9 resultados para Cornea, corneal transplant, keratoplasty, limbal transplant
em Universidade do Minho
Resumo:
PTX3-based genetic testing for risk of aspergillosis after lung transplant
Resumo:
Purpose: To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches. Methods: Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-touch or three-pointtouch fitting approach. The lens’ back optic zone radius (BOZR) was 0.4 mm and 0.1 mm flatter than the first definite apical clearance lens, respectively. Differences between the baseline and post-CL wear for steepest, flattest and average corneal power (ACP) readings, central corneal astigmatism (CCA), maximum tangential curvature (KTag), anterior corneal surface asphericity, anterior corneal surface HOA and thinnest corneal thickness measured with Pentacam were compared. Results: A statistically significant flattening was found over time on the flattest and steepest simulated keratometry and ACP in apical-touch group (all p < 0.01). A statistically significant reduction in KTag was found in both groups after contact lens wear (all p < 0.05). Significant reduction was found over time in CCA (p = 0.001) and anterior corneal asphericity in both groups (p < 0.001). Thickness at the thinnest corneal point increased significantly after CL wear (p < 0.0001). Coma-like and total HOA root mean square (RMS) error were significantly reduced following CL wearing in both fitting approaches (all p < 0.05). Conclusion: Short-term rigid gas-permeable CL wear flattens the anterior cornea, increases the thinnest corneal thickness and reduces anterior surface HOA in keratoconus subjects. Apicaltouch was associated with greater corneal flattening in comparison to three-point-touch lens wear.
Resumo:
Purpose: To determine the relationship of goblet cell density (GCD) with tear function and ocular surface physiology. Methods: This was a cross-sectional study conducted in 35 asymptomatic subjects with mean age 23.8±3.6 years. Tear film assessment, conjunctiva and cornea examination were done in each subject. Conjunctival impression cytology was performed by applying Nitrocellulose Millipore MFTM-Membrane filter over the superior bulbar conjunctiva. The filter paper was than fixed with 96% ethanol and stained with Periodic Acid Schiff, Hematoxylin and Eosin. GCD was determined by optical microscopy. Relation between GCD and Schirmer score, tear break-up time (TBUT), bulbar redness, limbal redness and corneal staining was determined. Results: The mean GCD was 151±122 cells/mm2. GCD was found higher in eyes with higher Schirmer score but it was not significant (p = 0.75). There was a significant relationship ofGCDwith TBUT (p = 0.042). GCD was not correlated with bulbar redness (p = 0.126), and limbal redness (p = 0.054) as well as corneal staining (p = 0.079). No relationship of GCD with age and gender of the subjects (p > 0.05) was observed. Conclusion: GCD was found correlated with TBUT but no significant correlation was found with the aqueous portion of the tear, limbal as well as bulbar redness and corneal staining.
Resumo:
Dissertação de mestrado em Optometria Avançada
Resumo:
The thymus is the central organ responsible for the generation of T lymphocytes (1). Various diseases cause the thymus to produce in- sufficient T cells, which can lead to immune-suppression (2). Since T cells are essential for the protection against pathogens, it is crucial to promote de novo differentiation of T cells on diseased individuals. The available clinical solutions are: 1) one protocol involving the transplant of thymic stroma from unrelated children only applicable for athymic children (3); 2) for patients with severe peripheral T cell depletion and reduced thymic activity, the administration of stimu- lating molecules stimulating the activity of the endogenous thymus (4). A scaffold (CellFoam) was suggested to support thymus regen- eration in vivo (5), although this research was discontinued. Herein, we propose an innovative strategy to generate a bioartificial thymus. We use a polycaprolactone nanofiber mesh (PCL-NFM) seeded and cultured with human thymic epithelial cells (hTECs). The cells were obtained from infant thymus collected during pediatric cardio-tho- racic surgeries. We report new data on the isolation and characterization of those cells and their interaction with PCL-NFM, by expanding hTECs into relevant numbers and by optimizing cell seeding methods.
Resumo:
Purpose: To evaluate how soft lens power affects rigid gas-permeable (RGP) lens power and visual acuity (VA) in piggyback fittings for keratoconus. Methods: Sixteen keratoconus subjects (30 eyes) were included in the study. Piggyback contact lens fittings combining Senofilcon-A soft lenses of −6.00, −3.00, +3.00 and +6.00 D with Rose K2 RGP contact lenses were performed. Corneal topography was taken on the naked eye and over each soft contact lens before fitting RGP lenses. Mean central keratometry, over-refraction, RGP back optic zone radius (BOZR) and estimated final power as well as VA were recorded and analyzed. Results: In comparison to the naked eye, the mean central keratometry flattened with both negative lens powers (p < 0.05 in all cases), did not change with the +3.00 soft lens power (p = 1.0); and steepened with the +6.00 soft lens power (p = 0.02). Rigid gas-permeable over-refraction did not change significantly between different soft lens powers (all p > 0.05). RGP’s BOZR decreased significantly with both positive in comparison with both negative soft lens powers (all p < 0.001), but no significant differences were found among negative- or positive-powers separately (both p > 0.05). Estimated RGP’s final power increased significantly with positive in comparison with negative lens powers (all p < 0.001), but no significant differences were found among negative or positive lens powers separately (both p > 0.05). Visual acuity did not change significantly between the different soft lens powers assessed (all p > 0.05). Conclusion: The use of negative-powered soft lenses in piggyback fitting reduces RGP lens power without impacting VA in keratoconus subjects.
Resumo:
Purpose: To study the relationship among the variables intensity ofthe end-of-day (EOD) dryness, corneal sensitivity and blink rate in soft contact lens (CL) wearers. Methods: Thirty-eight soft CL wearers (25 women and 13 men; mean age 27.1 ± 7.2 years) were enrolled. EOD dryness was assessed using a scale of 0–5 (0, none to 5, very intense). Mechanical and thermal (heat and cold) sensitivity were measured using a Belmonte’s gas esthesiometer. The blink rate was recorded using a video camera while subjects were wearing a hydrogel CL and watching a film for 90 min in a controlled environmental chamber. Results: A significant inverse correlation was found between EOD dryness and mechanical sensitivity (r: −0.39; p = 0.02); however, there were no significant correlations between EOD dryness and thermal sensitivity. A significant (r: 0.56; p < 0.001) correlation also was observed between EOD dryness and blink rate, but no correlations were found between blink rate and mechanical or thermal sensitivity. Conclusions: CL wearers with higher corneal sensitivity to mechanical stimulation reported more EOD dryness with habitual CL wear. Moreover, subjects reporting more EOD dryness had an increased blink rates during wear of a standard CL type. The increased blink rate could act to improve the ocular surface environment and relieve symptoms
Resumo:
Purpose: To describe the stabilization of early adult-onset myopia in three university students after initiating orthokeratology treatment with corneal refractive therapy contact lenses. Methods: Three Caucasian early adult-onset progressing myopic subjects (1 male, 2 females) were fitted with corneal refractive therapy lenses to correct myopia between ?1.50 and ?2.50 D of sphere using Paragon CRT (Paragon Vision Sciences, Mesa, AZ)lenses for overnight orthokeratology. The pre-treatment refractive history from 2005 as well as refraction and axial length after treatment onset are reported over a period of 3 years between December 2009 and January 2013 with an additional year of follow-up after treatment discontinuation (January–December 2013). The peripheral refractive patterns and topographic changes are also reported individually. Results: Treatment was successful in all three subjects achieving uncorrected visual acuity of 20/20 or better monocularly. During a period of 3 years of follow-up the subjects did not experience progression in their refractive error, nor in their axial length (measured during the last 2 years of treatment and 1 year after discontinuation). Furthermore, the subjects recovered to their baseline refraction and did not progressed further over the following year after lens wear discontinuation. Conclusions: We cannot attribute a causative effect to the orthokeratology treatment alone as underlying mechanism for myopia stabilization in this 3 patients. However, the present report points to the possibility of stabilization of early adult-onset myopia progression in young adults using corneal refractive therapy treatment.
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Informática Médica)