140 resultados para López Jordán, Ricardo, 1822-1889.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is an increasing interest in thin and flexible energy storage devices to meet modern society needs for applications such as, radio frequency sensing, interactive packaging and other consumer products. Printed batteries comply these requirements and are an excellent alternative to conventional batteries for many applications. Flexible and micro-batteries are also included in the area of printed batteries whenever fabricated by printing technologies. The main characteristics, advantages, disadvantages, developments, and printing techniques of printed batteries are presented and discussed in this review. The state-of-art takes into account both the research and industrial levels. In the academic one, the research progress of printed batteries is summarized divided in lithium-ion battery (Li-ion), zinc-manganese dioxide (Zn-MnO2), and other battery types with emphasis on the different materials for anode, cathode and separator as well as in the battery design. With respect to the industrial state-of-art, materials, device formulations and manufacturing techniques are presented. Finally, the prospects and challenges of printed batteries are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Separator membranes based on poly(vinylidene fluoride-co-chlorotrifluoroethylene) (PVDF-CTFE) were prepared by solvent casting technique based on its phase diagram in N,Ndimethylformamide (DMF) solvent. The microstructure of the PVDF-CTFE separator membranes depends on the initial position (temperature and concentration) of the solution in the phase diagram of the PVDF-CTFE/DMF system. A porous microstructure is achieved for PVDF-CTFE membranes with solvent evaporation temperature up to 50 ºC for a polymer/solvent relative concentration of 20 wt%. The ionic conductivity of the separator depends on the degree of porosity and electrolyte uptake, the highest room temperature value being 1.5 mS.cm-1 for the sample with 20 wt% of polymer concentration and solvent evaporation temperature at 25 ºC saturated with 1 mol L-1 lithium bis (trifluoromethanesulfonyl) imide (LiTFSI) in propylene carbonate (PC). This PVDF-CTFE separator membrane in Li/C-LiFePO4 half-cell shows good cyclability and rate capability, showing a discharge value after 50 cycles of 92 mAh.g-1 at 2 C, which is still 55% of the theoretical value. PVDF-CTFE separators are thus excellent candidates for high-power and safety lithium-ion batteries applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[Excerpt] Bone tissue engineering is a very challenging and promising field, which handles with the limitations of bone regenerative capacity and the failure of current orthopedic implants [1]. This work describes the preparation and characterization of an injectable dextrin-based hydrogel (oDex) able to incorporate nanoparticles, cells, biomolecules or Bonelike~ granules [2]. (...)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Portuguese housing sector experienced a significant growth throughout the 20th century, particularly in the last quarter, after the democratic revolution in 1974. In fact, the number of buildings built between 1970 and 1990 is more than one third of the buildings actually existing in Portugal. Therefore most of them were built before the publication of the first regulation concerning the energy efficiency in buildings. Regarding this scenario, it would be expected that rehabilitation activities would represent most of the current construction activities. However, given some remaining barriers from old social policies, this situation is not observed; actually building retrofitting is the least significant sector, accentuating the degradation level of major part of the Portuguese housing stock. Several studies show that the main problems are found in the buildings envelope elements, such as roofs and façades. Based on this context, the aim of this paper is to introduce some examples of building retrofitting systems that, adapted to the Portuguese main needs and requirements may represent sustainable solutions to overcome the identified needs of Portuguese buildings' envelope.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento em Ciências da Literatura (área de especialização em Literatura Portuguesa).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pedido de patente provisório nº 20151000053763, data de pedido 18 março 2015, em parceria com a Empresa Barcelcom, S. A..

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wireless body sensor networks (WBSNs) constitute a key technology for closing the loop between patients and healthcare providers, as WBSNs provide sensing ability, as well as mobility and portability, essential characteristics for wide acceptance of wireless healthcare technology. However, one important and difficult aspect of WBSNs is to provide data transmissions with quality of service, among other factors due to the antennas being small size and placed close to the body. Such transmissions cannot be fully provided without the assumption of a MAC protocol that solves the problems of the medium sharing. A vast number of MAC protocols conceived for wireless networks are based on random or scheduled schemes. This paper studies firstly the suitability of two MAC protocols, one using CSMA and the other TDMA, to transmit directly to the base station the signals collected continuously from multiple sensor nodes placed on the human body. Tests in a real scenario show that the beaconed TDMA MAC protocol presents an average packet loss ratio lower than CSMA. However, the average packet loss ratio is above 1.0 %. To improve this performance, which is of vital importance in areas such as e-health and ambient assisted living, a hybrid TDMA/CSMA scheme is proposed and tested in a real scenario with two WBSNs and four sensor nodes per WBSN. An average packet loss ratio lower than 0.2 % was obtained with the hybrid scheme. To achieve this significant improvement, the hybrid scheme uses a lightweight algorithm to control dynamically the start of the superframes. Scalability and traffic rate variation tests show that this strategy allows approximately ten WBSNs operating simultaneously without significant performance degradation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When representing the requirements for an intended software solution during the development process, a logical architecture is a model that provides an organized vision of how functionalities behave regardless of the technologies to be implemented. If the logical architecture represents an ambient assisted living (AAL) ecosystem, such representation is a complex task due to the existence of interrelated multidomains, which, most of the time, results in incomplete and incoherent user requirements. In this chap- ter, we present the results obtained when applying process-level modeling techniques to the derivation of the logical architecture for a real industrial AAL project. We adopt a V-Model–based approach that expresses the AAL requirements in a process-level perspec- tive, instead of the traditional product-level view. Additionally, we ensure compliance of the derived logical architecture with the National Institute of Standards and Technology (NIST) reference architecture as nonfunctional requirements to support the implementa- tion of the AAL architecture in cloud contexts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increase in life expectancy with a decrease in birth rates is contributing to the ageing of the European population. This phenomenon, coupled with greater awareness of the quality of life, the need to have cost-efficient assistive care, the intention of people to live independently in their homes, and the technological developments in recent decades, have contributed to the emergence of the concept of ambient assisted living (AAL). AAL solutions aim to provide healthy and safe ageing to users through promoting independence in performing daily activities and interacting with technology, taking into consideration the deterioration of the users’ capabilities and the reduced costs of the solutions. In this chapter, AAL developments of monitoring activities of daily living (ADLs) and participation in a virtual community with the selected stakeholders are introduced, their roadmap with the expected technological developments are described, and the expected impact of these solutions on the end users of the developed solutions are discussed. This enables a real user guidance structure that represents the different needs and limitations of each user, presenting a highly structured project based on personas and possible solutions for them. The AAL4ALL Ambient Assisted Living for All (ALL4ALL) project is considered here as a case study to analyze and illustrate the ALL concepts discussed in this chapter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este relatório segue a metodologia utilizada no estudo da produção científica da Universidade do Minho do quinquénio 2008-2012. No estudo da produção de 2009-2013, para além da análise dos dados indexados na Web of Science, optou-se por acrescentar a análise dos dados indexados na Scopus, procedendo-se à comparação dos resultados entre ambas as bases de dados sempre que adequado e possível.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To analyze dry eye disease (DED) tests and their consistency in similar nonsymptomatic population samples living in two geographic locations with different climates (Continental vs. Atlantic). Methods. This is a pilot study including 14 nonsymptomatic residents from Valladolid (Continental climate, Spain) and 14 sex-matched and similarly aged residents from Braga (Atlantic climate, Portugal); they were assessed during the same season (spring) of two consecutive years. Phenol red thread test, conjunctival hyperemia, fluorescein tear breakup time, corneal and conjunctival staining, and Schirmer test were evaluated on three different consecutive visits. Reliability was assessed using the intraclass correlation coefficient and weighted kappa (J) coefficient for quantitative and ordinal variables, respectively. Results. Fourteen subjects were recruited in each city with a mean (TSD) age of 63.0 (T1.7) and 59.1 (T0.9) years (p = 0.08) in Valladolid and Braga, respectively. Intraclass correlation coefficient and J values of the tests performed were below 0.69 and 0.61, respectively, for both samples, thus showing moderate to poor reliability. Subsequently, comparisons were made between the results corresponding to the middle and higher outdoor relative humidity (RH) visit in each location as there were no differences in mean temperature (p Q 0.75) despite RH values significantly differing (p e 0.005). Significant (p e 0.05) differences were observed between Valladolid and Braga samples on tear breakup time (middle RH visit, 2.76 T 0.60 vs. 5.26 T 0.64 seconds; higher RH visit, 2.61 T 0.32 vs. 5.78 T 0.88 seconds) and corneal (middle RH, 0.64 T 0.17 vs. 0.14 T 0.10; higher RH, 0.60 T 0.22 vs. 0.0 T 0.0) and conjunctival staining (middle RH, 0.61 T 0.17 vs. 0.14 T 0.08; higher RH, 0.57 T 0.15 vs. 0.18 T 0.09). Conclusions. This pilot study provides initial evidence to support that DED test outcomes assessing the ocular surface integrity and tear stability are climate dependent. Future large-sample studies should support these outcomes also in DED patients. This knowledge is fundamental for multicenter clinical trials. Lack of consistency in diagnostic clinical tests for DED was also corroborated. (Optom Vis Sci 2015;92:e284Ye289)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To study the relationship among the variables intensity ofthe end-of-day (EOD) dryness, corneal sensitivity and blink rate in soft contact lens (CL) wearers. Methods: Thirty-eight soft CL wearers (25 women and 13 men; mean age 27.1 ± 7.2 years) were enrolled. EOD dryness was assessed using a scale of 0–5 (0, none to 5, very intense). Mechanical and thermal (heat and cold) sensitivity were measured using a Belmonte’s gas esthesiometer. The blink rate was recorded using a video camera while subjects were wearing a hydrogel CL and watching a film for 90 min in a controlled environmental chamber. Results: A significant inverse correlation was found between EOD dryness and mechanical sensitivity (r: −0.39; p = 0.02); however, there were no significant correlations between EOD dryness and thermal sensitivity. A significant (r: 0.56; p < 0.001) correlation also was observed between EOD dryness and blink rate, but no correlations were found between blink rate and mechanical or thermal sensitivity. Conclusions: CL wearers with higher corneal sensitivity to mechanical stimulation reported more EOD dryness with habitual CL wear. Moreover, subjects reporting more EOD dryness had an increased blink rates during wear of a standard CL type. The increased blink rate could act to improve the ocular surface environment and relieve symptoms

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Published online first in 10 July 2013