6 resultados para cattle farms

em Indian Institute of Science - Bangalore - Índia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study, we report for the first time the efficacy of recombinant Bm95 mid gut antigen isolated from an Argentinean strain of Rhipicephalus microplus strain A in controlling the tick infestations in India. The synthetic gene for Bm95 optimized for expression in yeast was obtained and used to generate yeast transformants expressing Bm95 which was purified to apparent homogeneity. Liquid chromatography-mass spectrometry analysis of the purified protein confirmed its identity as Bm95. Vaccine was prepared by blending various concentrations of purified Bm95 with aluminium hydroxide as an adjuvant. lmmunogenicity studies of the vaccine in rabbits and cattle indicated that the vaccine was highly immunogenic. The efficacy studies of the vaccine was done in cattle. Naive Bos indicus cattle were vaccinated with the recombinant vaccine and were challenged with the larval, nymphal and adult forms of Rhiphicephalus haemaphysaloides. The vaccine protected the animals from larval, nymph and adult tick challenges with an efficacy of 98.7%, 84.6% and 78.9% respectively. The results obtained from the above studies clearly demonstrated the advantage and possibilities of the use of Bm95 in controlling R. haemaphysaloides infestations in the field. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of malathion on jugular plasma concentrations of follicle-stimulating hormone (FSH), estradiol (E2), progesterone (P4) and acetylcholinesterase (AchE) on conception in dairy cattle during a cloprostenol (prostaglandin F2-alpha analogue, PG)-induced estrus was studied. Malathion (1 mg/kg, intraruminally) given at the onset of estrus (48 h after PG) did not alter the plasma FSH or E2 concentrations but significantly (P < 0.05) inhibited plasma P4 concentration. The mean P4 concentration in the malathion-treated group on days 8 and 12 were 0.8 +/- 0.4 and 1.0 +/- 0.5 ng/ml, as compared to 2.6 +/- 0.0 and 2.4 +/- 0.3 ng/ml in the control group. There was a nonsignificant (P > 0.05) inhibition of plasma AchE activity in malathion-treated cattle. Conception was 16.6% in malathion-treated cows and 50% in controls. Inhibition of progesterone secretion and poor conception occurred after the single intraruminal dose of malathion at the onset of estrus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wind power, as an alternative to fossil fuels, is plentiful, renewable, widely distributed, clean, produces no greenhouse gas emissions during operation, and uses little land. In operation, the overall cost per unit of energy produced is similar to the cost for new coal and natural gas installations. However, the stochastic behaviour of wind speeds leads to significant disharmony between wind energy production and electricity demand. Wind generation suffers from an intermittent characteristics due to the own diurnal and seasonal patterns of the wind behaviour. Both reactive power and voltage control are important under varying operating conditions of wind farm. To optimize reactive power flow and to keep voltages in limit, an optimization method is proposed in this paper. The objective proposed is minimization of the voltage deviations of the load buses (Vdesired). The approach considers the reactive power limits of wind generators and co-ordinates the transformer taps. This algorithm has been tested under practically varying conditions simulated on a test system. The results are obtained on a system of 50-bus real life equivalent power network. The result shows the efficiency of the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studies the feasibility of utilizing the reactive power of grid-connected variable-speed wind generators to enhance the steady-state voltage stability margin of the system. Allowing wind generators to work at maximum reactive power limit may cause the system to operate near the steady-state stability limit, which is undesirable. This necessitates proper coordination of reactive power output of wind generators with other reactive power controllers in the grid. This paper presents a trust region framework for coordinating reactive output of wind generators-with other reactive sources for voltage stability enhancement. Case studies on 418-bus equivalent system of Indian southern grid indicates the effectiveness of proposed methodology in enhancing the steady-state voltage stability margin.