83 resultados para power series distribution
em Indian Institute of Science - Bangalore - Índia
Resumo:
Three new procedures for the extrapolation of series coefficients from a given power series expansion are proposed. They are based on (i) a novel resummation identity, (ii) parametrised Euler transformation (pet) and (iii) a modifiedpet. Several examples taken from the Ising model series expansions, ferrimagnetic systems, etc., are illustrated. Apart from these applications, the higher order virial coefficients for hard spheres and hard discs have also been evaluated using the new techniques and these are compared with the estimates obtained by other methods. A satisfactory agreement is revealed between the two.
Resumo:
The steady flow of a power law fluid in annuli with porous walls is investigated. The solution for the axial velocity component is obtained as a power series in terms of the cross flow Reynolds number, the first term of the series giving the solution for the case of the solid wall annulus. The cross flow is restricted to be such that the rate of injection of fluid at one wall of the annulus is equal to the rate of suction at the other wall and also we have considered only very small values of the cross flow velocity. The velocity profiles are drawn for different values of n and for different gaps and the results are discussed in detail. The behaviour of the average flux, in different eases is also discussed.
Resumo:
Large deflections of simply supported beams have been studied when the trans verse loading consists of a uniformity distributed load plus a century concentrate load under the two cases, (1) the reactions are vertical. (2) the reactions are normal to the bent beam together with frictional forces. The solutions are obtained by the use of power series expansions. This method is applicable to cases of symmetrical loading in beams.
Resumo:
The present paper records the results of a case study on the impact of an extensive grassland fire on the physical and optical properties of aerosols at a semi-arid station in southern India for the first time from ground based measurements using a MICROTOPS-II sunphotometer, an aethalometer and a quartz crystal microbalance impactor (QCM). Observations revealed a substantial increase in aerosol optical depth (AOD) at all wavelengths during burning days compared to normal days. High AOD values observed at shorter wavelengths suggest the dominance of accumulation mode particle loading over the study area. Daily mean aerosol size spectra shows, most of the time, power-law distribution. To characterize AOD, the Angstrom parameters (i.e., alpha and beta) were used. Wavelength exponent (1.38) and turbidity coefficient (0.21) are high during burning days compared to normal days, thereby suggesting an increase in accumulation mode particle loading. Aerosol size distribution suggested dominance of accumulation mode particle loading during burning days compared to normal days. A significant positive correlation was observed between AOD at 500 mn and water vapour and negative correlation between AOD at 500 nm and wind speed for burning and non-burning days. Diurnal variations of black carbon (BC) aerosol mass concentrations increased by a factor of similar to 2 in the morning and afternoon hours during burning period compared to normal days.
Resumo:
In this paper we have discussed the boundary layer on a plate with suction. The problem is solved near the leading edge as well as far downstream. A linear suction law is assumed near the leading edge for simplicity, whereas no restriction is placed on the suction law in the region downstream. An explict expression for boundary layer thickness in terms of suction speed and distance from leading edge is derived. It is found that the thickness of the boundary layer depends on the derivative of the suction speed. The skin friction also has been evaluated. Though near the leading edge a linear law of suction is assumed, the method used in the paper can be easily generalised for any other power law, for example, we may use a power series expansion for the function defining the suction velocity.
Resumo:
Potential transients are obtained by using “Padé approximants” (an accurate approximation procedure valid globally — not just perturbatively) for all amplitudes of concentration polarization and current densities. This is done for several mechanistic schemes under constant current conditions. We invert the non-linear current-potential relationship in the form (using the Lagrange or the Ramanujan method) of power series appropriate to the two extremes, namely near reversible and near irreversible. Transforming both into the Pad́e expressions, we construct the potential-time profile by retaining whichever is the more accurate of the two. The effectiveness of this method is demonstrated through illustrations which include couplings of homogeneous chemical reactions to the electron-transfer step.
Resumo:
Anderson localization is known to be inevitable in one-dimension for generic disordered models. Since localization leads to Poissonian energy level statistics, we ask if localized systems possess `additional' integrals of motion as well, so as to enhance the analogy with quantum integrable systems. We answer this in the affirmative in the present work. We construct a set of nontrivial integrals of motion for Anderson localized models, in terms of the original creation and annihilation operators. These are found as a power series in the hopping parameter. The recently found Type-1 Hamiltonians, which are known to be quantum integrable in a precise sense, motivate our construction. We note that these models can be viewed as disordered electron models with infinite-range hopping, where a similar series truncates at the linear order. We show that despite the infinite range hopping, all states but one are localized. We also study the conservation laws for the disorder free Aubry-Andre model, where the states are either localized or extended, depending on the strength of a coupling constant. We formulate a specific procedure for averaging over disorder, in order to examine the convergence of the power series. Using this procedure in the Aubry-Andre model, we show that integrals of motion given by our construction are well-defined in localized phase, but not so in the extended phase. Finally, we also obtain the integrals of motion for a model with interactions to lowest order in the interaction.
Resumo:
This paper presents three methodologies for determining optimum locations and magnitudes of reactive power compensation in power distribution systems. Method I and Method II are suitable for complex distribution systems with a combination of both radial and ring-main feeders and having different voltage levels. Method III is suitable for low-tension single voltage level radial feeders. Method I is based on an iterative scheme with successive powerflow analyses, with formulation and solution of the optimization problem using linear programming. Method II and Method III are essentially based on the steady state performance of distribution systems. These methods are simple to implement and yield satisfactory results comparable with the results of Method I. The proposed methods have been applied to a few distribution systems, and results obtained for two typical systems are presented for illustration purposes.
Resumo:
Handling unbalanced and non-linear loads in a three-phase AC power supply has always been a difficult issue. This has been addressed in the literature by either using fast controllers in the fundamental rotating reference frame or using separate controllers in reference frames specific to the harmonics. In the former case, the controller needs to be fast and in the latter case, besides the need for many controllers, negative-sequence components need to be extracted from the measured signal. This study proposes a control scheme for harmonic and unbalance compensation of a three-phase uninterruptible power supply wherein the problems mentioned above are addressed. The control takes place in the fundamental positive-sequence reference frame using only a set of feedback and feed-forward compensators. The harmonic components are extracted by a process of frame transformations and used as feed-forward compensation terms in the positive-sequence fundamental reference frame. This study uses a method wherein the measured signal itself is used for fundamental negative-sequence compensation. As the feed-forward compensator handles the high-bandwidth components, the feedback compensator can be a simple low-bandwidth one. This control algorithm is explained and validated experimentally.
Resumo:
Handling unbalanced and non-linear loads in a three-phase AC power supply has always been a difficult issue. This has been addressed in the literature by either using fast controllers in the fundamental rotating reference frame or using separate controllers in reference frames specific to the harmonics. In the former case, the controller needs to be fast and in the latter case, besides the need for many controllers, negative-sequence components need to be extracted from the measured signal. This study proposes a control scheme for harmonic and unbalance compensation of a three-phase uninterruptible power supply wherein the problems mentioned above are addressed. The control takes place in the fundamental positive-sequence reference frame using only a set of feedback and feed-forward compensators. The harmonic components are extracted by a process of frame transformations and used as feed-forward compensation terms in the positive-sequence fundamental reference frame. This study uses a method wherein the measured signal itself is used for fundamental negative-sequence compensation. As the feed-forward compensator handles the high-bandwidth components, the feedback compensator can be a simple low-bandwidth one. This control algorithm is explained and validated experimentally.
Resumo:
Handling unbalanced and non-linear loads in a three-phase AC power supply has always been a difficult issue. This has been addressed in the literature by either using fast controllers in the fundamental rotating reference frame or using separate controllers in reference frames specific to the harmonics. In the former case, the controller needs to be fast and in the lattercase, besides the need for many controllers, negative-sequence components need to be extracted from the measured signal.This study proposes a control scheme for harmonic and unbalance compensation of a three-phase uninterruptible power supply wherein the problems mentioned above are addressed. The control takes place in the fundamental positive-sequence reference frame using only a set of feedback and feed-forward compensators. The harmonic components are extracted by process of frame transformations and used as feed-forward compensation terms in the positive-sequence fundamental reference frame. This study uses a method wherein the measured signal itself is used for fundamental negative-sequence compensation. As the feed-forward compensator handles the high-bandwidth components, the feedback compensator can be a simple low-bandwidth one. This control algorithm is explained and validated experimentally.
Resumo:
This study presents a novel magnetic arm-switch-based integrated magnetic circuit for a three-phase series-shunt compensated uninterruptible power supply (UPS). The magnetic circuit acts as a common interacting field for a number of energy ports, viz., series inverter, shunt inverter, grid and load. The magnetic arm-switching technique ensures equivalent series or shunt connection between the inverters. In normal grid mode (stabiliser mode), the series inverter is used for series voltage correction and the shunt one for current correction. The inverters and the load are effectively connected in parallel when the grid power is not available. These inverters are then used to share the load power. The operation of the inverters in parallel is ensured by the magnetic arm-switching technique. This study also includes modelling of the magnetic circuit. A graphical technique called bond graph is used to model the system. In this model, the magnetic circuit is represented in terms of gyrator-capacitors. Therefore the model is also termed as gyrator-capacitor model. The model is used to extract the dynamic equations that are used to simulate the system using MATLAB/SIMULINK. This study also discusses a synchronously rotating reference frame-based control technique that is used for the control of the series and shunt inverters in different operating modes. Finally, the gyrator-capacitor model is validated by comparing the simulated and experimental results.
Resumo:
An efficient load flow solution technique is required as a part of the distribution automation (DA) system for taking various control and operations decisions. This paper presents an efficient and robust three phase power flow algorithm for application to radial distribution networks. This method exploits the radial nature of the network and uses forward and backward propagation to calculate branch currents and node voltages. The proposed method has been tested to analyse several practical distribution networks of various voltage levels and also having high R/X ratio. The results for a practical distribution feeder are presented for illustration purposes. The application of the proposed method is also extended to find optimum location for reactive power compensation and network reconfiguration for planning and day-to-day operation of distribution networks.