60 resultados para dynamic performance appraisal
em Indian Institute of Science - Bangalore - Índia
Resumo:
The importance of air bearing design is growing in engineering. As the trend to precision and ultra precision manufacture gains pace and the drive to higher quality and more reliable products continues, the advantages which can be gained from applying aerostatic bearings to machine tools, instrumentation and test rigs is becoming more apparent. The inlet restrictor design is significant for air bearings because it affects the static and dynamic performance of the air bearing. For instance pocketed orifice bearings give higher load capacity as compared to inherently compensated orifice type bearings, however inherently compensated orifices, also known as laminar flow restrictors are known to give highly stable air bearing systems (less prone to pneumatic hammer) as compared to pocketed orifice air bearing systems. However, they are not commonly used because of the difficulties encountered in manufacturing and assembly of the orifice designs. This paper aims to analyse the static and dynamic characteristics of inherently compensated orifice based flat pad air bearing system. Based on Reynolds equation and mass conservation equation for incompressible flow, the steady state characteristics are studied while the dynamic state characteristics are performed in a similar manner however, using the above equations for compressible flow. Steady state experiments were also performed for a single orifice air bearing and the results are compared to that obtained from theoretical studies. A technique to ease the assembly of orifices with the air bearing plate has also been discussed so as to make the manufacturing of the inherently compensated bearings more commercially viable. (c) 2012 Elsevier Inc. All rights reserved.
Resumo:
The soft switching converters evolved through the resonant load, resonant switch, resonant transition and active clamp converters to eliminate switching losses in power converters. This paper briefly presents the operating principle of the new family of soft transition converters; the methodology of design of these converters is presented through an example. In the proposed family of converters, the switching transitions of both the main switch and auxiliary switch are lossless.When these converters are analysed in terms of the pole current and throw voltage, the defining equations of all converters belonging to this family become identical.Such a description allows one to define simple circuit oriented model for these converters. These circuit models help in evaluating the steady state and dynamic model of these converters. The standard dynamic performance functions of the converters are readily obtainable from this model. This paper presents these dynamic models and verifies the same through measurements on a prototype converter.
Resumo:
The soft switching converters evolved through the resonant load, resonant switch, resonant transition and active clamp converters to eliminate switching losses in power converters. This paper briefly presents the operating principle of the new family of soft transition converters; the methodology of design of these converters is presented through an example. In the proposed family of converters, the switching transitions of both the main switch and auxiliary switch are lossless. When these converters are analysed in terms of the pole current and throw voltage, the defining equations of all converters belonging to this family become identical.Such a description allows one to define simple circuit oriented model for these converters. These circuit models help in evaluating the steady state and dynamic model of these converters. The standard dynamic performance functions of the converters are readily obtainable from this model. This paper presents these dynamic models and verifies the same through measurements on a prototype converter.
Resumo:
Active-clamp dc-dc converters are pulsewidth-modulated converters having two switches featuring zero-voltage switching at frequencies beyond 100 kHz. Generalized equivalent circuits valid for steady-state and dynamic performance have been proposed for the family of active-clamp converters. The active-clamp converter is analyzed for its dynamic behavior under current control in this paper. The steady-state stability analysis is presented. On account of the lossless damping inherent in the active-clamp converters, it appears that the stability region in the current-controlled active-clamp converters get extended for duty ratios, a little greater than 0.5, unlike in conventional hard-switched converters. The conventional graphical approach fails to assess the stability of current-controlled active-clamp converters due to the coupling between the filter inductor current and resonant inductor current. An analysis that takes into account the presence of the resonant elements is presented to establish the condition for stability. This method correctly predicts the stability of the current-controlled active-clamp converters. A simple expression for the maximum duty cycle for subharmonic free operation is obtained. The results are verified experimentally.
Resumo:
This paper focuses on a new high-frequency (HF) link dc-to-three-phase-ac power converter. The least number of switching devices among other HF link dc-to-three-phase-ac converters, improved power density due to the absence of devices of bidirectional voltage-blocking capability, simple commutation requirements, and isolation between input and output are the integral features of this topology. The commutation process of the converter requires zero portions in the link voltage. This causes a nonlinear distortion in the output three-phase voltages. The mathematical analysis is carried out to investigate the problem, and suitable compensation in modulating signal is proposed for different types of carrier. Along with the modified modulator structure, a synchronously rotating reference-frame-based control scheme is adopted for the three-phase ac side in order to achieve high dynamic performance. The effectiveness of the proposed scheme has been investigated and verified through computer simulations and experimental results with 1-kVA prototype.
Resumo:
This paper deals with the application of artificial commutation for a normally rated inverter connecting a weak AC system in a multiterminal HVDC (MTDC) system. Artificial commutation is achieved using series capacitors. A modular digital simulation technique is developed to study the dynamic performance of the system. It is shown that by a proper selection of the value of the capacitor it is possible to limit the valve stresses and the DC harmonics to acceptable levels and achieve an improved performance during severe transient conditions. The determination of the value of the series capacitor is based on a parametric study.
Resumo:
This paper makes an attempt to assess the benefits of replacing a conventional generator excitation system (AVR + PSS) with a nonlinear voltage regulator using the concepts of synchronizing and damping torque components in a single machine infinite bus (SMIB) system. In recent years, there has been considerable interest in designing nonlinear excitation controllers, which are expected to give better dynamic performance over a wider range of system and operating conditions. The performance of these controllers is often justified by simulation studies on few test cases which may not adequately represent the diverse operating conditions of a typical power system. The performance of two such nonlinear controllers which are designed based on feedback linearization and include automatic voltage regulation with good dynamic performance have been analyzed using an SMIB model. Linearizing the nonlinear control laws along with the SMIB system equations, a Heffron Phillip's type of a model has been derived. Concepts of synchronizing and damping torque components have been used to show that such controllers can impair the small signal stability under certain operating conditions. This paper shows the possibility of negative damping contribution due to nonlinear voltage regulators and gives a new insight on understanding the physical impact of complex nonlinear control laws on power system dynamics.
Resumo:
Active-clamp dc-dc converters are pulsewidth-modulated converters having two switches featuring zero-voltage switching at frequencies beyond 100 kHz. Generalized equivalent circuits valid for steady-state and dynamic performance have been proposed for the family of active-clamp converters. The active-clamp converter is analyzed for its dynamic behavior under current control in this paper. The steady-state stability analysis is presented. On account of the lossless damping inherent in the active-clamp converters, it appears that the stability region in the current-controlled active-clamp converters get extended for duty ratios, a little greater than 0.5 unlike in conventional hard-switched converters. The conventional graphical approach fails to assess the stability of current-controlled active-clamp converters, due to the coupling between the filter inductor current and resonant inductor current. An analysis that takes into account the presence of the resonant elements is presented to establish the condition for stability. This method correctly predicts the stability of the current-controlled active-clamp converters. A simple expression for the maximum duty cycle for subharmonic-free operation is obtained. The results are verified experimentally.
Resumo:
This paper reports the dynamic stability analysis of a single machine infinite bus system through torque angle loop analysis and forms an extension of the work on Block diagrams and torque angle loop analysis of synchronous machines reported by I. Nagy [3]. It aims to incorporate in the machine model, the damper windings (one on each axis) and to compare the dynamic behaviour of the system with and without damper windings. The effect of using different stabilizing signals (viz. active power and speed deviations) on the dynamic performance is analysed and the significant effect of damper windings on the dynamic behaviour of the system is highlighted.
Resumo:
A performance prediction model generally applicable for volute-type centrifugal pumps has been extended to predict the dynamic characteristics of a pump during its normal starting and stopping periods. Experiments have been conducted on a volute pump with different valve openings to study the dynamic behaviour of the pump during normal start-up and stopping, when a small length of discharge pipeline is connected to the discharge flange of the pump. Such experiments have also been conducted when the test pump was part of a hydraulic system, an experimental rig, where it is pumping against three similar pumps, known as supply pumps, connected in series, with the supply pumps kept idle or running. Instantaneous rotational speed, flowrate, and delivery and suction pressures of the pump were recorded and it was observed in all the tested cases that the change of pump behaviour during the transient period was quasi-steady, which validates the quasi-steady approach presented in this paper. The nature of variation of parameters during the transients has been discussed. The model-predicted dynamic head-capacity curves agree well with the experimental data for almost all the tested cases.
Resumo:
In the design of °ight control system modeling uncertainties in the form of param-eter variations is one of the major problems. It is even more critical for high performance aircrafts,since such aircrafts are purposefully designed unstable to enhance their performance (especially ma-neuverability). Hence the °ight control system needs to be quite e®ective in both assuring accurate tracking of pilot commands, while simultaneously assuring overall stability of the aircraft. In addi-tion, the control system must also be su±ciently robust to cater for possible parameter variations and inaccuracies . The primary aim of this paper is to carry out a robustness study of a dynamic inversion based nonlinear control design for a high performance aircraft, which has been developed recently [1].
Resumo:
This paper proposes a new straight forward technique based on dynamic inversion, which is applied for tracking the pilot commands in high performance aircrafts.Pilot commands assumed in longitudinal mode are normal acceleration and total velocity(while roll angle and lateral acceleration are maintained at zero). In lateral mode, roll rate and total velocity are used as pilot commands (while climb rate and lateral acceleration are maintained at zero). Ensuring zero lateral acceleration leads to a better turn co-ordination. A six degree-of-freedom model of F-16 aircraft is used for both control design as well as simulation studies. Promising results are obtained which are found to be superior as compared to an existing approach (which is also based on dynamic inversion). The new approach has two potential benefits, namely reduced oscillatory response and reduced control magnitude. Another advantage of this approach is that it leads to a significant reduction of tuning parameters in the control design process.
Resumo:
The performance of metal hydride based solid sorption cooling systems depends on the driving pressure differential, and the rate of hydrogen transfer between coupled metal hydride beds during cooling and regeneration processes. Conventionally, the mid-plateau pressure difference obtained from `static' equilibrium PCT data are used for the thermodynamic analysis. It is well known that the processes are `dynamic' because the pressure and temperature, and hence the concentration of the hydride beds, are continuously changing. Keeping this in mind, the pair of La0.9Ce0.1Ni5 - LaNi4.7Al0.3 metal hydrides suitable for solid sorption cooling systems were characterised using both static and dynamic methods. It was found that the PCT characteristics, and the resulting enthalpy (Delta H) and entropy (Delta S) values, were significantly different for static and dynamic modes of measurements. In the present study, the solid sorption metal hydride cooling system is analysed taking in to account the actual variation in the pressure difference (Delta P) and the dynamic enthalpy values. Compared to `static' property based analysis, significant decrease in the driving potentials and transferrable amounts of hydrogen, leading to decrease in cooling capacity by 57.8% and coefficient of performance by 31.9% are observed when dynamic PCT data at the flow rate of 80 ml/min are considered. Copyright 2014 (C) Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
Resumo:
In the present study, amino-silane modified layered organosilicates were used to reinforce cyclic olefin copolymer to enhance the thermal, mechanical and moisture impermeable barrier properties. The optimum clay loading (4%) in the nanocomposite increases the thermal stability of the film while further loading decreases film stability. Water absorption behavior at 62 degrees C was carried out and compared with the behavior at room temperature and 48 degrees C. The stiffness of the matrix increases with clay content and the recorded strain to failure for the composite films was lower than the neat film. Dynamic mechanical analysis show higher storage modulus and low loss modulus for 2.5-4 wt% clay loading. Calcium degradation test and device encapsulation also show the evidence of optimum clay loading of 4 wt% for improved low water vapor transmission rates compared to other nanocomposite films. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
An abundance of spectrum access and sensing algorithms are available in the dynamic spectrum access (DSA) and cognitive radio (CR) literature. Often, however, the functionality and performance of such algorithms are validated against theoretical calculations using only simulations. Both the theoretical calculations and simulations come with their attendant sets of assumptions. For instance, designers of dynamic spectrum access algorithms often take spectrum sensing and rendezvous mechanisms between transmitter-receiver pairs for granted. Test bed designers, on the other hand, either customize so much of their design that it becomes difficult to replicate using commercial off the shelf (COTS) components or restrict themselves to simulation, emulation /hardware-in-Ioop (HIL), or pure hardware but not all three. Implementation studies on test beds sophisticated enough to combine the three aforementioned aspects, but at the same time can also be put together using COTS hardware and software packages are rare. In this paper we describe i) the implementation of a hybrid test bed using a previously proposed hardware agnostic system architecture ii) the implementation of DSA on this test bed, and iii) the realistic hardware and software-constrained performance of DSA. Snapshot energy detector (ED) and Cumulative Summation (CUSUM), a sequential change detection algorithm, are available for spectrum sensing and a two-way handshake mechanism in a dedicated control channel facilitates transmitter-receiver rendezvous.