25 resultados para Photographic lenses.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the effect of orthokeratology for different degrees of myopia correction in the relative location of tangential (FT) and sagittal (FS) power errors across the central 70 of the visual field in the horizontal meridian. Methods: Thirty-four right eyes of 34 patients with a mean age of 25.2 ± 6.4 years were fitted with Paragon CRT (Mesa, AZ) rigid gas permeable contact lenses to treat myopia (2.15 ± 1.26D, range: 0.88 to 5.25D). Axial and peripheral refraction were measured along the central 70 of the horizontal visual field with the Grand Seiko WAM5500 open-field auto-refractor. Spherical equivalent (M), as well as tangential (FT) and sagittal power errors (FS) were obtained. Analysis was stratified in three groups according to baseline spherical equivalent: Group 1 [MBaseline = 0.88 to 1.50D; n = 11], Group 2 [MBaseline = 1.51 to 2.49D; n = 11], and Group 3 [MBaseline = 2.50 to 5.25D; n = 12]. Results: Spherical equivalent was significantly more myopic after treatment beyond the central 40 of the visual field (p50.001). FT became significantly more myopic for all groups in the nasal and temporal retina with 25 (p 0.017), 30 (p 0.007) and 35 (p 0.004) of eye rotation. Myopic change in FS was less consistent, achieving only statistical significance for all groups at 35 in the nasal and temporal retina (p 0.045). Conclusions: Orthokeratology changes significantly FT in the myopic direction beyond the central 40 of the visual field for all degrees of myopia. Changes induced by orthokeratology in relative peripheral M, FT and FS with 35 of eye rotation were significantly correlated with axial myopia at baseline. Keywords: Field

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Arquitectura

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The aim of this work was to study the central and peripheral thickness of several contact lenses (CL) with different powers and analyze how thickness variation affects CL oxygen transmissibility. METHODS: Four daily disposable and five monthly or biweekly CL were studied. The powers of each CL were: the maximum negative power of each brand; -6.00 D; -3.00 D; zero power (-0.25 D or -0.50 D), +3.00 D and +6.00 D. Central and peripheral thicknesses were measured with an electronic thickness gauge. Each lens was measured five times (central and 3mm paracentral) and the mean value was considered. Using the values of oxygen permeability given by the manufacturers and the measured thicknesses, the variation of oxygen transmissibility with lens power was determined. RESULTS: For monthly or biweekly lenses, central thickness changed between 0.061 ± 0.002 mm and 0.243 ± 0.002 mm, and peripheral thickness varied between 0.084 ± 0.002 mm and 0.231 ± 0.015 mm. Daily disposable lenses showed central values ranging between 0.056 ± 0.0016 mm and 0.205 ± 0.002 mm and peripheral values between 0.108 ± 0.05 and 0.232 ± 0.011 mm. Oxygen transmissibility (in units) of monthly or biweekly CL ranged between 39.4 ± 0.3 and 246.0 ± 14.4 and for daily disposable lenses the values range between 9.5 ± 0.5 and 178.1 ± 5.1. CONCLUSIONS: The central and peripheral thicknesses change significantly when considering the CL power and this has a significant impact on the oxygen transmissibility. Eyecare practitioners must have this fact in account when high power plus or minus lenses are fitted or when continuous wear is considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado em Ciências – Formação Contínua de Professores (área de especialização em Biologia e Geologia)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSES: To determine the level of compliance and major non-compliant behaviors in contact lens (CL) wearing medical doctors (MDs) and to compare it with age matched CL wearing normal subjects with no medical background (NS). METHODS: Thirty-nine current CL wearing MDs, who were prescribed CLs in Nepal Eye Hospital, Kathmandu, Nepal, between 2007 and 2011, were interviewed on ten modifiable compliant behaviors regarding lens care and maintenance. The level of compliance and the rate of non-compliance for each behavior were determined and compared with NS. RESULTS: Level of compliance was good, average and poor in 35.9%, 48.7% and 15.4% of MDs, respectively. There was no significant difference in compliance between MDs and NS (p=0.209). Level of compliance was not associated with age, gender and duration of lens wear (p>0.05). Compliance rate varied according to different behaviors, achieving a good compliance level of 95% for hand hygiene, avoidance of water contact and not sleeping with lenses. There was poor compliance for topping up solution (53.8%) and lens case replacement (15.4%). CONCLUSION: About one third of MDs had a good level of compliance. Level of compliance and compliance rate of different behaviors were similar in MDs and NS. Periodic lens case replacement was the most neglected behavior in CL wearers for this region.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de Doutoramento em Estudos da Criança - Especialidade Comunicação Visual e Expressão Plástica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Relatório de estágio de mestrado em História

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La carte postale est un kaléidoscope de vues, d’ornements et de couleurs, qui consacre un tout petit espace au message. C’est à la photographie et aux procédés de reproduction photomécaniques que revient le mérite d’avoir industrialisé la production de la carte postale. Et ce sont les clichés de villes, avec leurs monuments et leurs paysages, qui confèrent à la carte postale son statut de moyen de communication de masse et qui lui concèdent une affinité avec l’industrie du tourisme. La carte postale s’est ainsi emparée de l’ambition photographique de reproduire le monde, s’alliant aux « besoins de l’exploration, des expéditions et des relevés topographiques » du médium photographique à ses débuts. Ayant comme point de départ la carte postale, notre objectif est de montrer les conséquences culturelles de la révolution optique, commencée au milieu du XIXe siècle, avec l’invention de l’appareil photo, et consumée dans la seconde moitié du XXe siècle, avec l’apparition de l’ordinateur. En effet, depuis l’apparition de l’appareil photographique et des cartes postales jusqu’au flux de pixels de Google Images et aux images satellite de Google Earth, un entrelacement de territoire, puissance et technique a été mis en oeuvre, la terre devenant, en conséquence, de plus en plus auscultée par les appareils de vision, ce qui impacte sur la perception de l’espace. Nous espérons pouvoir montrer avec cette étude que la lettre traditionnelle est à l’email ce que la carte postale est au post que l’on publie dans un blog ou dans des réseaux comme Facebook et Twitter. À notre sens, les cartes postales correspondent à l’ouverture maximale du système postal moderne, qui d’universel devient dépendant et partie intégrante des réseaux télématiques d’envoi. Par elles sont annoncés, en effet, la vitesse de transmission de l’information, la brièveté de la parole et l’hégémonie de la dimension imagétique du message, et pour finir, l’embarras provoqué par la fusion de l’espace public avec l’espace privé.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado em Optometria Avançada

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado em Optometria Avançada