31 resultados para GAS SEPARATION EFFICIENCY

em Universidade do Minho


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rotary thermal diffusion column with the inner cylinder rotating and the outer cylinder static was used to separate n-heptane-benzene mixtures at different speeds of rotation. The results show that the column efficiency depends on the speed of rotation. For the optimum speed the increase in efficiency relative to the static column was of the order of 8%. The role of the geometric irregularities in the annulus width on performance of the rotary column is also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Buildings are responsible for more than 40% of the energy consumption and greenhouse gas emissions. Thus, increasing building energy efficiency is one the most cost-effective ways to reduce emissions. The use of thermal insulation materials could constitute the most effective way of reducing heat losses in buildings by minimising heat energy needs. These materials have a thermal conductivity factor, k (W/m.K) lower than 0.065 while other insulation materials such as aerated concrete can go up to 0.11. Current insulation materials are associated with negative impacts in terms of toxicity. Polystyrene, for example contains anti-oxidant additives and ignition retardants. In addition, its production involves the generation of benzene and chlorofluorocarbons. Polyurethane is obtained from isocyanates, which are widely known for their tragic association with the Bhopal disaster. Besides current insulation materials releases toxic fumes when subjected to fire. This paper presents experimental results on one-part geopolymers. It also includes global warming potential assessment and cost analysis. The results show that only the use of aluminium powder allows the production mixtures with a high compressive strength however its high cost means they are commercially useless when facing the competition of commercial cellular concrete. The results also show that one-part geopolymer mixtures based on 26%OPC +58.3%FA +8%CS +7.7%CH and 3.5% hydrogen peroxide constitute a promising cost efficient (67 euro/m3), thermal insulation solution for floor heating systems with low global warming potential of 443 KgCO2eq/m3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effectiveness of prefabricated hybrid composite plates (HCPs) as a seismic retrofitting solution for damaged interior RC beam-column joints is experimentally studied. HCP is composed of a thin plate made of strain hardening cementitious composite (SHCC) reinforced with CFRP sheets/laminates. Two full-scale severely damaged interior beam-column joints are retrofitted using two different configurations of HCPs. The effectiveness of these retrofitting solutions mainly in terms of hysteretic response, dissipated energy, degradation of secant stiffness, displacement ductility and failure modes are compared to their virgin states. According to these criteria, both solutions resulted in superior responses regarding the ones registered in their virgin states.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recycling of pavements is nowadays a very important question to the road paving industry. With the objective of incorporating higher percentages of reclaimed asphalt (RA) materials in recycled asphalt mixtures, new techniques have been developed in the last years. The use of foamed bitumen is normally associated with the production of cold asphalt mixtures, which usually show lower quality standards. However, the objective of the work presented in this paper is to assess the use of foamed bitumen as the binder of warm asphalt mixtures incorporating 30% RA, which have quality standards similar to those of conventional mixtures. Thus, five mixtures have been produced with 30% RA, one of them with a conventional bitumen (control mix) and the others with foamed bitumen at different production temperatures. The mixtures were tested for compactability and water sensitivity and the results show a possible reduction of 25 ºC in the production temperatures, while the water sensitivity test results were kept close to 90 %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly(vinylidene fluoride-co-chlorotrifluoroethylene) – P(VDF-CTFE) membranes are increasingly interesting for a wide range of applications, including battery separators, filtration membranes and biomedical applications. This work reports on the morphology, hydrophobicity, thermal and mechanical properties variation of P(VDF-CTFE) membranes processed by nonsolvent induced phase separation technique (NIPS) as a function of the main processing parameters. All membranes show a porous structure composed of large spherulites, (interconnected) micropores and/or microvoids depending on the processing conditions used that in turn affect their hydrophobicity and mechanical properties. The degree of crystallinity of the membranes remains approximately constant with a value of about 15 %, except for the membranes immediately immersed in ethanol, which is of about 23 %. In turn, the crystalline phases present in the copolymer is mainly affected by the temperature and nonsolvent characteristics of the coagulation bath, the β-phase content ranging from 33 to 100 %, depending on those processing parameters. It was show that the temperature of water-based coagulation bath plays an important role in order to produce structurally uniform and homogeneous porous membranes, which is particularly important from the point of view of technological applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This document reports the importance of the category of consciousness and education for sustainability in the school environment. Education in school has a potential to make the benefits of the building construction visible for society and media, showing to the students, parents and communities how sustainability in built environment could improve the people life in economic, social and environment aspects. Thus, this paper addresses the main events related to sustainability, such as the Stockholm Conference, the Brundtland report, United Nations Conference on Environment and Development (UNCED) and Agenda 21, until reaching the necessity of the elaboration of Methodologies for environmental assessment of building, and later, the development of the specific methodologies according to the buildings. It is also described some examples of sustainability in schools in Germany, Finland and Italy and what kind of sustainable systems those countries are currently using.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The huge efforts for the achievement of highly purified biomolecules are growing every day. A great number of efficient techniques, such as chromatography, are already available in laboratory for separation processes. However, membrane-based technologies are the best match to assure simplicity, efficiency and easy scale-up procedures. Herein we report the modification of a commercial microfiltration membrane for plasmid DNA purification by agarose gel impregnation. The membrane was characterized by SEM, ATR-FTIR, EDS, contact angle, and porosity measurements. Additionally, the membrane pore radius was estimated from observed rejections of different proteins and with that information the rejection of a 6050 bp plasmid DNA (pDNA) molecule was estimated for different values of flux using a theoretical model of large flexible molecules in membranes with parallel cylindrical pores, which is applicable to pDNA ultrafiltration in conventional membranes, as recently shown in the literature. The experimental results show that the modified membrane has higher pDNA rejections than the predicted by the model, suggesting that the different type of porous structure that a hydrogel has, may have a positive effect on pDNA rejections as compared to other biomolecules with more rigid structures, making this type of modified membranes potential better candidates to be used for the selective recovery of pDNA in this type of bioprocesses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches. Methods: Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-touch or three-pointtouch fitting approach. The lens’ back optic zone radius (BOZR) was 0.4 mm and 0.1 mm flatter than the first definite apical clearance lens, respectively. Differences between the baseline and post-CL wear for steepest, flattest and average corneal power (ACP) readings, central corneal astigmatism (CCA), maximum tangential curvature (KTag), anterior corneal surface asphericity, anterior corneal surface HOA and thinnest corneal thickness measured with Pentacam were compared. Results: A statistically significant flattening was found over time on the flattest and steepest simulated keratometry and ACP in apical-touch group (all p < 0.01). A statistically significant reduction in KTag was found in both groups after contact lens wear (all p < 0.05). Significant reduction was found over time in CCA (p = 0.001) and anterior corneal asphericity in both groups (p < 0.001). Thickness at the thinnest corneal point increased significantly after CL wear (p < 0.0001). Coma-like and total HOA root mean square (RMS) error were significantly reduced following CL wearing in both fitting approaches (all p < 0.05). Conclusion: Short-term rigid gas-permeable CL wear flattens the anterior cornea, increases the thinnest corneal thickness and reduces anterior surface HOA in keratoconus subjects. Apicaltouch was associated with greater corneal flattening in comparison to three-point-touch lens wear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. The purpose of this work was to evaluate the potential of a novel custom-designed rigid gas permeable (RGP) contact lens to modify the relative peripheral refractive error in a sample of myopic patients. Methods. Fifty-two right eyes of 52 myopic patients (mean [TSD] age, 21 [T2] years) with spherical refractive errors ranging from j0.75 to j8.00 diopters (D) and refractive astigmatism of 1.00 D or less were fitted with a novel experimental RGP (ExpRGP) lens designed to create myopic defocus in the peripheral retina. A standard RGP (StdRGP) lens was used as a control in the same eye. The relative peripheral refractive error was measured without the lens and with each of two lenses (StdRGP and ExpRGP) using an open-field autorefractometer from 30 degrees nasal to 30 degrees temporal, in 5-degree steps. The effectiveness of the lens design was evaluated as the amount of relative peripheral refractive error difference induced by the ExpRGP compared with no lens and with StdRGP conditions at 30 degrees in the nasal and temporal (averaged) peripheral visual fields. Results. Experimental RGP lens induced a significant change in relative peripheral refractive error compared with the nolens condition (baseline), beyond the 10 degrees of eccentricity to the nasal and temporal side of the visual field (p G 0.05). The maximum effect was achieved at 30 degrees. Wearing the ExpRGP lens, 60% of the eyes had peripheral myopia exceeding j1.00 D, whereas none of the eyes presented with this feature at baseline. There was no significant correlation (r = 0.04; p = 0.756) between the degree of myopia induced at 30 degrees of eccentricity of the visual field with the ExpRGP lens and the baseline refractive error. Conclusions. Custom-designed RGP contact lenses can generate a significant degree of relative peripheral myopia in myopic patients regardless of their baselin spherical equivalent refractive error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate neophyte contact lens wearers’ fitting to rigid gas permeable (RGP) contact lenses in terms of wearing time, tear volume, stability, corneal staining, and subjective ratings, over a 1-month period of time. Methods: Twenty-two young healthy subjects were enrolled for wearing RGP on a daily wear basis. The participants included in this study never wore contact lenses and showed a value under 10 in McMonnies Questionnaire. Contact Lens Dry Eye Questionnaire, Visual Analog Scales, Schirmer test, tear film break-up time (BUT), and corneal staining grading were performed. Follow-up visits were scheduled at 1, 7, 15, and 28 days. Results: Six subjects dropped out due to discomfort from the study before 1 month (27% of discontinuation rate). Successful RGP wearers (16 participants) achieved high levels of subjective vision and reported comfort scores of approximately 9 of 10 between 10 and 15 days. They reported wearing their lenses for an average of 10.1262.43 hr after 1 month of wear. Conversely, unsuccessful wearers discontinued wearing the lenses after the first 10 to 15 days, showing comfort scores and wearing time significantly lower compared with the first day of wear. Schirmer test showed a signifi- cant increase at 10 days (P,0.001), and the BUT trends decreased after the first week of wear in unsuccessful group. Conclusions: Symptomatology related with dryness and discomfort, detected during the first 10 days of the adaptation, may help the clinician to predict those participants who will potentially fail to adapt to RGP lens wear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article focuses on the personal experiences of Portuguese women regarding separation and divorce. The sample included 96 women, with at least 1 child, who responded to an inventory that addressed conflict, dysfunctional conjugality, emotional experiences, social support, and adaptation to divorce. Higher levels of conflict and marital dysfunction in litigious divorces were found, as well as more conflict when different lawyers were employed. Those women who were satisfied with alimony and visiting rights reported less conflict, fewer negative emotional experiences, and greater social support. Level of education and duration of separation influenced women’s perceptions. Implications for intervention are addressed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article revisits Michel Chevalier’s work and discussions of tariffs. Chevalier shifted from Saint-Simonism to economic liberalism during his life in the 19th century. His influence was soon perceived in the political world and economic debates, mainly because of his discussion of tariffs as instruments of efficient transport policies. This work discusses Chevalier’s thoughts on tariffs by revisiting his masterpiece, Le Cours d’Économie Politique. Data Envelopment Analysis (DEA) was conducted to test Chevalier’s hypothesis on the inefficiency of French tariffs. This work showed that Chevalier’s claims on French tariffs are not validated by DEA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We provide a comparative analysis of how short-run variations in carbon and energy prices relate to each other in the emerging greenhouse gas market in California (Western Climate Initiative [WCI], and the European Union Emission Trading Scheme [EU ETS]). We characterize the relationship between carbon, gas, coal, electricity and gasoline prices and an indicator for economic activity, and present a first analysis of carbon prices in the WCI. We also provide a comparative analysis of the structures of the two markets. We estimate a vector autoregressive model and the impulse--response functions. Our main findings show a positive impact from a carbon shock toward electricity, in both markets, but larger in the WCI electricity price, indicating more efficiency. We propose that the widening of carbon market sectors, namely fuels transport and electricity imports, may contribute to this result. To conclude, the research shows significant and coherent relations between variables in WCI, which demonstrate some degree of success for a first year in operation. Reversely, the EU ETS should complete its intended market reform, to allow for more impact of the carbon price. Finally, in both markets, there is no evidence of carbon pricing depleting economic activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The barrier effect and the performance of an organic–inorganic hybrid (OIH) sol–gel coating are highlydependent on the coating deposition method as well as processing conditions. In this work, studies onthe influence of experimental parameters using the dip coating method were performed. Factors suchas residence time (Rt), a curing step between each dip step and the number of layers of sol–gel OIHfilms deposited on HDGS to prevent corrosion in highly alkaline environments were studied. These OIHcoatings were obtained using a functionalized siloxane, 3-isociantepropyltriethoxysilane that reactedwith a diamino-functionalized oligopolymer (Jeffamine®D-230). The barrier efficiency of OIH coatings insimulated concrete pore solutions (SCPS) was assessed in the first moments of contact, by electrochemicalimpedance spectroscopy and potentiodynamic methods. The durability and stability of the OIH coatings inSCPS was monitored during eight days by macrocell current density. The morphological characterizationof the surface was performed by scanning electronic microscopy before and after exposure to SCPS.Glow discharge optical emission spectroscopy was used to obtain quantitative composition profiles toinvestigate the thickness of the OIH coatings as a function of the number of layers deposited and theinfluence of the Rt in the coating thickness.