2 resultados para 13 kvinnoperspektiv på rätten

em Universidade do Minho


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and aims: Small bowel capsule endoscopy (SBCE) allows mapping of small bowel inflammation in Crohn’s disease (CD). We aimed to assess the prognostic value of the severity of inflammatory lesions, quantified by the Lewis score (LS), in patients with isolated small bowel CD. Methods: A retrospective study was performed in which 53 patients with isolated small bowel CD were submitted to SBCE at the time of diagnosis. The Lewis score was calculated and patients had at least 12 months of follow-up after diagnosis. As adverse events we defined disease flare requiring systemic corticosteroid therapy, hospitalization and/or surgery during follow-up. We compared the incidence of adverse events in 2 patient subgroups, i.e. those with moderate or severe inflammatory activity (LS =790) and those with mild inflammatory activity (135 = LS < 790). Results: The LS was =790 in 22 patients (41.5%), while 58.5% presented with LS between 135 and 790. Patients with a higher LS were more frequently smokers (p = 0.01), males (p = 0017) and under immunosuppressive therapy (p = 0.004). In multivariate analysis, moderate to severe disease at SBCE was independently associated with corticosteroid therapy during follow-up, with a relative risk (RR) of 5 (p = 0.011; 95% confidence interval [CI] 1.5–17.8), and for hospitalization, with an RR of 13.7 (p = 0 .028; 95% CI 1.3–141.9). Conclusion: In patients with moderate to severe inflammatory activity there were higher prevalences of corticosteroid therapy demand and hospitalization during follow-up. Thus, stratifying the degree of small bowel inflammatory activity with SBCE and LS calculation at the time of diagnosis provided relevant prognostic value in patients with isolated small bowel CD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Films of BaFe12O19/P(VDF-TrFE) composites with 5, 10 and 20 %wt Barium ferrite content have been fabricated. BaFe12O19 microparticles have the shape of thin hexagonal platelets, the easy direction of magnetization remaining along the c axis, which is perpendicular to the plates. This fact allows for ferrite particles orientation in-plane and out-of-plane within the composite films, as confirmed by measured hysteresis loops. While the in-plane induced magnetoelectric effect (ME) is practically zero, these composite films show a good out-of-plane magnetoelectric effect. with maximum ME coupling coefficient changes of 3, 17 and 2 mV/cm.Oe for the 5, 10 and 20%wt Barium ferrite content films, respectively. We infer that this ME behavior appears as driven by the magnetization process arising when we applied the external magnetic field. We have also measured linear and reversible magnetoelectric effect for low applied bias field, when magnetization process is still reversible.