20 resultados para measuring engagement

em Indian Institute of Science - Bangalore - Índia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here, we describe a novel FBG interrogation system in which FBGs are used as both sensing and reference elements. The reference FBGs is bonded to a mechanical flexure system having a linear amplification of 1:3.5, which is actuated using a piezo-actuator by applying a 0-150V ramp. The lengths of the reference gratings decide the maximum strain that can be applied to the reference grating, which in turn decides that strain range which can be interrogated. The main advantages of the present system are the on-line measurement of the wavelength shifts, small size, good sensitivity, multiplexing capability and low cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transmission-line or the impedance-tube method for the measurement of the acoustic impedance of any termination involves a search for various minima and maxima of pressure. For this purpose, arrangement has to be made for the microphone to travel along the length of the impedance tube, and this complicates the design of the tube considerably. The present paper discusses a method which consists in evaluating the tube attenuation factor at any convenient frequency by making use of measured SPL's at two (or more) fixed locations with a rigid termination, calculating the tube attenuation factor and wave number at the required frequency of interest with or without mean flow (as applicable), and finally evaluating the impedance of the given termination by measuring and using SPL's at three (or more) fixed locations. Thus, the required impedance tube is considerably smaller in length, simpler in design, easier to manufacture, cheaper in cost and more convenient to use. The design of the tube is also discussed. Incidentally, it is also possible to evaluate the impedance at any low frequency without having to use a larger impedance tube.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Separated local field (SLF) spectroscopy is a powerful technique to measure heteronuclear dipolar couplings. The method provides site-specific dipolar couplings for oriented samples such as membrane proteins oriented in lipid bilayers and liquid crystals. A majority of the SLF techniques utilize the well-known Polarization Inversion Spin Exchange at Magic Angle (PISEMA) pulse scheme which employs spin exchange at the magic angle under Hartmann-Hahn match. Though PISEMA provides a relatively large scaling factor for the heteronuclear dipolar coupling and a better resolution along the dipolar dimension, it has a few shortcomings. One of the major problems with PISEMA is that the sequence is very much sensitive to proton carrier offset and the measured dipolar coupling changes dramatically with the change in the carrier frequency. The study presented here focuses on modified PISEMA sequences which are relatively insensitive to proton offsets over a large range. In the proposed sequences, the proton magnetization is cycled through two quadrants while the effective field is cycled through either two or four quadrants. The modified sequences have been named as 2(n)-SEMA where n represents the number of quadrants the effective field is cycled through. Experiments carried out on a liquid crystal and a single crystal of a model peptide demonstrate the usefulness of the modified sequences. A systematic study under various offsets and Hartmann-Hahn mismatch conditions has been carried out and the performance is compared with PISEMA under similar conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple technique for the measurement of the beam shape parameters of pulsed lasers, with just a single pulse of the laser is described. It involves the use of several beam dividers inclined at very small angles to the beam axis, reflecting the beam back to a screen or a phosphor placed near the exit of the laser. The reflected images are then photographed by a camera to yield the beam parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and rapid bioassay of inhibin is described. Swiss albino female mice, 27 days old, weighing 25-30 g, were primed with 20 IU hCG, given in 2 equal doses, administered at 0900 h and 1800 h. An increment of 200% in uterine weight could be observed when the animals were autopsied the next day at 1000 h. The validity of the endpoint chosen, as a function dependent on FSH, was shown by the fact that neutralization of endogenous FSH by FSH antiserum led to an inhibition of uterine weight increase. Further injection of the inhibin material caused an actual reduction in the heightened levels of FSH (ng/ml) brought about by hCG: Control, 207 ± 13.6; hCG, 365 ± 28.8 and hCG inhibin, below the detection level of radioimmunoassay. Inhibin preparation from ovine testicular extract when tested at 3 dose levels showed a dose dependent and significant suppression in uterine weight increase. The assay was statistically validε = 2.5; slope = 23.9; λ = 0.104 and intra- and interassay variation = 8.3% and 11.7%, respectively. Since the mouse uterine weight assay is specific, has greater sensitivity and is uniformly reproducible, it is suggested that this assay procedure is ideally suited to assess the activity of different inhibin test preparations as well as to follow the purification of inhibin activity from crude material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of a radioreceptor assay (RRA) that can measure serum LH in a variety of species and CG in sera and urine of pregnant women and monkeys is reported. Using sheep luteal membrane as the receptor source and I-125-labelled hLH/hCG as the tracer, dose-response (displacement) curves were obtained using hLH or hCG as standard. The addition of LH-free serum (200 mul per tube) had no affect on the standard displacement curve. The assay is simple, requires less than 90 min to complete and provides reproducible results. The sensitivity of the assay was 0.6 ng hLH per tube and the intra- and interassay variations were 9.6 and 9.8, respectively. Sera obtained from male and female bonnet monkeys (Macaca radiata) and monkey pituitary extract showed parallelism to the standard curve. The concentrations of LH measured correlated with the physiological status of the animals. Sera of rats, rabbits, hamsters, guinea-pigs, sheep and humans showed parallelism to the hLH standard curve indicating the viability of the RRA to measure serum LH of different species. Since the receptors recognize LH and CG, detection of pregnancy in monkeys and women was possible using this assay. The sensitivity of the assay for hCG was 8.7 miu per tube. This RRA could be a convenient alternative to the Leydig cell bioassay for obtaining the LH bioactivity profile of sera and biological fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multisensor recordings are becoming commonplace. When studying functional connectivity between different brain areas using such recordings, one defines regions of interest, and each region of interest is often characterized by a set (block) of time series. Presently, for two such regions, the interdependence is typically computed by estimating the ordinary coherence for each pair of individual time series and then summing or averaging the results over all such pairs of channels (one from block 1 and other from block 2). The aim of this paper is to generalize the concept of coherence so that it can be computed for two blocks of non-overlapping time series. This quantity, called block coherence, is first shown mathematically to have properties similar to that of ordinary coherence, and then applied to analyze local field potential recordings from a monkey performing a visuomotor task. It is found that an increase in block coherence between the channels from V4 region and the channels from prefrontal region in beta band leads to a decrease in response time.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Unambiguous evidence for the engagement of CF3 group in N-H center dot center dot center dot F-C hydrogen bond in a low polarity solvent, the first observation of its kind, is reported. The presence of such weak molecular interactions in the solution state is convincingly established by one and two-dimensional H-1, F-19, and natural abundant N-15 NMR spectroscopic studies. The strong and direct evidence is derived by the observation of through-space couplings, such as, (1h)J(FH), (1h)J(FN), and (2h)J(FF), where the spin polarization is transmitted through hydrogen bond. In an interesting example of a molecule containing two CF3 groups getting simultaneously involved in hydrogen bond, where hydrogen bond mediated couplings are not reflected in the NMR spectrum, F-19-F-19 NOESY experiment yielded confirmatory evidence. Significant deviations in the strengths of (1)J(NH), variable temperature, and the solvent induced perturbations yielded additional support. The NMR results are corroborated by both DFT calculations and MD simulations, where the quantitative information on different ways of involvement of fluorine in two and three centered hydrogen bonds, their percentage of occurrences, and geometries have been obtained. The hydrogen bond interaction energies have also been calculated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proportional Navigation (PN) and its variants are widely used guidance philosophies. However, in the presence of target maneuver, PN guidance law is effective only for a restrictive set of initial geometries. To account for target maneuvers, the concept of Augmented Proportional Navigation (APN) guidance law was introduced and analyzed in a linearized interceptor-target engagement framework presented in literature. However, there is no work in the literature, that addresses the capturability performance of the APN guidance law in a nonlinear engagement framework. This paper presents such an analysis and obtains the conditions for capturability. It also shows that a shorter time of interception is obtained when APN is formulated in the nonlinear framework as proposed in this paper. Simulation results are given to support the theoretical findings.