to 15 days, showing comfort scores and wearing time significantly lower compared with the first day of wear. Schirmer test showed a signifi- cant increase at 10 days (P,0.001), and the BUT trends decreased after the first week of wear in unsuccessful group. Conclusions: Symptomatology related with dryness and discomfort, detected during the first 10 days of the adaptation, may help the clinician to predict those participants who will potentially fail to adapt to RGP lens wear.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To study the relationship among the variables intensity ofthe end-of-day (EOD) dryness, corneal sensitivity and blink rate in soft contact lens (CL) wearers. Methods: Thirty-eight soft CL wearers (25 women and 13 men; mean age 27.1 ± 7.2 years) were enrolled. EOD dryness was assessed using a scale of 0–5 (0, none to 5, very intense). Mechanical and thermal (heat and cold) sensitivity were measured using a Belmonte’s gas esthesiometer. The blink rate was recorded using a video camera while subjects were wearing a hydrogel CL and watching a film for 90 min in a controlled environmental chamber. Results: A significant inverse correlation was found between EOD dryness and mechanical sensitivity (r: −0.39; p = 0.02); however, there were no significant correlations between EOD dryness and thermal sensitivity. A significant (r: 0.56; p < 0.001) correlation also was observed between EOD dryness and blink rate, but no correlations were found between blink rate and mechanical or thermal sensitivity. Conclusions: CL wearers with higher corneal sensitivity to mechanical stimulation reported more EOD dryness with habitual CL wear. Moreover, subjects reporting more EOD dryness had an increased blink rates during wear of a standard CL type. The increased blink rate could act to improve the ocular surface environment and relieve symptoms

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As increasingly more sophisticated materials and products are being developed and times-to-market need to be minimized, it is important to make available fast response characterization tools using small amounts of sample, capable of conveying data on the relationships between rheological response, process-induced material structure and product characteristics. For this purpose, a single / twin-screw mini-extrusion system of modular construction, with well-controlled outputs in the range 30-300 g/h, was coupled to a in- house developed rheo-optical slit die able to measure shear viscosity and normal-stress differences, as well as performing rheo-optical experiments, namely small angle light scattering (SALS) and polarized optical microscopy (POM). In addition, the mini-extruder is equipped with ports that allow sample collection, and the extrudate can be further processed into products to be tested later. Here, we present the concept and experimental set-up [1, 2]. As a typical application, we report on the characterization of the processing of a polymer blend and of the properties of extruded sheets. The morphological evolution of a PS/PMMA industrial blend along the extruder, the flow-induced structures developed and the corresponding rheological characteristics are presented, together with the mechanical and structural characteristics of produced sheets. The application of this experimental tool to other material systems will also be discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The MAP-i doctoral program of the Universities of Minho, Aveiro and Porto

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper presents three empirical studies designed to extend the test of the construct validity of the Satisfaction With Life Scale (SWLS) among Portuguese students. In the first study, the responses of 461 elementary and secondary education students were submitted to a principal component analysis. A solution of one single factor was chosen, accounting for 55.7 % of the total variance, with Cronbach alpha coefficient and inter-item correlation above .70 and .20, respectively. The second study used a sample of 317 undergraduate students and registered a similar factor solution for SWLS (/pq = 0.99), which accounted for 65.6 % of the total variance (Cronbach alpha .89 and inter-item correlation above .20). A test–retest analysis registered coefficients of .70 (T2) and .77 (T3) and no significant statistically differences between T2, T3 and T1. The third study used a sample of 107 foster care youths from elementary and secondary education. Confirmatory factor analysis results indicate adequate fit indexes for the one-factor solution (v2/df = 2.70, GFI = .96, CFI = .96), which showed convergent validity, reliability and homogeneity. In conclusion, there is psychometric evidence for the one-factor structure of the SWLS in Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We search for evidence of physics beyond the Standard Model in the production of final states with multiple high transverse momentum jets, using 20.3 fb−1 of proton-proton collision data recorded by the ATLAS detector at s√ = 8 TeV. No excess of events beyond Standard Model expectations is observed, and upper limits on the visible cross-section for non-Standard Model production of multi-jet final states are set. Using a wide variety of models for black hole and string ball production and decay, the limit on the cross-section times acceptance is as low as 0.16 fb at the 95% CL for a minimum scalar sum of jet transverse momentum in the event of about 4.3 TeV. Using models for black hole and string ball production and decay, exclusion contours are determined as a function of the production mass threshold and the gravity scale. These limits can be interpreted in terms of lower-mass limits on black hole and string ball production that range from 4.6 to 6.2 TeV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose – The purpose of this paper is to develop a subjective multidimensional measure of early career success during university-to-work transition. Design/methodology/approach – The construct of university-to-work success (UWS) was defined in terms of intrinsic and extrinsic career outcomes, and a three-stage study was conducted to create a new scale. Findings – A preliminary set of items was developed and tested by judges. Results showed the items had good content validity. Factor analyses indicated a four-factor structure and a second-order model with subscales to assess: career insertion and satisfaction, confidence in career future, income and financial independence, and adaptation to work. Third, the authors sought to confirm the hypothesized model examining the comparative fit of the scale and two alternative models. Results showed that fits for both the first- and second-order models were acceptable. Research limitations/implications – The proposed model has sound psychometric qualities, although the validated version of the scale was not able to incorporate all constructs envisaged by the initial theoretical model. Results indicated some direction for further refinement. Practical implications – The scale could be used as a tool for self-assessment or as an outcome measure to assess the efficacy of university-to-work programs in applied settings. Originality/value – This study provides a useful single measure to assess early career success during the university-to-work transition, and might facilitate testing of causal models which could help identify factors relevant for successful transition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches. Methods: Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-touch or three-pointtouch fitting approach. The lens’ back optic zone radius (BOZR) was 0.4 mm and 0.1 mm flatter than the first definite apical clearance lens, respectively. Differences between the baseline and post-CL wear for steepest, flattest and average corneal power (ACP) readings, central corneal astigmatism (CCA), maximum tangential curvature (KTag), anterior corneal surface asphericity, anterior corneal surface HOA and thinnest corneal thickness measured with Pentacam were compared. Results: A statistically significant flattening was found over time on the flattest and steepest simulated keratometry and ACP in apical-touch group (all p < 0.01). A statistically significant reduction in KTag was found in both groups after contact lens wear (all p < 0.05). Significant reduction was found over time in CCA (p = 0.001) and anterior corneal asphericity in both groups (p < 0.001). Thickness at the thinnest corneal point increased significantly after CL wear (p < 0.0001). Coma-like and total HOA root mean square (RMS) error were significantly reduced following CL wearing in both fitting approaches (all p < 0.05). Conclusion: Short-term rigid gas-permeable CL wear flattens the anterior cornea, increases the thinnest corneal thickness and reduces anterior surface HOA in keratoconus subjects. Apicaltouch was associated with greater corneal flattening in comparison to three-point-touch lens wear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To describe the stabilization of early adult-onset myopia in three university students after initiating orthokeratology treatment with corneal refractive therapy contact lenses. Methods: Three Caucasian early adult-onset progressing myopic subjects (1 male, 2 females) were fitted with corneal refractive therapy lenses to correct myopia between ?1.50 and ?2.50 D of sphere using Paragon CRT (Paragon Vision Sciences, Mesa, AZ)lenses for overnight orthokeratology. The pre-treatment refractive history from 2005 as well as refraction and axial length after treatment onset are reported over a period of 3 years between December 2009 and January 2013 with an additional year of follow-up after treatment discontinuation (January–December 2013). The peripheral refractive patterns and topographic changes are also reported individually. Results: Treatment was successful in all three subjects achieving uncorrected visual acuity of 20/20 or better monocularly. During a period of 3 years of follow-up the subjects did not experience progression in their refractive error, nor in their axial length (measured during the last 2 years of treatment and 1 year after discontinuation). Furthermore, the subjects recovered to their baseline refraction and did not progressed further over the following year after lens wear discontinuation. Conclusions: We cannot attribute a causative effect to the orthokeratology treatment alone as underlying mechanism for myopia stabilization in this 3 patients. However, the present report points to the possibility of stabilization of early adult-onset myopia progression in young adults using corneal refractive therapy treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this contribution, original limit analysis numerical results are presented dealing with some reinforced masonry arches tested at the University of Minho-UMinho, PT. Twelve in-scale circular masonry arches were considered, reinforced in various ways at the intrados or at the extrados. GFRP reinforcements were applied either on undamaged or on previously damaged elements, in order to assess the role of external reinforcements even in repairing interventions. The experimental results were critically discussed at the light of limit analysis predictions, based on a 3D FE heterogeneous upper bound approach. Satisfactory agreement was found between experimental evidences and the numerical results, in terms of failure mechanisms and peak load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado Integrado em Engenharia Civil

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of genome-scale metabolic models has been rapidly increasing in fields such as metabolic engineering. An important part of a metabolic model is the biomass equation since this reaction will ultimately determine the predictive capacity of the model in terms of essentiality and flux distributions. Thus, in order to obtain a reliable metabolic model the biomass precursors and their coefficients must be as precise as possible. Ideally, determination of the biomass composition would be performed experimentally, but when no experimental data are available this is established by approximation to closely related organisms. Computational methods however, can extract some information from the genome such as amino acid and nucleotide compositions. The main objectives of this study were to compare the biomass composition of several organisms and to evaluate how biomass precursor coefficients affected the predictability of several genome-scale metabolic models by comparing predictions with experimental data in literature. For that, the biomass macromolecular composition was experimentally determined and the amino acid composition was both experimentally and computationally estimated for several organisms. Sensitivity analysis studies were also performed with the Escherichia coli iAF1260 metabolic model concerning specific growth rates and flux distributions. The results obtained suggest that the macromolecular composition is conserved among related organisms. Contrasting, experimental data for amino acid composition seem to have no similarities for related organisms. It was also observed that the impact of macromolecular composition on specific growth rates and flux distributions is larger than the impact of amino acid composition, even when data from closely related organisms are used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Educação Especial (área de especialização em Dificuldades de Aprendizagem Específicas)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Optometria Avançada

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Article first published online: 13 NOV 2013