32 resultados para rotation invariant
Resumo:
Dissertação de mestrado em Engenharia Humana
Resumo:
The normalized differential cross section for top-quark pair production in association with at least one jet is studied as a function of the inverse of the invariant mass of the tt¯+1-jet system. This distribution can be used for a precise determination of the top-quark mass since gluon radiation depends on the mass of the quarks. The experimental analysis is based on proton--proton collision data collected by the ATLAS detector at the LHC with a centre-of-mass energy of 7 TeV corresponding to an integrated luminosity of 4.6 fb−1. The selected events were identified using the lepton+jets top-quark-pair decay channel, where lepton refers to either an electron or a muon. The observed distribution is compared to a theoretical prediction at next-to-leading-order accuracy in quantum chromodynamics using the pole-mass scheme. With this method, the measured value of the top-quark pole mass, mpolet, is: mpolet =173.7 ± 1.5 (stat.) ± 1.4 (syst.) +1.0−0.5 (theory) GeV. This result represents the most precise measurement of the top-quark pole mass to date.
Resumo:
Dissertação de mestrado em Engenharia de Sistemas
Resumo:
Dissertação de mestrado em Engenharia Humana
Resumo:
We summarise recent results about the evolution of linear density perturbations in scalar field cosmologies with an exponential potential. We use covariant and gauge invariant perturbation variables and a dynamical systems' approach. We establish under what conditions do the perturbations decay to the future in agreement with the cosmic no-hair conjecture.
Resumo:
Dissertação de mestrado integrado em Biomedical Engineering Biomaterials, Biomechanics and Rehabilitation
Resumo:
Three PEGylated derivatives of 1,4,7,10-tetraazacyclododecane-1-((6-amino)hexanoic)-4,7,10-triacetic acid) (DOTA-AHA) with different molecular weights were prepared and characterized. Their Gd(III) chelates were studied in aqueous solution using variable-temperature 1H nuclear magnetic relaxation dispersion (NMRD) and 17ONMR spectroscopy in view of the determination of their relaxivity and the parameters that govern it. The relaxivity varied from 5.1 to 6.5 mM-1.s-1 (37 ºC and 60 MHz) with the increasing molecular weight of the PEG chain, being slightly higher than that of the parent chelate Gd(DOTA-AHA), due to a small contribution of a slow global rotation of the complexes. A variable temperature 1H NMR study of several Ln(III) chelates of DOTA-A(PEG750)HA allowed the determination of the isomeric M/m ratio (M = square antiprismatic isomer and m = twisted square antiprismatic isomer, the latter presenting a much faster water exchange) which for the Gd(III) chelate was estimated in circa 1:0.2, very close to that of [Gd(DOTA)]-. This explains why the PEGylated Gd(III) chelate has a water rate exchange similar to that of [Gd(DOTA)]-. The predominance of the M isomer is a consequence of the bulky PEG moiety which does not favor the stabilization of the m isomer in sterically crowded systems at the substituent site, contrary to what happens with less packed asymmetrical DOTA-type chelates with substitution in one of the four acetate C(α) atoms.
Resumo:
Observers can adjust the spectrum of illumination on paintings for optimal viewing experience. But can they adjust the colors of paintings for the best visual impression? In an experiment carried out on a calibrated color moni- tor images of four abstract paintings obtained from hyperspectral data were shown to observers that were unfamiliar with the paintings. The color volume of the images could be manipulated by rotating the volume around the axis through the average (a*, b*) point for each painting in CIELAB color space. The task of the observers was to adjust the angle of rotation to produce the best subjective impression from the paintings. It was found that the distribution of angles selected for data pooled across paintings and observers could be de- scribed by a Gaussian function centered at 10o, i.e. very close to the original colors of the paintings. This result suggest that painters are able to predict well what compositions of colors observers prefer.
Resumo:
For a given self-map f of M, a closed smooth connected and simply-connected manifold of dimension m ≥ 4, we provide an algorithm for estimating the values of the topological invariant Dm r [f], which equals the minimal number of r-periodic points in the smooth homotopy class of f. Our results are based on the combinatorial scheme for computing Dm r [f] introduced by G. Graff and J. Jezierski [J. Fixed Point Theory Appl. 13 (2013), 63–84]. An open-source implementation of the algorithm programmed in C++ is publicly available at http://www.pawelpilarczyk.com/combtop/.
Resumo:
A search is performed for narrow resonances decaying into WW, WZ, or ZZ boson pairs using 20.3 fb−1 of proton--proton collision data at a centre-of-mass energy of s√ = 8 TeV recorded with the ATLAS detector at the Large Hadron Collider. Diboson resonances with masses in the range from 1.3 to 3.0 TeV are sought after using the invariant mass distribution of dijets where both jets are tagged as a boson jet, compatible with a highly boosted W or Z boson decaying to quarks, using jet mass and substructure properties. The largest deviation from a smoothly falling background in the observed dijet invariant mass distribution occurs around 2 TeV in the WZ channel, with a global significance of 2.5 standard deviations. Exclusion limits at the 95% confidence level are set on the production cross section times branching ratio for the WZ final state of a new heavy gauge boson, W′, and for the WW and ZZ final states of Kaluza--Klein excitations of the graviton in a bulk Randall--Sundrum model, as a function of the resonance mass. W′ bosons with couplings predicted by the extended gauge model in the mass range from 1.3 to 1.5 TeV are excluded at 95% confidence level.
Resumo:
A search for new particles that decay into top quark pairs is reported. The search is performed with the ATLAS experiment at the LHC using an integrated luminosity of 20.3 fb−1 of proton-proton collision data collected at a centre-of-mass energy of s√=8 TeV. The lepton-plus-jets final state is used, where the top pair decays to W+bW−b¯¯, with one W boson decaying leptonically and the other hadronically. The invariant mass spectrum of top quark pairs is examined for local excesses or deficits that are inconsistent with the Standard Model predictions. No evidence for a top quark pair resonance is found, and 95% confidence-level limits on the production rate are determined for massive states in benchmark models. The upper limits on the cross-section times branching ratio of a narrow Z′ boson decaying to top pairs range from 4.2 pb to 0.03 pb for resonance masses from 0.4 TeV to 3.0 TeV. A narrow leptophobic topcolour Z′ boson with mass below 1.8 TeV is excluded. Upper limits are set on the cross-section times branching ratio for a broad colour-octet resonance with Γ/m = 15% decaying to tt¯. These range from 4.8 pb to 0.03 pb for masses from 0.4 TeV to 3.0 TeV. A Kaluza-Klein excitation of the gluon in a Randall-Sundrum model is excluded for masses below 2.2 TeV.
Resumo:
A search for a new resonance decaying to a W or Z boson and a Higgs boson in the ℓℓ/ℓν/νν+bb¯ final states is performed using 20.3 fb−1 of pp collision data recorded at s√= 8 TeV with the ATLAS detector at the Large Hadron Collider. The search is conducted by examining the WH/ZH invariant mass distribution for a localized excess. No significant deviation from the Standard Model background prediction is observed. The results are interpreted in terms of constraints on the Minimal Walking Technicolor model and on a simplified approach based on a phenomenological Lagrangian of Heavy Vector Triplets.
Resumo:
Tese de Doutoramento em Ciências (Especialidade em Química)
Resumo:
OBJECTIVES: To describe the process of translation and linguistic and cultural validation of the Evidence Based Practice Questionnaire for the Portuguese context: Questionário de Eficácia Clínica e Prática Baseada em Evidências (QECPBE). METHOD: A methodological and cross-sectional study was developed. The translation and back translation was performed according to traditional standards. Principal Components Analysis with orthogonal rotation according to the Varimax method was used to verify the QECPBE's psychometric characteristics, followed by confirmatory factor analysis. Internal consistency was determined by Cronbach's alpha. Data were collected between December 2013 and February 2014. RESULTS: 358 nurses delivering care in a hospital facility in North of Portugal participated in the study. QECPBE contains 20 items and three subscales: Practice (α=0.74); Attitudes (α=0.75); Knowledge/Skills and Competencies (α=0.95), presenting an overall internal consistency of α=0.74. The tested model explained 55.86% of the variance and presented good fit: χ2(167)=520.009; p = 0.0001; χ2df=3.114; CFI=0.908; GFI=0.865; PCFI=0.798; PGFI=0.678; RMSEA=0.077 (CI90%=0.07-0.08). CONCLUSION: confirmatory factor analysis revealed the questionnaire is valid and appropriate to be used in the studied context.
Resumo:
Here we focus on factor analysis from a best practices point of view, by investigating the factor structure of neuropsychological tests and using the results obtained to illustrate on choosing a reasonable solution. The sample (n=1051 individuals) was randomly divided into two groups: one for exploratory factor analysis (EFA) and principal component analysis (PCA), to investigate the number of factors underlying the neurocognitive variables; the second to test the "best fit" model via confirmatory factor analysis (CFA). For the exploratory step, three extraction (maximum likelihood, principal axis factoring and principal components) and two rotation (orthogonal and oblique) methods were used. The analysis methodology allowed exploring how different cognitive/psychological tests correlated/discriminated between dimensions, indicating that to capture latent structures in similar sample sizes and measures, with approximately normal data distribution, reflective models with oblimin rotation might prove the most adequate.